Porter Cable| Kerosene Forced Air Heater Operating Instructions and Owner’s Manual
3
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
SPECIFICATIONS
OPERATING PRECAUTIONS
Thisisakerosene,direct-fired,forcedairheater.It’sintendeduse
isprimarilytemporaryheatingofbuildingsunderconstruction,
alterationorrepair.
Direct-Firedmeansthatallofthecombustionproductsenterthe
heatedspace.Eventhoughthisheateroperatesverycloseto100
percentcombustionefficiency,itstillproducessmallamounts
ofcarbonmonoxide.Carbonmonoxide(calledCO)istoxic.CO
canbuildupinaheatedspaceandfailuretoprovideadequate
ventilationcouldresultindeath.Thesymptomsofinadequate
ventilationare:
• headache
• dizziness
• burningeyesandnose
• nausea
• drymouthorsorethroat
BesuretofollowadviceaboutventilationintheSafety
Precautionssection.
ForcedAirmeansthatablowerorfanpushestheairthroughthe
heater.Propercombustiondependsuponthisairflow;therefore,
theheatermustnotberevised,modifiedoroperatedwith
partsremovedormissing.Likewise,safetysystemsmustnotbe
circumventedormodifiedinordertooperatetheheater.
Whentheheateristobeoperatedinthepresenceofotherpeople
theuserisresponsibleforproperlyacquaintingthosepresent
withthesafetyprecautionsandinstructions,andofthehazards
involved.
SAFETY PRECAUTIONS
1. RecommendedforusewithNo.1-Kkerosenefuel.Factorytested
forusewithNo.2-Kkerosene,No.1orNo.2Diesel,No.1orNo.2
fueloilorJP8JetAfuelandthesefuelsmaybeusedaswell.Never
usegasoline,biodiesel,oildrainedfromcrankcases,naphtha,
paintthinners,alcoholoranyotherhighlyflammablefuels.
2. Checktheheaterthoroughlyfordamage.DONOToperatea
damagedheater.
3. DONOTmodifytheheateroroperateaheaterwhichhasbeen
modifiedfromitsoriginalcondition.
4. Suitableforeitheroutdoororindoorusewhereadequate
ventilationisprovided.Neveruseinareasnormallyfor
habitation.Notforusewhereexposedtoweather.
5. Useinwellventilatedareas,provideatleast2sq.ft.(0.19
sq.m.)ofopeningnearthefloorand2sq.ft.(0.19sq.m.)
neartheceilingdirectlytooutdoors.Increaseairopeningsas
markedforeachadditionalheater.
6. Alwayskeepcombustibles,likepaperandwoodatleast8
ft.(2.4m)fromtheheateroutletand3ft.(1.0m)from
thetop,sidesandinlet.Locate10ft.(3.0m)fromcanvas
orplasticcoveringsandsecurethemtopreventflapping
movement.
7. Caution:Duetothehighsurfaceandexhausttemperatures,
adultsandchildrenmustobserveclearancestoavoidburns
orclothingignition.DoNotTouch.Keepchildren,clothing,
andcombustibleaway.
8. Installtheheatersuchthatitisnotdirectlyexposedtowater
spray,rainand/orwater.
9. Neveruseinareasnormallyforhabitationand/orwhere
childrenmaybepresent.
10. Operateonlyonastable,levelsurface.(PCXH80KT–See
woodfloorwarning).
11. Donotusewithductwork.Donotrestrictinletorexit.
12. Useonlywithelectricalpowerspecified.Theelectrical
connectionandgroundingmustcomplywithNational
ElectricalCode–ANSI/NFPA70(USA)andCSAC22.1
CanadianElectricalCode,Part1(Canada).
13. Useonlyaproperlygrounded3-prongreceptacleor
extensioncord.
14. Donotmove,handle,orservicewhilehotorinoperation.
15. Useonlyinaccordancewithlocal,state(provincial)or
nationalrequirements,ordinancesandcodes.
CAUTION: CSA certified for use with only No. 1-K kerosene fuel.
Factory Tested: Kerosene, Diesel #1 and #2, Fuel Oil #1 and #2, JP8 (Jet A Fuel), Biodiesel blends B2, B5, B10, and B20
Model 80KT 140KT 210KT
Burn Rate: 80,000 Btu/hr (23.4 kW) 140,000 Btu/hr (41.2 kW) 210,000 Btu/hr (61.5 kW)
Fuel Rate: 0.59 gal/hr (2.2 L/hr) 1.0 gal/hr (3.9 L/hr) 1.6 gal./hr (6.0 L/hr)
Electrical Input: 115V, 60Hz, 4.0a 115V, 60Hz, 5.5 A 115V, 60Hz, 5.5 A
Line Protection: 10 amps 10 amps 10 amps
Min. Operating Voltage: 110V 110V 110V
Pressure Setting: 4.2 psig (29 kPa) 6.8 psig (47 kPa) 8.4 psig (58 kPa)
Max. Outlet Temperature: 1300oF (704oC) 1300oF (704oC) 1300oF (704oC)
Fuel Tank Capacity: 6 gallons (22.7 L) 10 gallons (37.9 L) 15 gallons (56.8 L)
Ignition: Direct Spark, Continuous Direct Spark, Continuous Direct Spark, Continuous
Spark Generator: Igniter 16.5 kV, 0.2 A Igniter 16.5 kV, 0.2 A Igniter 16.5 kV, 0.2 A
Primary Safety Control: Solid State Control Solid State Control Solid State Control
Certication: