Porter-Cable PCXH80KT Assembly instructions

PCXH80KT, PCXH140KT,
PCXH210KT
WARNING: If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.
— Donotstoreorusegasolineorotherflammablevaporsandliquidsinthevicinityofthisorany
otherappliance.
— Servicemustbeperformedbyaqualifiedserviceagency.
Thisisanunventedportableheater.Itusesair(oxygen)fromtheareainwhichitisused.Adequate
combustionandventilationairmustbeprovided.Refertopage3.
KEROSENE FORCED-AIR HEATER
OPERATINGINSTRUCTIONSANDOWNER’SMANUAL
READ INSTRUCTIONS CAREFULLY:Readandfollowallinstructions.Placeinstructionsinasafe
placeforfuturereference.Donotallowanyonewhohasnotreadtheseinstructionstoassemble,
light,adjustoroperatetheheater.
Model#
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
27354REVA
PorterCable,4825Highway45North,Jackson,Tennessee38305•888-848-5175

2
Porter Cable | Kerosene Forced Air Heater Operating Instructions and Owner’s Manual
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
CONTENTS
WARNINGS................................................................................. 2
HEATERSPECIFICATIONS............................................................. 3
OPERATINGPRECAUTIONS.......................................................... 3
SAFETYPRECAUTIONS................................................................ 3
OPERATINGINSTRUCTIONS........................................................ 4
MAINTENANCE,STORAGEANDSERVICE................................... 4
TROUBLESHOOTING.................................................................... 6
WIRINGDIAGRAM...................................................................... 7
PARTSLIST.................................................................................. 8
EXPLODEDVIEW......................................................................... 9
WARRANTY...............................................................................12
INSTRUCTIONSFORORDERINGPARTS.......................................12
LANGUAGES
ENGLISH...........................................................................1-12
FRENCH.................................................................................1-12
SPANISH................................................................................1-12
WARNING:
• DONOTUSEGASOLINE,NAPHTHAORVOLATILE
FUELS.
• STOPHEATERBEFOREADDINGFUELS.
• ALWAYSFILLOUTDOORSAWAYFROMOPEN
FLAME.
• DONOTUSEEXTERNALFUELSOURCE.
• DONOTOPERATEHEATERWHEREFLAMMABLE
LIQUIDSORVAPORSMAYBEPRESENT.
• DONOTSTARTHEATERWHENCHAMBERISHOT.
• DONOTSTARTHEATERWHENEXCESSFUELHAS
ACCUMULATEDINTHECHAMBER.
• DONOTPLACECOOKINGUTENSILSONTOPOF
THEHEATER.
• PLUGELECTRICALCORDINTOAPROPERLY
GROUNDEDTHREE-PRONGRECEPTACLE.
GENERAL HAZARD WARNING:
FAILURETOCOMPLYWITHTHEPRECAUTIONSAND
INSTRUCTIONSPROVIDEDWITHTHISHEATER,CAN
RESULTINDEATH,SERIOUSBODILYINJURYAND
PROPERTYLOSSORDAMAGEFROMHAZARDSOF
FIRE,EXPLOSION,BURN,ASPHYXIATION,CARBON
MONOXIDEPOISONING,AND/ORELECTRICALSHOCK.
ONLYPERSONSWHOCANUNDERSTANDANDFOL-
LOWTHEINSTRUCTIONSSHOULDUSEORSERVICE
THISHEATER.
IFYOUNEEDASSISTANCEORHEATERINFORMATION
SUCHASANINSTRUCTIONSMANUAL,LABELS,ETC.
CONTACTTHEMANUFACTURER.
WARNING:
FIRE,BURN,INHALATION,ANDEXPLOSIONHAZARD.
KEEPSOLIDCOMBUSTIBLES,SUCHASBUILDING
MATERIALS,PAPERORCARDBOARD,ASAFEDISTANCE
AWAYFROMTHEHEATERASRECOMMENDEDBYTHE
INSTRUCTIONSNEVERUSETHEHEATERINSPACES
WHICHDOORMAYCONTAINVOLATILEORAIRBORNE
COMBUSTIBLES,ORPRODUCTSSUCHASGASOLINE,
SOLVENTS,PAINTTHINNER,DUSTPARTICLESOR
UNKNOWNCHEMICALS.
WARNING:
COMBUSTIONBY-PRODUCTSPRODUCEDWHENUSING
THISPRODUCTCONTAINCARBONMONOXIDE,A
CHEMICALKNOWNTOTHESTATEOFCALIFORNIA
TOCAUSECANCERANDBIRTHDEFECTS(OROTHER
REPRODUCTIVEHARM).
THISPRODUCTCONTAINSCHEMICALSKNOWNTOTHE
STATEOFCALIFORNIATOCAUSECANCERANDBIRTH
DEFECTSOROTHERREPRODUCTIVEHARM.
WARNING:
NOTFORHOMEORRECREATIONALVEHICLEUSE
WARNING:
YOURSAFETYISIMPORTANTTOYOUANDTO
OTHERS,SOPLEASEREADTHESEINSTRUCTIONS
BEFOREYOUOPERATETHISHEATER.
The State of California requires the following warning:
WARNING:
CARBON MONOXIDE CAN KILL YOU
USINGAPORTABLEHEATERINANENCLOSEDAREA
CANPRODUCEDEADLYCARBONMONOXIDE.
PCXH80KT WARNING:
Not suitable for use on wood floors or other
combustible materials. When used the heater
should rest on a suitable insulating material at
least 1 inch thick and extending 3 feet or more
beyond the heater in all directions.

Porter Cable| Kerosene Forced Air Heater Operating Instructions and Owner’s Manual
3
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
SPECIFICATIONS
OPERATING PRECAUTIONS
Thisisakerosene,direct-fired,forcedairheater.It’sintendeduse
isprimarilytemporaryheatingofbuildingsunderconstruction,
alterationorrepair.
Direct-Firedmeansthatallofthecombustionproductsenterthe
heatedspace.Eventhoughthisheateroperatesverycloseto100
percentcombustionefficiency,itstillproducessmallamounts
ofcarbonmonoxide.Carbonmonoxide(calledCO)istoxic.CO
canbuildupinaheatedspaceandfailuretoprovideadequate
ventilationcouldresultindeath.Thesymptomsofinadequate
ventilationare:
• headache
• dizziness
• burningeyesandnose
• nausea
• drymouthorsorethroat
BesuretofollowadviceaboutventilationintheSafety
Precautionssection.
ForcedAirmeansthatablowerorfanpushestheairthroughthe
heater.Propercombustiondependsuponthisairflow;therefore,
theheatermustnotberevised,modifiedoroperatedwith
partsremovedormissing.Likewise,safetysystemsmustnotbe
circumventedormodifiedinordertooperatetheheater.
Whentheheateristobeoperatedinthepresenceofotherpeople
theuserisresponsibleforproperlyacquaintingthosepresent
withthesafetyprecautionsandinstructions,andofthehazards
involved.
SAFETY PRECAUTIONS
1. RecommendedforusewithNo.1-Kkerosenefuel.Factorytested
forusewithNo.2-Kkerosene,No.1orNo.2Diesel,No.1orNo.2
fueloilorJP8JetAfuelandthesefuelsmaybeusedaswell.Never
usegasoline,biodiesel,oildrainedfromcrankcases,naphtha,
paintthinners,alcoholoranyotherhighlyflammablefuels.
2. Checktheheaterthoroughlyfordamage.DONOToperatea
damagedheater.
3. DONOTmodifytheheateroroperateaheaterwhichhasbeen
modifiedfromitsoriginalcondition.
4. Suitableforeitheroutdoororindoorusewhereadequate
ventilationisprovided.Neveruseinareasnormallyfor
habitation.Notforusewhereexposedtoweather.
5. Useinwellventilatedareas,provideatleast2sq.ft.(0.19
sq.m.)ofopeningnearthefloorand2sq.ft.(0.19sq.m.)
neartheceilingdirectlytooutdoors.Increaseairopeningsas
markedforeachadditionalheater.
6. Alwayskeepcombustibles,likepaperandwoodatleast8
ft.(2.4m)fromtheheateroutletand3ft.(1.0m)from
thetop,sidesandinlet.Locate10ft.(3.0m)fromcanvas
orplasticcoveringsandsecurethemtopreventflapping
movement.
7. Caution:Duetothehighsurfaceandexhausttemperatures,
adultsandchildrenmustobserveclearancestoavoidburns
orclothingignition.DoNotTouch.Keepchildren,clothing,
andcombustibleaway.
8. Installtheheatersuchthatitisnotdirectlyexposedtowater
spray,rainand/orwater.
9. Neveruseinareasnormallyforhabitationand/orwhere
childrenmaybepresent.
10. Operateonlyonastable,levelsurface.(PCXH80KT–See
woodfloorwarning).
11. Donotusewithductwork.Donotrestrictinletorexit.
12. Useonlywithelectricalpowerspecified.Theelectrical
connectionandgroundingmustcomplywithNational
ElectricalCode–ANSI/NFPA70(USA)andCSAC22.1
CanadianElectricalCode,Part1(Canada).
13. Useonlyaproperlygrounded3-prongreceptacleor
extensioncord.
14. Donotmove,handle,orservicewhilehotorinoperation.
15. Useonlyinaccordancewithlocal,state(provincial)or
nationalrequirements,ordinancesandcodes.
CAUTION: CSA certified for use with only No. 1-K kerosene fuel.
Factory Tested: Kerosene, Diesel #1 and #2, Fuel Oil #1 and #2, JP8 (Jet A Fuel), Biodiesel blends B2, B5, B10, and B20
Model 80KT 140KT 210KT
Burn Rate: 80,000 Btu/hr (23.4 kW) 140,000 Btu/hr (41.2 kW) 210,000 Btu/hr (61.5 kW)
Fuel Rate: 0.59 gal/hr (2.2 L/hr) 1.0 gal/hr (3.9 L/hr) 1.6 gal./hr (6.0 L/hr)
Electrical Input: 115V, 60Hz, 4.0a 115V, 60Hz, 5.5 A 115V, 60Hz, 5.5 A
Line Protection: 10 amps 10 amps 10 amps
Min. Operating Voltage: 110V 110V 110V
Pressure Setting: 4.2 psig (29 kPa) 6.8 psig (47 kPa) 8.4 psig (58 kPa)
Max. Outlet Temperature: 1300oF (704oC) 1300oF (704oC) 1300oF (704oC)
Fuel Tank Capacity: 6 gallons (22.7 L) 10 gallons (37.9 L) 15 gallons (56.8 L)
Ignition: Direct Spark, Continuous Direct Spark, Continuous Direct Spark, Continuous
Spark Generator: Igniter 16.5 kV, 0.2 A Igniter 16.5 kV, 0.2 A Igniter 16.5 kV, 0.2 A
Primary Safety Control: Solid State Control Solid State Control Solid State Control
Certication:

