2
AR, S.A. would like to thank you for the trust placed in our equipment, and we would remind you that our technical and
after-sales service department is entirely at your disposal for any queries or pro lems you may encounter.
Desde AR, S.A. le agradece os la confianza depositada en nuestros aparatos y le recorda os que nuestros departa entos
técnico y post-venta están entera ente a su disposición para qualquier cuestión o proble a que pueda encontrar.
The RC-21 vacuum sensor is designed to monitor
pressure and is not a safety measure to prevent
accidents. The compati ility of the sensor is the
responsa ility of the designer of the system and
specifications.
Operating Environment
AR vacuum sensors have not een investigated for
explosion-proof construction in hazardous environments.
Do not use with flamma le gases, liquids, or in hazardous
environments.
Avoid installing the sensor in locations where excessive
voltage surges could damage or affect the performance of
the sensor.
Operations
Dedicate a power supply of 10.8 to 30VDC to the sensor
and set the ripple to Vp-p10% or less. Avoid excessive
voltage. Avoid voltage surges.
A small amount of internal voltage drop is possi le. Ensure
the power supply minus any internal voltage drop exceeds
the operating load.
Verify the operating media is compati le with the
specified sensor. Check the chemical make-up, operating
temperatures, and maximum pressure ranges of the
system efore installing.
Installation of air dryer system is recommended to remove
moisture.
1. PRECAUCI NES DE SEGURIDAD
SAFETY PRECAUTIO S
2. ESPECIFICACI NES
SPECIFICATIO S
Rango de presión
Unidades de medida
Medios aplicables
Puertos de conexión
Temperatura de trabajo
Temp. de almacenamiento
Humedad relativa
Conexionado eléctrico
Tensión de alimentación
Visualización
Circuito de salida
Salida de control
Modos de salida
Tiempo de respuesta
Repetibilidad
Error de temperatura
Protección
Resistencia de aislante
Resistencia vibraciones
Resistencia de impacto
Materiales
Peso
Actualización visualización
Pressure range
Units of mesure
Media
Connection ports
Operating temperature
Storage temperature
Humidity
Electrical Connection
Power supply
Display
Output circuit
Switch output
Output mode
Response time
Repeatability
Thermal error
Protection
Insulation resistence
Vibration resistences
Shock resistence
Materials
Weight
Display refresh
-1 ... 0 bar
bar, Hg, inHg, kPa
Aire y gases no lubricados, no corrosivos
G1/8" acho male, M5 he bra female
0 ... 50 ºC
-10 ... 60 ºC
35 ... 85%
4-pins, M8 conector connector
10,8 ... 30 V DC, Rizado Ripple (P-P) 10% ax.
LED 3 dígitos, 7 seg entos 3-digit, 7-segment LED
PNP, NPN (opcional optional), open colector transistor 30V DC, 125 A
2 señales de salida NO/NC seleccionables, PNP o NPN, indicador de Led
2 output signals, PNP or NPN, NO or NC, LED indicator
Histéresis, co parador de ventana Hysteresis or window comparator
<2 s
± 0,2% F.S.
± 1% FE a at 25ºC
IP65 (IP40 sin tubo flexible de desaireación without ventilation flexi le tu e)
> 100M oh s a at 500 V DC
10 a to 55Hz, 1.5 , XYZ, 2 hrs
10 G, XYZ
Cuerpo: policarbonato; Puerto de presión: fundición de zinc
Housing: polycar onate; Pressure Port: zinc die-cast
35g
0,1 ... 3,0 s
Air and non-corrosive gases
El sensor de vacío RC-21 esta diseñado para
onitorizar la presión y no es una edida de
prevención de accidentes. La co patibilidad del
sensor es responsabilidad del diseñador del siste a
y especificaciones.
Ambiente de Trabajo
Los sensores de vacío AR no fueron investigados en
tér inos constructivos a prueba de explosión en a bientes
peligrosos.
No utilizar con gases infla ables, líquido o en a bientes
peligrosos.
Evite instalar el sensor en lugares donde haya
sobretensiones que puedan dañar o afectar al funciona iento
del is o.
peraciones
Dedique una fuente de ali entación de 10,8 a 30 V CC
al sensor y ajuste el rizado a un 10% Vp o enos. Evite
sobretensiones o picos de tensión. Es posible que haya una
pequeña caída de tensión interna. Garantice la ali entación
de odo a que la pérdida interna de tensión no reduzca la
carga por debajo del íni o necesario de operación.
Verifique que los edios a e plear son co patibles con
el sensor. Verifique los ateriales quí icos, te peratura
de operación y el rango de presiones áxi o del siste a
antes de la instalación.
Es reco endable la instalación de un secador de aire para
eli inar la hu edad.