Jungheinrich WMT 210 User manual

Page 2
v1.1
24.05.2023
LS-Support-Interfaces@jungheinrich.de
Contents
1. Comments...........................................................................4
1.1 General Comments .......................................................................................................4
1.2 Manufacturer .................................................................................................................4
1.3 Data, Images, Changes.................................................................................................4
1.4 Trademark .....................................................................................................................4
1.5 Copyright .......................................................................................................................4
2. General Description............................................................5
2.1 Intended Use.................................................................................................................5
2.2 Improper use .................................................................................................................5
2.3 Environmental Conditions .............................................................................................6
2.4 Conformity .....................................................................................................................6
2.5 Warranty / repairs..........................................................................................................6
2.6 Treatment and disposal of lithium batteries ..................................................................6
2.7 Technical Data - Power supply......................................................................................7
2.8 Technical data –UPS....................................................................................................7
2.9 Type plate......................................................................................................................8
WMT 210.......................................................................................................................8
WMT 215.......................................................................................................................8
3. Scope of delivery................................................................9
4. Mounting and Handling....................................................10
4.1 VESA75 Interface........................................................................................................10
4.2 U-Mount Interface........................................................................................................10
4.3 Opening the service slot..............................................................................................10
4.4 Interface Overview.......................................................................................................11
WMT 210.....................................................................................................................11
WMT 215.....................................................................................................................12
Power supply connector..............................................................................................13
Ignition (IGN) ...............................................................................................................13
4.5 Antennas WLAN and Bluetooth...................................................................................13
5. Start-up..............................................................................14
5.1 Front Keys ...................................................................................................................14
5.2 Users ...........................................................................................................................15
5.3 Windows Setup Wizard ...............................................................................................15
5.4 Wizard Reset...............................................................................................................15
5.5 Partitioning...................................................................................................................15
5.6 Touch calibration.........................................................................................................16
5.7 UPS - Uninterruptible Power Supply (optional)...........................................................16
6. Configuration Center........................................................17

Page 3
v1.1
24.05.2023
LS-Support-Interfaces@jungheinrich.de
6.1 System Information......................................................................................................18
6.2 Ignition Key..................................................................................................................19
6.3 Wireless Connections..................................................................................................20
6.4 Backup and Restore....................................................................................................21
6.5 On-Screen Keyboard...................................................................................................22
6.6 Internal Watchdog .......................................................................................................23
6.7 Front buttons ...............................................................................................................24
6.8 USB port blocking........................................................................................................25
6.9 Unified Write Filter.......................................................................................................26
6.10 Power On / Power Off .................................................................................................27
6.11 Serial Port Wedge .......................................................................................................28
6.12 Adaptive brightness and adjustment...........................................................................30
7. Jungheinrich Image: Windows Standard 10 IoT Enterprise
2019/2021 LTSC ................................................................31
7.1 Windows Updates........................................................................................................31
7.2 Pre-installed third-party software.................................................................................31
8. BIOS...................................................................................32
8.1 Navigation in BIOS......................................................................................................32
Activating/deactivating interfaces................................................................................33
9. Installation, Backup and Restore.....................................34
9.1 Backup.........................................................................................................................34
9.2 Restore........................................................................................................................35
Restore from Windows................................................................................................35
Restore from boot menu (at least Image V4.1)...........................................................35
9.3Installation with USB-Stick ..........................................................................................36
Rquirments ..................................................................................................................36
Create the bootable USB-Stick from configuration center ..........................................36
Create the bootable USB-Stick with a PC...................................................................36
Save the image on the bootable USB-Stick................................................................36
Installation from USB-Stick..........................................................................................37
10. Change history..................................................................38