4
Porter Cable | Kerosene Forced Air Heater Operating Instructions and Owner’s Manual
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
Notes:
• Incoldweather(below10°F),startingmaybeimprovedby
holdingafingerovertheventholeofthepumpadjustment
screwcapuntiltheheaterstarts.
• Thisunitisequippedwithaninterruptcircuit.Theresetis
integratedintothe“On/Off”switch.Iftheunitdoesnot
start,toggletheswitchto“Off”,wait5min.andtoggle
theswitchto“On”.
HEATER SHUT DOWN
1. Push“On/Off”switchto“Off”position.Forextended
shutdown,unplugheaterfrompowersource.
RESTART AFTER SAFETY SHUTDOWN
1. Toggleswitchto“OFF”position,wait5minutes.Restart.
MAINTENANCE AND STORAGE
WARNING.Topreventpersonalinjury,unplugtheheaterfrom
thewalloutletbeforeservicing.
Formaximumefficiencyandtrouble-freeservice,makethe
followingperiodicmaintenance,cleaningandinspections.
ADJUSTING PUMP PRESSURE
Duetovaryingfuelviscositiesandnormalcomponentwearthe
pumppressureonthisheatermayneedtobeadjusted.
FUELPRESSUREADJUSTMENTSCREW
(locatedattherearoftheheater)
PRESSUREGAUGE
ADJUSTMENT PROCEDURE
1. Fillfueltank.
2.Startheater.
3.Locatethepressureadjustmentscrewandpressuretap,
picturedabove,locatedonthebackofthepowerpack
assemblyandaccessiblebythehandleoftheheater.
4.Removeandtherubbercapoverthefuelpressureadjustment
screw.
5.Usingaflatbladedscrewdriver,turnthepumppressure
adjustmentscrew:
•clockwise toincreasepumppressure
•counter-clockwise todecreasepumppressure
Byusingtheinstalledpressuregaugeyoumayquantitatively
calibratethepressure.Themanufacturer’srecommendedpump
pressuresareinthespecificationschartonpage3.
OPERATING INSTRUCTIONS
UNPACKING
1. Removeheaterfromcarton.
2. Removeallprotectivematerialwhichmayhavebeenapplied
totheheaterforshipment.
3. Checktheheaterforpossibleshippingdamage.Ifany
damageisfoundimmediatelycontactthemanufacturerat
888-848-5175.
ASSEMBLY (For140,000and210,000BTU/hrmodelsonly)
Wheels,axle,andhandlesarefoundintheshippingcartonalong
withmountinghardware.
1. Handlescomepre-assembledonthetank.Thetransport
handleandsupportfootsimplysnapintoplace.
2. Toassemblethewheels,firstInstalloneofthelargelocknut
ontotheendoftheaxle.
3. Slideonewheelontotheaxlenexttothenut,thenone
spacer.
4. Slidethepartiallyassembledaxlethroughthewheelsupport
frame.
5. Slidethespacerontotheaxlenexttothewheelsupport.
6. Slidethewheel,thenlargelastlargelocknutontotheaxle.
Usingtwoadjustablewrenchesholdbothnutsandtighten.
DONOTOVERTIGHTEN.
PREPARING FOR OPERATION
1. Checktheheaterforpossibleshippingdamage.Ifanyis
found,immediatelycontactthemanufacturerat
888-848-5175.
2. Followallofthe“Precautions”.
3. Fillthefueltankwithcleankerosene.Inextremelycold
weather,condensationmaydevelopinthetankanditis
recommendedthatatablespoonofde-icerbeaddedfor
eachgallon(3.78Liters)offuelinthetank.Whenfilling
theheater,useatleast2gallons(7.57liters)offuel.Besure
heaterislevelanddonotoverfill.Useafunnelorcanwitha
longfillspout.
IMPORTANT: Before filling fuel tank the first time or after ex-
tended storage periods, drain the fuel tank of any moisture
or condensation.
4. Locateheateratasafedistancefromcombustiblematerials.
ModelPCXH80KTisnotsuitableforuseonwoodfloorsor
othercombustiblematerials.Whenused,theheatershould
restonsuitableinsulatingmaterialatleast1inchthickand
extending3ft.ormorebeyondtheheaterinalldirections.
HEATER START UP
1. Turnthermostattolowestsetting,andmakesure“On/Off”
switchis“Off”.Plugtheheaterintoagrounded115V,60Hz,
1Øoutlet.Turnthermostattohighestsetting.Startheater
bypushingtoggleswitchto“On”position(lightsignifies
switchisin“ON”position).Adjustthermostattodesired
setting.Heaterwillcycleon/offasheatisrequired.
EXTENSIONCORDREQUIREMENTS:Upto100’(30.5m)use
16awg.conductor.101’-200’(30.5-61.0m)use14awg.
conductor.

Porter Cable| Kerosene Forced Air Heater Operating Instructions and Owner’s Manual
5
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
6.Thedesiredqualitativeburnercharacteristicsarethatthenose
coneinthecombustionchambershouldbecherryredwithno
darkspotsandtheflameshouldnotextendbeyondthenose
cone.
IMPROPER PRESSURE ADJUSTMENT
Problem: Heaterdoesnothaveastrongconsistentflame.
Heatersmokesandspitsrawfuel.
Noseconedoesnotgetcherryred.
Adjustment:Pumppressureistoolow.
Turnadjustmentscrewclockwisetoincreasepump
pressure.
Problem: Flameextendsbeyondtheendoftheheater.
Adjustment:Pumppressureistoohigh.
Turnadjustmentscrewcounterclockwiseto
decreasepumppressure.
DAILY SCHEDULE
1. GENERAL.Makegeneralvisualinspectionofheaterforloose
ordamagedparts.Checknutsandboltstoinsureagainst
loosenesscausedbyvibrationorroughhandling.Damaged
partsshouldberepairedorreplacedbeforeusingheater
again.Checkheateroperationtobesureitisoperating
normally(See“Servicing”sectionfordescriptionofnormal
operation).
2. FILTERS.Dirtyairorfuelfilterswillcauseanimbalancein
theair-fuelmixture.Thebestindicationthatthiscondition
existsisanincreaseinodorsordifficultygettingyourheater
toignite.Thisheatershouldneverbeoperatedwithoutthe
filtersinplace.Ifrequired,cleanfiltersasdescribedunder
“500Hours”and“AnnualSchedules”.
500 HOUR SCHEDULE
1. AIRINTAKEFILTER.Removeandwashthefilterelement
withamilddetergent,drythoroughlyandreplace.Donot
oilthefilterelement.Ifyourheaterisusedwherethere
isconsiderabledustordirt,cleanasoftenasnecessary
(approximatelyevery50hrs.).
2. REMOVEDUST.Cleanheatertwiceaseason(moreoften
underdustyconditions).Removeaccumulateddustfromthe
transformer,burner,motorandfanbladeswithcompressed
air.Wipeareacleanwithacleandrycloth.Inspectareato
ensureallforeignmaterialsareremoved,especiallyaround
theburnerandcombustionarea.
3. CADCELL.Cleantheglassportionofthecadcellwithasoft
drycloth.
4. NOZZLE.Accumulationofdirtfromfuelandcarbonfrom
thecompressorvaneswilleventuallyfillupthepassages
inthenozzle,resultinginreductionoffuelandairflow.
Pressurewillgraduallyincreasegivingimproperfuel-air
mixtureandexcessodorandsmoke.Ifthisoccurs,replace
thefuelnozzle.
5. FUELTANK.Cleantwiceaseason(duringfrequentlyused
periods,cleantwiceamonth).Drainandflushthefueltank
withcleanfueloil.
ANNUAL SCHEDULE
1. AIROUTPUTFILTER.Removetheairoutputfilterandtap
thecontaminatedsidegentlyonasolidobjecttoremove
contaminates.Compressedairorliquidsshouldnotbeused
tocleanthisfilter.Reinstallcleanedfilterinfilterbodyinthe
samepositionasitwaswhenremoved.Ifthefilterappears
extremelydirty,replaceitwithanewfilterofthesame
type.Whenreplacingthefiltercover,besurethegasketis
firmlyinplaceandthescrewsinthefiltercoveraretightto
preventairleaks.
2. FUELFILTER.Removethefuelfilterfromfuellineanddirect
compressedairthroughthefilterintheoppositedirection
offuelflow.Safetyglassesshouldbewornwhenusing
compressedair.
3. AIRANDFUELLINES.Iftheairorfuellinesareremoved
duringcleaning,besureallconnectionsaretightbefore
operatingunit.
STORAGE
Storetheheaterinadrylocationfreefromfumesordust.
Attheendofeachheatingseason,cleantheheaterasdescribed
intheMAINTENANCEsection.Drainandflushthefueltankwith
cleanfuel.Themanufacturerrecommendscompletelyfillingthe
tankwithfuelforextendedstoragetominimizecondensation
insidethetank.
Itisrecommendedtoonlystorekeroseneincontainersthatare
marked“KEROSENE”.
SERVICING
Ahazardousconditionmayresultifaheaterisusedthathasbeen
modifiedorisnotfunctioningproperly.
Whentheheaterisworkingnormally:
* Theflameiscontainedwithintheheater.
* Theflameisessentiallyyellow.
* Thereisnostrongdisagreeableodor,eyeburningorother
physicaldiscomfort.
* Thereisnosmokeorsootinternalorexternaltotheheater.
* Therearenounplannedorunexplainedshutdownsofthe
heater.
Digital Thermostat Codes
Code Description
CH Continuous Heat
F2 Thermostat Fault
LO Environment Temperature is below 16�F
HI Environment Temperature is higher than 99�F

6
Porter Cable | Kerosene Forced Air Heater Operating Instructions and Owner’s Manual
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
TROUBLE SHOOTING
SYMPTOM TROUBLE SHOOTING
HighlimitswitchOpenCircuit 1) Makesureheateriscooledoff,toggleswitchto“OFF”position,wait5minutesandretry.
Sparks,callingforflame,but 1) Checkwiringtomotor(perwiringschematicinmanual).
noorslowmotoroperation 2) Makesurethatthepressuregaugeisinplaceandnotdamaged.
3) Adjustpressureforproperheateroperationpermanual.
4) WithheaterdisconnectedfromACsource,rotatefanclockwisetoverifymotorisfree.
5) Removeairfilterhousingfrommotorandinspectthepumprotorfordamage.Ifdamaged,replacerotorassembly.
6) Ifwiringiscorrect,pumprotorisokay,andmotorisnotrotatingfreely,replacemotororpower-packassembly.
7) Ifproblempersists,replaceoilflamecontrolassembly.
8) Checkforsparkarchingfromtheelectrodeassembly,tothecombustioncylinder.
9) Checkthecadcellforcontinuity.
NoSpark 1) Checklengthandgageofextensioncordforproperamp.draw.(Checkrequirementsonpage4.)
2) Checkwiringtoigniter(perwiringschematicinmanual).
3) Checkgapbetweenelectrodeprobes(2.3-3mm).
4) Stillnospark,replaceigniterassembly.
5) Replaceoilflamecontrolassembly.
AbnormalMotorOperation- 1) Motorspeedtoolow(Motorshouldoperateat3450rpm)-Replacemotor.
MotoroverheatsorStops 2) WithheaterdisconnectedfromACsource,rotatefanclockwisetoverifymotorisfree.
3) Removeairfilterhousingfrommotorandinspectthepumprotorfordamage.Ifdamaged,replacerotor
assembly.
4) Ifwiringiscorrect,pumprotorisokay,andmotorisnotrotatingfreely,replacemotororpower-packassembly.
5) Replaceoilflamecontrolassembly.
UnabletoDetectFlame 1) Checkwiringtocadcell(perwiringschematicinmanual).
2) Cleancadcellphotocell.
a) Slidecadcelloutofcadcellholder.
b) Pushthephotocelloutoftheblackrubbercadcellhousingbypushingonthe2purplewires.
c) Cleanthephotocellwithasoftclothandrubbingalcohol.
d) Pullthephotocellbackintothecadcellhousingandreinstallintoholder.
e) Testheater.
3) Iftheheaterstilldoesnotoperate,replacecadcell.
4) Replaceoilflamecontrolassembly.
FlameControlFailure 1) Checkwiringinheater(perwiringschematicinmanual).
2) Replaceoilflamecontrolassembly.

Porter Cable| Kerosene Forced Air Heater Operating Instructions and Owner’s Manual
7
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
The parts lists and wiring diagram show the heater as it was
constructed.Donotuseaheaterwhichisdierentfrom
thatshown.Heaterperformanceiseectedbyairpressure
setting.Ifthereisanyuncertaintyabouttheairpressure
WIRING DIAGRAM
setting, have it checked.
Aheaterwhichisnotworkingrightmustberepaired,butonly
byatrained,experiencedserviceperson.
WHT
RED
BLUE
BROWN
RED

8
Porter Cable | Kerosene Forced Air Heater Operating Instructions and Owner’s Manual
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
PARTS LIST
* Not shown in drawing
REF
#
PART # DESCRIPTION
127175 80KFuelTank
227176 FuelFilterRubberGrommet
327177 FuelGauge
426959 FuelCap
6n/a FrontandBackSaddles
727178 80KLowerBarrel
827179 RubberGrommets
9n/a AirDeflectorFin(see#50)
10 27180 HighLimitSwitchBracket
11 27181 115HighLimitSwitch
12 F226865 CADCellFlameSensor
13 n/a PhotoCell(see#12)
14 27182 IgniterElectrode
15 27183 Nozzleadapter
16 27184 RubberFuelTube
17 27185 RubberAirTube
18 n/a FuelLineClamp
19 27186 80KNozzle
20 27187 80KFrontCover
21 27356 80KTopRearCover
22 27189 80KInletGrill
23 n/a StrainRelief
24 n/a PowerCord
25 2719 0 80KControlSideBlackSaddle
26 27191 IgnitionTransformer
27 27192 80KBlackSaddle
28 n/a FuelFilter(see#70)
29 27163 OBEHandle
30 n/a 80KFAKMotor(see#67)
31 27193 80KMotorBracket
32 27194 80KFanBlade
33 27195 StartCapacitor
REF
#
PART # DESCRIPTION
34 n/a AluminumOutletHousing(see#67)
35 n/a PumpRing(see#67)
36 n/a SichuanRotor(see#67or68)
37 n/a PlasticPumpDriveKey(see#67or68)
38 n/a Vanes(see#67or68)
39 27196 PlasticInletHousing
40 n/a InlethousingGasket(see#70)
41 n/a ClothDustFilter(see#70)
42 n/a SmallMetalMesh
43 27197 Smallfoamfilter
44 n/a SteelBallbearing(see#69)
45 n/a Pressureadjustmentspring(see#69)
46 n/a Nylonplug(see#69)
47 n/a Nylonpumpadjusmentscrew(see#69)
48 n/a FoamFilter(see#70)
49 n/a 80KCombustionTube(see#50)
50 27198 CombustionChamberAssembly
51 2719 9 CircuitBoard
52 2720 0 SinglePolePowerSwitch
53 27201 ThermostatKnob
59 27202 PhotoCellBracket
60 n/a BrassBarbElbow(see#67)
61 n/a TemperatureControlProbePlate
62 27203 CircuitBoardMountingBracket
63 n/a RearGuardMetalClip
64 2720 4 PantekThermostatBoard
66 n/a SaddleMountingStud
67 27205 PowerPackAssembly
68 F226831 RotorKit(rotor,vanes,nyloninsert)
69 F266842 PumpAdjustmentKit
70 F221887 FilterServiceKit

Porter Cable| Kerosene Forced Air Heater Operating Instructions and Owner’s Manual
9
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
Kerosene Forced Air Heater • Model PCXH80KT
Filter Kit

10
Porter Cable | Kerosene Forced Air Heater Operating Instructions and Owner’s Manual
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
PARTS LIST
#14 0 K 210K DESCRIPTION
127225 27226 FuelTank
227176 27176 FuelFilterRubberGrommet
327177 27177 FuelGauge
426959 26959 FuelTankCap
5 n/a n/a RearSaddleBracket
6n/a n/a FrontSaddleMount
727 211 27212 LowerBarrel
827179 27179 Grommet
927180 27180 HighLimitSwitchBracket
10 27181 27181 HighLimitSwitch
11 F226865 F226865 PhotoCellAssembly
12 n/a n/a PhotoCellSensor(see#11)
13 27182 27182 IgniterElectrode
14 27183 27183 NozzleAdapter
15 27231 27231 RubberAirTube
16 27233 27233 RubberFuelTube
17 n/a n/a FuelLineClamp
18 27235 27236 Nozzle
19 27214 27215 FrontCover
20 27357 27358 RearCover
21 27237 27237 InletGrill
22 n/a n/a StrainRelief
23 n/a n/a PowerCord
24 27220 27221 RightSaddle
25 27191 27191 Transformer
26 27223 27224 ControlSideLeftSaddle
27 n/a n/a OilFilter(see#75)
28 27239 27240 WheelAxle
29 27241 27242 Wheel
30 27359 27359 TransportHandle
31 27360 27360 LeftLiftHandle
32 27361 27361 RightLiftHandle
33 27362 27363 FrontLiftHandle
34 27364 27364 LowerFootAdapterTube
35 27365 27365 Foot
36 n/a n/a Motor(see#72)
37 27253 27253 MotorBracket
#14 0 K 210K DESCRIPTION
38 27255 27256 FanBlade
39 27195 271 Capacitor
40 n/a n/a PumpPlate(see#72)
41 n/a n/a PumpRing(see#72)
42 n/a n/a Rotor(see#mand73)
43 n/a n/a PlasticPumpDriveKey(see#72or73)
44 n/a n/a Vanes(see#72or73)
45 n/a n/a PlasticInletHousing(see#72)
46 n/a n/a InletHousingGasket(see#75)
47 n/a n/a Filter(see#75)
49 27197 n/a SmallFoamFilter(see#75)
50 n/a n/a SteelBallBearing(see#74)
51 n/a n/a AdjustmentSpring(see#74)
52 27273 27273 PressureGauge
53 n/a n/a PumpAdjustmentScrew(see#74)
54 n/a n/a LargeDustproofSponge(see#75)
55 27257 27258 CombustionChamberAssembly
56 n/a n/a AirDeflectorAssembly(see#55)
57 2719 9 2719 9 CircuitBoard
58 2720 0 2720 0 SinglePoleSwitch
59 27201 27201 ThermostatKnob
60 27260 27260 HandleTubePlug
61 N/A N/A Gasket
62 27262 27262 DrainPlugwithGasket
63 27202 27202 PhotoCellBracket
64 n/a n/a BrassBarbElbow
65 n/a n/a TemperatureControlProbeClip
66 27203 27203 CircuitBoardBracket
67 27174 2716 0 CordWrap
68 27265 27266 MetalStandoff
69 2720 4 2720 4 ThermostatBoard
70 n/a n/a SpringClip
71 27269 27269 WheelHardwareKit(notpictured)
72 27271 27272 PowerPack
73 F226831 F226831 RotorKit
74 F266842 F266842 AdjustmentKit
75 F221887 F221887 FilterKit

Porter Cable| Kerosene Forced Air Heater Operating Instructions and Owner’s Manual
11
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
Kerosene Forced Air Heater • Models PCXH140KT, PCXH210KT

12
Porter Cable | Kerosene Forced Air Heater Operating Instructions and Owner’s Manual
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
PCXH80KT, PCXH140KT,
PCXH210KT
OPERATING INSTRUCTIONS
AND OWNER’S MANUAL
Model#
PorterCablereservestherighttomakechangesatanytime,withoutnoticeorobliga-
tion,incolors,specifications,accessories,materialsandmodels.
WARNING:
USEONLYMANUFACTURER’SREPLACEMENTPARTS.USEOFANYOTHERPARTS
COULDCAUSEINJURYORDEATH.REPLACEMENTPARTSAREONLYAVAILABLE
DIRECTFROMTHEFACTORYANDMUSTBEINSTALLEDBYAQUALIFIEDSERVICE
AGENCY.
PARTS ORDERING INFORMATION:
PURCHASING: AccessoriesmaybepurchasedatanyPorterCablelocaldealeror
directfromthefactory
FOR INFORMATION REGARDING SERVICE
PleasecallToll-Free888-848-5175
www.portercable.com
Ourofficehoursare8:00AM–5:00PM,EST,MondaythroughFriday.
Pleaseincludethemodelnumber,dateofpurchase,anddescriptionofproblemin
allcommunication.
LIMITED WARRANTY
PorterCablewarrantsitsheatersandaccessoriestobefreefromdefectsinmaterial
andworkmanshipforaperiodof1yearfromdateofpurchase.PorterCablewill
repairorreplacethisproductfreeofchargeifithasbeenproventobedefective
withinthe1-yearperiod,andisreturnedatcustomerexpensewithproofof
purchasetoPorterCablewithinthewarrantyperiod.
Somestatesdonotallowtheexclusionorlimitationofincidentalorconsequential
damages,sotheabovelimitationorexclusionmaynotapplytoyou.ThisWarranty
givesyouspecificlegalrights,andyoumayhaveotherrightswhichvaryfromstate
tostate.
PorterCable,4825Highway45North,Jackson,Tennessee38305•888-848-5175.
©2023,PorterCable/PorterCable.Allrightsreserved
UL733 Fifth Edition, CSA B140.8-1967

AVERTISSEMENT : Le non-respect des instructions, telles qu'indiquées dans le présent
guide, risque d'entraîner une explosion ou un incendie entraînant des dommages
matériels ou des blessures graves, voire mortelles.
– N'entreposezpasetn'utilisezpasd'essenceoud'autresliquidesouvapeursinflammables
àproximitédecetyped'appareil.
– L'entretiendoitêtreeffectuéparunfournisseurdeservicesd'entretienqualifié.
Cetappareildechauffageportatifn'estpasventilé.Ilutilisel'oxygènedel'airambiant.Une
circulationd'airadéquatedoitêtreassuréepourlacombustionetlaventilation.Voirpage3.
APPAREIL DE CHAUFFAGE
À AIR PULSÉ AU KÉROSÈNE
GUIDED'UTILISATIONETINSTRUCTIONSDEFONCTIONNEMENT
LISEZ SOIGNEUSEMENT LES INSTRUCTIONS.Lisezetobserveztouteslesinstructions.Conservez
lesinstructionspourvousyréférerultérieurement.Interdisezàquiconquen'ayantpaslulesprésentes
instructionsd'assembler,d'allumer,derégleroudefairefonctionnercetappareildechauffage.
Modèle#
NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!
PCXH80KT, PCXH140KT,
PCXH210KT
27354REVA
PorterCable,4825Highway45North,Jackson,Tennessee38305•888-848-5175

2
Porter Cable | Kerosene Forced Air Heater Operating Instructions and Owner’s Manual
NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!
TABLE DES MATIÈRES
AVERTISSEMENTS....................................................................... 2
FICHETECHNIQUE...................................................................... 3
PRÉCAUTIONSLIÉESAUFONCTIONNEMENT.............................. 3
PRÉCAUTIONSLIÉESÀLASÉCURITÉ........................................... 3
INSTRUCTIONSDEFONCTIONNEMENT....................................... 4
ENTRETIEN,ENTREPOSAGEETRÉPARATION................................ 4
DÉPANNAGE............................................................................... 6
SCHÉMADECÂBLAGE................................................................ 7
LISTEDESPIÈCES........................................................................ 8
VUEÉCLATÉE.............................................................................. 9
GARANTIE.................................................................................12
INSTRUCTIONSPOURLACOMMANDEDEPIÈCES.....................12
LANGUES
ANGLAIS………………………………………………………………………1-12
FRANCAIS………………………………………………………………1-12
ESPAGNOL……………………………………………………………………1-12
AVERTISSEMENT :
• N'EMPLOYEZPASD'ESSENCE,DENAPHTEOUDE
PRODUITSCOMBUSTIBLESVOLATILS.
• ARRÊTEZL'APPAREILDECHAUFFAGEAVANTD'Y
AJOUTERDUCOMBUSTIBLE.
• REMPLISSEZTOUJOURSLERÉSERVOIRÀL'EXTÉRIEUR,
LOIND'UNEFLAMMENUE.
• N'UTILISEZPASDESOURCEDECOMBUSTIBLEEXTERNE.
• NEFAITESPASFONCTIONNERL'APPAREILDECHAUFFAGE
SIDESVAPEURSOUDESLIQUIDESINFLAMMABLES
RISQUENTD'ÊTREPRÉSENTS.
• NEDÉMARREZPASL'APPAREILDECHAUFFAGESILA
CHAMBREDECOMBUSTIONESTCHAUDE.
• NEDÉMARREZPASL'APPAREILDECHAUFFAGESIUN
SURPLUSDECOMBUSTIBLES'ESTACCUMULÉDANSLA
CHAMBREDECOMBUSTION.
• NEPLACEZPASD'USTENSILESDECUISSONSUR
L'APPAREILDECHAUFFAGE.
• BRANCHEZLECORDONÉLECTRIQUEDANSUNEPRISEÀ
TROISBROCHESADÉQUATEMENTMISEÀLATERRE.
AVERTISSEMENT RELATIF AUX
MODÈLE PCXH80KT :
Non conçu pour être utilisé sur des planchers de bois
ou d'autres matériaux combustibles. Lors de son
fonctionnement, l'appareil de chauffage doit reposer sur
un matériau isolant adéquat d'au moins 2,5 cm (1 po)
d'épaisseur et dépassant l'appareil d'au moins 90 cm (3 pi)
de tous les côtés.
AVERTISSEMENT GÉNÉRAL DE DANGER :
LENON-RESPECTDESMESURESDEPRÉVENTIONET
INSTRUCTIONSFOURNIESAVECCETAPPAREILDE
CHAUFFAGERISQUEDECAUSERLAMORT,DESBLESSURES
GRAVESETDESDOMMAGESOUDESPERTESMATÉRIELLES
RÉSULTANTD'INCENDIE,D'EXPLOSION,DEBRÛLURE,
D'ASPHYXIE,D'INTOXICATIONAUMONOXYDEDECARBONE
OUD'ÉLECTROCUTION.
SEULESLESPERSONNESAPTESÀCOMPRENDREETÀ
RESPECTERLESINSTRUCTIONSDEVRAIENTUTILISEROU
EFFECTUERL'ENTRETIENDECETAPPAREILDECHAUFFAGE.
SIVOUSAVEZBESOIND'AIDEOUD'INFORMATIONAUSUJET
DEL'APPAREILDECHAUFFAGE(MANUELD'INSTRUCTIONS,
ÉTIQUETTES,ETC.),VEUILLEZCOMMUNIQUERAVECLE
FABRICANT.
AVERTISSEMENT :
DANGERD'INCENDIE,D'EXPLOSIONETD'INHALATION.
CONSERVEZLESMATÉRIAUXCOMBUSTIBLESTELSQUELES
MATÉRIAUXDECONSTRUCTION,LEPAPIERETLECARTONÀ
UNEDISTANCESÉCURITAIREDEL'APPAREILDECHAUFFAGE
COMMELERECOMMANDENTLESINSTRUCTIONS.
N'UTILISEZJAMAISL'APPAREILDECHAUFFAGEDANSUN
LOCALQUICONTIENTOURISQUEDECONTENIRDES
PARTICULESCOMBUSTIBLESENSUSPENSIONDANSL'AIROU
DESPRODUITSTELSQUEDEL'ESSENCE,DESSOLVANTS,DU
DILUANTÀPEINTURE,DESPARTICULESDEPOUSSIÈREOU
DESPRODUITSCHIMIQUESINCONNUS.
AVERTISSEMENT :
L'UTILISATIONDECETAPPAREILGÉNÈREDESSOUS-
PRODUITSDECOMBUSTIONCONTENANTDU
MONOXYDEDECARBONE,PRODUITCHIMIQUE
RECONNUPARL'ÉTATDELACALIFORNIECOMME
CAUSEDECANCERETD'ANOMALIESCONGÉNITALES
(OUAUTRESRISQUESPOURLAREPRODUCTION).
CETAPPAREILCONTIENTDESPRODUITS
CHIMIQUESRECONNUSPARL’ÉTATDECALIFORNIE
COMMEPOUVANTCAUSERLECANCERETDES
MALFORMATIONSCONGÉNITALESOUAUTRES
DOMMAGESAUSYSTÈMEREPRODUCTEUR.
AVERTISSEMENT :
NONCONÇUPOURÊTREUTILISÉDANSUNEHABITA-
TIONOUUNVÉHICULERÉCRÉATIF.
AVERTISSEMENT :
VOTRESÉCURITÉPERSONNELLEÉTANTIMPORTANTE
POURTOUS,VEUILLEZLIRELESINSTRUCTIONSAVANT
D'UTILISERCETAPPAREILDECHAUFFAGE.
AVERTISSEMENT :
LE MONOXYDE DE CARBONE PEUT VOUSTUER.
UTILISATIOND’UNCHAUFFEPORTABLEDANSUN
ESPACECLOSPEUTPRODUIREAUMONOXYDEDE
CARBONEMORTEL.

