Anua Aerocell A Series User manual

©Anua 07-2023 336.547.9338 anuainternati nal.c m
Aer Cell®
Open Cell Foam Biofilter
Owner’s
Manual

A roC ll®
Owner’s Manual
336.547.9338 anuainternati nal.c m
Tabl of Cont nts
1.0 Classification Statement 1
2.0 Typical AeroCell System Configuration 2
3.0 Process Description 3
4.0 Operating Instructions 4
5.0 Maintenance Schedule 5
6.0 Compliance with Regulations 5
7.0 Safety 6
8.0 Emergency Contact Details 6
9.0 Limited Warranty 7
10.0 Treatment System Tracking Sheet 8

A roC ll®
Owner’s Manual
1
336.547.9338 anuainternati nal.c m
1.0 Classification Stat m nt
The AeroCell open cell foam biofilter treatment system has been tested, certified,
and listed by NSF International as meeting the requirements of NSF/ANSI Standard
40, Class 1 for models bearing the NSF mark.
A S ri s
IM S ri s
Model Number Mod Type Notes
Table 1 AeroCell Models
Only mods bearing the NSF® mark
are certified NSF/ANSI Standard 40, Class I
Q-ATS-A400-80/20-AC Anua HDPE (1) ATS-A400
Q-ATS-A400-80/20-2-AC Anua HDPE (2) ATS-A400
Q-ATS-A400-80/20-3-AC Anua HDPE (3) ATS-A400
Q-ATS-540-AC-N Infilt ato IM-540 Tank (1) IM-540
Q-ATS-1060-AC-N Infilt ato IM-1060 Tank (1) IM-1060
Q-ATS-1530-AC-N Infilt ato IM-1530 Tank (1) IM-1530

A roC ll®
Owner’s Manual
2
336.547.9338 anuainternati nal.c m
2.0 Typical A roC ll Syst m Configuration
Dosing
Pump
Grommet
Weep Holes
Outlet Option
for Pad Dispersal
Control Panel
Float Tree
Bracket and
-Hook
Either 1st or 2nd Compartment
(Route to 1st Compartment for
Enhanced Nitrogen Removal)
80% Flow for R turn
Flow In
20% Flow
for Disp rsal
2" Drain Line
Outlet Option
Float
Tree
Gravity Effluent
Filter Option
Lid
Riser
1.25” Pressure
Line Inlet
4” Line
A S ri s Mod Option
Options:
Quanics Filtered Pump Vault
Sim/Tech Pressure Filter
Sim/Tech Nova Filter with Pleated Screen
Dosing Tank
S ptic Tank
2x Design Flow
or per
Engineered Design
1x Design Flow
or per
Engineered Design
IM S ri s Mod Option

A roC ll®
Owner’s Manual
3
336.547.9338 anuainternati nal.c m
3.0 Proc ss D scription
Quanics AeroCell is an onsite treatment
system utilizing fixed film or packed bed
media in an unsaturated environment. The
engineered media is housed in a plastic or
fiberglass mod. Effluent is sprayed over the
media utilizing helical spray nozzles. This
engineered delivery system evenly distrib-
utes effluent over the media.
Open cell foam has high porosity and large
surface area that allows for hydraulic loading
rates up to ten times that of sand. The appli-
cation rates for the AeroCell system have
been carefully selected to provide optimal
treatment and long-term performance.
The media properties provide an optimum
environment for free air flow and water
movement. Open cell foam has been used in
treatment applications for over two-decades.
Pretreatment of the domestic sewage occurs
using a septic tank equipped with an effluent
filter, with nominal 1/32" filtration, on the
outlet. Alternatively, the Sim/Tech pressure
filter or Sim/Tech Nova (No-Vault) filter may
be used, in a progressive filtration configura-
tion, to meet the nominal 1/32" filtration
requirement. The primary treated effluent
then moves into a dosing tank where a pump
doses the screened effluent to the treatment
mod. The effluent dosing occurs in short, fre-
quent durations over a 24 hour period utiliz-
ing a control panel with a repeat cycle timer.
Once sprayed, the effluent moves via gravity
down through the media where natural
microbiological processes occur that provide
high level treatment. After passing through
the full depth of media, the effluent travels to
the bottom of the mod and the flow is split
with 80% back into the treatment stream and
20% to the final dispersal point. The final
treated effluent meets the requirements of
NSF/ANSI Standard 40, Class 1.NSF/ANSI
Standard 40, Class 1.
Op n C ll Foam M dia