Page 4
v1.1
24.05.2023
LS-Support-Interfaces@jungheinrich.de
1. Comments
1.1 General Comments
This manual is about administration and usage of the Jungheinrich truck terminals WMT 210 and 215,
referred to in the following as device You can find further information for mounting, cabling and safety-
relevant aspects in the separate available operation instructions.
The original version of this manual is in German. Every non-german version is a translation.
1.2 Manufacturer
Manufacturer of this product is the Jungheinrich AG, referred to in the following as Jungheinrich.
1.3 Data, Images, Changes
All data, images and changes have been created to the best of one’s knowledge and belief. There is
no assurance for any specification. There is no guarantee for integrity and topicality. Subject to change
without prior notice.
1.4 Trademark
All mentioned (soft-/hardware, brands) descriptions are protected by the general trademark right. Other
used foreign brand names are acknowledged. Jungheinrich reserves the right to assert all rights in the
event of a breach of the trademark rights.
1.5 Copyright
This manual is protected by copyright. All entitled users can use this document as part of the purpose
regarding the contract. Every change in usage or recycling of the supplied contents, especially multipli-
cation, changes or publication needs to be approved by Jungheinrich.
Jungheinrich reserves the right to assert rights concerning events of a breach of the copyright.
The copyright of this manual belongs to JUNGHEINRICH AG.
Jungheinrich Aktiengesellschaft
Friedrich-Ebert-Damm 129 - 22047 Hamburg - Deutschland
Telefon: +49 (0) 40/6948-0 - www.jungheinrich.com

Page 5
v1.1
24.05.2023
LS-Support-Interfaces@jungheinrich.de
2. General Description
2.1 Intended Use
The device was specifically developed for use on forklift trucks in logistics and industrial environments.
A further application area is in the production environment where the device is used for stationary vis-
ualisation, control and operating/machine data collection.
The device must be operated and stored under the following conditions:
Temperature during operation -30°C to +50°C
Temperature during storage -40°C to +80°C
Air humidity in operation and storage 10% to 95% without condensate.
The device is protected against dust and jets of water in accordance with protection rating IP65.
Use in areas where there is a risk of explosion is prohibited.
The operator alone shall be responsible for ensuring that all operator obligations are observed and for
complying with any technical or statutory amendments that may arise.
Installation, commissioning and operation may only be performed by qualified and trained personnel.
Intervention by the user is required only for performing the actions described in this document.
Should any further modifications be required, it is necessary to consult either with the manufacturer
directly or with service personnel authorised by the manufacturer.
The device must be de-energised during service work. Appropriate measures must be taken to prevent
electrostatic discharges on components.
The device is only to be assembled, installed and operated within the permissible specifications.
Use in non-specified environments is prohibited.
2.2 Improper use
Operation other than or beyond that described for the device shall be deemed improper use. The device
is not allowed to be used to control vehicles or for applications for which further approvals beyond the
manufacturer's declaration are necessary, e.g. applications with explosion hazard, medical technology
and shipping industry. The device must not be put into operation in the case of transport damage or
nonconformity with the specifications and must be taken out of operation in the case of changing con-
ditions. In the case of improper use, ADS-TEC shall not accept responsibility or liability for injury or
damage that is directly or indirectly attributable to the handling of the device. If the device is opened by
an unauthorised person, the user may be subject to hazards and the warranty is invalidated. Should
the device have evident signs of damages caused, e.g., by improper operation or storage conditions or
due to improper use or handling, it must be shut down immediately. Ensure that it is secured against
being started up accidentally. The device can be damaged as a result of unauthorised mechanical
modifications. Make sure that the device is not drilled, chiselled or perforated and its exterior shape and
design is not modified in any way!

Page 6
v1.1
24.05.2023
LS-Support-Interfaces@jungheinrich.de
2.3 Environmental Conditions
The device can be operated under the environmental conditions specified in the technical data. Failure to
observe any one of these conditions will invalidate the warranty of the device. Jungheinric cannot be held
liable for any damages arising from improper use and handling.
HINWEIS - condensation
If the temperature of the device is different to that of the environment in which it is located, con-
densation can form.
Switch on the device only after it has acclimated to the ambient temperature.
HINWEIS - Heat
If the device is exposed to sunlight or any other light or heat source, it can overheat and suffer
damage.
If the device is installed in a panel, casing or similar, heat accumulation can occur.
Make sure that heat can be dissipated from the device and do not expose the device to direct
radiation by sunlight or any other light or heat source.
2.4 Conformity
Regarding conformity, please observe the information in the operating instructions enclosed with the
device.
The complete text of the EU declaration of conformity is available at the following Internet address:
www.jungheinrich.com/declaration-of-conformity
2.5 Warranty / repairs
During the device warranty period, any repairs must only be performed by the manufacturer or by ser-
vice personnel that has been authorised by the manufacturer.
2.6 Treatment and disposal of lithium batteries
The device contains a lithium battery to power the system clock and an optionally available uninterrupti-
ble power supply - UPS. The batteries have a service life of approx. 5 years under normal load.
The used lithium battery should be disposed of in accordance with local legal regulations.

Page 7
v1.1
24.05.2023
LS-Support-Interfaces@jungheinrich.de
2.7 Technical Data - Power supply
Power Supply
Nominal voltage
12 - 48 V DC
Range of tolerance
9 –72 V DC
Power consumption
Typical
25 W
Maximum
58 W, 64 W with UPS battery
Closed current
max. 10mA at 9 V
2.8 Technical data –UPS
Uninterruptible power supply
Operating temperature
Charging: 0…50 °C)
The batteries cannot be charged at cell temperatures below 0 °C.
Discharging: 0…60 °C)
Storage temperature
-20 –45 °C
Backup power time (typical)
Depending on the load, at least 15 minutes
Max. power
40 W
Weightt
0,42 kg

Page 8
v1.1
24.05.2023
LS-Support-Interfaces@jungheinrich.de
2.9 Type plate
WMT 210
No.
Description
1
Feature number
2
Production year and calendar week
3
Serial number (also as barcode above)
4
WLAN MAC address (also as barcode above)
5
Input voltage and maximum power consumption
6
Manufacturer
WMT 215
No.
Description
1
Feature number
2
Production year and calendar week
3
Input voltage and maximum power consumption
4
Serial number (also as barcode above)
5
WLAN MAC address (also as barcode above)
6
Manufacturer

Page 9
v1.1
24.05.2023
LS-Support-Interfaces@jungheinrich.de
3. Scope of delivery
Check that the contents of the packaging are intact: If you find any damage, the device must not be put
into operation. Please contact the manufacturer immediately.
Check the contents of the packaging for completeness regarding your order:
•1 x device
•1 x 4-pin plug for power supply in the service duct
•Operating instructions
•Accessories according to order/delivery note

Page 10
v1.1
24.05.2023
LS-Support-Interfaces@jungheinrich.de
4. Mounting and Handling
WMT 210
WMT 215
4.1 VESA75 Interface
VESA75 hole pattern according to illustration, position 4.
- Horizontal and vertical distance between the screw holes: 75 mm
- Thread: M6, torque: 8 Nm (recommended)
- Screw-in depth in the threaded bushings: max. 6 mm
4.2 U-Mount Interface
Mount the retaining bracket (see illustration, position 6) on the device using the screws supplied in the
following order from the inside to the outside:
Nord-Lock washer -> bracket -> Nord-Lock washer -> Allen screw (SW 6 mm) -> cover cap.
4.3 Opening the service slot
NOTE
The relevant safety measures must be observed at all times when handling electrostatically haz-
ardous components. (DIN EN61340-5-1 / DIN EN 61340-5-2).
Remove the 6 screws of the service slot cover (see illustration, position 5) with a Torx Tx10 screw-
driver.
Remove the service slot cover from the device.