Porter Cable| Kerosene Forced Air Heater Operating Instructions and Owner’s Manual
3
NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!
SPÉCIFICATIONS
PRÉCAUTIONS LIÉES AU
FONCTIONNEMENT
Cetappareildechauffageàairpulséetàfeudirectfonctionneau
kérosène.Ilestdestinéprincipalementàchauffertemporairementdes
édificesenconstruction,enrénovationouenréparation.
Lefonctionnementàfeudirectdecetappareilsignifiequetousles
produitsdecombustionseretrouventdansl'airambiant.Mêmesila
combustiondel'appareildechauffageestpresquecomplète,ilproduit
quandmêmedepetitesquantitésdemonoxydedecarbone.Lemonoxyde
decarbone(appeléCO)esttoxique.IlestpossiblequeleCOs'accumule
danslelocalàchauffer.Uneventilationinadéquatepourraitainsicauser
lamort.Lessymptômesressentisencasdeventilationinadéquatesontles
suivants:
• maldetête
• étourdissement
• sensationdebrûlureaunezetauxyeux
• nausée
• maldegorgeoubouchesèche
Assurez-vousderespecterlesconseilsausujetdelaventilationmentionnés
danslasectionPrécautionsliéesàlasécurité.
Unappareilàairpulsésignifiequel'airestsoufflédansl'appareilde
chauffageparunesoufflerie.Laqualitédelacombustiondépenddudébit
d'air.Parconséquent,l'appareildechauffagenedoitpasêtremodifiéniêtre
utilisésidespiècessontmanquantes.Demême,lessystèmesdesécuriténe
doiventpasêtrecontournésnimodifiéspourfairefonctionnerl'appareil.
Lorsquel'appareildechauffagedoitfonctionnerenprésenced'autres
personnes,l'utilisateurestresponsabled'informercesdernièresdes
instructionsetprécautionsliéesàlasécuritéetdelesavertirdesdangers
inhérents.
PRÉCAUTIONS LIÉES À LA SÉCURITÉ
1. Recommandépourl’utilisationaveclecombustibledepétrole
No.1-K.L’usineévaluéepourl’utilisationaveclepétroleNo.2-K,No.
1oulegazoledeNo.2,No.1oulefueldeNo.2ouleJetdeJP8.
Uncombustibleetcescombustiblespeuventêtreutilisésaussi.
N’utilisezjamaisdel’essence,lepétroleégouttédescasde
fanatique,lenaphte,dudiluantpourpeintures,del’alcoolou
autrescombustiblesextrêmementinflammables.
2. Vérifiezattentivementsil'appareildechauffageasubides
dommages.NEFAITESPASfonctionnerunappareilendommagé.
3. NEMODIFIEZPASl'appareildechauffageetnelefaitespas
fonctionners'iln'estplusdanssonétatd'origine.
4. Convientpouruneutilisationenextérieurouàl’intérieurlorsque
laventilationestadéquate.Nejamaisutiliserdansdeszones
normalementhabitables.Nepasutiliserlorsqu’ilestexposéaux
intempéries.L'appareilnedoitpasêtreexposéauxintempéries.
5. Faitesfonctionnerl'appareildansdesendroitsbienaérésenlaissant
uneouvertured'aumoins0,19m²(2pi²)prèsduplancheretune
autred'aumoins0,19m²(2pi²)prèsduplafond,quidonnent
directementsurl'extérieur.Augmentezladimensiondecesouvertures
telqu'indiquépourchaqueappareildechauffageadditionnel.
6. Gardeztouslesmatériauxcombustibles,commelepapieretlebois,
àaumoins2,4m(8pi)delasortiedel'appareildechauffageetà
1,0m(3pi)dudessusetdescôtésdel'appareilainsiquedelaprise
d'air.Placezl'appareilà3m(10pi)destoilesetdesrevêtements
plastiques,etfixez-lesafind'empêchertoutbattement.
7. Attention:Enraisondestempératuresélevéesàlasurfaceetàla
sortie,lesadultesetlesenfantsdoiventrespecterlesdistancesde
sécuritépouréviterlesbrûluresetl'inflammationdesvêtements.
Netouchezpasàl'appareil.Gardezlesenfants,lesvêtementsetles
produitscombustiblesàbonnedistancedel'appareil.
8. Placezl'appareildechauffagedefaçonàcequ'ilnesoitpasexposé
directementàl'eau.
9. Nel'utilisezjamaisdansdesendroitsquiserventnormalementà
l'habitationnioùsontprésentsdesenfants.
10. Utilisezuniquementsurdessurfacesstablesetdeniveau.(Modèles
PCXH80KT–Voirl'avertissementausujetdesplanchersdebois.)
11. N'utilisezpasl'appareilavecdesconduitsd'air.N'obstruezpasl'entrée
etlasortied'air.
12. Utilisezuniquementavecl'alimentationélectriquespécifiée.Le
raccordementélectriqueetlamiseàlaterredoiventêtreconformes
auCodenationaldel'électricité–ANSI/NFPA70(É.-U.)–etauCode
canadiendel'électricité–CSAC22.1–partie1(Canada).
13. N'utilisezqu'avecuneficheouunerallongemiseàlaterremuniede
troisbroches.
14. Nedéplacezpasl'appareil,neluitouchezpasetn'essayezpasd'en
fairel'entretienlorsqu'ilestchaud.
15. Utilisez-leuniquementenconformitéaveclescodes,lesordonnances
etlesexigencesdelaprovince,del'Étatoudelamunicipalité
concernés.
Modèles PCXH80KT PCXH140KT PCXH210KT
Tauxdecombustion: 80000Btu/h(23.4kW) 140000Btu/h(41.2kW) 210000Btu/h(61.5kW)
Consommation de 0,59 gal/h (2,2 L/h) 1,0 gal/h (3,9 L/h) 1,6 gal/h (6,0 L/h)
combustible:
Consommation électrique : 115 V, 60 Hz, 4,0 A 115 V, 60 Hz, 5.5 A 115 V, 60 Hz, 5,5 A
Courant maximal : 10 A 10 A 10 A
Temp. minimale 110 V 110 V 110 V
de fonctionnement :
Pression : 4,2 psig (29 kPa) 6,8 psig (47 kPa) 8,4 psig (58 kPa)
Température de sortie 704
o
C (1 300
o
F) 704
o
C (1 300
o
F) 704
o
C (1 300
o
F)
maximale :
Capacité du réservoir : 22,7 l (6 gal.) 37,9 l (10 gal.) 56,8 l (15 gal.)
Allumage : Par étincelle, en continu Par étincelle, en continu Par étincelle, en continu
Générateur d'étincelle : Allumeur
16.5 kV, 0.2 A
Allumeur
16.5 kV, 0.2 A
Allumeur
16.5 kV, 0.2 A
Appareil de commande : Commande transistorisée Commande transistorisée Commande transistorisée
Certication:
PRUDENCE : CSA certifié pour l’utilisation avec seulement No. 1-K le combustible de pétrole.
L’usine évaluée: No.2-K, No. 1 ou le gazole de No. 2, No. 1 ou le fuel de No. 2 ou le Jet de JP8, Mélanges de biodiesel B2, B5, B10 et B20

4
Porter Cable | Kerosene Forced Air Heater Operating Instructions and Owner’s Manual
NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!
INSTRUCTIONS DE FONCTIONNEMENT
DÉBALLAGE
1. Retirezl'appareildechauffagedelaboîte.
2. Enleveztoutlematérieldeprotectioninstallésurl'appareilpourle
transport.
3. Vérifiezsoigneusementtoutdommagequ'auraitpusubirl'appareil
dechauffagependantl'expédition.Sivousconstatezquelque
dommage,avisezimmédiatementlefabricantau1800251-0001.
ASSEMBLAGE (Pourmodèlesde140000et210000BTU/huniquement)
Lesroues,l’essieu,etlespoignéessetrouventdanslaboîteaveclespièces
servantàl'assemblage.
1. Lespoignéessontpréassembléessurleréservoir.Lapoignéede
transportetlepieddesoutiens’enclenchentsimplementenplace.
2. Pourassemblerlesroues,installezd’abordl’undesgrosécrousde
blocageàl’extrémitédel’essieu.
3. Faitesglisserunerouesurl’essieuàcôtédel’écrou,puisune
entretoise.
4. Faitesglisserl’essieupartiellementassemblédanslecadredesupport
deroue.
5. Faitesglisserl’entretoisesurl’essieuàcôtédusupportderoue.
6. Faitesglisserlaroue,puislederniergrosécroudeblocagesur
l’essieu.Àl’aidededeuxclésàmolette,tenezlesdeuxécrouset
serrez.NEPASSERREREXCESSIVEMENT.
AVANT LE FONCTIONNEMENT
1. Vérifiezsoigneusementtoutdommagequ'auraitpusubir
l'appareildechauffagependantl'expédition.Sivousconstatezdes
dommages,avisezimmédiatementlefabricantau1800251-0001.
2. Respecteztoutesles«Précautions».
3. Remplissezleréservoirdekérosènepropre.Dansdesconditionsde
froidintense,ilestpossiblequedelacondensationseformedans
leréservoir.Ilestdoncrecommandéd'ajouterunecuillèreàtable
deliquideantigivrantpar4litres(1gallon)decombustible.Utilisez
aumoins8litres(2gallons)decombustiblelorsduremplissagedu
réservoir.Assurez-vousquel'appareildechauffageestdeniveauet
queleréservoirnedébordepas.Servez-vousd'unentonnoiroud'un
contenantmunid'unlongbecverseur.
IMPORTANT : Avant de remplir le réservoir la première fois ou après
des périodes d'entreposage prolongées, enlevez-en la condensation.
4. Placezl'appareildechauffageàunedistancesécuritairedes
matériauxcombustibles.LemodèlePCXH80KTnesontpasconçus
pourêtreutiliséssurdesplanchersdeboisnid'autresmatériaux
combustibles.Lorsdesonfonctionnement,l'appareildechauffage
doitreposersurunmatériauisolantadéquatd'aumoins2,5cm
(1po)d'épaisseuretdépassantl'appareild'aumoins90cm(3pi)ou
plusdetouslescôtés.
DÉMARRAGE DE L'APPAREIL
1. Réglezlethermostatauminimumetassurez-vousquel'interrupteur
està«OFF».Branchezlecordondel'appareildechauffagedans
uneprisemiseàlaterrede115V,60Hz,1Ø.Réglezlethermostat
àsapositionlaplusélevée.Démarrezl'appareildechauffageen
mettantl'interrupteurà«ON»(Marche)(Lalumières’allumeàla
position«ON»).Réglezlethermostatàlatempératuredésirée.
L'appareildechauffages'arrêteraetredémarreraaubesoin.
CONDITIONSPOURUTILISERUNERALLONGEÉLECTRIQUE:pour
unerallongejusqu'à30,5m(100pi),conducteursdecalibre16;
pourunerallongede30,5à61m(101-200pi),conducteursde
calibre14.
NOTES :
• Lorsquelatempératureestinférieureà-12°C(10°F),ledémarrage
serafacilitésil'onmetundoigtsurl'orificedeventilationdela
visderéglagedepressionjusqu'àcequel'appareildechauffage
démarre.
• Cetappareilestéquipéd'undisjoncteurintégréàl'interrupteur
marche-arrêt.Sil'appareilnedémarrepas,placezl'interrupteur
à«OFF»,attendez5minutesetplacez-leà«ON».
ARRÊT DE L'APPAREIL
1. Placezl'interrupteurà«OFF».Pourunarrêtprolongé,débranchez
l'appareildechauffagedesasourced'alimentation.
REDÉMARRAGE APRÈS UN ARRÊT D'URGENCE
1. Placezl'interrupteurà«OFF»,attendez5minutespuisdémarrez
l'appareil.
ENTRETIEN ET ENTREPOSAGE
AVERTISSEMENT.Pourévitertouteblessure,débranchezl'appareilde
chauffagedelaprisemuraleavantd'eneffectuerl'entretien.
Pouroptimiserlefonctionnementetéviterlesproblèmes,effectuez
régulièrementlesinspections,lenettoyageetl'entretiensuivants.
RÉGLAGE DE PRESSION DE LA POMPE
Enraisondesvariationsdeviscositédescombustiblesetdel’usurenormale
despièces,ilpeutdevenirnécessairederéglerlapressiondelapompe.
JAUGEDEPRESSION
Réglagepressionvis
(situéeàl’arrièredel’appareildechauffage)
POUR RÉGLER LA PRESSION :
1. Remplissezleréservoir.
2.Démarrezl’appareil.
3.Repérezlavisdurégulateurdepressiondecombustible.Cette
visestsituéeàl’arrière,souslecouvercleduboîtierdefiltre
àair(àenviron2poàpartirdelagaucheet1poàpartirdu
haut).
4.Retireretlecapuchonencaoutchoucsurlavisderéglagedela
pressionducarburant.
5.Àl’aided’untournevisplat,serrezlavispouraugmenterla
pressionoudesserrez-lapourréduirelapression.Lespressions
nominalessontindiquéesdansletableaudesspécificationsàla
page3duGuided’utilisationetinstructionsdefonctionnement.
•danslesenshoraire augmentelapressiondelapompe
•danslesensantihoraire diminuelapressiondelapompe

