AP-KS9302 system monitoring terminal is the monitoring display of the static electricity monitoring and elimination system produced by Anping
Company (AP&T) which is used to monitor the working status of pulsed DC ionizing blowers, pulsed AC ionizing bars, and electrostatic sensors.
The system monitoring terminal (AP-KS9302), also called IMS intelligent monitor, can provide 4 ways of communication network transmission,
support LAN/WAN connection, flexibly configure real-time monitoring static electricity detection and elimination equipment, and realize power
supply, data interaction, real-time display, linkage, etc.
①Monitoring and display of the working status of electrostatic eliminators and sensors.
②The working status of 4 ways equipment can be monitored simultaneously.③4 ways working status indicator lights, 1 way communication status indicator light, and 1 way power-on indicator light.
④RJ45 power supply and communication port.
⑤RS485 and wireless communication function.
Specifications
Specifications
NO. Parameter
1 Adapter IN:AC85-240V OUT:24V 2A
2 Dimensions 100*120*25
3Indication LED
4 Digital display 3.5 inch COG,monochrome
5 Working environment Temperature:0-50℃;Humidity:30-70%RH
6 Product network port 4 ways:P1-P4
7 Network port definition
1、23 4 5、6、97 8
White-orange/orange White-blue Blue White-green/green White-brown brown
VCC RS485_B RS485_A GND、PE NPN-C1 NPN-C2
8 Communication network port WAN/LAN
9 Power network port POWER
10 Net weight 400g
11 Gross weight 500g
Function
NO. Parameter
1 Network port
POWER Power port(with RS485 communication method)
P1-P4 Note 1 Eliminator or sensor
WAN/LAN Note 2 Ethernet connection
2 LED P1-P4
Red light Eliminator Flashing
Sensor
Green light
Eliminator Always on
Sensor
Eliminator Flashing
Note
1、P1 - P4 : Only 2 eliminators can be connected due to power limit of power supply
2、WAN/LAN : The power supply cannot be connected to this network port, otherwise the wireless module will be damaged
Product Description
Product Features
High voltage indication
Threshold indication
Power-on indication
Cleaning indication

Network port cable function information
1、2Orange/White-orange VCC:+24VDC
3 Blue RS485+B
4 White-blue RS485+A
5 Green GND
6 White-green GND
7 Brown
8 White-brown
9 Metal shield PE
IMS Smart Controller
WAN/LAN P4
P3P2P1 POWER
P1-P4 : 1/2 -VCC 3-RS485_B 4-RS 485_A 5/6-G ND 7-C_V
TH
/HV
AL
8-C_ACT/Clean 9-PE(Metal shield)
P1 P2
P4
P3
Red-V
TH
/HV
AL
ACT/Clean-Green ACTWrok/Link
NEXT
SCAN
NEXT
LINK
B
SET
S
SCROLL
T
RJ45 port
LCD
2.4G communication antenna
Electrostatic sensor monitoring settings
Wireless connection Temperature and humidity display
WAN/LAN
:
Ethernet connection port
POWER:Monitor power port (with
RS485 communication)
P1→P4:The working status monitoring and
power supply port of the eliminator or sensor
M4 mounting hole Temperature and humidity detection window
Electrostatic eliminator running time setting
Electrostatic eliminator monitoring settings
ACT:Monitor power-on indication, green light always on
Work/Link:
Network connection:red light flashing, green light always on
Network disconnection:red light flashing, green light off
P1→P4:4 ways status indicator light
Red light flashing: Sensor threshold alarm/eliminator high voltage alarm
Green light always on: Sensor/eliminator power-on indication
Green light flashing: Eliminator cleaning indication
Function introduction
Function diagram
Network port cable function information
VTH:Sensor threshold alarm
HVAL:Eliminator high voltage alarm
ACT:Sensor/eliminator power-on indication
Clean:Eliminator cleaning indication

Function description table
Antenna(2.4G)
Temperature and humidity sensor
P1-P4
aFour electrostatic sensors
b Two electrostatic sensors, two electrostatic eliminators
NEXT Short press - select product (an electrostatic sensor that must be linked)
S Product - Electrostatic Sensor
SCAN Long press - search for products
SET Short press - select time(10S、20s、30S、60S、90S、120S、360S)
TTime - running time of electrostatic eliminator
SCROLL Long press - quickly adjust the time
NEXT Short press - select (an electrostatic eliminator)
B Product - Electrostatic Eliminator
LINK Long press - linkage (linkage control of electrostatic sensor and electrostatic eliminator)
Red-VTH/HVAL
HVAL Electrostatic eliminator high voltage alarm indication
VTH Electrostatic sensor threshold alarm indication
Red Red light indication
ACT/Clean-Green
Green Green light indication
ACT Product online indication
Clean Electrostatic eliminator cleaning indication
WAN/LAN Ethernet connection method (default LAN)
Wrok/Link
WorkRed light flashes - standby, red light off - no power supply or module damage
Link Green light off - disconnected, green light always on - connected
POWER DC - 24/2A
ACT Green light always on - connected to the power supply
Function introduction
①The upper right corner of the IMS intelligent monitor screen displays the ambient temperature and humidity in real time.
②The network port POWER is the power supply port of the IMS intelligent monitor. The green light is on for normal power supply, P1-P4 are
the power supply and data monitoring ports for external products, and AL1-AL4 indicate the working status of the external product, the green
light is always on for normal while red light is on for abnormal.
③The LINK indicator light shows the WIFI connection status of the IMS intelligent monitor. The red light keeps flashing when the module is
working normally, and the green light is on when the connection is successful while the green light is off when the connection is disconnected.
④SCAN Long press to search the device and short press to light up the screen.
⑤LINK Long press to jump to the setting interface.
⑥Short press SCAN - NEXT to link the electrostatic elimination equipment and sensor.
⑦Short press SCROLL - SET to set the elimination time.
⑧Short press LINK - NEXT to switch to the next setting.
NEXT
SCAN
S
SET
SCROLL
T
NEXT
LINK
B