Page 11
v1.1
24.05.2023
LS-Support-Interfaces@jungheinrich.de
4.4 Interface Overview
WMT 210
No.
Description
1
Switch for autostart (OFF:ON) –standard: off
2
Power supply (PE –0 VDC –Ignition - +12 to +48 VDC)
3
Grounding (PE) –1,5mm² flat plug contact
4
COM2 (RS232)
5
COM1 (RS232) with optional 5V power supply on pin 9
6
2 x Ethernet 10/100/1000 Mbit RJ45
7
Connection socket (RP-SMA male) for external WLAN antenna (activated via configuration center)
8
3 x Type A USB 3.0
9
Connection for UPS (uninterruptible power supply)
10
Use grommets to ensure IP65 protection. The grommets have a slot on the side for insertingthe cables.
For strain relief, an additional cable tie can be attached over the corresponding opening on the outside.

Page 12
v1.1
24.05.2023
LS-Support-Interfaces@jungheinrich.de
WMT 215
Nr.
Beschreibung
1
Power supply (PE –0 VDC –Ignition - +12 to +48 VDC)
2
Switch for autostart (OFF:ON) –standard: off
3
Connection for UPS (uninterruptible power supply)
4
Optional: Connection socket (SMA female) for external GPS antenna
5
Connection socket (RP-SMA male) for external WLAN antenna (activated via configuration center)
6
Grounding (PE) –1,5mm² flat plug contact
7
2 x Ethernet 10/100/1000 Mbit RJ45
8
COM1 (RS232) with optional 5V power supply on pin 9
9
Switch for power supply 5V on COM1
10
3 x Type A USB 3.0
11
COM2 (RS232)
12
Use grommets to ensure IP65 protection. The grommets have aslot on theside forinserting the cables.
For strain relief, an additional cable tie can be attached over the corresponding opening on the outside.

Page 13
v1.1
24.05.2023
LS-Support-Interfaces@jungheinrich.de
Power supply connector
The device is supplied with 12 V to 48 V DC via a 4-pole
plug (Phoenix Contact MC 1.5/ 4-STF-3.81), depending
on the version.
1. PE
2. 0 V DC
3. Ignition (+12 bis 48 V DC)
4. +12 bis 48 V DC
NOTE –PE Protective earth and fuse
The protective earth conductor must always be attached.
Without a protective earth conductor, there is a risk of overvoltage on the device.
The power supply must be provided with a fuse:
7 A at 12 V DC; 4 A at 24 V DC; 2 A at 48 V DC.
Ignition (IGN)
The device starts automatically when the voltage is applied to the Ignition input.
The supply voltage must be constant. The permissible voltage at the IGN input corresponds to the
supply voltage of the device.
Further reactions to state changes at the Ignition input can be defined in the corresponding module of
the Configuration Center, see section 6.2.
4.5 Antennas WLAN and Bluetooth
The two antennas for 2.4 and 5 GHz WLAN and Bluetooth are protected behind the two plastic covers
on the back of the device.
Avoid covering the antennas with metal parts during installation.
WMT 210
WMT 215
The option "external antenna" deactivates the internal antenna at the rear right (2) and offers it exter-
nally in the service slot via an R-SMA connector.

Page 14
v1.1
24.05.2023
LS-Support-Interfaces@jungheinrich.de
5. Start-up
After the device has been connected to the voltage source and the service slot has been closed again,
the device can be put into operation.
When the device is switched on for the first time, it automatically starts the start-up wizard of the oper-
ating system.
To do this, press the power-on button on the front for approx. 1 second.
5.1 Front Keys
The front keys can be individually configured in the Configuration Center. They have the following
functions ex-factory:
Power button.
To avoid unintentional actuation, press the button for at least 1
second.
Shift key (Function) for the second keyboard level.
The key is pressed, then the corresponding function key can be
pressed.
Standard:
Cancellation of the respective action (ESC)
FN:
Decrease screen brightness
Standard:
Navigation up (arrow up)
FN:
Increase screen brightness
Standard:
Navigation down (arrow down)
FN:
Decrease volume
Standard:
Confirmation of the respective action (Enter)
FN:
Increase volume
Except for the FN key and the power button, all keys can be individually configured via the Configuration
Center.
NOTE
The assignment of the front keys in the BIOS differs from that in the operating system. See chapter
8.

