AquaStar 32CDFLFR SERIES User manual

info@aquastarpoolproducts.com www.aquastarpoolproducts.com
VGB SERIES
SUBMERGED, SUCTION,
SINGLE, UNBLOCKABLE OUTLET INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS FOR
32CDFLxxx, 32CDFLFRxxx, 32CDFLVxxx, 32CDAVxxx, 32CDAVFRxxx,
32CDAVVxxx, 32CDLTxxx, 32CDLTFRxxx, 32CDLTVxxx, 32CDAVACxxx, 32CDBTxxx
32CDBTFRxxx, 32PDxxx, 32CDPHxxx, 32CDPHFRxxx, 32CDPHVxxx, 32CDPHTSxxx
(xxx = COLOR SUFFIX)
MEETS OR EXCEEDS NSF 50 2008 & ANSI/APSP-16 2011
ANTI-ENTRAPMENT/ANTI-VORTEX
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
▲WARNING!
Improper installation or use of this product may present a risk of hair or body entrapment and drowning. Install this
equipment in accordance with the instructions provided. Use only with the components and mounting hardware
provided. Failure to follow these instructions and/or use with components not provided by AquaStar Pool Products
and intended to be used with this product may result in improper positioning or functioning of suction outlet and may
cause severe injury or death.
• Ifnotasingle,unblockableoutlet,intheeventofonesuction
outlet being completely blocked, the remaining suction
outlets serving the system shall have a ow rating capable
of the full ow of the pump(s) or the specic suction system.
If in doubt about the rating and/or head loss curve of your
system, consult a qualied pool or spa professional and/or your
respective equipment manufacturer(s). Also, double-check
with your local building/health authorities regarding single vs.
multiple drain installations, etc.
• Allsizesofconnectingpipeareacceptable,pendingvelocity
and GPM calculations. The larger the pipe, the better!
(But do not exceed maximum GPM ratings marked on the
top of the cover or per installation instructions.)
• Replacecoverandscrewswithinve years.
CHANNEL DRAIN INSTALLATION INSTRUCTIONS
Installers, pool operators and pool owners must read these warnings and all instructions before
using this product!
Serious bodily injury or death can result if this product is not installed and used correctly.
Improper installation or use of this product may present a risk of hair or body entrapment and
drowning. Install this equipment in accordance with the instructions provided. Use only with the
components and mounting hardware provided. Failure to follow these instructions and/or use with components not
provided by AquaStar Pool Products®and intended to be used with this product may result in improper positioning or
functioning of drain cover and may cause severe personal injury or death.
WARNINGS AND IMPORTANT SAFETY PRECAUTIONS
READ AND FOLLOW ALL INSTRUCTIONS

877.768.2717 fax 877.276.POOL Outside the U.S.: 1.805.620.5060 fax +1.949.336.1940
info@aquastarpoolproducts.com www.aquastarpoolproducts.com
IMPORTANT NOTICE
Attention installer: This manual contains important information about the installation, operation and safe use of
this product. This information should be given to the owner and/or operator of this equipment. You may also refer
to www.aquastarpoolproducts.com for all warnings and instructions related to 32" channel drains.
Before installing this product, read and follow all warning notices and instructions which are included.
Failure to follow safety warnings and instructions can result in severe injury, death or property damage.
Call 877.768.2717 or visit our website at www.aquastarpoolproducts.com for additional free copies of these instructions. It is absolutely
critical that the suction plumbing be installed in accordance with the latest national and local codes for swimming pools.
Pool and spa pumps produce high levels of suction, which can pose extreme danger if a person comes in close proximity to an open
pool or spa drain or if a drain cover is loose, cracked, broken or missing. Pool and spa pumps move large volumes of water, which can
poseextremedangerifaperson’shaircomesincloseproximitytoadrainthatisnotthepropersizeforthepumporpumps.Suction
entrapment dangers include:
Hair Entanglement–Whenthehairtanglesorknotsinthedraincover,trappingtheswimmerunderwater.Thishazardispresent
when the ow rating of the cover is too small for the pump or pumps.
Limb Entrapment–Whenalimbissuckedorinsertedintoanopeningresultinginamechanicalbindorswelling.Thishazardispresent
when a drain cover is missing, broken, loose, cracked or not properly secured.
Body Entrapment–Whenaportionofthebodyisheldagainstthedraincover,trappingtheswimmerunderwater.Thishazardispresent
when the drain cover is missing, broken or the cover ow rating is not high enough for the pump or pumps.
Evisceration/Disembowelment – When a person sits on an open pool (particularly a wading pool) or spa outlet, and suction is applied
directlytotheintestines,causingsevereintestinaldamage.Thishazardispresentwhenthedraincoverismissing,loose,crackedornot
properly secured.
Mechanical Entrapment – When jewelry, swimsuit, hair decorations, a nger, a toe or a knuckle is caught in an opening of an outlet or
draincover.Thishazardispresentwhenthedraincoverismissing,broken,loose,crackedornotproperlysecured.
Use these ttings only with a pumping system rated for the corresponding ow or less. Failure to do so can
result in hair or body entrapment, which can cause severe injury or death. If in doubt about the rating of your
system, consult a qualied pool or spa professional.
IMPORTANT NOTICE
Regularly inspect all drain covers for cracks, damage and advanced weathering. If a drain cover becomes loose, cracked, damaged,
broken or is missing, close the pool or spa immediately, post a notice and keep the pool or spa closed until an appropriate VGB 2008
certied drain cover is properly installed. Drain covers deteriorate over time due to exposure to sunlight and pool chemicals. The
drain cover must be replaced within ve years from installation (or earlier if the cover becomes damaged in any way).
An VGB 2008 approved anti-entrapment drain cover must be used for each drain. If a drain
cover becomes loose, broken or is missing, close the pool or spa immediately and shut o the pump until
an approved anti-entrapment drain cover is properly installed with the supplied stainless steel screws. Only the supplied 316 stainless-
steel screws should be used with the drain cover. Substitute screws such as masonry screws, sheet rock screws or other types of screws
should never be used. Screws put into the frame anywhere except in the original screw holes will not hold and
willallowthedraincovertocomeothemaindrain,causinganentrapmenthazard,includingpossiblelimbandbodyentrapment
or evisceration/disembowelment. If the screw holes of the frame are stripped or the brass inserts are missing, loose or damaged,
replace the frame. DO NOT DRILL NEW SCREW HOLES IN THE FRAME AS THIS WILL DAMAGE AND WEAKEN THE FRAME.
WARNINGS AND IMPORTANT SAFETY PRECAUTIONS
SUCTION ENTRAPMENT HAZARD

