ANXELL DG-750 User manual

◆ Features
• 12~24 VAC/VDC operation
• 1,010 User codes
• 2 Form C relays, each rated 10A@30VDC
• Each relay has programmable output time from 1~99 seconds or toggle
• Output #2 can be programmed for use with a door bell
• 2 Egress inputs for exiting the premises without keying in the code
• Split controller installation protects the keypad access from magnet tampering
• Accommodate a Two Man Rule by cascading 2 relays.
• Backlit keys for easy nighttime use
• Able to mount to a single-gang back box
• Door sensor input for anti-tailgating operation
• All features are programmed directly from the keypad - no need for an external programmer
• EEPROM memory protects programmed information in case of power loss
• Tamper contact for added security
• Circuitry is potted with epoxy for outdoor use
• IP65 weatherproof rating, rugged zinc alloy construction
DG-750
Access Keypad with Split Controller
2 3/4” (69.5mm)
1/8” (60.3mm)
1/4” (6mm)
4 13/16”(122.8mm)
7/8” (22.8mm)
3 1/16” (78.5mm)
Copyright © All rights reserved. P-MU-DG-750 Published 2019.07.01

◆ Specifications
Current draw
Holding
Pull in
50mA/12VDC ;31mA/24VDC
Operating Voltage 12~24 VAC/VDC
103mA/12VDC ;56mA/24VDC
Relay Outputs
Egress Inputs
Operating Temperature
Output #1
Output #2
Input #1
Input #2
Max 10A/30VDC, Form C, NO/NC/COM
Max 10A/30VDC, Form C, NO/NC/COM
N.O. Ground
N.O. Ground
-4°~140°F (-20°~60°C)
◆ LED Indicators
◆ Audible Indicators
Audible Tone
1 Long tone
1 Short tone
3 Short tone
Keypad Status
Confirmation
Key press
User code denied
6 Short + 1 Long tone All user codes deleted
LED
Steady Amber Programming Mode
Keypad Status
Flashing Amber Waiting to programming entry
Steady Green Waiting to program card/code
Steady Red Card/code already present
Steady Green Relay 1 activated
Steady Red Relay 2 activated
Copyright © All rights reserved. P-MU-DG-750 Published 2019.07.01

◆ Programming Instructions
1. Codes are programmed to be 4~6 digits in length. All codes must be the same length.
2. Before inputting any of the following, enter Programming Mode by entering the Master Code twice.
The default master code is 1234.
To enter Programming Mode, enter 1 2 3 4 1 2 3 4
3. To exit Programming Model, press the # key.
4. The keypad will exit Programming Mode if no keys are pressed for 30 seconds.
◆ Programming Tips
• Program a new Master Code immediately.
• Take note of the keypad status LED –
■ LED Solid Amber: Programming Mode
■ LED Solid Green: Awaiting code entry
• If you are unsure of which mode the keypad is in, press # until the LED is off. The keypad is now in
the Standby Mode. Enter the master code twice to return to Programming Mode.
Copyright © All rights reserved. P-MU-DG-750 Published 2019.07.01
Model: DBR-200
COM
NO
INPUT
AC/DC
To Keypad To Keypad
12VDC
12VDC
12 VDC
◆ Sample wiring and applications
Relay 2
Relay 1
Electric Lock 2
Fail-safe Mode
Power Supply Unit
Varistor
Exit Button 2
Electric Lock 1
Fail-secure Mode
Power Supply Unit
Diode
Exit Button1
REED
Door Closed = N.O.
Door Open = N.C.
Tamp(-)
(Anti-tamper alarm function is
triggered at the same time)
12VDC
(Max Current 100mA )
Emergency Light
12~24V Black Red Yellow Green
Black Wire Cable
Power Supply Unit

