Aolait AL120Twins User manual

Dual Head 2R Moving Head Light
AL120Twins
USER MANUAL

1
Fixture Introduction ............................................................................................2
Safety Information ................ ...............................................................................3
Installation ..................................... .......................................................................5
Power Supply ................................. .......................................................................6
Signal Connection ................................ ................................................................. 8
Fixture Setting ....................................... ................................................................9
Channel List .............................................. ...........................................................12
Maintenance ................................................. ........................................................18
Thank you very much for purchasing this product! Before any use, please carefully read and fully
understand all of this manual recorded safety instructions to avoid potential hazards may cause bodily
injury, property damage or product damage. The Company does not undertake any direct loss and loss
associated with the manual instructions pressed caused.
INDEX

2
Fixture Introduction
Item Number: AL120Twins
Item Description: Dual Head 2R Moving Head Light
Technical Parameter
Voltage: AC100-250V 50/60Hz
Power Consumption:400W
Lamp: 2pcs of Yodn MSD 132 R2 (Optional Philips/Osram)
Lifespan: 6000Hours
Color Temperature: 8000K
DMX control: 25/28/38 Channels
Pan: 540°/630°,8/16Bit resolution
Tilt: 270°,8/16Bit resolution
Pan/Tilt infinite rotation
Color: 13 colors + Open
Gobos: 14 gobos+ Open
Effect: Bi-directional rotating 8-facet prism; Frost effect
Focus: Electrical focus
Beam angle: 3°
0-100% mechanical dimmer; Strobe: 0.5-14/sec
Built-in overheat protection; Remote lamp control
IP grade: IP20
Net Weight: 17.5Kgs
Size: Unit:mm

3
Safety Information
This product would cause serious injury or fatal electric shock, burning, lamp explosion,
falling.
Read the Safety Information Chapter before installation, power, maintenance. Follow
the safety guidiance on light body
Shock protection
Disconnect the external power supply when open the cover or replacement parts, or lamps
not in use.
Ensure reliable equipment and used with overload protection and grounding and lighting
that matches the AC voltage frequency
Use 5A rated load over three-core power cable
Before use, ensure that the cable is in a normal state and is suitable for the amount
of current connected devices
When power cable or plug is damaged, wet or power is overheating, disconnect power
immediately
Do not expose this product to rain or humid air
Safely grounded
Lamp Safety
Prolonged exposure can cause eye and skin burns Before adding blocking ultraviolet
discharge bulbs, do not look directly into the mouth and lit light bulb
Cover, light barrier, lenses, protective screen or damaged insulation sheet lamps, do
not use
Protective screen on lamps, lenses or ultraviolet screens if produce visible damage,
that damage to the extent of the failure, such as when cracks or deep marks, should
be replaced
Lamps should only be used with the full use of protective cover Strip
Hot strong pressure discharge lamp may explode without warning phenomenon
Therefore, maintenance or operation of the bulb inside the lamp body shall wear goggles
and gloves and ensure adequate cooling fixtures
Do not use defective, damaged or have any other defective bulb, the bulb is damaged
or deformed, replace
Monitor lamp usage time and the light fades, the specification or in front of the bulb
manufacturer rated lamp life lamp replacement
Bulbs installed to comply with the relevant safety requirements
If the lamp is broken quartz sphere, will release a small amount of mercury and toxic
gas. If you are in a small space, please evacuate and thorough ventilation of this space
WARNING:
Read the Safety Information Chapter before any installation, connection to power and
maintenance of this product,
For Professional use only!