877.768.2717 fax 877.276.POOL Outside the U.S.: 1.805.620.5060 fax +1.949.336.1940
info@aquastarpoolproducts.com www.aquastarpoolproducts.com 3
Most states and local codes regulate the construction, installation and operation of public pools and spas, and
the construction of residential pools and spas. It is important to comply with these codes, many of which directly
regulate the installation and use of this product. Consult the local building and health codes for more information.
• Alltypesofsuctionttingsshallnotbelocatedonseatingareasoronthebackrestsforsuchseatingareas.
• Anapprovedanti-entrapmentsuctionoutletcovermustbeusedforeachdrain.
• Neverexceedthemaximumowratestatedonthedraincover.
• Regularlyinspectdraincoversforcracksandsignsofadvancedweathering.
• Closethepoolorspaifanysuctionoutletcomponentisloose,cracked,broken,missingornotsecurelyattached.Replaceloose,
cracked, damaged, broken or missing drain covers.
• InstallinaccordancewiththelatestAPSPstandardsandCPSCguidelines,followallapplicablenational,stateandlocalcodes.
If you have any questions about installation or maintenance of this drain cover, please contact your pool professional. Never attempt to alter or repair
the cover or frame on your own.
A pool/spa pump produces high levels of suction, which can pose extreme danger if a person comes in close
proximity to an open pool or spa drain or a loose or broken drain cover or grate.
HYDROSTATIC RELIEF VALVE
Forinstallationsutilizingahydrostaticreliefvalve,usingacollectortubewillmaintainaclearpathtothehydrostaticvalve.Atleastone
hydrostatic relief valve in a set of suction outlets will allow hydrostatic uplift pressure caused by ground water to be relieved into the pool or spa.
ENTRAPMENT AVOIDANCE NOTICE
The covers used on suction outlets should be approved and listed as conforming to the currently published edition of ANSI/APSP-16
2011 Standard. These covers should be inspected regularly and replaced if cracked, broken or older than the design lifetime indicated
on them by the manufacturer. The maximum possible ow rate of the pump should be less than or equal to the maximum approved
ow rate indicated on the suction outlet cover by the manufacturer. The use of unapproved covers or allowing use of the pool or spa
when covers are missing, cracked or broken can result in body or limb entrapment, hair entanglement, evisceration or death.
WARNINGS AND IMPORTANT SAFETY PRECAUTIONS
Pumpsimproperlysizedorinstalledorusedinapplicationsotherthanforwhichthepumpwasintendedcan
result in severe personal injury or death. These risks may include but are not limited to electric shock, re,
ooding, suction entrapment or severe injury or property damage caused by a structural failure of the pump or other system component.
The use of alcohol, drugs or medication can greatly increase the risk of fatal hyperthermia in hot tubs
and spas.
To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at
all times.
When setting up pool water turnovers or ow rates, the operator must consider local codes governing turnover
as well as disinfectant feed ratios.
DONOTincreasepumpsize;thiswillincreasetheowratethroughthesystemandexceedthemaximumow
rate stated on the drain cover.
ACTS, CODES AND STANDARDS
All AquaStar suction outlet ttings (drain covers) are federally regulated by the U.S. Consumer Product Safety Commission
(CPSC). This authority was given to the CPCS in 2007 as part of the Virginia Graeme Baker Pool and Spa Safety Act. Visit
www.cpsc.org for more information.
ANSI/APSP-16 2011 Certication
All AquaStar suction outlets are certied by IAPMO in accordance with ANSI/APSP-16 2011 Standard for submerged
suction ttings for use in swimming pools, wading pools, spas and hot tubs. To download a current copy of the IAPMO
certication, go to www.IAPMORT.org.
(continued on next page)

877.768.2717 fax 877.276.POOL Outside the U.S.: 1.805.620.5060 fax +1.949.336.19404
info@aquastarpoolproducts.com www.aquastarpoolproducts.com
NSF-50 2008
All AquaStar suction outlets are certied to comply with NSF 50 2008 circulation system components and related materials
for swimming pools, spas and hot tubs. To download a current copy of the IAPMO certication, go to www.IAPMORT.org
Virginia Graeme Baker Pool and Spa Safety Act
All AquaStar suction outlets comply with the Virginia Graeme Baker Pool and Spa Safety Act, Section 1404(b). This section
requires all suction outlet ttings (drain covers) to conform to ANSI/APSP-16 2011 current standard.
International Code Council
AquaStar is an approved component as required by the International Code Council (ICC) building codes, which include
the International Residential Code (IRC) and the International Building Code (IBC), collectively know as the iCodes.
The ICC updates the iCodes every three years. For more information, visit www.iccsafe.org.
International Residential Code (IRC)
Many states and local jurisdictions have adopted the IRC, including Appendix G. Section AG106 addresses suction
entrapment avoidance requirements that regulate residential swimming pools and spas. It is important to know if these
codes are in eect where the residential pool or spa is being built and which version is being required. Eective in the
2009 version of the IRC is the requirement to build in accordance with ANSI/APSP 7-2006 American National Standard
for suction entrapment avoidance in swimming pools, wading pools, spas, hot tubs and catch basins. The 2003 and 2006
versions do not include a reference to the ANSI/APSP 7standard. Visit www.iccsafe.org for more information.
International Building Code (IBC)
Many states and local jurisdictions have adopted the International Building Code which regulates commercial building
projects, including public swimming pools and spas. Section 3109.5 addresses suction entrapment avoidance
requirements that regulate public swimming pools and spas. It is important to know if these codes are in aect where
the public pool or spa is being built and which version is being required. Eective in the 2009 version of the IBC is
the requirement to build in accordance with ANSI/APSP 7-2006 American National Standard for suction entrapment
avoidance in swimming pools, wading pools, spas, hot tubs and catch basins. The 2003 and 2006 versions do not include
a reference to the ANSI/APSP 7 standard. Visit www.iccsafe.org for more information.
ANSI/APSP-7 Suction Entrapment Avoidance Standard
The Association of Pool and Spa Professionals publishes many swimming pool and spa related standards, including ANSI/
APSP 7-2006 American National Standard for suction entrapment avoidance in swimming pools, wading pools, spas, hot
tubs and catch basins. ANSI/APSP 7 is referenced by the iCodes and is required by some states and local jurisdictions.
Itrequiresallsuctionoutletttings(draincovers)tobetestedandListedbyanationallyrecognizedtestinglaboratoryas
conforming to most recent version of ANSI/APSP-16 2011. Visit www.apsp.org for more information.
The Virginia Graeme Baker Pool and Spa Safety Act raises certain new requirements on owners and operators of
swimming pools and spas.
Pools or spas constructed on or after December 19, 2008,shallutilize:
A. No submerged suction outlets, a gravity drainage system with ASME/ANSI cover(s), one or more unblockable
outlets, or
B. A multiple main drain system without isolation capability with suction outlet covers that meet ASME/ANSI
A112.19.8 suction ttings for use in swimming pools, wading pools, spas and hot tubs, and either:
i. A safety vacuum release system (SVRS) meeting ASME/ANSI A112.19.17 manufactured safety
vacuum release systems (SVRS) for residential and commercial swimming pool, spa, hot tub,
and wading pool suction systems and/or ASTM F2387 standard specication for manufactured
safety vacuum release systems (SVRS) for swimming pools, spas and hot tubs, or
ii. A properly designed and tested suction-limiting vent system, or
iii. An automatic pump shut-o system.
VIRGINIA GRAEME BAKER POOL AND SPA SAFETY ACT
ACTS, CODES AND STANDARDS (continued)
(continued on next page)

877.768.2717 fax 877.276.POOL Outside the U.S.: 1.805.620.5060 fax +1.949.336.1940
info@aquastarpoolproducts.com www.aquastarpoolproducts.com 5
Pools and spas construction prior to December 19, 2008, with a single submerged suction outlet shall use a suction outlet
cover that meets ANSI/APSP-16 2011 and either:
A. A multiple main drain system without isolation capability or a single (VGB 2008 compliant) unblockable, or
B. A safety vacuum release system (SVRS) meeting ASME/ANSI A112.19.17 and/or ASTM F2387, or
C. A properly designed and tested suction-limiting vent system, or
D. An automatic pump shut-o system, or
E. Disabled submerged outlets, or
F. Suction outlets shall be recongured into return inlets.
For more information about the Virginia Graeme Baker Pool and Spa Safety Act, contact the U.S. Consumer
Product Safety Commission at 301.504.7908 or visit www.cpsc.gov.
Note: Always turn o all power to the pool pump before installing the cover or working on any suction outlet.
VIRGINIA GRAEME BAKER POOL AND SPA SAFETY ACT (continued)
(continued on next page)
POOL PUMP SUCTION REQUIREMENTS
Pumpsuctionishazardousandcantrapanddrownordisembowelbathers.Donotuseorallowanyoneelsetouseapool,spaorhot
tub unless it has at least two suction outlets, or an approved single, unblockable suction outlet to each pump suction line. Do not use
or operate swimming pools, spas or hot tubs if a suction outlet cover is missing, broken or loose.
ENTRAPMENT PROTECTION
Thepumpsuctionsystemmustprovideprotectionagainstthehazardofsuctionentrapmentorhairentrapment/entanglement.
SUCTION OUTLET COVERS
All suction outlet covers must be maintained. They must be replaced if cracked, broken or missing. See page 5 for outlet cover
certication requirements. All suction outlets must have correctly installed, screw-fastened covers in place.
WATER VELOCITY AND FLOW RATES
The maximum water velocity through drain covers is limited by some local regulations, for example some state health departments
limit the velocity through public pool drain covers to 1½ feet per second. This velocity limit is lower than the ow rating provided by
the ANSI/APSP-16 2011 certication, therefore the local limit applies and must be followed. Never exceed the ow rating listed on
the cover even if the local code does not provide a velocity limit.
PIPING GENERAL
Fornewinstallations,thepipingbetweendrainsmustbesizedtolimitthevelocitytosixfeetpersecond.Thislimitappliestothe
branch piping and all ttings between multiple outlets and the tee leading back to the pump. If code requires a lower water velocity,
complywiththecode.Seethechartbelowforinformationonpipesizeowratingsatsixfeetpersecond.
HYDRAULIC SYSTEM SPECIFICATIONS
ACCEPTABLE PIPE SIZE FOR MAXIMUM RECOMMENDED SYSTEM FLOW
RATE PER APSP-7 (6 feet/second in the branch line)
PipeSize 1½" 2" 2½" 3"
Flow Rate in GPM 45 80 110 160

877.768.2717 fax 877.276.POOL Outside the U.S.: 1.805.620.5060 fax +1.949.336.19406
info@aquastarpoolproducts.com www.aquastarpoolproducts.com
MANUFACTURED SUMP INSTALLATION (ONE, TWO or THREE PORTS)
IMPORTANT
• Models:32CDFLxxx, 32 CDAVxxx, 32CDFLVxxx,
32FLACxxx, 32CDAVVxxx, 32CDAVACxxx,
32CDBTxxx, 32CDLTxxx, 32CDLTVxxx,
32CDPHxxx, 32CDPHVxxx, 32CDPHTSxxx
(AV=Anti-Vortex)
• Singleormultipledrainorpipeuse
• AtIAPMO(anationallyrecognized
testing lab), all AquaStar channel drains have
been tested to
three inches in sump depth –
eld-fabricated or manufactured
• AllAquaStarchanneldrainsare
VGB 2008 compliant
• Plumbing to one or two pumps plus skimmer
equalizerareapproved–DONOTexceed
maximum ow rate of outlet cover for total
system
• One-, two- or three-pipe connections are
approved at any port or conguration under
manufactured sump or eld-fabricated sump
• Any plumbing conguration is approved but do
not exceed maximum ow rate!
• NOTE: 32CDPHxxx, 32CDPHVxxx, 32CDPHTSxxx
Flow rate is 256 GPM (oor) / 196 GPM (wall)
when more than one port is used.
g. 1
MANUFACTURED
SUMP INSTALLATION
(ONE, TWO, OR THREE PORTS)
INTERIOR
POOL FINISH
SHOTCRETE / GUNITE
EARTH
GRAVEL
OPTIONAL SINGLE CONNECTION
OR HYDROSTATIC VALVE
2" OR 2-1/2" PIPE
1 PUMP WITH 3" OR 4" TEE
2 SEPARATE PUMP SYSTEM CONNECTIONS
AV STYLE OR FLAT GRATE
(32CDAV) (32CDFL)
SUMP
ALL MODELS LISTED BELOW = ANTIENTRAPMENT/ANTIVORTEX AND
FOR SINGLE OR MULTIPLE USE
MAX FLOW RATES (PER OUTLET) MOUNTING POSITIONS (xxx=COLOR SUFFIX)
Model 32CDFLxxx (and
32CDFLFRxxx,
32CDFLVxxx,
32CDFLACxxx)
32CDLTxxx (and
32CDLTFRxxx,
32CDLTVxxx)
32CDAVxxx (and
32CDAVFRxxx,
32CDAVVxxx,
32CDAVACxxx)
32PDxxx
(min. 2” pipe)
32CDBTxxx,
32CDBTFRxxx
32CDPHxxx (and
32CDPHFRxxx,
32CDPHVxxx,
32CDPHTSxxx)
(min. 2” pipe)
Floor 316 GPM @ 3.9 fps 196 GPM @ 1.3 fps 236 GPM @ 3.4 fps 196 GPM @ 2.3 fps 120 GPM @ 1.2 fps 268 GPM @ 3.1 fps
Wall 208 GPM @ 2.6 fps 192 GPM @ 1.2 fps 136 GPM @ 1.9 fps 88 GPM @ 1.0 fps N.A. 172 GPM @ 1.0 fps
HYDRAULIC SYSTEM SPECIFICATIONS (continued)
SPECIAL NOTE ON CHANNEL DRAINS TO BUILDER, INSTALLER, PLAN CHECKER AND/OR INSPECTOR!
INSTALLATION LAYOUTS
A. See g. 1-5 on pages 7-9 for installation layout with manufactured sump.
B. See g. 6-7 on pages 9-10 for installation layout without sump (eld-fabricated sump).
C. Requires phillips screwdriver. Hand tighten only. Do not use electrical or air drills.
D. SPECIAL NOTE : USE ONLY PVC TO ABS (transitional glue) for cementing to ABS sump.
Do not use fast set, clear or “hot” blue glues.
E. Measure from underside of high point of the cover to the top of pipe(s) to determine proper sump depth.
F. SPECIAL NOTE : When installing vinyl/berglass versions, add a exible adhesive to fasteners and holes for extra leak
and tamper proong.

877.768.2717 fax 877.276.POOL Outside the U.S.: 1.805.620.5060 fax +1.949.336.1940
info@aquastarpoolproducts.com www.aquastarpoolproducts.com 7
IMPORTANT
• Models:32CDFLxxx, 32 CDAVxxx,
32CDFLVxxx, 32FLACxxx,
32CDAVVxxx, 32CDAVACxxx,
32CDBTxxx, 32CDLTxxx, 32CDLTVxxx,
32CDPHxxx, 32CDPHVxxx,
32CDPHTSxxx (AV=Anti-Vortex)
• Singleormultipledrainorpipeuse
• AtIAPMO(anationallyrecognized
testing lab), all AquaStar channel
drains have been tested to
three inches in sump depth –
eld-fabricated or manufactured
• AllAquaStarchanneldrainsare
VGB 2008 compliant
• Plumbing to one or two pumps plus
skimmerequalizerareapproved–
DO NOT exceed maximum ow rate
of outlet cover for total system
• One-, two- or three-pipe connections
are approved at any port or
conguration under manufactured
sump or eld-fabricated sump
• Any plumbing conguration is
approved but do not exceed
maximum ow rate
MANUFACTURED SUMP INSTALLATION (SINGLE PORT / PUMP INSTALLATION)
For additional information on proper drain installation refer to The Association of Pool &
Spa Professionals ANSI/APSP-7 Standard and the U.S. Consumer Product Safety Commission
GuidelinesforEntrapmentHazard.
g. 2
MANUFACTURED
SUMP INSTALLATION
(SINGLE PORT / PUMP INSTALLATION)
POOL FINISH
INTERIOR
SHOTCRETE / GUNITE
EARTH
GRAVEL
OPTIONAL SINGLE CONNECTION OR HYDROSTATIC VALVE
SINGLE PIPE CONNECTION ON
ANY OF THREE PORTS.
1-1/2", 2", 2-1/2", 3" OR GREATER PIPE
AV STYLE OR FLAT GRATE
(32CDAV) (32CDFL)
FRAME / MUD-RING
PLUG PORTS NOT BEING USED
TO PUMP
MANUFACTURED SUMP INSTALLATION (THREE PORT TEE / SINGLE PUMP INSTALLATION)
IMPORTANT
• Models:32CDFLxxx, 32 CDAVxxx,
32CDFLVxxx, 32FLACxxx,
32CDAVVxxx, 32CDAVACxxx,
32CDBTxxx, 32CDLTxxx, 32CDLTVxxx,
32CDPHxxx, 32CDPHVxxx,
32CDPHTSxxx (AV=Anti-Vortex)
• AtIAPMO(anationallyrecognized
testing lab), all AquaStar channel
drains have been tested to
three inches in sump depth –
eld-fabricated or manufactured
• AllAquaStarchanneldrainsare
VGB 2008 compliant
• Plumbing to one or two pumps plus
skimmerequalizerareapproved–
DO NOT exceed maximum ow rate
of outlet cover for total system
• One-, two- or three-pipe connections
are approved at any port or
conguration under manufactured
sump or eld-fabricated sump
• Any plumbing conguration is
approved but do not exceed
maximum ow rate
g. 3
MANUFACTURED
SUMP INSTALLATION
(THREE PORT TEE / SINGLE PUMP INSTALLATION)
POOL FINISH
INTERIOR
SHOTCRETE / GUNITE
TEE THREE PORTS TOGETHER
1-1/2", 2", 2-1/2", 3" OR GREATER PIPE
AV STYLE OR FLAT GRATE
(32CDAV) (32CDFL)
FRAME / MUD-RING
TO PUMP
GRAVEL
EARTH

