AREBOS AR-HE-LK800124F User manual

User’s Manual –AREBOS Air Compressor 24L
1
Air Compressor 24L
AR-HE-LK800124F
Please follow all security measures in this user´s manual to ensure a secure use.
Thank you for trusting in AREBOS.

User’s Manual –AREBOS Air Compressor 24L
2
List of contents
1. Safety instructions ...........................................................3
1.1 Icon description............................................................................................................................. 3
1.2 General safety instructions ........................................................................................................... 4
1.3 Safety instructions for working with compressed air and blow guns ........................................... 5
1.4 Safety instructions for paint spraying ........................................................................................... 6
1.5 Safety instructions for the compressor......................................................................................... 6
1.6 Operation of pressure vessels ....................................................................................................... 7
1.7 Check compressor and delivery..................................................................................................... 7
2. Technical data..................................................................8
3. Intended use....................................................................8
4. Exploded view .................................................................8
5. Operation ......................................................................10
5.1 Notes on Installation ................................................................................................................... 10
5.2 Layout.......................................................................................................................................... 11
5.3 Parts List (Fig. 1-5.2) .................................................................................................................... 14
6. Assembly and operation ................................................15
Fitting the supporting feet (18) ......................................................................................................... 15
Fitting the Wheels (19)...................................................................................................................... 15
Fitting the air filter (16) ..................................................................................................................... 15
ON/OFF switch (8) ............................................................................................................................. 15
Quick-release coupling (5)................................................................................................................. 15
Adjusting the pressure (Fig. 9)........................................................................................................... 15
Pressure switch adjustment .............................................................................................................. 15
Mains connection.............................................................................................................................. 15
Behavior in emergency situations ..................................................................................................... 15
After use ............................................................................................................................................ 16
7. Cleaning, maintenance and storage ............................16
7.1 General ........................................................................................................................................ 16
7.2 Drain condensation ..................................................................................................................... 16
7.3 Clean safety valve (17)................................................................................................................. 17
7.4 Change Intake Air filter (16) ........................................................................................................ 17
7.5 Transportation............................................................................................................................. 17
7.6 Storage ........................................................................................................................................ 17
8. Troubleshooting ............................................................18
9. Disposal instruction .......................................................18
9.1 Disposal of the packaging............................................................................................................ 18
9.2 Disposal of waste equipment...................................................................................................... 18
9.3 Meaning of the "dustbin"............................................................................................................ 18
EU Declaration of Conformity ............................................19

User’s Manual –AREBOS Air Compressor 24L
3
Please read and save these instructions. Read through this user’s manual carefully before using
product. Protect yourself and others by observing all safety information, warnings and cautions.
Failure to comply with instructions could result in personal injury and/or damage to product or
property. Please retain instructions for future reference.
1. Safety instructions
1.1 Icon description
Declaration of conformity: Products marked with this symbol comply with all
applicable Community legislation of the European Economic Area.
Read the manual.
Wear ear protection.
Warning of electrical voltage.
Warning of hot parts. The surfaces of the compressor may heat up during
operation.
Warning: compressor can start without warning.
Prohibition: Do not switch on the compressor before the compressed air hose is
connected.

