Array electronic SH-300 User manual

SH-300
User’s Manual
Contents
Page 1 of 103
Contents
1SH-300 Hardware part..........................................................................................3
1. 1System General Introduction.......................................................................3
1. 2Specification Parameter...............................................................................3
1. 3 Hardware Structure ....................................................................................4
1. 4 Function Key List........................................................................................7
1. 5 Installation Dimensions and Guide.............................................................8
2SH300 Software Part.......................................................................................... 11
2. 1SH300 General Introduction...................................................................... 11
2. 2Process Chart............................................................................................ 11
2. 3Installation and Uninstallation of SH-300...................................................12
2.3.1 Installation of SH-300.......................................................................12
2.3.2 Uninstallation of SH-300..........................................................................................15
2. 4Operation Interface....................................................................................16
2.4.1 File.................................................................................................18
2.4.2 Edit................................................................................................18
2.4.3 View...............................................................................................19
2.4.4 Screen...........................................................................................20
2.4.5 Object............................................................................................21
2.4.6 Connect.........................................................................................22
2.4.7 Tool................................................................................................22
2.4.8 Help...............................................................................................23
2. 5Operation Instruction.................................................................................24
2.5.1 Indicator.........................................................................................24
2.5.2 Function Key..................................................................................25
2.5.3 Static text.......................................................................................26
2.5.4 Dynamic text..................................................................................27
2.5.5 Register.........................................................................................28
2.5.6 Bar Graph......................................................................................31
2.5.7 Trend Graph..................................................................................32
2.5.8 Bitmap...........................................................................................33
2.5.9 Message Display...........................................................................34
2.5.10 Alarm List .......................................................................................35
2.6 User-defined SH300 system information...................................................37
2.7 Multi Language Editor................................................................................47
2.8 Operation Example ....................................................................................49
3Manipulation.......................................................................................................56
3. 1 Download Window....................................................................................56
3. 2 Communication ........................................................................................56
3. 3 Shifting the windows.................................................................................57

SH-300
Text Panel
Page 2 of 103
3. 4 System Password.....................................................................................57
3. 5 Data setting ..............................................................................................58
3. 6 State Monitoring........................................................................................59
4 Connection with PLC..........................................................................................61
4. 1Mitsubishi FX Series..................................................................................61
4. 2 Siemens S7-200 Series............................................................................62
4. 3 OMRON C Series.....................................................................................63
4. 4 Delta DVP Series......................................................................................64
4. 5 Panasonic FP Series................................................................................65
4. 6 Vigor VH Series........................................................................................66
4. 7 Koyo S Series...........................................................................................67
4. 8 ADC DL05 Series.....................................................................................68
4. 9FATEK FBs Series...................................................................................70
4.10 Schneider NEZA/TWIDO Series...............................................................71
4.11 AB (AB-DF1Protocol) Series....................................................................72
4.12 THINGET XC Series.................................................................................73
4.13 Emerson EC20 Series..............................................................................74
4.14 KDN-K3 Series.......................................................................................75
4.15 HITACHI MICRO-EH Series.....................................................................76
4.16 MODBUS RTU/ASCII and RTU/ASCII EXTEND protocol.......................77
4.17 SH-300 Freedom Protocol.......................................................................................82
4.18 Array FAB Series PLC.............................................................................90
4.19 Array SR Series PLC...............................................................................93
4.20 Array TC-Pro Series Digital Timer/Counter/Tachometer..........................95
Appendix : Note item................................................................................................97

SH-300
User’s Manual Hardware Part
Page 3 of 103
SH-300 Hardware part 1
1.1 System General Introduction
SH-300 is a small Human-Machine interface, mainly being used to be connected with PLC or
other intelligent controllers with COM port communication function. It can monitor, setup and
modify the data of the register or the status of the relay inside the PLC; thereby manipulators can
monitor conveniently the PLC or the running status of the intelligent controllers with COM port
communication function.
[Function features]
▲The project development software SH300, built on WINDOWS platform, with friendly
operation interface, easy to learn, being able to edit several monitoring screens and
support multi-format graph.
▲The communication protocols will be downloaded into SH-300 Text Display together with
the project files. And it is unnecessary to edit the communication program in PLC
separately.
▲SH-300 can be connected with many PLC. it supports Mitsubishi, Omron, Siemens,
Panasonic ,Delta , Koyo ,Vigor ,ADC Schneider, AB PLC series and so on. it contains
Modbus and freedom communication protocol
▲With password protecting function
▲With alarm list function, real-time displaying the alarm information line by line.
▲Having 14 keys, which can be defined as function keys, being easily operated, replacing
some mechanical keys on the control cabinet, with the number key function.
▲Supporting several kinds’ communication ports: RS232/RS422/RS485
▲STN-LCD with back light display, displaying 24 characters X 4 rows
▲With multi-language displaying function, with user-defined system prompting information,
being convenient for different demands.
▲The front panel being up to IP65 Protection Level, waterproof, oil proof
1.2 Specification Parameter
—Hardware specification
Display screen
4.3’’STN LCD
Resolution
192 x 64 pixel
LCM life
With 25±2℃,65±10% RH over 50000 hours