877.768.2717 fax 877.276.POOL Outside the U.S.: 1.805.620.5060 fax +1.949.336.19408
info@aquastarpoolproducts.com www.aquastarpoolproducts.com
MANUFACTURED SUMP INSTALLATION (DUAL PUMP WITH
HYDROSTATIC VALVE INSTALLATION)
g. 5
MANUFACTURED
SUMP INSTALLATION
(DUAL PUMP WITH HYDROSTATIC VALVE INSTALLATION)
INTERIOR
POOL FINISH
SHOTCRETE / GUNITE
EARTH GRAVEL
PUMP #2
1-1/2", 2", 2-1/2",
3" OR GREATER PIPE
AV STYLE OR FLAT GRATE
(32CDAV) (32CDFL)
FRAME / MUD-RING
PUMP #1
1-1/2", 2", 2-1/2",
3" OR GREATER PIPE
OPTIONAL HYDROSTATIC VALVE
IMPORTANT
• Models:32CDFLxxx, 32 CDAVxxx,
32CDFLVxxx, 32FLACxxx,
32CDAVVxxx, 32CDAVACxxx,
32CDBTxxx, 32CDLTxxx, 32CDLTVxxx,
32CDPHxxx, 32CDPHVxxx (AV=Anti-
Vortex)
• Singleormultipledrainorpipeuse
• AtIAPMO(anationallyrecognized
testing lab), all AquaStar channel
drains have been tested to
three inches in sump depth –
eld-fabricated or manufactured
• AllAquaStarchanneldrainsare
VGB 2008 compliant
• Plumbing to one or two pumps plus
skimmerequalizerareapproved–
DO NOT exceed maximum ow rate
of outlet cover for total system
• One-, two- or three-pipe connections
are approved at any port or
conguration under manufactured
sump or eld-fabricated sump
• Any plumbing conguration is
approved but do not exceed
maximum ow rate
IMPORTANT
• Models:32CDFLxxx, 32 CDAVxxx,
32CDFLVxxx, 32FLACxxx,
32CDAVVxxx, 32CDAVACxxx,
32CDBTxxx, 32CDLTxxx, 32CDLTVxxx,
32CDPHxxx, 32CDPHVxxx,
32CDPHTSxxx (AV=Anti-Vortex)
• Singleormultipledrainorpipeuse
• AtIAPMO(anationallyrecognized
testing lab), all AquaStar channel
drains have been tested to
three inches in sump depth –
eld-fabricated or manufactured
• AllAquaStarchanneldrainsare
VGB 2008 compliant
• Plumbing to one or two pumps plus
skimmerequalizerareapproved–
DO NOT exceed maximum ow rate
of outlet cover for total system
• One-, two- or three-pipe connections
are approved at any port or
conguration under manufactured
sump or eld-fabricated sump
• Any plumbing conguration is
approved but do not exceed
maximum ow rate
MANUFACTURED SUMP INSTALLATION (BOOSTER & CIRCULATING PUMP INSTALLATION)
For additional information on proper drain installation refer to The Association of Pool &
Spa Professionals ANSI/APSP-7 Standard and the U.S. Consumer Product Safety Commission
GuidelinesforEntrapmentHazard.
g. 4
MANUFACTURED
SUMP INSTALLATION
(BOOSTER & CIRCULATING PUMP INSTALLATION)
INTERIOR
POOL FINISH
SHOTCRETE / GUNITE
EARTH GRAVEL
BOOSTER PUMP
1-1/2", 2", 2-1/2",
3" OR GREATER PIPE
AV STYLE OR FLAT GRATE
(32CDAV) (32CDFL)
FRAME / MUD-RING
CIRCULATING PUMP
1-1/2", 2", 2-1/2",
3" OR GREATER PIPE
OPTIONAL HYDROSTATIC VALVE

877.768.2717 fax 877.276.POOL Outside the U.S.: 1.805.620.5060 fax +1.949.336.1940
info@aquastarpoolproducts.com www.aquastarpoolproducts.com 9
g. 6
“A”
2" OR 2-1/2" PIPE
FIELD FABRICATED
SUMP INSTALLATION
(ONE, TWO, OR THREE PORTS)
INTERIOR
POOL FINISH
SHOTCRETE / GUNITE
EARTH GRAVEL
OPTIONAL SINGLE CONNECTION
OR HYDROSTATIC VALVE
1 PUMP WITH 3" OR 4" TEE
2 SEPARATE PUMP SYSTEM CONNECTIONS
AV STYLE OR FLAT GRATE
(32CDAV) (32CDFL)
FRAME / MUD-RING
IMPORTANT
• Models:32CDFLFRxxx,32CDLTFRxxxor
32CDAVFRxxx. 32CDBTFRxxx, 32CDPHFRxxx
(AV=Anti-Vortex)
• Singleormultipledrainuse
• AtIAPMO(anationallyrecognized
testing lab), all AquaStar channel drains have
been tested to
three inches in sump depth –
eld-fabricated or manufactured
• AllAquaStarchanneldrainsare
VGB 2008 compliant
• Plumbing to one or two pumps plus skimmer
equalizerareapproved–DONOTexceed
maximum ow rate of outlet cover for total
system
• One-, two- or three-pipe connections are
approved at any port or conguration under
manufactured sump or eld-fabricated sump
• “A”shouldbeaminimumofthree (3)inches to
the bottom of cover, must extend the entire
length of the cover.
• Any plumbing conguration is approved but
do not exceed maximum ow rate
• NOTE: 32CDPHFRxxx Flow rate is 256 GPM
(oor) / 196 GPM (wall) when more than one
port is used.
FIELD FABRICATED SUMP INSTALLATION (ONE, TWO or THREE PORTS)
For additional information on proper drain installation refer to The Association of Pool &
Spa Professionals ANSI/APSP-7 Standard and the U.S. Consumer Product Safety Commission
GuidelinesforEntrapmentHazard.
g. 7
"A"
IMPORTANT
* AT IAPMO (A NATIONALLY RECOGNIZED TESTING LAB),
ALL AQUASTAR SUCTION OUTLET COVERS HAVE BEEN TESTED
WITH 3" DEEP SUMPS (UNLESS OTHERWISE INDICATED).
* "A" SHOULD BE A MIN. 3" TO BOTTOM OF COVER.
FIELD FABRICATED
SUMP INSTALLATION
(SINGLE PIPE CONSTRUCTION)
POOL FINISH
INTERIOR
SHOTCRETE / GUNITE
EARTH GRAVEL
AV STYLE OR FLAT GRATE
(32CDAV) (32CDFL)
FRAME / MUD-RING
SINGLE PIPE CONNECTION
CAN BE ANY SIZE AND ANY
LOCATION ALONG CHANNEL SLOT.
FIELD FABRICATED SUMP INSTALLATION (SINGLE PIPE CONSTRUCTION)
IMPORTANT
• Models:32CDFLFRxxx,32CDLTFRxxx,
or 32CDAVFRxxx. 32CDBTFRxxx,
32CDPHFRxxx (AV=Anti-Vortex)
• Singleormultipledrainuse
• AtIAPMO(anationallyrecognized
testing lab), all AquaStar Channel
Drains have been tested to 3 inches
in sump depth – eld-fabricated or
manufactured
• AllAquaStarchanneldrainsare
VGB 2008 compliant
• Plumbing to one or two pumps plus
skimmerequalizerareapproved–
DO NOT exceed maximum ow rate
of outlet cover for total system
• One-, two- or three-pipe connections
are approved at any port or
conguration under manufactured
sump or eld-fabricated sump
• “A”shouldbeaminimumofthree
inches to the bottom of cover
• Any plumbing conguration is
approved but do not exceed
maximum ow rate
For additional information on proper drain installation refer to The Association of Pool &
Spa Professionals ANSI/APSP-7 Standard and the U.S. Consumer Product Safety Commission
GuidelinesforEntrapmentHazard.

10
info@aquastarpoolproducts.com www.aquastarpoolproducts.com
877.768.2717 fax 877.276.POOL Outside the U.S.: +1.805.620.5060 fax +1.949.336.1940
IMPORTANT
• Model:32PDxxx
• Singleormultipledrainuse
• AtIAPMO(anationallyrecognized
testing lab), the Propeller™ Drain
sump and cover was tested with no
additional sump depth
• AllAquaStarchanneldrainsare
VGB 2008 compliant
• Plumbingtooneortwopumpsplus
skimmerequalizerareapproved–
DO NOT exceed maximum ow rate
of outlet cover for total system
• One-pipeconnectioncanbeany
sizeandcenteredalongchannel
slot in sump
• Anyplumbingcongurationis
approved but do not exceed
maximum ow rate
• IMPORTANT:Tobeconsidered
unblockable, the Propeller™ drain
sump must be permanently and
securely axed to become an
integral part of the pool oor using
epoxy around the entire edge and
all of the enclosed plastic anchors or
optional brass anchors.
32"PINHOLE ANTIENTRAPMENT SUCTION OUTLET COVER AND PROPELLER
MANUFACTURED SUMP 32PDxxx INSTALLATION
The sump must be permanently and securely axed to the pool oor using epoxy under the sump and
around the entire edge and all of the enclosed plastic anchors or optional brass anchors. Once this is
completed, the sump becomes a permanent part of the pool structure, creating an unblockable drain.
The drain cover is then axed to the sump using the designated screws.
g. 1
SINGLE PIPE CONNECTION CAN BE
ANY SIZE AND CENTERED ALONG
CHANNEL SLOT.
PLASTER
32" PROPELLER DRAIN INSTALLATION INSTRUCTIONS
GRAVEL
SHOTCRETE/GUNITE
USE 1/4" MASONRY DRILL BIT AND INCLUDED
PLASTIC ANCHORS OR 5/16" DRILL BIT AND
OPTIONAL BIK4 BRASS ANCHORS
TWO-PART EPOXY
UNBLOCKABLE SUMP
PINHOLE ANTI-ENTRAPMENT
SUCTION OUTLET COVER
EPOXY OR SILICONE
g. 2
PLASTER
32" PROPELLER DRAIN INSTALLATION INSTRUCTIONS
STEP 1
GRAVEL
SHOTCRETE/GUNITE
UNBLOCKABLE SUMP
USE SCREWHOLES OF UNBLOCKABLE SUMP
TO POSITION DRILL
CENTER UNBLOCKABLE SUMP CHANNEL SLOT OVER PIPE
g. 3
PLASTER
32" PROPELLER DRAIN INSTALLATION INSTRUCTIONS
STEP 2
GRAVEL
SHOTCRETE/GUNITE
INSTALL SCREW ANCHORS (PLASTIC OR BRASS)
APPLY TWO-PART EPOXY TO UNDERSIDE OF
UNBLOCKABLE SUMP

info@aquastarpoolproducts.com www.aquastarpoolproducts.com 11
IMPORTANT
• Model:32PDxxx
• Singleormultipledrainuse
• AtIAPMO(anationallyrecognized
testing lab), the Propeller™ Drain
sumpandcoverwastestedatzero
inch sump depth
• AllAquaStarchanneldrainsare
VGB 2008 compliant
• Plumbingtooneortwopumpsplus
skimmerequalizerareapproved–
DO NOT exceed maximum ow rate
of outlet cover for total system
• One-pipeconnectioncanbeany
sizeandcenteredalongchannel
slot in sump
• Anyplumbingcongurationis
approved but do not exceed
maximum ow rate
• IMPORTANT:Tobeconsidered
unblockable, the Propeller™ drain
sump must be permanently and
securely axed to become an
integral part of the pool oor using
epoxy around the entire edge and
all of the enclosed plastic anchors or
optional brass anchors.
32PDxxx INSTALLATION CONTINUED
The sump must be permanently and securely axed to the pool oor using epoxy under the sump and
around the entire edge and all of the enclosed plastic anchors or optional brass anchors. Once this is
completed, the sump becomes a permanent part of the pool structure, creating an unblockable drain.
The drain cover is then axed to the sump using the designated screws.
g. 4
PLASTER
32" PROPELLER DRAIN INSTALLATION INSTRUCTIONS
STEP 4
GRAVEL
SHOTCRETE/GUNITE
TWO-PART
EPOXY
UNBLOCKABLE SUMP
AFFIX THE UNBLOCKABLE SUMP TO THE POOL FLOOR
USING THE INCLUDED
#10 X 1" SCREWS
g. 5
PLASTER
32" PROPELLER DRAIN INSTALLATION INSTRUCTIONS
STEP 5
GRAVEL
SHOTCRETE/GUNITE
TWO-PART
EPOXY
UNBLOCKABLE SUMP
SEAL PERIMETER WITH
EPOXY OR SILICONE
g. 6
PLASTER
32" PROPELLER DRAIN INSTALLATION INSTRUCTIONS
STEP 6
GRAVEL
SHOTCRETE/GUNITE
TWO-PART
EPOXY
UNBLOCKABLE SUMP
AFFIX THE PINHOLE ANTI-ENTRAPMENT SUCTION
OUTLET COVER TO THE UNBLOCKABLE
SUMP USING
THE INCLUDED #10 X 3/4" SCREWS
EPOXY OR SILICONE

877.768.2717 fax 877.276.POOL Outside the U.S.: 1.805.620.5060 fax +1.949.336.194012
info@aquastarpoolproducts.com www.aquastarpoolproducts.com
1. 32" three-port manufactured sump bucket
2. 32" channel drain, cover, flat
3. 2" NPT plug, qty 2
4. 32" channel drain, plaster shield
5. #10 x 3/4" flat head phillips type-a screw,
316ss, qty 16
4-11/32
1010
2-1/2" spigot x 2" socket x 2" NPT
3 2 4
5
1
32-19/32
3-27/32
5/16
Notes: unless otherwise specified.
Plaster shield and screws to be removed
after installation.
1
2 4
3
32-13/16
4-1/16 3-5/16
1-1/4
3/8
1. 32" channel drain, flat,
no sump, frame
2. 32" channel drain, flat,
no sump, cover
3. 32" channel drain, flat,
no sump, support, “dog bones”
to be removed prior to suction
outlet cover installation
4. #10 flat head phillips screw, qty 8
32CDFLxxx
32CDFLFRxxx