4
as soon as possible, collect the ruptured lamp should wear protective gloves, not to
be thrown away when the light bulb scrapped, should these poisonous dangerous goods
sent to specialized treatment institutions
Burns and fire prevention
Exterior lighting during use may be relatively high temperature, avoid contact with
the human body or other object, please let the lamp to cool sufficiently before handling
Ensure combustible materials (such as: fabric, wood, paper, etc.) at least 0.2 meters
away from the lamps, flammable items away from the equipment as possible, to ensure
that air inlet and outlet of at least 0.1 meters of space
Do not directly irradiated surfaces within 10 m range
During the day when the lens cover or turn the direction of the lens to avoid direct sunlight on
the lens, because the lens can focus the sun causing a potential fire hazard
When the ambient temperature exceeds 40 ° C (104 ° F). Do not start to use
Do not modify the fixture anyway, do not install non-original parts, not paste any
filters on the lens or other optical accessories, pictures
Do not attempt to short-circuit fuse or thermostat switch
Avoid falling damage
Don’t operate alone when handling fixture A
On the hanger to be used both uniform light hook, shall use a separate light hook
When the clip the device to TRUSS rack or other vertical hanging bracket and is not,
please change the lamp with butterfly buckle hook, hook may not use G-shaped lights
and quickdraw lights and other lights hook hook attachment is not completely surround
the lighthouse after the installation.
Ensure support and hanging system can support more than 10 times the weight of the
fixture.
Enhance safety rope hanging lamps and the focal point of the lamps shall handle
Install insurance rope, safety rope must be able to withstand 10 times the weight of
the lamp
Make sure the external accessories and fastening spreader complete
Installation, maintenance, and mobile lighting should have a stable platform, which
should have a security fence just below
Related operations are not described in this article, please consult an authorized
after-sales department

5
INSTALLTION
WARNING:
When hanging lamps, you must install additional safety rope to prevent the harm
caused by failure of the lamp hook,
Insurance Department of Insurance Eyelet rope must position lamps shall be
installed on the carrying handle
When the lamp is not trustworthy place, head of the movement may be driven by the
movement of the base,
Therefore, in unacknowledged or hanging lamps firmly placed the case, do not turn
During the day when the lens cover or turn the direction of the lens to avoid direct
sunlight on the lens, fire hazard because the lens can focus sunlight potentially

6
Hanging
1. OMEGA bracket lamp installed on the hook and tighten the screws
2. The OMEGA bracket to lamp base, clockwise tightening fast lock
3. Lamps on each side of a person, lift the fixture, the lamp poles and locking snap hook
4. The insurance rope through the base hole, and tied to a pole
Installation Notes:
1.Confirm hook hanging lamps and accessories undamaged and can withstand 10 times the
total weight of the lamps and cables and accessories, etc.
2.Note that the lamp lighting the front direction of the bottom body portion of the base
label
3.Installation, maintenance, and mobile lighting should have a stable platform, which
should have a security fence just below.
4.The insurance insurance rope through the rope hole lamp base, and tied to the lamp housing,
shall not tied to the handle
5.Check the lamp housing do not have the range of combustible material within 0.2 meters,
lamps light beam directed not to be blocked within 10 meters, and the neighborhood do
not have flammable substances
6.Check the lamps are not likely to collide with each other at the time of exercise
7.Check other lamps are not directly irradiated on this fixture, a strong light can damage
the protective shell lamps
8.Always make sure when you put the installation being installed in a horizontal plane,
so as not to slip occurs when the shell running lamps
Power Supply
WARNING:
To prevent electric shock, lamp must be grounded, the main power circuit
breaker must have insurance and switches and ground fault protection
Please fixtures directly connected to an AC power source, not connected
to the silicon box to prevent damage to the lamp
Power Input
Lamps internal switching power supply with PFC power supply voltage AC100V-240V 50 / 60Hz
Power Connection:
Plug the power cord has been installed a lighting power connector with mating plug the other
end should install an appropriate power plug, three-pin plug with grounding. Must follow
the manufacturer's instructions to install. The following table shows some plug pin
connector recommendations. If you are unsure or have questions, please consult a qualified
electrician. To power, the power switch should pull to the position "I"。

7
Cable color
Plug
Mark
Brown
FireWire
L
Blue
Zero wire
N
Yellow/Green
Ground wire
When the power cord is scratched lines skin, the outer protective skin breakage
or length is too short and should be replaced
Replace wire
1.Remove the original power cord
2.Clipping about a 1 m long, 3*1.5 square specifications for cable
3.The size of the cable by stripping the figure above, through the plug end caps
and fasteners
4.The core plug in the correct position in pressing on L- Brown N- blue - yellow
/ green
5.The plug assembled and tighten the end cap
6.Connect the other end of the power cord right with grounded three-prong plug
connector