SH-300
Text Panel
Page 4 of 103
Brightness
60 cd/m2
Color
Monochrome(yellow-green)
Contrast
Adjustable resistor
Background light
Long life yellow-green LED
Memory
110KB Flash ROM
Communication Port
PC RS232& PLC RS485/422 & PLC RS232
Function button
14 freely configurable keys
Allowable power disruption
≤20ms
Frame Dimension
171.8 x 84.2 x 38.6mm
Display Dimension
97.0 x 34.5mm
Installation hole
Dimension
165 x 85mm
Cooling Method
Natural air cooling
Weight
260g
—Electric specification
Rated voltage
12 ~24VDC±10% <300mA
Withstanding voltage test
500VAC 1minute(between signal and GND)
Insulation resistance
Over 10M ohm @ DC500V(between signal
and GND)
—Ambient Requirement
Operation ambient
temperature
–10℃~60℃
Operation ambient moisture
20~90%(no condensation)
Storage temperature
–20℃~70℃
Anti-jamming test
Voltage 1500Vp-p,pulse period 1us,continuing
1s
Vibration resistance
10~25Hz(2G for 30 min, in any of X,Y,Z axis)
Degree of protection
IP65(the front panel)
Caution!
Pay attention to the two polars of the power and the rated allowable voltage range,
otherwise the main machine will be damaged.
1.3 Hardware Structure
The front panel of SH-300 is as shown in the following figure. There is the 4.3’’STN LCD display at
the top left corner. At the top right corner and the bottom there are 20 thin-film switch keys, which
have a good handle and a long life. The Up Key, Down Key, ESC key, SET key, ALM key and ENT

SH-300
User’s Manual Hardware Part
Page 5 of 103
key are system keys. Except the basic function, the other fourteen keys can be set as special
function keys to realize the Screen-jumping and digital setup functions.
The front of panel of SH-300 programmable text display is shown as follows:
Basic function of keys: setting the input value of the PLC registers.
Special function of keys: Bit setting, Bit resetting and Screen jumping etc.
On the right side of SH-300 there are power terminal and COM port and on the left side there is a
contrast potentiometer. Refer to the following figure for details.
(Right side of SH-300)(Left side of SH-300)
When programming with SH300 software, please select the proper connection mode according
to the type of PLC. After completing the edition, connect the SH-300 and the relative serial COM
port of the PC via the programming cable SH-Cable. Then power on SH-300 and click the
download icon to download the project file into SH-300.
Left key
Up key
Right key
Down key
ESC-ESC key
SET-Set key
ENT-enter key
ALM-alarm key
4.3’’ STN LCD Display
0-9 digital key
+/- sign
CLR Deletion
DC24V
COM Port
Contrast
Potentiometer

SH-300
Text Panel
Page 6 of 103
When using if the contrast of the LCD isn’t fit, revolve the contrast potentiometer on the left side
with small sized screwdriver till the contract reach the desired degree
The display of SH-300 is with LED background light. Press any key, the background light will be
turned on automatically. The backlight will be turned off automatically if there is no operation in
the minutes .Users can modify the turnoff time of the background light in SH300 software and
then download into SH-300.And it will be OK.
The structure figure of SH-300 COM Port :
COM Port DC24V
9 PIN male plug power supply terminal
Pin Definition of SH-300 COM Port :
SH-Cable Wiring figure:
SH-300(9 PIN female plug)PC(9 PIN female plug)
RXD
2
TXD
3
RTS
7
GND
5
Pin
Definition
1
TD+
2
RXD
3
TXD
4
NC
5
GND
6
TD-
7
RTS
8
RD-
9
RD+

SH-300
User’s Manual Hardware Part
Page 7 of 103
2
RXD
3
TXD
7
RTS
5
GND


SH-300
User’s Manual Hardware Part
Page 9 of 103
1.4 Function Key List
key
Function
[←]
When modifying the register data, the cursor will be moved one-digit left.
[→]
When modifying the register data, the cursor will be moved one-digit right.
[↑]
To jump to the previous screen, whose number is set in the screen property option.
(The default value is the current number 1.)
In data-setting mode, pressing it, the modified number will be plus 1. The incremental
range is 0 to 9 (in decimal system) and 0 to F (in hexadecimal system).
[↓]
To jump to the next screen, whose number is set in the screen property option. (The
default value is the current number plus 1.)
In data-setting mode, pressing it, the modified number will be minus 1. The incremental
range is 9 to 0 (in decimal system) and F to 0 (in hexadecimal system).
[ +/- ]
In data-setting mode, sign of the modified number will be set.
[0-9 ]
In data-setting mode, the modified number will be set as the corresponding number.
[ESC]
Exit from the current operation such as register set, password input, alarm display and
so on.
[ALM]
Pressing this key, you can enter the system-defined alarm information screen.
[SET]
Pressing this key, you can modify the register data. The current modified register will
be color-reversely displayed and the current modified digital will be flashing. If there is
no register set component in current screen, the operation is the non-operation. If
press SET key again before pressing ENT, the current operation will be canceled and
you can continue to modify the next register data
[ENT]
In the situation that the password protected function is used, pressing this key, the
password set screen will be displayed.
In register-setting mode, pressing this key the modified data will be written into the
register and then it will continue to modify the next register data.
When the last register in this screen is modified, pressing this key, it will exit the
register modification state.
[CLR]
In data-setting mode, clear the set data.