◆ First Time Keypad Use
Take these steps the first time the keypad is programmed.
A. Enter Programming Mode
Enter 1234 1234 (Default Master Code is 1234)
B. Program Code Length
NOTE: To keep the default 4-digit code length, skip to step C, Program the Master Code.
WARNING: After a new code length is programmed, all user codes will be deleted and the master code will be reset.
1. Enter Programming Mode by entering the Master Code twice. (Default Master Code is 1234).
2. Enter * 904
3. Enter the desire code length. This must be a number from 4~6.
4. Exit Programming Mode by pressing #.
The Master Code will reset depending on the programmed code length. These will be the new Master Codes
after the code length is reset:
Code Length
4 digits
5 digits
6 digits
New Master Code
1234
12345
123456
C. Program the Master Code
1. Enter Programming Mode by entering the Master Code twice. (Default Master Code is 1234).
2. Enter * 3
3. Enter the new Master Code twice. The Master Code may not be the same as a user code.
Example: If the desired new Master Code is 4321, enter 4 3 2 1 4 3 2 1
4. Exit Programming Mode by pressing #.
◆ Programming Output #1:
NOTE: For all of the following programming functions, the keypad must be in Programming Mode. To enter
Programming Mode, enter the Master Code twice.
Programming User Code
1. Enter a user ID number ( 0 0 0 to 9 9 9 )
2. If the LED is red, previous user data exists. Clear it by entering * *. The keypad will beep in confirmation
and the LED will turn green.
3. Enter a new user code.
4. To program the next user, repeat from step 1.
5. Exit Programming Mode by pressing #.
Copyright © All rights reserved. P-MU-DG-750 Published 2019.07.01

◆ Programming Output #2:
NOTE: For all of the following programming functions, the keypad must be in Programming Mode.
To enter Programming Mode, enter the Master Code twice.
Programming an output #2 User Code
1. Enter * 4
2. Enter a user ID number ( 0 0 to 0 9 )
3. if the LED is red, previous user data exists. Clear it by entering * *. The keypad will beep in confirmation
and the LED will turn green.
4. Enter a new user code.
5. To program the next user, repeat from step 2.
6. Return to Programming Mode by pressing #.
7. Exit Programming Mode by pressing # again.
◆ Deleting or Changing Users:
Deleting or Changing an Output #1 User:
Step 1 Enter a user ID number: 0 0 0 to 9 9 9
Step 2 Delete existing user by entering: * *
Step 3 Enter a new user code x x x x or
Return to Programming Mode by entering #
Deleting or Changing an Output #2 User:
Step 1 Enter: * 4
Step 2 Enter a user ID number: 0 0 to 0 9
Step 3 Delete existing user by entering: * *
Step 4 Enter a new user code x x x x or
Return to Programming Mode by entering #
◆ Additional Programming:
Programming the Output# 1 Timer
DEFAULT: 1 second
Step 1 Enter: *1
Step 2 For toggle mode, enter 0 0 or for timed output, enter 01 to 99
01 to 99 is the number of seconds Output #1 will activate
Programming the Output# 2 Timer
DEFAULT: 1 second
Step 1 Enter: *5
Step 2 For toggle mode, enter 0 0 or for timed output, enter 01 to 99
01 to 99 is the number of seconds Output #2 will activate
Copyright © All rights reserved. P-MU-DG-750 Published 2019.07.01

Programming the Output# 2 Function
Output #2 can be activated via * or through user codes. Use the following steps to program its function.
DEFAULT: User Codes
Step 1 Enter: *2
Step 2 For user codes, enter 01
For door bell, enter 02
When output #2 is programmed for doorbell, press * to activate doorbell. Doorbell output lasts 1 second.
◆ Factory Default:
NOTE: Resetting the keypad will cause some or all programmed data to be lost. Do not perform either of these
steps unless it is absolutely necessary.
Deleting All Users: Enter * 8 8 8
IMPORTANT: Once key entry is made, all user codes will be deleted and the keypad will return to Programming
Mode. The Master Code and all other programming settings will remain the same.
Restore Factory Settings: Enter * 8 9 9
IMPORTANT: Once key entry is made, keypad will return to factory default settings. No user information will be
retained and the Master Code will be 1234.
Manually Resetting the Master Code:
If the Master Code has been forgotten or does no work, the following steps can be taken to reset the Master Code:
1. Disconnect power from the keypad.
2. Press the # key continuously and connect power again.
3. The keypad will beep to confirm a successful reset.
Note: Manually resetting the Master Code will only reset the Master Code. It will not affect the Master Code,
User Code or any other saved data.
Code Length 4 digits
◆ Factory Default:
Master Code 1234
Output #1 Access Mode User codes
Output #1 User Codes None
Output #2 User Codes None
Output #1 Timer 1 second
Output #2 Timer 1 second
Output #2 Function User codes