manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Apator
  6. •
  7. Heater
  8. •
  9. Apator E-ITN 40 User manual

Apator E-ITN 40 User manual

E-ITN 40
Electronic heat cost allocator
USER GUIDE
Description and usage
E-ITN 40 is modern electronic device intended for ratio-
based allocation of heat cost in buildings with central heating
system.The heat cost allocator E-ITN 40 uses the two-sensor
measuring principle. One sensor measures the temperature of
the radiator and the second sensor measures the temperature
of the room. Using this principle, allocator ensures exact
measurement of consumption value only when the radiator
really emits heat.
Heat cost allocator E-ITN 40 is equipped with electronic seal.
This seal is able to recognize unauthorized manipulation and
record its exact date. Data about unauthorized manipulation
is transmit in radio signal.
When thermally influenced, allocator is switched to single-
sensor mode. Allocator is switched back to standard two-
sensor mode when thermal influence is finished.
Application
E-ITN 40 is intended to be installed in one-tube horizontal/
vertical and two-tube heating systems with the lowest mean
design heating medium temperature ≥ 35°C and highest
mean design heating medium temperature ≤ 105°C.
E-ITN 40 is not intended for heat cost allocation for floor he-
ating systems, ceiling radiant heating, flap controlled radia-
tors, radiators with fan, systems with steam heating medium,
air heaters and single tube radiators if exceeds the scope of
one user. It must not be also used for heating elements that
shape and design does not allow reliable transfer of heat to
heat cost allocators.
Each radiator in billing (account) unit with common invoicing
heat meter must be equipped with a heat cost allocator of the
same type. Technical conditions of heating system must be
fulfilled when using heat cost allocators E-ITN 40.
Installation of E-ITN 40
1. Install base plate to the radiator according to the instruc-
tions in Installation and service manual.
2. Place allocator at the upper end of the aluminium back pla-
te, push it down so that the locks in the housing fit in the
aluminium back plate and push the bottom part of alloca-
tor towards back plate. Allocator must be fixed with the
latch on both sides of back plate.
Do not install allocator if notice Error or Open is displayed on LCD.
Dane techniczne
Application
(heating medium)
tmax < 105°C
tmin > 35°C
Measuring principle
Billing period
two-sensor meas. principle yearly or
monthly (customer defined)
Dimensions 100 x 41 x 31 mm
Operating frequency 868 MHz
Transmitting power < 15 mW
Conditions registration
- temperature of the sensor of for the
radiator temp. ≥ 23°C
- difference of mean temp.of heating
medium and surroundings temp. ≥ 4°C
Material ABS + PC / Al – F22
IP code IP42
Conformity ČSN EN 834
Activation of E-ITN 40
If the sign uPr is displayed on LCD, the allocator must be ac-
tivated:
1. When LCD is on and notice uPr is displayed,hold the button
till notice --A-- appears that indicates submenu activation.
2. Switch to item Act with short button presses if necessary.
3. When notice Act appears, press and hold the button till
notice --A-- is displayed. When you release the button,
Start item is displayed, press button again to show the
first menu items.
You can also activate allocator using a phone with Radio Ad-
min app using NFC or RFU 40.
Reading of measured data
Basic allocator status and measured values can be displayed
on LCD. LCD can display five alphanumeric characters. These
values are highlighted by underline and overline, e.g. oPEn.
Meaning of some values may be different if the additional
symbol „SM“ at the right bottom corner is displayed. These
values are mentioned with „SM“symbol in text ,e.g. 385 SM.
Dimensional drawings
Displayed data
Serial number (scrolled)
Billing period
Current yearly billing period consumption
Previous yearly billing period consumption
Current monthly billing period consumption
Past monthly billing period consumption
Also other items can be displayed based on setting
0101-0...
u01.01
0
0 SM
0.
0. SM
To save the battery, after longer period of inactivity (approx. 1
min.),energy-saving mode is activated and display is switched
off. Display can be activated by pushing the button.
When pushing the button briefly, notice ----- on the display
will appear. If the button is not pushed in 1 minute,the display
will switch off.
Transport and storage
Transport
devices can be transported by all usual covered means of
transport
devices must be in original package
originally packed devices must be stored and secured to
avoid mechanical damages during transportation
devices can not be transported together with aggressive
substances
temperature during transportation from 0°C to +55°C
relative humidity from 45% to 75%
Storage
devices must be originally packed by manufacturer and in-
dividually stored in antistatic bags
storage temperature from +10°C to +30°C
relative humidity from 45% to 75%
devices must be stored in clean covered areas without ag-
gressive substances and stored properly to avoid mecha-
nical damage
Disposal
This device is subject to a waste management in accor-
dance with local legislation.
Possible minor faults and their elimination
Any E-ITN 40 defects should be repaired by manufacturer only.
Warranty terms and conditions
If device is installed and handled according to manufacturer instructions mentioned in Installation and service manual,
manufacturer provide warranty under the valid legislation unless agreed differently.
The warranty is void if device was used contrary to Installation and service manual or damaged:
during transport or storage by customer or reseller,
when mounted or dismantled to the customer device,
because of improper handling or installation into other device than agreed in manual,
if the product was exposed to different environment than agreed in manual,
if mechanically or in other way damaged by user.
www.apator.com 2023.001.I.EN
Apator Powogaz S.A.
Jaryszki 1c, 62-023 Żerniki
Sekretariat: sekretariat.powogaz@apator.com, tel. +48 61 84 18 101
Dział Handlowy/Obsługa klienta: tel: +48 61 84 18 149
Wsparcie BOK: handel.powogaz@apator.com
Dział Eksportu: export.powogaz@apator.com
Wsparcie Techniczne: support.powogaz@apator.com, tel. +48 61 8418 131, 134, 294
Reklamacje: reklamacje.powogaz@apator.com

Popular Heater manuals by other brands

Gabarron Elnur RBC11 Installation instructions and user guide

Gabarron

Gabarron Elnur RBC11 Installation instructions and user guide

Stelrad ELECTRIC Series quick start guide

Stelrad

Stelrad ELECTRIC Series quick start guide

usha FH 3213-H instruction manual

usha

usha FH 3213-H instruction manual

ElectrIQ EDR-TRD1025B user manual

ElectrIQ

ElectrIQ EDR-TRD1025B user manual

Solpal L Installation and operating manual

Solpal

Solpal L Installation and operating manual

Dyna-Glo EG4800DGP Installation & maintenance instructions

Dyna-Glo

Dyna-Glo EG4800DGP Installation & maintenance instructions

Stover R 282 C instruction manual

Stover

Stover R 282 C instruction manual

DAY 78714 instruction manual

DAY

DAY 78714 instruction manual

Induction Innovations Mini-Ductor II MD-800 quick start guide

Induction Innovations

Induction Innovations Mini-Ductor II MD-800 quick start guide

Trotec IRS 2000 E manual

Trotec

Trotec IRS 2000 E manual

Vapac LR10 Operation manual

Vapac

Vapac LR10 Operation manual

Flagro F-1500T Operating instructions manual

Flagro

Flagro F-1500T Operating instructions manual

MCS B 35 CEG User and Maintenance Book

MCS

MCS B 35 CEG User and Maintenance Book

Frico SWX EX22 Installation and maintenance instructions

Frico

Frico SWX EX22 Installation and maintenance instructions

Perel SMART1310 user manual

Perel

Perel SMART1310 user manual

Warmlite WL42006 Safety & instruction manual

Warmlite

Warmlite WL42006 Safety & instruction manual

SAMES KREMLIN MAGMA 500 manual

SAMES KREMLIN

SAMES KREMLIN MAGMA 500 manual

German pool EFB-326H user manual

German pool

German pool EFB-326H user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.