8
Signal Connection
Lighting by XLR plug XLR DMX input and output signals, defined as follow:
3 core and 5 core plug and socket adapter, 5-pin XLR pin 4 / Pin 5 is not used
Data Connection:
1 Connect a DMX signal cable from the controller to the lighting signal input port
2 Connect a DMX signal cable from the lamp signal output port to the next fixture
3 fixtures DMX signal line only series, for use in parallel signal distributor
3 In the last fixture between the signal output 2 feet and 3 feet of a termination resistor
connected across
Reliability Tips
Use for RS-485 shielded twisted-pair design: standard microphone cable is not suitable for
long-distance data transmission, cable transmission 24AGW the distance over 300 meters
(1000 feet), while long-distance transmission lines to be thicker diameter cable, and
preferably with a signal amplifier branching drive (signal in parallel) need to use signal
splitter last fixture between the signal output terminal 2 feet and 3 feet spanning a 120
ohm quarter watt resistor, so to avoid interference signal reflection, empathy, such as
the use of the dispenser, also need to take in their terminal on this resistance

9
Fixture setting
Menu:
Address
System
Channel Mode
Standard
Reduced
Extend
Backlight
Auto
Keep On
Manual
Lamp Control
Turn On/Turn Off
Lamp Power
Full Power/Low Power
Reset
Head Reset
XY Reset
All Reset
Channel
Auto Test
Test Program 1
Test Program 1
Test Program 2
Test Program 2
Test Program 3
Test Program 3
Close
Close
Option
PAN/TILT
Invert Pan
Invert Tilt
Pan Distance
Curve
Curve 1
Curve 2
Curve 3
Display
Normal
Turnover
Light Lamp
DMX Order
Auto Order
Dimmer mode
Two Dimmers
One Dimmer
Language
中文/English

10
Detailed Settings
Open the lamp, press the MENU key to enter the setup menu. Through the upper and lower
buttons select the desired setting item, press ENTER key to enter the child; press ENTER
to save the setting is completed, press the MENU button to return to the standby screen.
Lighting should be set up when not in power has been pressing the ENTER key, opened the
display panel, the setup is complete return to the standby screen, the display panel will
be turned off automatically.
◆IP Address
Press ENTER to save press Up, Down keys to select 1 to 512, set up after: Lighting address
code. Press MENU to return to the standby screen.。
◆System settings
1:Mode
Standard mode: 28 Control channels
Reduced mode: 25 control channels
Extended mode: 38 control channels
Lighting factory default settings are: Standard mode 28 control channels
2:Back light settings
Setting the display backlight automatically or normally open, lights did not receive
the signal display will flash tips
◆System settings:
1:Lamp control Manually control lamp on/off
2:Lamp power Manually control lamp power
3:System setting Manually reset part of all function
4:Channels control Manually control fixture function
◆Automatic test
Lighting automatically run the built-in test program
◆Selections:

11
1:Pan/Tilt Setting:
Set X-axis inverted, Y-axis inverted, X axis running angle (540 degrees / 630 degrees, the
default setting is 540 degrees), each setting basis having ENTER to save
2:Dimmer curve
Select dimming curve, the default settings are: curve one
3:Display Setting
Setting the display forward or flip the display, in the main menu while holding down two
keys can be set directly
4:Lighting mode
Set up bulbs on, DMX lighting: need controller control lighting the bulb.
Automatic lighting: lighting the lamp will turn on automatically after POST
5:Dimmer mode
Some controller don’t support two dimmer channels for one fixture. Set up here for single
head dimmer
Dual Dimmer: About two lamp can be individually controlled dimming (the default setting
for the double dimmer)
Monotonous light: two lamp dimmer run together (just left lamp dimmer control channel)
◆Language(Language setting)
Language, 中文 or English, press Enter to save