User’s Manual –AREBOS Air Compressor 24L
4
1.2 General safety instructions
•Keep your work area in order.
- Clutter in the work area can result in accidents.
- Do not eat, drink or smoke in the work environment.
•Consider environmental influences.
- Do not expose the compressor to rain.
- Do not use the compressor in humid or wet environments.
- Ensure good lighting of the work area. Do not use the compressor where there is a risk of
fire or explosion, i. e. not near flammable liquids or gases.
•Protect yourself from electric shock.
- Avoid body contact with grounded parts (e.g. pipes, radiators, electric stoves, refrigerators).
•Warning of hot parts!
- While the device is in operation, the cooling fins of the cylinder head and the supply line
become very hot. It takes a while for the parts to cool down after using them. Do not touch
these.
•Keep other people away.
- Do not let other people, especially children, touch the compressor or the power cord. Keep
them away from your work area.
•Store your compressor safely.
- The unused compressor should be parked in a dry and locked room, out of the reach of
children.
•Do not overload your compressor.
- You work better and safer in the specified performance range.
•Wear suitable work clothes.
- Do not wear loose clothing or jewelry, they could be caught by moving parts.
- When working outdoors, sturdy shoes are recommended.
- Wear a hairnet for long hair.
•Use protective equipment.
- Wear safety glasses.
- Use a breathing mask when working on dust.
•Do not misuse the cable or the hose!
- Do not use the power cord to unplug the power cord from the wall outlet. Protect the cable
from heat, oil and sharp edges.
•Maintain your compressor with care.
- Keep your compressor clean to work well and safely.
- Follow the maintenance instructions.
- Regularly check the mains connection cable and the mains plug of the compressor and have
them replaced by a recognized specialist if damaged.
- Check extension cords regularly and replace them if they are damaged.
- Keep handles dry, clean and free of oil and grease.
•Unplug the power plug.
- When not using the compressor, before servicing and when changing tools.
•Avoid unintentional startup.
- Make sure that the ON/OFF switch is set to "0" when the power plug is plugged into the
socket.
The guaranteed sound power level is 79 dB.

User’s Manual –AREBOS Air Compressor 24L
5
•Use extension cords for outdoor use.
- Only use approved extension cords outdoors and marked accordingly.
•Always be attentive.
- Pay attention to what you do. Get to work with reason.
- Do not use the compressor when you are unfocused, tired or under the influence of drugs,
alcohol or medication.
•Check the compressor for any damage.
- Before further use of the compressor, protective devices or slightly damaged parts must be
carefully inspected for proper and intended function.
- Check that the moving parts are working properly and are not jammed or that parts are
damaged. All parts must be properly installed and meet conditions to ensure proper
operation of the compressor.
- Damaged safety devices and parts must be properly repaired or replaced by a recognized
specialist workshop, unless otherwise stated in the operating instructions.
- Damaged switches must be replaced by a qualified specialist.
- Do not use compressors where the ON/OFF switch cannot be turned on and off.
•DANGER! For your own safety, only use accessories specified in the operating instructions or
recommended or specified by the manufacturer. The use of other tools or accessories other
than those specified in the operating instructions may result in injury to you.
•Attention! Repairs only by a specialist.
- This compressor complies with the relevant safety regulations.
- Repairs may only be carried out by a qualified electrician using original spare parts;
otherwise accidents can occur to the user.
Attention! Discharge air pressure prohibited! The free discharge of compressed air can be
dangerous. This step may only be carried out by qualified personnel.
•Noise emission protection.
- Wear ear protection while using the compressor.
•Replacing the power cord.
- If the power cord is damaged, it must be replaced by a qualified professional to avoid
hazards.
•Installation site
- Only install the compressor on a flat surface.
1.3 Safety instructions for working with compressed air and blow guns
•Risk of injury! The compressed air jet that you can create with the compressor has a high
pressure. Incorrect handling of the compressor or the compressed air jet may result in injury.
- Do not point the air jet or compressed air tools connected to the compressor towards
persons or animals.
- Do not use the compressed air jet to clean clothing on the body.
- Do not insert hands or objects through the protectice grid of the compressor.
- Keep children and animals away from the working area of the compressor.
- When loosening the hose coupling, hold the coupling piece with your hand to avoid injury
from the recoiling air hose.
- Make sure that all hoses and pressure tools are suitable for the maximum allowable
working pressure of the compressor.
- At a working pressure of more than 7 bar, we recommend attaching the compressed air
hoses to a safety cable (e.g. wire rope).
- Wear safety goggles and breathing mask when working with the compressor for protection
against foreign bodies and blown parts.
- Check the compressor for rust and damage before each use. The compressor must not be
operated with a damaged or rusty pressure vessel/compressed air tank. If you discover

User’s Manual –AREBOS Air Compressor 24L
6
damage or rust, contact a qualified professional.
•Danger of burning! Compressors and lines reach high temperatures during operation.
Touching leads to burns.
- Do not touch the compressor and lines during operation to avoid burns.
- Be careful when working.
•The gases or vapors sucked in by the compressor must be kept free from any admixtures that
could cause fires or explosions in the compressor.
•Wear safety glasses and respiratory protection when working with the blow gun. Foreign
objects, blown-off parts, and swirled-up dust can easily cause personal injury and damage to
health through inhalation. Dust-raising work should be carried out outdoors.
•Warning: All hoses and fittings of road-going compressors must be suitable for use on
construction sites at the maximum permissible pressure.
•Avoid heavy loads on the piping system by using flexible hose connections to prevent kinking.
1.4 Safety instructions for paint spraying
•Do not use paints or solvents with a flash point of less than 55 ° C.
•Do not heat paints and solvents.
•If harmful liquids are processed, filter devices (face masks) are required for protection. Also
note the information provided by the manufacturers of such substances about protective
measures.
•The information and markings of the Hazardous Substances Ordinance applied to the outer
packaging of the processed materials must be observed. If necessary, additional protective
measures must be taken, in particular appropriate clothing and masks to wear.
•Do not smoke during the spraying process or in the working area. Also paint vapors are easily
combustible.
•Fireplaces, open light or sparking machines must not be present or operated.
•Do not store or consume food and drinks in the work area. Paint fumes are harmful.
•The working space must be greater than 30 m³ and sufficient air exchange must be ensured
during spraying and drying. Do not splash against the wind. Always observe the regulations
of the local police authority when spraying combustible or dangerous injection-molded parts.
•Do not use media such as white spirit, butyl alcohol and methylene chloride in connection
with the PVC pressure hose (reduced service life).
1.5 Safety instructions for the compressor
•DANGER! For your own safety, operate the compressor only after reading the safety
instructions.
•Risk of explosion! If you operate the compressor in an unsuitable, poorly ventilated place, in
an unsuitable ambient temperature, or in a room containing dusts, acids, vapors, or
flammable gases, there is a risk of explosion.
- The compressor must not be operated or stored in a room containing dusts, acids, vapors or
flammable gases. He can explode.
- Keep away easily flammable substances from the compressor.
- Keep the gases or vapors sucked in from the compressor free of any impurities that could
cause fires and explosions in the compressor.
- Operate the compressor only at an ambient temperature of at least 5°C and at a maximum
of 40°C. At temperatures below 5°C, the motor startup is endangered by stiffness.
- Ensure that the ambient temperature in a closed working environment is not higher than
25°C to ensure proper operation of the compressor while maintaining full air charge.
- Only operate the compressor in well-ventilated areas.
- Do not spray water or flammable liquids on the compressor.
•Risk of injury! The compressor's compressed air tank is under pressure during operation and

User’s Manual –AREBOS Air Compressor 24L
7
in the non-vented state. If the compressor is damaged, connections are loosened or
unsuitable or damaged lines are used, pressure may be released.
- The compressor must not be operated if the compressed air tank has defects that endanger
the operator or third parties.
- Check the compressed air tank for rust and damage before each use. If damage is found,
contact a qualified specialist immediately.
- Do not switch on the compressor before the compressed air hose is connected.
- Never drill holes in the compressed air tank, do not weld or deform it.
- Never operate the compressor if the compressed air tank is damaged or deformed.
- Ensure that the compressed air tank is always vented before releasing connections or
connecting or removing pneumatic tools.
- Make sure that you only use compressed air lines for compressed air that are suitable for a
maximum pressure that matches the device.
- Use a compressed air hose with hose protection when working with a pressure of 7 bar or
more.
- Do not try to repair damaged wires, but replace them.
- Never transport the compressor when the compressed air tank is pressurized.
•Risk of electric shock! Faulty electrical installation or excessive mains voltage can lead to
electric shocks.
- Only connect the compressor if the mains voltage of the socket agrees with the
specification on the type plate.
- Only connect the compressor to an easily accessible socket so that you can quickly
disconnect it from the power supply in the event of a malfunction.
- Lay the power cord so that it does not become a trip hazard.
- Do not kink the power cord and do not put it over sharp edges.
- Always disconnect the power plug from the wall outlet when not in use, before transporting
and before cleaning or maintenance.
- Do not use the compressor if the power cord or plug is damaged. Have the damaged part
replaced by an authorized dealer for an original part.
- The compressor has an overcurrent protection (11/70). Max. current 5 A.
•Risk of damage! Improper handling of the compressor can damage the compressor.
- Do not insert any objects into the compressor.
- Only transport the compressor by the transport handle provided for this purpose.
- Always keep the compressor upright.
- When the compressor starts up (starts), a brief voltage dip may occur, especially if the
power quality is poor. This can affect other devices (e.g. flickering a lamp).
1.6 Operation of pressure vessels
•Anyone who operates a pressure vessel shall maintain it in a proper condition, operate it
properly, monitor it, carry out any necessary maintenance and repair work immediately and
take the necessary safety measures according to the circumstances.
•The supervisory authority may order necessary monitoring measures in individual cases.
•A pressure vessel may not be operated if it has defects that endanger employees or third
parties.
•Check the pressure vessel for rust and damage before each use. The compressor must not be
operated with a damaged or rusty pressure vessel. If damage is found, please contact a
qualified specialist.
1.7 Check compressor and delivery
•Check the device and accessories for completeness and transport damage:
- Open the packaging and carefully remove the device from its packaging.