A roC ll®
Owner’s Manual
4
336.547.9338 anuainternati nal.c m
4.0 Op rating Instructions
The AeroCell system has been designed and
built to provide efficient, dependable and
reliable operation. However, as with any on-site
treatment system, routine periodic service is
required. When proper routine maintenance
is performed, these systems will operate at
designed performance levels giving years of
satisfactory treatment of domestic sewage.
The authorized distributor from whom you
purchased your AeroCell system will coordi-
nate routine inspections for the first 2 years
from the original date of installation. At the
time of inspection, the system will be checked
for proper operation. If a problem exists, service
will be performed with permission from the
owner. At the end of the 2 year initial service
period, your authorized distributor will assist
you in continuing your service policy.
The treatment system electrical controls are
located within the control panel. The control
panel enclosure is equipped with an alarm
beacon and an audible horn alarm. See
“System Troubleshooting Guide” in this
manual for instructions on what to do if the
alarm beacon or horn comes on. After a
power failure, if an alarm remains on for more
than one hour you should call the service
provider immediately.
Your AeroCell system will handle all domestic
sewage, from your home. By the term sewage,
we are referring to rapidly biodegradable
material. To keep maintenance at a minimum
level and to prevent the system from mal-
functioning, the following guidelines need to
be followed:
Since naturally occurring aerobic bacteria
(nothing added to the system) are respon-
sible for treating the effluent, inorganic or
non rapidly biodegradable materials should
not be put into the system. Examples of
improper items are: plastic products, rubber
products, sanitary napkins or tampons,
washcloths, cigarette butts, coffee
grounds, eggshells, matches, or other
non-biodegradable objects.
Do not dispose of cooking grease or large
amounts of oil into system; instead pour it
into a container and dispose of it properly.
To minimize pump-out frequency, limit use
of garbage disposals.
Lint from lint catchers, hair, etc., should be
disposed in the trash and not washed down
the drain.
Water softener backwash should not be
routed through the system. Another
source of disposal should be used.
Diapers can be rinsed out in the toilet;
however, do not flush cloth or disposable
diapers down the toilet.
Large amounts of harsh chemicals, high-
sudsing detergents, disinfectants or any
substance that kills bacteria must not be
discharged into the system.
The system will not perform to its fullest
capabilities if volumetric overload is
allowed to occur. This occurs whenever
excessive water, above the designed flow
rate, is allowed into the system. Excessive
water use or leaking plumbing fixtures may
cause this condition.
The proper operation of this system depends
upon proper organic and hydraulic loading of
the system. We cannot control the loading
and thereby cannot control the amount of
harmful substances that may be discharged
into the system. Only the users of a system
can control what enters the system.

A roC ll®
Owner’s Manual
5
336.547.9338 anuainternati nal.c m
5.0 Maint nanc Sch dul
Normal maintenance every 6 months on your
AeroCell system will include:
a. Maintaining effluent filter
b. Maintaining filtered pump vault
c. Proper pump operation
d. Inspecting and testing system alarms
e. Check spray nozzles for debris
f. Inspect septic/dosing tanks for pump out
N te 1: Replacement parts can be obtained
from your authorized distributor or Anua.
N te 2: Pumping the septic/dosing tanks is
usually necessary every 3 to 5 years; however,
there is no set time because loadings vary from
household to household. Access to the tank(s)
is accomplished through the access opening(s),
which is at finished grade. The tank(s) must
be sprayed down during pump-out. The
biosolids from the system must be disposed
of in compliance with all federal, state, and
local regulations.
Warning - Caution must be used when
pumping water out any tank. Hydraulic
displacement and tank flotation may occur
whenever effluent and solids are removed
from the tank when high groundwater condi-
tions exist. Any source of water in the soil
around the system installation could cause
the tank to float. Water sources may include
6.0 Complianc with R gulations
All permits and approvals from the local
regulatory authority must be obtained
before the treatment system is installed.
All state and federal regulations must be
complied with in areas that do not have local
permitting authority.
It is important to remember that each state
has independent regulations and guidelines
for the installation of this treatment system
and any auxiliary equipment that may accom-
pany the system. You are responsible for
installing this system and associated ancillary
items in accordance with all regulations and
guidelines as they are issued in your respective
state. Pretreatment tanks, storage or equaliza-
tion tanks, pump tanks, etc., must comply with all
applicable regulations for design and installation.
Anua, through its years of experience, recog-
nizes the advantages of every component of the
treatment system. Please contact us for assis-
tance or inquiries at 336.547.9338.
rainfall, springs, creeks, bayous, rivers, lakes,
and coastal areas. Proper precautions are
therefore required to prevent tank flotation
due to hydraulic displacement.
These precautions include, but are not limited
to, the following:
System locations - choose a site that will
minimize possible groundwater saturation.
Consider seasonal water table and soil
conditions in the area of installation. Do
not locate the system in a low spot in the
ground where water tends to pool or at the
edge of any natural body of water. If such a
location cannot be avoided, call Anua at
336.547.9338 for technical assistance.
It is recommended that you pump septic
or dosing tank(s) during dry seasons only.
However, if tank(s) must be pumped during
the wet season, watch for upward move-
ment of the tank(s) while pumping is being
done. If upward movement is detected
during pumping, immediately stop pumping
out the tank(s). The tank(s) must be
refilled to stop flotation. Each site must
be evaluated on a case-by-case basis to
determine the best time to remove tank
contents and prevent flotation.