12
Channel List
Reduced
Standard
Extended
Channel Name
Value
Function
1
1
1
Pan
0-255
PAN MOVEMENT 8bit (540°or 630°)
2
2
Pan 16Bit
0-255
PAN FINE 16bit
2
3
3
Left Tilt
0-255
LEFT TILT MOVEMENT 8bit
4
4
Left Tilt 16Bit
0-255
LEFT TILT FINE 16bit
3
5
5
Right Tilt
0-255
RIGHT TILT MOVEMENT 8bit
7
6
Right Tilt 16Bit
0-255
RIGHT TILT FINE 16bit
4
7
7
Left Color
0-8
OPEN
9/18
COLOR 1
19-26
COLOR 2
27-35
COLOR 3
36-44
COLOR 4
45-53
COLOR 5
54-62
COLOR 6
63-71
COLOR 7
72-80
COLOR 8
81-89
COLOR 9
90-98
COLOR 10
99-107
COLOR 11
108-116
COLOR 12
117-127
COLOR 13
128-191
CW ROTATION FAST - SLOW
192-255
CCW ROTATION SLOW - FAST
8
Left Color 16Bit
0-255
SET UP COLOR CHANGE TO ANY POSITION
5
8
9
Right Color
0-8
OPEN
9/18
COLOR 1
19-26
COLOR 2
27-35
COLOR 3
36-44
COLOR 4
45-53
COLOR 5
54-62
COLOR 6
63-71
COLOR 7
72-80
COLOR 8
81-89
COLOR 9
90-98
COLOR 10
99-107
COLOR 11
108-116
COLOR 12
117-127
COLOR 13
128-191
CW ROTATION FAST - SLOW
192-255
CCW ROTATION SLOW - FAST
10
Right Color 16Bit
0-255
SET UP COLOR CHANGE TO ANY POSITION

13
6
9
11
Left Gobo
0-7
OPEN
8/15
GOBO 1
16-23
GOBO 2
24-31
GOBO 3
32-39
GOBO 4
40-47
GOBO 5
48-55
GOBO 6
56-63
GOBO 7
64-71
GOBO 8
72-79
GOBO 9
80-87
GOBO 10
88-95
GOBO 11
96-103
GOBO 12
104-111
GOBO 13
112-119
GOBO 14
120-126
GOBO 1 SHAKE
127-133
GOBO 2 SHAKE
134-140
GOBO 3 SHAKE
141-147
GOBO 4 SHAKE
148-154
GOBO 5 SHAKE
155-161
GOBO 6 SHAKE
162-168
GOBO 7 SHAKE
169-175
GOBO 8 SHAKE
176-182
GOBO 9 SHAKE
183-189
GOBO 10 SHAKE
190-196
GOBO 11 SHAKE
197-203
GOBO 12 SHAKE
204-210
GOBO 13 SHAKE
211-217
GOBO 14 SHAKE
218-255
GOBO WHEEL ROTATION SLOW - FAST
12
Left Gobo 16Bit
0-255
SET UP GOBO CHANGE TO ANY POSITION
7
10
13
Right Gobo
0-7
OPEN
8/15
GOBO 1
16-23
GOBO 2
24-31
GOBO 3
32-39
GOBO 4
40-47
GOBO 5
48-55
GOBO 6
56-63
GOBO 7
64-71
GOBO 8
72-79
GOBO 9
80-87
GOBO 10
88-95
GOBO 11

14
96-103
GOBO 12
104-111
GOBO 13
112-119
GOBO 14
120-26
GOBO 1 SHAKE
127-133
GOBO 2 SHAKE
134-140
GOBO 3 SHAKE
141-147
GOBO 4 SHAKE
148-154
GOBO 5 SHAKE
155-161
GOBO 6 SHAKE
162-168
GOBO 7 SHAKE
169-175
GOBO 8 SHAKE
176-182
GOBO 9 SHAKE
183-189
GOBO 10 SHAKE
190-196
GOBO 11 SHAKE
197-203
GOBO 12 SHAKE
204-210
GOBO 13 SHAKE
211-217
GOBO 14 SHAKE
218-255
GOBO WHEEL ROTATION SLOW - FAST
14
Right Gobo 16Bit
0-255
SET UP COLOR CHANGE TO ANY POSITION
8
11
15
Left Focus
0-255
Far-Near
16
Left Focus 16Bit
0-255
9
12
17
Right Focus
0-255
Far-Near
18
Right Focus 16Bit
0-255
10
13
19
Left Frost
0-127
OPEN
128-255
FROST
11
14
20
Right Frost
0-127
OPEN
128-255
FROST
12
15
21
Left Prism
0-127
OPEN
128-255
8 FACET PRISM
13
16
22
Left Prism
Rotation
0-127
PRISM INDEXING
128-189
CW ROTATION FAST - SLOW
190-193
NO ROTATION
194-255
CCW ROTATION SLOW - FAST
23
Left Prism
Indexing 16Bit
0-255
14
17
24
Right Prism
0-127
OPEN
128-255
8 FACET PRISM
15
18
25
Right Prism
Rotation
0-127
PRISM INDEXING
128-189
CW ROTATION FAST - SLOW
190-193
NO ROTATION
194-255
CCW ROTATION SLOW - FAST
26
Right Prism
Indexing 16Bit
0-255