User’s Manual –AREBOS Air Compressor 24L
8
- Remove the packing material as well as packing and transport locks (if available).
- Check if the delivery is complete.
- Check the device and its accessories for transport damage.
- If possible, keep the packaging until the end of the warranty period.
•Swallowing and suffocation! Children are not allowed to play with plastic bags, foils and
small parts. Children can swallow small parts or put plastic bags and slides over their heads
and choke on them.
- Keep away children from the compressor, small parts and packaging material.
- The compressor is not a toy.
•Risk of injury! The compressor is very heavy. If you lift it out of the packaging by yourself,
you may injure yourself.
- Do not lift the compressor out of the package alone, but with the help of another person.
2. Technical data
Modell
AR-HE-LK800124F
Power
800 W
Tank volume
24L
Voltage
220-230 V a.c.
Frequency
50 Hz
Suction capacity
140 L/min
Operating pressure
Max. 8 bar
Compressor idle speed
1400 rpm
Sound power level*
79 dB(A)
Uncertainty K*
2.65 dB(A)
Sound pressure level*
68 dB(A)
Uncertainty K*
2.65 dB(A)
Protection type
IP20
Dimension
21.26 x 11.81 x 22.84 in (54 x 30 x 58 cm)
Weight
48.5 lbs (22 kg)
*(EN ISO 2151:2008)
3. Intended use
•The compressor is used to generate compressed air for compressed air tools.
•The machine may only be used according to its intended purpose. Any further use beyond
this is not intended. The user/operator and not the manufacturer is liable for any damage or
injury of any kind.
•Please note that our devices are not designed for commercial, craft or industrial use. We do
not assume any warranty if the device is used in commercial, craft or industrial companies as
well as in activities requiring equal treatment.
4. Exploded view

User’s Manual –AREBOS Air Compressor 24L
9
01 Covery
10 Obturating ring
19 Valve plate
28 Bolt
02 Left fan
11 Cylinder head
20 Washer
29 Bolt
03 Left crank case
12 Bolt
21 Right fan
30 Spring
04 Connecting rod
13 Obturating ring
22 Shaft seal
31 Rotator
05 Piston cup
14 Connecting pipe
23 Bearing 6908-2Z
32 Nut
06 Binder plate
15 Bolt
24 Bolt
33 Stator
07 Bolt
16 Valve block
25 Bolt
34 Bearing 6203-2Z
08 Cylinder
17 Valve
26 Right crank case
35 Adjusting washer
09 Obturating ring
18 Valve
27 Protection ring
36 Bracket
37 Vibration column
46 Connector
55 Handle
64 Nut
38 Spring
47 Safety valve
56 Shaft seal
65 Wheel