877.768.2717 fax 877.276.POOL Outside the U.S.: 1.805.620.5060 fax +1.949.336.1940
info@aquastarpoolproducts.com www.aquastarpoolproducts.com 13
1. 32" three-port manufactured sump bucket
2. 32" anti-entrapment suction outlet cover
3. 32" channel drain, plaster shield
4. 2" NPT plug, qty 2
5. #10 x 3/4" flat head phillips type-a screw,
316ss, qty 16
32-19/32
3-27/32
1010
5/16
5/16
2-1/2" spigot x 2" socket x 2" NPT
1
3
2
5
4
4-11/32
Notes: unless otherwise specified.
Plaster shield and screws to be removed
after installation.
32CDAVxxx
32-13/16
4-1/16 3-5/16
1. 32" channel drain, anti-entrapment, no sump, frame
2. 32" channel drain, anti-entrapment, no sump, cover
3. 32" channel drain, anti-entrapment, no sump, support,
“dog bones” to be removed prior to suction outlet
cover installation
4. #10 flat head phillips screw
1
2 4
3
1-1/4
3/8
32CDAVFRxxx

877.768.2717 fax 877.276.POOL Outside the U.S.: 1.805.620.5060 fax +1.949.336.194014
info@aquastarpoolproducts.com www.aquastarpoolproducts.com
23/32
32-19/32
3-27/32
4-11/32
10
10
1/2
1. 32" three-port manufactured sump bucket
2. 32" leaf trap insert
3. 32" leaf trap cover
4. 2" NPT plug, qty 2
5. 32" channel drain, plaster shield
6. #10 x 3/4" pan head phillips hi-lo screw, 316 ss, qty 8
7. #10 x 3/4" flat head phillips type-a screw, 316 ss, qty 8
1
2
3
6
4
5
7
2-1/2" spigot x 2" socket x 2" NPT
32-13/16
4-1/16
1/2 23/32
1-31/32
1. 32" channel drain, no sump, frame
2. 32" leaf trap insert
3. 32" leaf trap cover
4. 32" channel drain, frame support “dog bones”, qty 4
5. #10 x 3/4" flat head phillips type-a screw, 316 ss, qty 8
6. #10 x 3/4" pan head phillips hi-lo screw, 316 ss, qty 8
2
3
6
1
4
5
32CDLTxxx
32CDLTFRxxx

877.768.2717 fax 877.276.POOL Outside the U.S.: 1.805.620.5060 fax +1.949.336.1940
info@aquastarpoolproducts.com www.aquastarpoolproducts.com 15
32-19/32
3-27/32
4-11/32
10
10
1/2 7/8
1
2
3
5
4
8
6
7
2-1/2" spigot x 2" socket x 2" NPT
1. 32" three-port manufactured sump bucket
2. 32" leaf trap insert
3. 32" leaf trap cover
4. 32" channel drain “buzz top” cover
5. 2" NPT plug, qty 2
6. 32" channel drain, plaster shield
7. #10 x 3/4" flat head phillips type-a screw, 316 ss, qty 8
8. #10 x 1-3/4 flat head phillips type-a screw, 316 ss, qty 8
32CDBTxxx
32-13/16
4-1/16
1/2 7/8
2-1/8
2
3
1
5
4
7
6
1. 32" channel drain,
no sump, frame
2. 32" leaf trap insert
3. 32" leaf trap cover
4. 32" channel drain
“buzz top” cover
5. 32" channel drain, frame
support “dog bones”
6. #10 x 3/4" flat head
phillips type-a screw,
316 ss, qty 8
7. #10 x 1-3/4 flat head
phillips type-a screw,
316 ss, qty 8
32CDBTFRxxx

877.768.2717 fax 877.276.POOL Outside the U.S.: 1.805.620.5060 fax +1.949.336.194016
info@aquastarpoolproducts.com www.aquastarpoolproducts.com
Notes: unless otherwise specified.
Item 8 to be removed after installation.
Reserve screws for installation of suction grate.
33-27/32
5-3/32
5-5/32
1/2
1/8 max
10 10
1-1/32
9/32
3-5/32
1
2
3 4
5
6
7
8
2-1/2" spigot x 2" socket x 2" NPT
1. 32" three-port manufactured sump bucket
2. 32" vinyl clamping frame
3. 32" vinyl clamping ring
4. 32" anti-entrapment suction outlet cover
5. 32" channel drain, plug
6. #10 x 1" flat head phillips screw, ss
7. #10 x 1-1/4" flat head phillips screw, ss
8. 32" channel drain, installation plate
32CDAVVxxx VINYL/FIBERGLASS
Notes: unless otherwise specified.
Item 9 to be removed after installation.
Preserve screws for installation of suction grate.
33-27/32
5-3/32
1/8 max
10 10
5-1/32
1/2
1-31/32 7/32
1
2
4
6
5
7
8
9
2-1/2" spigot x 2" socket x 2" NPT
1. 32" three-port manufactured sump bucket
2. 32" vinyl clamping frame
3. 32" vinyl clamping ring
4. 32" channel drain, cover, flat
5. 32" channel drain, plug
6. #10 x 1" flat head phillips screw, ss
7. #10 x 1-1/4" flat head phillips screw, ss
8. 32" channel drain, installation plate
32CDFLVxxx VINYL/FIBERGLASS

877.768.2717 fax 877.276.POOL Outside the U.S.: 1.805.620.5060 fax +1.949.336.1940
info@aquastarpoolproducts.com www.aquastarpoolproducts.com 17
32CDBTVxxx VINYL/FIBERGLASS
Notes: unless otherwise specified.
Item 9 to be removed after installation.
Reserve screws for installation of suction grate.
33-27/32
5-3/32
1/8 max
10 10
5-3/4
1-7/32
1
2
3
5
4
6
7
8
9
2-1/2" spigot x 2" socket x 2" NPT
1. 32" three-port manufactured sump bucket
2. 32" vinyl clamping frame
3. 32" vinyl clamping ring
4. 32" channel drain, plug
5. #10 x 1" flat head phillips screw, ss
6. 32" leaf trap insert
7. 32" leaf trap cover
8. #10 pan head phillips screw
9. 32" channel drain, installation plate
32CDLTVxxx VINYL/FIBERGLASS
33-27/32
5-3/32
1/8 max
10 10
5-29/32
1-3/8
Notes: unless otherwise specified.
Item 9 to be removed after installation.
Preserve screws for installation of suction grate.
1
2
3
5
4
6
7
8
9
10
2-1/2" spigot x 2" socket x 2" NPT
1. 32" three-port manufactured sump bucket
2. 32" vinyl clamping frame
3. 32" vinyl clamping ring
4. 32" channel drain, plug
5. #10 x 1" flat head phillips screw, ss
6. 32" leaf trap insert
7. 32" leaf trap cover
8. 32" channel drain, installation plate
9. 32" debris catcher channel drain cover
10. #10 x 1-3/4 flat head phillips screw, ss