Porter Cable| Kerosene Forced Air Heater Operating Instructions and Owner’s Manual
5
NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!
Pouruneefficacitémaximale,lecôneavantdelachambrede
combustiondoitêtrerougecerisesansprésenterdetachesfoncées,
etlaflammenedoitpasseprolongerau-delàducône.
SYMPTÔMES DE RÉGLAGE DE PRESSION INCORRECT
Problème : L'appareilneproduitpasuneflammeforteethomogène.
L'appareilémetdelafuméeetéjecteducombustiblebrut.
Lecôneavantnedevientpasrougecerise.
Cause : Lapressionesttropfaible.
Serrezlavisderéglagepouraugmenterlapressiondela
pompe.
Problème : Laflammedépassel'extrémitédutubedesortie.
Cause : Lapressionesttropforte.
Desserrezlavispourréduirelapressiondelapompe.
PROGRAMME QUOTIDIEN
1. GÉNÉRAL.Faitesuneinspectionvisuellegénéraledel'appareilde
chauffagepourdécelerlespiècesendommagéesoudesserrées.
Inspectezlesboulonsetlesécrouspourvousassurerqueles
vibrationsetlesmanipulationsbrusquesnelesontpasdesserrés.
Lespiècesendommagéesdoiventêtreréparéesouremplacées
avantd'utiliserànouveaul'appareildechauffage.Vérifiezsil'appareil
fonctionnenormalement(consultezlasection«Réparation»pour
unedescriptiondufonctionnementnormal).
2. FILTRES.Lesfiltresàairetàcombustibledoiventêtrepropres
pourassurerl'équilibredumélangeair-combustible.Àdéfautde
quoi,l'odeuraugmenteraetl'appareildechauffagedémarrera
difficilement.Nefaitespasfonctionnerl'appareilsanslesfiltres.
Sinécessaire,nettoyezlesfiltrestelqu'ilestdécritauxsections
«Programme500heures»et«Programmeannuel».
PROGRAMME 500 HEURES
1. FILTRED'ADMISSIOND'AIR.Enlevezlefiltreetlavez-leàl'aided'un
détergentdoux.Séchez-leàfondetremettez-leenplace.Nehuilez
pasl'élémentfiltrant.Sivousutilisezl'appareildansunendroit
contenantbeaucoupdepoussièresetdesaletés,nettoyezlefiltre
aussisouventquerequis(aux50heuresenviron).
2. ENLÈVEMENTDELAPOUSSIÈRE.Nettoyezl'appareildechauffage
deuxfoisparsaison(plussouventdanslesendroitspoussiéreux).
Enlevezlapoussièreaccumuléesurletransformateur,lebrûleur,le
moteuretlespalesduventilateuràl'aided'unjetd'aircomprimé.
Essuyezlessurfacesavecunchiffonsecetpropre.Inspectezces
endroitspourvousassurerquetoutematièreétrangèreaété
enlevée,particulièrementautourdubrûleuretdelazonede
combustion.
3. CELLULEAUCADMIUM.Nettoyezlapartievitréedelacelluleau
cadmiumàl'aided'unchiffondouxetsec.
4. GICLEUR.L'accumulationdesaletédecombustibleetdecarbone
causéeparl'aubed'entréeobstrueraéventuellementlesconduitsdu
gicleuretentraîneraunediminutiondudébitd'airetdecombustible.
Lapressionaugmenteragraduellement,cequidéséquilibrerale
mélangeair-combustibleetproduiraunsurplusdefuméeetd'odeur.
Dansuntelcas,remplacezlegicleur.
5. RÉSERVOIRDECOMBUSTIBLE.Nettoyez-ledeuxfoisparsaison(au
coursdespériodesd'utilisationintensive,nettoyez-ledeuxfoispar
mois).Rincezetvidangezleréservoiràl'aidedemazoutpropre.
PROGRAMME ANNUEL
1. FILTREDESORTIED'AIR.Enlevezlefiltredesortied'airetfrappez-en
doucementlecôtésalesurunobjetdurpourenleverlessaletés.
N'utilisezpasd'aircompriménideliquidepournettoyerlefiltre.
Replacezlefiltrepropredanssonréceptacledanslapositionoùil
était.Silefiltreparaîtextrêmementsale,remplacez-leparunautre
dumêmetype.Enremettantlecouvercledufiltreenplace,assurez-
vousquelejointd'étanchéitéestsolidementenplaceetquelesvis
ducouverclesontassezserréespourempêcherdesfuitesd'air.
2. FILTREÀCOMBUSTIBLE.Enlevezlefiltredelacanalisationde
combustibleetdirigezdel'aircompriméàtraverslefiltredansle
senscontrairedudébitducombustible.Veuillezporterdeslunettes
protectricesenutilisantdel'aircomprimé.
3. CANALISATIONSD'AIRETDECOMBUSTIBLE.Sicescanalisations
sontenlevéesaucoursdunettoyage,assurez-vousdebienserrerles
raccordsavantdefairefonctionnerl'appareil.
ENTREPOSAGE
Entreposezl'appareildechauffagedansunendroitsecexemptdevapeurs
etdepoussières.
Àlafindechaquesaison,nettoyezl'appareildechauffagetelqu'indiqué
danslasectionENTRETIEN.Rincezetvidangezleréservoiràl'aidede
combustiblepropre.Lefabricantrecommandederemplircomplètementle
réservoirdecombustibleavantunentreposageprolongépourdiminuerles
risquesdecondensation.
Ilestrecommandédestockélekérosèneuniquementdansdesconteneurs
portantlamention«KÉROSÈNE».
ENTRETIEN
Unappareildechauffagequiaétémodifiéouquinefonctionnepas
correctementrisqued'êtreunecausededangers.
Lorsquel'appareildechauffagefonctionnenormalement:
* Laflammerestedansl'appareildechauffage.
* Laflammeestvraimentjaune.
* Iln'yapasdeforteodeurdésagréable,pasdesensationdebrûlure
auxyeux,nidemalaisephysiquegénéral.
* Iln'yapasdefuméenidesuieàl'intérieurouàl'extérieurde
l'appareildechauffage.
* Ilneseproduitpasd'arrêtsimprévusouinexpliquésdel'appareil.
Codes des Thermostats Numériques
Code La Description
CH Chaleur Continue
F2 Défaut du Thermostat
LO La température ambiante est inférieure à 16�F
HI La température ambiante est supérieure à 99�F