User’s Manual –AREBOS Air Compressor 24L
10
39 Air filter
48 Pressure switch
57 Choke plug
66 Bolt
40 Elbow
49 Capacitor
58 Nut
67 Plug
41 Deflation valve
50 Capacitor cover
59 Washer
68 Transportation
handle
42 Regulator
51 Check valve
60 Cushion foot
69 Air tank/pressure
vessel
43 Gauge
52 Unloading pipe
61 Washer
70 Overcurrent
protector
44 Gauge
53 Pipe
62 Bolt
45 Connector
54 Tank
63 Drain cock
5. Operation
5.1 Notes on Installation
•Warning! Before connecting, make sure that the data on the nameplate agrees with the
network data.
•Remove transport material and any transport securing devices.
•Check device and accessories for completeness and integrity.
•Check the device for transport damage. Immediately report any damage to the carrier with
which the compressor was delivered.
•Before commissioning, always assemble the device completely!
•Mount the compressor - if possible - with the help of another person.
•Before mounting, make sure you have enough space to install the compressor.
•Operate the device only on a firm level surface.
•The installation of the compressor should be close to the consumer.
•Long air lines and long supply lines (extension cables) should be avoided.
•Pay attention to dry and dust-free intake air.
•Do not install the compressor in humid or wet room.
•The compressor may only be operated in suitable rooms (well ventilated, ambient
temperature +5 to 40°C). There must be no dust, acids, vapors, explosive or flammable gases
in the room.
•Attention! The compressor is suitable for use in dry rooms. In humid environments, use is
not permitted.
•Supply hoses at pressures above 7 bar should be equipped with a safety cable (e.g. a
tightrope).

User’s Manual –AREBOS Air Compressor 24L
11
5.2 Layout

User’s Manual –AREBOS Air Compressor 24L
12

User’s Manual –AREBOS Air Compressor 24L
13

User’s Manual –AREBOS Air Compressor 24L
14
5.3 Parts List (Fig. 1-5.2)
1. Cylinder/Motor
2. Pressure vessel
3. Filter regulator
4. Pressure gauge for pre-pressure
5. Quick coupling
6. Tank pressure gauge
7. Pressure regulator
8. ON/OFF switch (red knob)
9. Transportation handle
10. Motor cover
11. Overcurrent protector
12. Non-return valve
13. Pipe
14. Condensate drain valve
15. Capacitor
16. Intake air filter
17. Safety valve
18. Supporting feet
19. Wheels
20. Nut
21. Washer
22. Screw
23. Handle

User’s Manual –AREBOS Air Compressor 24L
15
6. Assembly and operation
•IMPORTANT! You must fully assemble the device before using it for the first time.
•The following part numbers refer to the parts list of the chapter Layout!
Fitting the supporting feet (18)
•Fit the supplied rubber stopper as shown in Fig. 5.2.
Fitting the Wheels (19)
•Fitting the supplied wheels as shown in Fig. 6.1 & Fig. 6.2
Fitting the air filter (16)
•Remove all the transportation stops with a screwdriver (Fig. 7.1) and fasten the air filter (16)
securely to the appliance with the screws (Fig. 7.2).
ON/OFF switch (8)
•To switch on the compressor, pull out the red knob (8). To switch off the compressor, press
the red knob (8) in again. (Fig. 8)
Quick-release coupling (5)
•Connect
-Push the nipple on your compressed air hose into the quick-release coupling, the sleeve
will automatically spring forwards.
•Disconnect
-Pull back the sleeve and remove the hose
Important! As you release the hose coupling, hold the hose coupling part in your hand to
prevent injuries caused by the hose being thrown backwards.
Adjusting the pressure (Fig. 9)
•You can adjust the pre-pressure on the pressure gauge (4) using the pressure regulator (7).
The set pressure can be taken from the quick-lock coupling (5). To increase the pressure, turn
the regulator (7) clockwise; To reduce the pressure, turn the regulator (7) counter-clockwise.
The tank pressure can be read on the tank pressure gauge (6).
Pressure switch adjustment
•The pressure switch is set at the factory.
-Switch-on pressure 6 bar
-Switch-off pressure 8 bar
Mains connection
•Long leads, as well as extensions, cable drums, etc. cause voltage drops and can prevent
motor startup.
•At low temperatures below + 5 ° C, the motor startup is endangered by stiffness.
Behavior in emergency situations
1. Stop the work process
2. Turn off the device.
3. Disconnect the power plug