15
16
19
27
Left Shutter
0-31
SHUTTER CLOSED
32-63
SHUTTER OPEN
64-95
STROBING SLOW - FAST
96-127
SHUTTER OPEN
128-159
PULSE EFFECT IN SEQUENCES
160-191
SHUTTER OPEN
192-223
RANDOM STROBE SLOW - FAST
224-255
SHUTTER OPEN
17
20
28
Left Dimmer
0-255
Dimmer0-100%
29
Left Dimmer 16Bit
0-255
18
21
30
P/T Speed
0-225
MAX TO MIN. SPEED
226-235
BLACKOUT BY MOVEMENT
236-245
BLACKOUT BY WHEEL CHANGING
246-255
NO FUNCTION
19
22
31
Right Shutter
0-31
SHUTTER CLOSED
32-63
SHUTTER OPEN
64-95
STROBING SLOW - FAST
96-127
SHUTTER OPEN
128-159
PULSE EFFECT IN SEQUENCES
160-191
SHUTTER OPEN
192-223
RANDOM STROBE SLOW - FAST
224-255
SHUTTER OPEN
20
23
32
Right Dimmer
0-255
Dimmer0-100%
33
Right Dimmer 16Bit
0-255
21
24
34
Tilt Run Mode
0-79
TWO TILTS MOVEMENT SEPERATELY
80-159
TWO TILTS WHOLE MOVEMENT
160-255
NO FUNCTION
22
25
35
Pan Rotation
0-127
NO FUNCTION
128-189
FORWARDS ROTATION FAST-SLOW
190-193
NO FUNCTION
194-255
BACKWARDS ROTATION SLOW-FAST
23
26
36
Left Tilt Rotation
0-127
NO FUNCTION
128-189
FORWARDS ROTATION FAST-SLOW
190-193
NO FUNCTION
194-255
BACKWARDS ROTATION SLOW-FAST
24
27
37
Left Tilt Rotation
0-127
NO FUNCTION
128-189
FORWARDS ROTATION FAST-SLOW
190-193
NO FUNCTION
194-255
BACKWARDS ROTATION SLOW-FAST
25
28
38
Control
0-19
COLOR CHANGE NORMAL
20-29
COLOR CHANGE TO ANY POSITION
30-39
COLOR & GOBO CHANGE TO ANY POSITION
40-59
LAMP ON

16
60-79
LAMP OFF
80-120
PAN AND TILT RESET
121-160
HEAD MOTOR RESET
161-255
ALL RESET
Route map

17

18
Maintenance&cleaning
Lamps need daily cleaning. Time factor depends on the environment and cleaning cycles
related to the following:
Used with smoking machine, frog machine
High rate of local wind speed (eg: air inlet and outlet)
Dust(Such as stage effect )
If one or more of the above factors, the lamp after 100 hours of operation or need
to check the cleaning, and then periodically checked
Contact technician if any repairs are not mentioned here.
WARNING:
Before opening the lamp housing, disconnect the AC power and allow the lamp
to cool completely
Be careful when cleaning optical components, and want a clean and bright place operations.
Optical Coating fragile and easy to scratch the surface. You can not use solvents will damage
plastic or colored surfaces.
To maintain proper cooling, it is necessary to periodically dust on the fan and vents
Clean Optical parts
1.Cut off power supply and cool the fixture completely. Open the cover shell
2.Clean the dust with air compressor.
3.With tissue paper stained glass cleaner or pure water, wipe out stubborn stains.
But can not scrape the surface should be rubbed gently repeat.。
4.Cotton with alcohol to remove the soot debris. Also available glass cleaner, but
use pure water to clean the residual. Slowly circle clean from the inside to the outside.
5. With a clean and soft cloth or air compressor to dry.
Clean the fan and vents
With a soft brush, cotton, vacuum cleaner or an air compressor, fan and vents to remove
dust.

19
Aolait lighting CO.,Ltd
No.48 Guanghua Road Xinya Huadu District Guangzhou
Tel:+86 20 61809262/61809261
Fax:+86 20 61809260
E-mail:[email protected]
Web:www.aolait.com
Table of contents