6
Porter Cable | Kerosene Forced Air Heater Operating Instructions and Owner’s Manual
NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!
DÉPANNAGE
SYMPTÔME DÉPANNAGE
Circuitouvertducontacteurdecommandemaximale 1) Assurez-vousquel'appareilestrefroidi,placezl'interrupteurà«OFF»,attendez5minutesetredémarrezl'appareil.
Présenced'étincellesetappeldeflamme,mais 1) Vérifiezlecâblageverslemoteur(selonleschémadecâblageduprésentguide).
lemoteurnefonctionnepasoutourneàtrèsbasrégime 2) Assurez-vousquelemanomètreestbienenplaceetqu'iln'estpasendommagé.
3) Réglezlapressionpourassurerlebonfonctionnementdel'appareildechauffageselonlesspécificationsduprésentguide.
4) Débranchezl'appareil,puistournezleventilateurdanslesenshorairepourvérifiersilemoteurtournelibrement.
5) Retirezleboîtierdufiltreàairdumoteuretvérifiezsilerotordelapompeprésentedesdommages.Lecaséchéant,remplacezlerotor.
6) Silecâblageestadéquat,quelerotorestenbonétatetquelemoteurnetournepaslibrement,remplacezlemoteurouleboîtierd'alimentation.
7) Sileproblèmepersiste,remplacezl'ensemblecommandedeflamme.
8) Vérifiezsiunarcélectriqueseproduitentrel'électrodeetlecylindredecombustion.
9) Vérifiezlacontinuitédelacelluleaucadmium.
Aucuneétincelle 1) Assurez-vousquelalongueuretlecalibredelarallongeélectriquesontconformesauxspécifications(voirpage4).
2) Vérifiezlecâblageversl'allumeur(selonleschémadecâblageduprésentguide).
3) Vérifiezl'écartentrelespointesd'électrode(2,3-3mm).
4) S'iln'yatoujourspasd'étincelle,remplacezl'allumeur.
5) Remplacezl'ensemblecommandedeflamme.
Fonctionnementanormaldumoteur– 1)
Régimemoteurtropbas(lemoteurdoittournerà3450tr/min)–Remplacezlemoteur.
Lemoteursurchauffeous’arrête 2) Débranchezl'appareil,puistournezleventilateurdanslesenshorairepourvérifiersilemoteurtournelibrement.
3) Retirezleboîtierdefiltreàairdumoteuretvérifiezsilerotordelapompeprésentedesdommages.Lecaséchéant,remplacezlerotor.
4) Silecâblageestadéquat,quelerotorestenbonétatetquelemoteurnetournepaslibrement,remplacezlemoteurouleboîtierd'alimentation.
5) Remplacezl'ensemblecommandedeflamme.
Laflammen'estpasdétectée 1) Vérifiezlecâblageverslacelluleaucadmium(selonleschémadecâblageduprésentguide).
2) Nettoyezl'élémentphotoélectriquedelacelluleaucadmium.
a) Dégagezlacelluleaucadmiumdesonsupport.
b) Dégagezl'élémentphotoélectriqueducaoutchoucnoirduboîtierdelacelluleenpoussantsurles2filsviolets.
c) Nettoyezl'élémentphotoélectriqueavecunchiffondouxetdel'alcoolàfriction.
d) Remettezl'élémentphotoélectriquedansleboîtierdelacelluleaucadmium,puisréinstallezlesupport.
e) Vérifiezlefonctionnementdel'appareildechauffage.
3) Sil'appareilnefonctionnetoujourspas,remplacezlacelluleaucadmium.
4) Remplacezl'ensemblecommandedeflamme.
Défaillancedelacommandedeflamme 1) Vérifiezlecâblagedel'appareildechauffage(selonleschémadecâblageduprésentguide).
2) Remplacezl'ensemblecommandedeflamme.

Porter Cable| Kerosene Forced Air Heater Operating Instructions and Owner’s Manual
7
NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!
SCHÉMA DE CÂBLAGE
Lalistedespiècesetleschémadecâblageprésententl'appareildechauagetel
qu'ilaétéconstruit.N'utilisezpasunappareildechauagequidièredecequiest
illustré.Lerendementdel'appareildechauagedépendduréglagedelapression
d'air.Sivousavezundouteausujetdelapressiond'air,faites-lavérier.
Sil'appareildechauagenefonctionnepascorrectement,ildoitêtreréparé
uniquementparuntechnicienqualié.
WHT
RED
BLUE
BROWN
RED

8
Porter Cable | Kerosene Forced Air Heater Operating Instructions and Owner’s Manual
NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!
LISTE DES PIÈCES
REF
#
ARTÍCULO
#DESCRIPCIÓN
127175 Réservoirdecarburant80K
227176 Passe-filsencaoutchoucpourfiltreàcar-
burant
327177 Jaugedecarburant
426959 Bouchonduréservoird'essence
6n/a SellesAvantetArrière
727178 Barilinférieur80K
827179 Passe-filsencaoutchouc
9n/a Ailerondedéflecteurd'air(voirn°50)
10 27180 SupportHLS
11 27181 115interrupteurdelimitesupérieure
12 F226865 CapteurdeflammecellulaireCAD
13 n/a Cellulephoto(voirn°12)
14 27182 Électroded'allumage
15 27183 Adaptateurdebuse
16 27184 Tubedecarburantencaoutchouc
17 27185 Tubed'airencaoutchouc
18 n/a Pincedeconduitedecarburant
19 27186 Buse80K
20 27187 Couvertureavant80K
21 27356 Couverturearrièresupérieur80K
22 27189 Grilled'entrée80K
23 n/a Déchargedetraction
24 n/a Cordond'alimentation
25 2719 0 Sellenoirecôtécontrôle80K
26 27191 Transformateurd'allumage
27 27192 Sellenoire80K
28 n/a Filtreàcarburant(voirn°70)
29 27163 OBEPoignée
30 n/a Moteur80KFAK(voirn°67)
31 27193 Supportmoteur80K
32 27194 Paledeventilateur80K
33 27195 Condensateurdedémarrage
34 n/a Boîtierdesortieenaluminium(voirn°67)
REF
#
ARTÍCULO
#DESCRIPCIÓN
35 n/a Anneaudepompe(voirn°67)
36 n/a SichuanRotor(voir#67ou68)
37 n/a Cléd'entraînementdepompeenplastique
(voirnuméros67ou68)
38 n/a Aubes(voir#67ou68)
39 27196 Boîtierenplastique
40 n/a Jointdecarterd'entrée(voirn°70)
41 n/a Filtreàpoussièreentissu(voirn°70)
42 n/a Petitmaillemétallique
43 27197 Petitfiltreenmousse
44 n/a Roulementàbillesenacier(voirn°69)
45 n/a Ressortderéglagedelapression(voirn°
69)
46 n/a Chevilleennylon(voirn°69)
47 n/a Visderéglagedelapompeennylon(voir
n°69)
48 n/a Filtreenmousse(voirn°70)
49 n/a Tubedecombustion80K(voirn°50)
50 27198 Chambredecombustion
51 2719 9 Circuitimprimé
52 2720 0 Interrupteurd'alimentationunipolaire
53 27201 Boutondethermostat
59 27202 Supportdecellulephoto
60 n/a CoudedeBarbenlaiton(voirn°67)
61 n/a Plaquedesondedecontrôledetempéra-
ture
62 27203 Supportdemontagedecircuitimprimé
63 n/a Clipdegardearrière
64 2720 4 PanneaudethermostatPantek
66 n/a Goujondefixationdeselle
67 27205 Assemblagedeblocd'alimentation
68 F226831 Kitderotor(rotor,aubes,insertennylon)
69 F266842 Kitd'ajustementdepompe
70 F221887 Kitd'entretiendufiltre
This manual suits for next models
2
Table of contents
Languages:
Other Porter-Cable Heater manuals
Popular Heater manuals by other brands

TERMA
TERMA Ecostrad VeeSmart user manual

Manrose
Manrose TERRAZZA 2000W manual

Elnur Gabarron
Elnur Gabarron ECOMBI PLUS Series User operating instructions

Toyostove
Toyostove FF-50 Instalation and operation instructions

Nectre Fireplaces
Nectre Fireplaces 2000 Service instructions

SAKUTUS
SAKUTUS ECORA+ AL 200 instruction manual