A roC ll®
Owner’s Manual
6
336.547.9338 anuainternati nal.c m
8.0 Em rg ncy Contact D tails
In the unlikely event that you experience a problem with your AeroCell system or if service is
required, you should contact your authorized service provider. The contact details for your
authorized service provider can be found on the service data label that is attached to the
control panel. You should reference the AeroCell serial number found on the system data label
attached to the mod(s) when you contact the authorized service provider or manufacturer.
8.1 Manufacturer C ntact Inf rmati n
Name: Anua
Address: PO Box 77457, Greensboro, North Carolina 27417
Phone: 336.547.9338
Email : [email protected]
Website: anuainternational.com
8.2 Auth rized Service Pr vider C ntact Inf rmati n
To identify the initial service provider for your system, check the labels on the control panel
and fill in the table below:
Name: ___________________________________________________________
Address: ___________________________________________________________
Office Phone: ___________________________________________________________
Mobile Phone: ___________________________________________________________
Email: ___________________________________________________________
Website: ___________________________________________________________
7.0 Saf ty
Since sewage and effluent contains some
level of pathogenic microorganisms, proper
respect and care must be given to safety.
Whenever you come into contact with
sewage or effluent, take proper precautions
to avoid direct contact.
Follow these simple safety precautions
whenever exposed to the biosolids or effluent
in the system:
Wear disposable rubber gloves when
handling contaminated items.
Always wash with soap and water after
handling contaminated items. The use of
alcohol-based hand sanitizer is strongly
recommended after handwashing.
Always dispose of scum, rags, trash,
debris, or soiled material in a proper waste
container.
If a spill or leak occurs in the yard, flush
the area with plenty of clean water and
disinfectant. If a spill or leak occurs in the
house, clean with a dilute solution of bleach.
Protect any injury, wound, open cut, etc.,
from exposure to biosolids or effluent.
If an illness or disease is suspected to have
come from exposure to sewage, get proper
medical attention immediately. There are
some serious diseases that could be trans-
mitted by contact with sewage—take the
proper precautions and be safe!

A roC ll®
Owner’s Manual
7
336.547.9338 anuainternati nal.c m
9.0 Limit d Warranty
Anua®, herein identified as Anua, warrants
each AeroCell®treatment system to be free
from defects in material and workmanship for
a period of two (2) years from the date of
installation by an authorized installer for the
end user when properly trained by Anua or an
authorized representative. The sole obligation
under this warranty is as follows: Anua shall
fulfill this warranty by replacing or exchanging
any component part, FOB factory that in Anua’s
judgment shows evidence of defects, provided
said component part has been paid for and is
returned through an authorized Distributor,
transportation prepaid. The Limited
Warranty does not make any provision for an
informal dispute settlement arrangement.
The warranty does not apply to any defects
whether patent or latent, and whether work-
manship or materials or design of works
carried out by any independent contract, or
any failure due to accidental or malicious
damage, or failure to comply with recom-
mendations for operations and maintenance,
or unit abuse, fair wear and tear, frost, storm
damage, infiltration of storm or surface
water or any other such climatic conditions
or act of God generally.
The warranty does not cover the AeroCell
treatment system and related components
that have flooded, by external means, or that
have been disassembled by unauthorized
person, improperly installed, subjected to
external damage or damage due to altered
or improper wiring or overload protection.
Recommendations for special applications
will be based upon the best available expertise
of Anua and published industry information.
Such recommendations do not constitute a
warranty of satisfactory performance.
No warranty is made as to the field perform-
ance of any systems. The Limited Warranty
applies to the systems and does not include
any portion of the plumbing, drainage, electrical
wiring or installation of the treatment systems.
Accessories supplied by Anua, but manufac-
tured by others, are warranted for a period of
two (2) years. In no event shall Anua be
responsible for delay or damages of any kind
or character resulting from, or caused directly
or indirectly by, defective components or
materials manufactured by others.
The Limited Warranty extends to the end
user of this product. The end user is defined
as the purchaser who first has the system
installed, or in the case of the system designed
for non-permanent installation, the purchaser
who first uses the system. It is the end
user’s obligation to make known to any other
consumer the terms and conditions of this
Limited Warranty.
Anua reserves the right to revise, change, or
modify the construction and design of the
AeroCell treatment system, or any compo-
nent part or parts thereof, without incurring
any obligations to make such changes or
modifications in previously sold equipment.
Anua also reserves the right, in making
replacements of component parts under this
warranty, to furnish a component part,
which, in its judgment, is equivalent to the
part replaced. This warranty is a Limited
Warranty. No claim of any nature shall be
made against Anua unless and until the end
user, or their legal representative, notifies
Anua, in writing of the defect complained of
and delivers the product and /or defective
part(s), freight prepaid, to Anua or an author-
ized Anua dealer.
This warranty is strictly limited to the
replacement of product supplied by Anua. It
specifically excludes all other alleged headings
of loss, including consequential loss.

A roC ll®
Owner’s Manual
8
336.547.9338 anuainternati nal.c m
10.0 Tr atm nt Syst m Tracking Sh t
!
$#"!!
"!
$#
&"%
(
&
*+
('
-+
.+ "
!'&
"&""&
!
(!
&
,''"
(
"
''!/"""
&
"
(
&
"
!")
(
""'""',!,'
&
!,
"
"
&
(
""(''
""""
''
!"
!&
&
(!
"""(""
&"
"&"
"'+
"""
"
'
0+ 1
2+
(!
3+
5+ &6
!"(%%
&
''
"!''
(
"(&"
&
("
("(
7"&
"
&
(&"
!"
''"(
"&'"""'&&"
!")(
1
&
('8
(&
"
&!'
&
&
&
4
&'!
("(&"
!"(
(
(&"
'
(
4"(

A roC ll®
Owner’s Manual
9
336.547.9338 anuainternati nal.c m
:"9
"
&
&
&&
!
"+/
$#"!!
"
;$
!&,"
!&,!
&;
&;
&;
";
";
"!9
"!9
"
"
!&,!
+/&
&
&
&&
!&
!&!
<<.2-34,
;
;
";
-.<*94>=
"!9
<<*94"
"
:"9
;$
"
&;
&;
&;
&
&
&&
"+/
=
"
!&,"
!&,!
+/&
&
&
&&
!&
!&!
<<.2-34,
;
;
";
";
-.<*94>=
"!9
"!9
<<*94"
"
"
"
"
!!!
;
#
!!
"""$
'%&""""(

P.O. Box 77457
Greensboro, NC 27417
T 336.547.9338
F 336.547.8559
anuainternational.com
©Anua 07-2023
This manual suits for next models
7
Table of contents
Popular Water Filtration System manuals by other brands

Enwa
Enwa MT 1500 Operational manual

UNITED
UNITED Tower-Flo TFH Series Engineering, Installation, Operation & Maintenance

CMP
CMP DEL AOP PRO 200 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

CALEFFI
CALEFFI HydroLink 559921A manual

EIGER
EIGER Terminal Pure Water Series instruction manual

Eriez
Eriez ROTA-GRATE Installation, operation and maintenance instructions