User’s Manual –AREBOS Air Compressor 24L
16
After use
1. Turn off the device.
2. Disconnect the power plug
3. Disassemble all accessories from the device, such as hose, tire filling knife, etc.
4. Allow the unit to cool before repairing or cleaning.
5. Check the device for possible damage.
7.Cleaning, maintenance and storage
7.1 General
•Disconnect the mains plug from the socket before any cleaning or maintenance work!
•Prior to all cleaning and maintenance work, the device must be depressurized.
To do this, use the tire inflation meter as a blow-out gun and operate the trigger until no
more air escapes.
•Risk of explosion! The compressed air tank (2) or the connected tools may be under
pressure; improper handling may cause a risk of explosion.
- Completely bleed the compressor before cleaning or servicing the compressor.
- Service the compressor regularly and have the necessary maintenance and repair work
carried out immediately by a recognized specialist workshop.
•Risk of burning! The compressor becomes hot during operation and you can burn yourself.
- Allow the compressor to cool down completely before cleaning or servicing the
compressor.
•Danger of short circuit! Water or other liquids that have entered the housing may cause a
short circuit.
- Disconnect the mains plug before any cleaning or maintenance work from the socket.
- Never immerse the compressor in water or other liquids.
- Do not use a high-pressure cleaner to clean the compressor.
- Make sure that no water or other liquids get into the housing.
- Disconnect compressed air hose and tools from the compressor before cleaning.
7.2 Drain condensation
•The condensation water must be drained daily by opening the drain valve (14) (at the bottom
of the pressure vessel) (Fig. 12).
•Risk of damage! When compressed air is in the compressed air tank (2), the condensed
water is expelled with high pressure when opening the drain valve (14).
- Reduce the vessel pressure before opening the condensate drain valve (14).
- Always carefully open the condensate drain valve and never fully open the drain valve (14).
•Environmental risk! If the condensation water enters the sewage system, it will lead to
environmental pollution.
- Dispose of condensed water only as special waste in accordance with local regulations.
•For permanent durability of the pressure vessel (2), drain the condensate water by opening
the drain valve (14) after each operation.
1. Turn the pressure regulator (7) to OFF and press the ON/OFF switch (8) down. Disconnect the
power plug from the power outlet.
2. Allow the compressor to cool completely.
3. Vent the compressor via the connected compressed air tool.
4. Disconnect connected pneumatic tools from the compressor.
5. Open the drain valve (14).
6. In addition, tilt the air tank (2) so that the drain valve (14) is the lowest point in the tank and
the condense water can drain off completely.

User’s Manual –AREBOS Air Compressor 24L
17
7. Close the drain valve (14) again.
7.3 Clean safety valve (17)
•The safety valve has been set to the highest permissible pressure of the pressure vessel.
•IMPORTANT! It is forbidden to adjust the safety valve or to remove its seal.
•From time to time, operate the safety valve to make sure it works as needed. Pull the ring
with sufficient force until you hear the compressed air being released. Then release the ring
again.
7.4 Change Intake Air filter (16)
•The Intake Air filter prevents the ingress of dust and dirt. The filter must be cleaned at least
every 300 hours of operation. A clogged intake filter significantly reduces the performance of
the compressor. Remove the filter from the compressor (Fig. 10-11) by loosening the
thumbscrew on the air filter. Then you can remove the filter from the two halves of the
plastic housing, remove the dirt by tapping and spray it with low-pressure air (about 3 bar)
before you re-insert it.
7.5 Transportation
•Risk of electric shock! If you transport the compressor during operation, there is a risk of
electric shock.
- Switch off the compressor before each transport and disconnect the mains plug from the
socket.
•Risk of damage! If you improperly transport the compressor or turn it upside down, it may
be damaged or liquids may leak.
- Only transport the compressor over short distances in an upright position.
- Secure the compressor against impact and vibration when transporting the compressor in a
vehicle.
- Always use the transport handle for transportation.
- Do not use hooks or ropes to lift the compressor.
1. Disconnect the power plug from the socket.
2. Allow the compressor to cool completely.
3. Vent the compressor.
4. Grasp the compressor for transport on the transportation handle (9).
5. Secure the compressor with ropes when transporting it in a vehicle or trailer.
6. Protect the device against unexpected shocks or vibrations.
7.6 Storage
•Risk of damage! Incorrect or improper storage may damage the compressor.
- Before storing, disconnect the mains plug from the socket to disconnect the compressor
from the mains.
- Store the compressor and all connected compressed air tools only in a de-aerated
condition.
- Always store the compressor in a dry environment.
- Always store the compressor standing upright and do not tilt it.
- Always store the compressor in a room inaccessible to children.
- Always store the compressor so that it cannot be put into operation by unauthorized
persons.