Page 15
v1.1
24.05.2023
LS-Support-Interfaces@jungheinrich.de
5.2 Users
There are 2 Users preset in the Windows operating system:
Login name: User
User group: Users
Password: user
Login Name: Admin
User Group: Administrators
Password: jhwmt
An autologon is activated for the user "User":
5.3 Windows Setup Wizard
The Windows Setup Wizard is used for initial setup and is automatically executed when the device is
started for the first time.
The following settings must be made:
- Language
- Region
- Keyboard layout
- Alternate keyboard layout
- Accept the Windows 10 licence agreement
After completing the wizard, 2 reboots are performed and the final configuration scripts are run.
5.4 Wizard Reset
With the script "reset_image_for_customer" in the path C:\Program Files\Jungheinrich\ResetImage, the
Windows Setup Wizard can be reset and restarted.
5.5 Partitioning
The devices are always equipped with a 64GB eMMC mass storage and optionally with an additional
128GB SSD.
NOTE
Change Autologon:
To change the autologon user, e.g. after an Active Directory domain integration, the Autologon
settings can be changed in the registry as follows:
Registry-Path
[HKLM\Software\Microsoft\Windows NT\CurrentVersion\winlogon]
Name
Type
Value
Default
Description
AutoAdminLogon
REG_SZ
0 (off) / 1 (on)
1
Enable/disable automatic login
DefaultUserName
REG_SZ
<string>
user
User name for autologon
DefaultPassword
REG_SZ
<string>
user
password for autologon
DefaultDomainName
REG_SZ
<string>
<<leer>>
Domain name (if domain member)

Page 16
v1.1
24.05.2023
LS-Support-Interfaces@jungheinrich.de
In the basic version, the 64 GB eMMC is partitioned as follows:
1. 37 GB - WINDOWS (C:)
2. 10 GB –DATA (D:)
3. 12 GB –Recovery partition
4. 0,25 GB –EFI system partition
In the version with an additional 128GB SSD, the following partitioning is carried out:
1. [eMMC] 0,25 GB –EFI system partition
2. [eMMC] 59 GB –WINDOWS (C:)
3. [SSD] 96 GB –DATA (D:)
4. [SSD] 32 GB - Recovery partition
5.6 Touch calibration
The touchscreens are controlled and configured with the driver integrated in Windows ("Tablet PC set-
tings"). The calibration of the touch screen can also be achieved via the control panel ("Calibrate screen
for pen and finger inputs").
5.7 UPS - Uninterruptible Power Supply (optional)
On request, the devices can be supplied with a buffer battery integrated in the service shaft cover.
This buffer battery ensures the operability of the system in the event of short-term power failures. In the
event of longer power failures, the system can be shut down automatically after saving the data.
Due to its limited capacity, the UPS battery is only suitable for bridging short-term power failures.
Therefore, care should always be taken to keep the energy requirement low during battery operation.
Configuration of the battery operation is done via the power settings of Windows 10.
NOTE
Power failures during system updates can damage the operating system.
We strongly advise against installing programme updates or even system updates on battery power.
Even if the system shuts down when battery capacity is critical, it cannot be
guaranteed that updates have already been completely installed at this time.

Page 17
v1.1
24.05.2023
LS-Support-Interfaces@jungheinrich.de
6. Configuration Center
The Configuration Center is used to configure the device-specific settings. It can be started via the
Configuration Center desktop icon.
Administrative rights are required to edit the settings.
The following chapters describe the individual menu items of the Configuration Center.
All settings must always be saved via the diskette symbol at the top right before they become active.

Page 19
v1.1
24.05.2023
LS-Support-Interfaces@jungheinrich.de
6.2 Ignition Key
The device has the option of being started or locked by means of an additional signal input. The function
serves to secure the system against unauthorised access and at the same time saves energy when
used in battery-operated vehicles or mobile locations.
Applying a voltage to the enable contact when the vehicle is switched off causes the device to switch
on automatically.
NOTE
If no ignition voltage is applied to the device, activating the ignition function may render the device
unusable until appropriate wiring has been established.