Search equipment
Long press the SCAN button to search for equipments after turning on the power, and the online connected equipments will be displayed after 10S.
Connect two electrostatic sensors and two power elimination equipments as shown in the figure below and press to display (Sensor-001/Sensor-003/
Bar-001/Blower-001).
Abnormal alarm
The IMS intelligent monitor is connected through RJ45 to RJ45, one end is connected to detection equipment and elimination equipment, and one end
is inserted into the RJ45 adapter terminal to connect to the sound and light alarm. The sound and light alarm is in red light and accompanied by the
buzzing sound when the sensor or elimination equipment is abnormal.
Power supply
Adapter
RJ45 To RJ45
RJ45 transfer terminal
Sound and light alarm
Sensor
Power supply
Detected object
•Installation Guide
Linkage equipment
Long press LINK to jump to the setting interface, short press SCAN - NEXT to link electrostatic equipment and sensor, short press SCROLL -
SET to set the elimination time (delay time 10S-360S), short press LINK - NEXT to jump to the next setting page. Set up the linkage equipment
between the electrostatic sensor and the elimination equipment as shown in the figure below.
Handheld Terminal
,RQEDU
OR
OR
Detected object
Host-slave mode
① Host mode
The IMS intelligent monitor supports reading the work information of
external static electricity detection equipment and static electricity
elimination equipment, and can link and set related operations of
static electricity elimination products in the host mode.
② Slave mode
The IMS intelligent monitor is connected to the computer via WIFI/
RJ45 in the IMS software in which the static electricity detection and
elimination of the IMS intelligent monitor can be conducted when the
IMS intelligent monitor is in PC slave mode.
Power supply
Detected object
Power supply
Detected object
RJ45 transfer terminal interface definition

Dimensions
Maintenance
It should be stopped and repaired by professional maintenance personnel if the display or working status indicator on the panel is off when the system
monitoring terminal is confirmed to be connected to the equipment correctly and the power supply is normal. It can be used only after the electrical
performance indicators are normal.
After-sales service
①Manual ×1 ② Certificate of conformity ×1 ③ Power Adapter ×1 ④ National standard power cord ×1 ⑤ Power network cable ×2
100
120
52
76
87.5
14
14 4
25
IMS Smart Controller
WAN/LAN P4P3P2P1 POWER
P1-P4 : 1/2-VCC 3-RS485_B 4-RS485_A 5/6-GND 7-C_V
TH
/HV
AL
8-C_ACT/Clean 9-PE(Metalshield)
P1 P2
P4
P3
Red-V
TH
/HV
AL
ACT/Clean-Green ACTWrok/Link
NEXT
SCAN
NEXT
LINK
B
SET
S
SCROLL
T
Packing accessories
1. System monitoring terminal has undergone rigorous testing and aging treatment before ex-work. Its performance has completely reached the
relevant indicators marked in the usage instruction.
2. AP&T makes a commitment to the customer that any defective parts inspected by AP&T will be repaired or replaced free of charge within one
year from the date of purchase. However, this commitment does not apply to:
(1) The device is incorrectly used or installed.
(2) Damage caused by negligence or accident during use.
(3) Modified, disassembled or repaired by other service departments not authorized by Anping Company.
3. AP&T shall not be liable for any incorrect use of the products except for repair or replacement of parts as specified above.
Warning
Safety warning
•Please read the instruction manual carefully before installing and using this equipment.
•The working input power must be reliably connected to the grounding wire of the electrical power supply cable and the grounding resistance should
be less than 4 ohm; Otherwise, it is easy to cause abnormal or even damage of the equipment.
•Do not use this equipment in environment where humidity is > 70%.
•It is strictly forbidden to use this equipment in flammable and explosive environments.
•Unauthorized disassembly of the product is strictly prohibited, internal maintenance and repair must be performed by professionals.
•It is strictly forbidden to touch liquid during use, otherwise an abnormality may occur and cause electric shock or fire.
•Power must be turned off during inspecting or replacing the product, otherwise it may cause electric shock or fire.
•The product is specially designed for monitoring and eliminating static electricity. It is strictly forbidden to use it for other purposes. Any abnormal
use may cause machine failure, electric shock, fire and other accidents.
•Please check the input voltage before powering on the product. Any power supply that does not meet the specifications will cause damage to the
product.
•Please check the product power cord regularly and replace it immediately if it is damaged. Otherwise it is easy to cause problems such as electric
leakage and abnormal operation.