877.768.2717 fax 877.276.POOL Outside the U.S.: 1.805.620.5060 fax +1.949.336.194018
info@aquastarpoolproducts.com www.aquastarpoolproducts.com
32 13/16
"
4 1/16
"
1 1/4
"
3/4
"
4
1
2
3
1. 32" channel drain, no sump, frame
2.
#10 x 3/4" flat head phillips type-a screw, 316 ss
3. 32" channel drain, frame support "dog bones"
4. 32" channel drain anti-entrapment suction outlet
"pinhole" cover
32CDPHFRxxx
3
2
1
5
4
98
76
35"
1-3/8
"
1/8
"
largest opening
6-1/4
"
10-3/4
"
1. 32" propellor sump
2.
32" channel drain anti-entrapment
suction outlet "pinhole" cover
3.
#10 x 3/4" flat head phillips type-a screw,
316 ss
4. #10 x 1" pan head phillips screw, 316 ss
5. 1/4" concrete anchor
6.
3/8" bushing
7. 1/4" bushing
8.
8-32 x 3/4" lg. pan head phillips, 316 ss
9. #10 x 1" lg. pan head phillips, 316 ss
10. 10-24 x 7/8" pan head phillips, 316 ss
11. #8 x 3/4" pan head phillips, 316 ss
12. #8 x 1" pan head phillips, 316 ss
32PDxxx

877.768.2717 fax 877.276.POOL Outside the U.S.: 1.805.620.5060 fax +1.949.336.1940
info@aquastarpoolproducts.com www.aquastarpoolproducts.com 19
32CDPHxxx
33 7/8
"
5 1/8
"
10" 10"
5 1/16
"
1/2
"
3/8
"
2 1/2" SP. X 2" SOC. X 2" NPT
1. 32" channel drain anti-entrapment suction outlet "pinhole" cover
2. 32" 3 port manufactured vinyl/fiberglass sump bucket
3.
32" channel drain vinyl clamping gasket
4.
2" npt plug
5.
#10 x 1-1/4" flat head phillips type-a screw, 316 ss
6.
32" channel drain vinyl clamping ring w/ gasket
7.
#10 x 1" flat head phillips type-a screw, 316 ss
32CDPHVxxx
32-9/16
"
3-13/16
"
10" 10"
4-3/8
"
4"
2-1/2" Spc. x 2" Soc x 2" NPT
2
5
3
1
4
1. 32" 3 port manufactured sump
2. #10 x 3/4" flat head phillips type-a screw, 316 ss
3. 32" channel drain, plaster shield
4. 2" NPT plug
5. 32" channel drain anti-entrapment
suction outlet "pinhole" cover

877.768.2717 fax 877.276.POOL Outside the U.S.: +1.805.620.5060 fax +1.949.336.1940
▲WARNING! SUCTION ENTRAPMENT HAZARD
Increasingpumpsizewillincreaseow. When in doubt, consult your pool and spa professional.
Never use a pool or spa that has a missing or broken suction outlet cover.
Using a pool or spa with a missing or broken suction outlet cover can result in hair or body entrapment which can cause
severe bodily injury or death. The vacuum in suction outlets and/or suction outlet covers that are damaged, broken,
cracked,missingorunsecuredcancausesevereinjuryand/ordeathduetothefollowingentrapmenthazards:
HAIR ENTRAPMENT – Hair can become entangled in suction outlet cover.
LIMB ENTRAPMENT – A limb inserted into an opening of a suction outlet sump or suction outlet cover that is damaged,
broken, cracked, missing or not securely attached can result in a mechanical bind or swelling of the limb.
BODY SUCTION ENTRAPMENT – A negative pressure applied to a large portion of the body or limbs can result in
an entrapment.
EVISCERATION/DISEMBOWELMENT ENTRAPMENT – A negative pressure applied directly to the intestines through an
unprotected suction outlet sump or suction outlet cover which is damaged, broken, cracked, missing or unsecured
can result in evisceration/disembowelment entrapment.
MECHANICAL ENTRAPMENT – There is a potential for jewelry, swimsuit, hair decorations, a nger, a toe or a knuckle
to be caught in an opening of a suction outlet cover resulting in mechanical entrapment.
▲WARNING! TO REDUCE THE RISK OF ENTRAPMENT HAZARDS
If not an approved single, unblockable outlet, a minimum of two functioning suction outlets per pump must be
installed. Suction outlets in the same plane (i.e. oor or wall) must be installed a minimum of three feet (1 meter) apart,
as measured from near point to near point. Dual suction ttings shall not be located on seating areas or on the backrest
for such seating areas. If any suction outlets are located closer they shall be located on two dierent planes (i.e. one on
the bottom and one on the vertical wall, or one each on two separate vertical walls). The maximum system ow rate
shall not exceed the ow rating of any listed (per ASME/ANSI A112.19.8-2007) suction outlet cover installed. Never use
pool or spa if any suction outlet component is damaged, broken, cracked, missing or not securely attached. Replace
damaged, broken, cracked, missing or not securely attached suction outlet components immediately. In addition to two
or more suction outlets per pump installed in accordance with latest APSP, IAF Standards and CPSC guidelines, follow
all national, state and local codes applicable. Use only transitional (typically green) glues when attaching PVC pipe to
ABS ttings. Use gray medium set glue when attaching PVC pipe to our PVC based skimmers and double-deep sump
buckets. In both cases, do not ever use blue glue or related hot glues, clear glues or any fast-setting cement.
WARNING! –Failuretoremovepressuretestplugsand/orplugsusedinwinterizationofthepool/spafromthesuction
outlets can result in increased potential for suction entrapment as described above.
WARNING! – Failure to keep suction outlet components clear of debris such as leaves, dirt, hair, paper and other material
can result in increased potential for suction entrapment as described above.
WARNING! –Suctionoutletcomponentshaveanitelife;thecover/grateshouldbeinspectedbeforeeachuseoffacility
and replaced at least every ve years or if found to be damaged, broken, cracked, missing, not securely attached or
missing screws. DO NOT use facility until corrected!
A Safe Drain is No Accident™
As the manufacturer, AquaStar Pool Products, Inc., hereby certies that its suction outlet and drain covers meet or exceed
the requirements of the Virginia Graeme Baker Pool & Spa Safety Act, VGB 2008 and ANSI/APSP-16 2011 standards and
safety regulations as set forth by the U.S. Consumer Products Safety Commission.
A copy of this certicate is available on the AquaStar Pool Products, Inc. website under news & information:
www.aquastarpoolproducts.com
© 2011 AquaStar Pool Productions, Inc.
101111 Printed in the U.S.