User’s Manual –AREBOS Air Compressor 24L
18
1. Disconnect the power plug from the socket.
2. Allow the compressor to cool completely.
3. Vent the compressor.
4. Clean the compressor and remove the condensation as described in this chapter.
5. Store the compressor on a flat and dry surface in a dark, dry and frost-free room, inaccessible
to children. The optimum storage temperature is between 5˚C and 30˚C.
6. Cover the compressor to keep it from dust and the like when not in use for a long time. Store
the device in its original packaging.
8. Troubleshooting
Problem
Possible solution
The device does not start.
- Check the air pressure and if necessary, release
air.
- Does it have electricity on the line.
The line is reduced.
- Change air filter.
- Does it have a leak.
9. Disposal instruction
9.1 Disposal of the packaging
•Please make reference to the guidelines and standards for appropriate disposal of the packaging
valid in your region. In part, the package may consist of plastic bags - watch this respect, with
special care to ensure that this is not out of the reach of children. There is a risk of suffocation!
9.2 Disposal of waste equipment
•Equipment must be disposed of in accordance with the rules and regulations of the local waste
disposal.
9.3 Meaning of the "dustbin"
Protect our environment; electrical appliances do not belong in household waste.
Use the provided for the disposal of electrical equipment collection points and
enter your electrical and electronic equipment that you no longer use. They help
ensure that the potential effects of incorrect disposal on the environment and
human health to be avoided. So, do your part to recycle, recycling and other
forms of recovery of waste electrical and electronic equipment. Information on
where the devices are disposed of, please contact your local authorities or local
Governments.
Our customer service number: +49 (0) 931-45232700
Canbolat Vertriebs GmbH • Gneisenaustraße 10-11 • 97074 Würzburg

User’s Manual –AREBOS Air Compressor 24L
19
EU Declaration of Conformity
We,
Canbolat Vertriebs GmbH, Gneisenaustraße 10-11, 97074 Würzburg, Germany,
Hereby declare that the product named below, seen its design and construction as well as according
to our sales, has been complied with the relevant and basic health and safety EU-requirements.
Name of the product: Air Compressor 24L
Model Nr.: AR-HE-LK800124F
Art. Nr.: 4260551580789
If the product has any modification not allowed by us, this declaration loses its validity.
Tested acc. to:
EU Standard:
2006/42/EC Machinery
EN 1012-1: 2010
EN 60204-1:2018
EMC directive(2014/30/EU)
EN 61000-6-1: 2007
EN 61000-6-3: 2007/A1:2011
Directive 2000/14/EC, Annex VI, & Directive 2005/88/EC
Date/Manufacturer Signature/Location: Würzburg, 18.06.2021
Identification of the signatory:
Korhan Canbolat, head of the company
Authorised representative for the technical documentation:
Korhan Canbolat
Office address:
Canbolat Vertriebs GmbH
Gneisenaustraße 10-11
D-97074 Würzburg
Return address can be found in the imprint: https://www.arebos.de/impressum/
VAT identification number: DE 263752326
Court of the Commercial Register is Würzburg, HRB 10082
WEEE Reg.-No. DE 61617071
Table of contents
Other AREBOS Air Compressor manuals
Popular Air Compressor manuals by other brands

Toolex
Toolex 598552 instruction manual

Biber
Biber OSKA9563 operating instructions

Conrad
Conrad 85 66 48 operating instructions

Bauer Kompressoren
Bauer Kompressoren Profi-Line CAPITANO 140-B operating manual

Atlas Copco
Atlas Copco XAS 185 CD7 T4F HOP instruction manual

Rotair
Rotair RVK 25 operating manual