SH-300
Text Panel
Page 10 of 103
1.5 Installation Dimensions and Guide
Dimensions of SH-300 (L*W*H): 171.8×98.8×38.6 (Unit: mm)
Dimensions of the installation hole: 165×85 (Unit: mm)
Method 1:Embedded installation
The installment surface must be up to Standard Type 4, being applicable for indoor or the
switchboard box on coequal condition.
Thickness of Clapboard: 0.5-0.9 mm.Dimensions of the installation holes are shown as follows:

SH-300
User’s Manual Hardware Part
Page 11 of 103
Method 2:DIN rail installation(standard 35mm DIN rail installation)
Method 3: Screw installation (To install on the motherboard)

SH-300
Text Panel
Page 12 of 103
《Memo》
—————————————————————————————
—————————————————————————————
—————————————————————————————
—————————————————————————————
—————————————————————————————
—————————————————————————————
—————————————————————————————
—————————————————————————————
—————————————————————————————
—————————————————————————————
—————————————————————————————
—————————————————————————————
—————————————————————————————
—————————————————————————————
—————————————————————————————

SH-300
User’s Manual Software Part
Page 13 of 103
SH300 Software Part 2
2.1 SH300 General Introduction
SH300 is the special development software of SH-300 Programmable Text Display, which is run
on the base of WINDOWS 98/2000/XP platform. SH300 software makes the best use of the
abundant graphic interface and the object-faced design of WINDOWS, which makes it convenient
for the users edit the required control screens and the alarm interfaces in a short time.
The essential of the project file is the Screen. Each screen is to perform some special functions
and different screens can be switched freely via design. The aggregate composed of all the
screens is the application project file.
After open the SH300 software, the user can create or open the screen. And in each screen static
text, dynamic text, indicator, register, function key, bit graph, bar graph, trend graph and so on
elements can be set. Different screens can be switched freely. Users can realize the data monitor,
parameter setup, switch control, alarm list monitor and so on functions by designing the contents
of the screen.2. 2 Process chart of using
2.2 Process Chart
The basic process chart of using is shown in the following figure:
Setup SH300
Create or Open a Project
Edit the Screen
Save the Project
Run SH300
Download the Project into Sh-300

SH-300
Text Panel
Page 14 of 103
2.3 Installation and Uninstallation of SH300
2.3.1 Installation of SH300
The installation of SH300 is very simple. In the installation process, a prompting dialogue box will
appear automatically and you will complete the installation smoothly on the computer under its
guidance. The main steps are as follows:
1. Insert the SH300 software CD into the CD Driver. Select the installation program file Setup.exe
and click it , the following diagram will be shown:
▲ Click NEXT to enter the next installation step. The License Agreement will be shown as in the
following diagram:
▲Click Cancel to exit the installation program.
2. If you agree the above license agreement, please click YES to enter the next step. The
interface requiring User Name, Company Name and Serial Number will be shown as follows:

SH-300
User’s Manual Software Part
Page 15 of 103
3. Fulfill the interface with the correct information and click NEXT to enter the installation path
setting interface as follows:
▲ Click NEXT, the SH300 software will be installed in the default path as shown. If it is necessary
to select the path, click BROWSE to reset the desired path.
▲Click Back, it will return to the previous interface.
▲Click Cancel, it will exit the installation program.
4. Select NEXT to enter the next installation window;
▲ If Typical option is selected, all application components of SH300 will be installed;
▲If Compact option is selected, the simplified components of SH300 will be installed;
▲If Custom option is selected, user will be allowed to select the components of SH300.

SH-300
Text Panel
Page 16 of 103
Note: Selection of Typical option is recommended.
5. Select NEXT to enter the program aggregate displaying window as in the following diagram:
▲ Click Next to start the installation program;
▲ Click Back to return to the previous interface;
▲ Click Cancel to terminate the installation program.
6. The installation program proceeds to the automatic installation procedure. Click Cancel, if you
want to terminate now.
7. When the automatic installation process is completed, the setup finish window appears. Click
Finish to complete the installation process.

SH-300
User’s Manual Software Part
Page 17 of 103
2.3.2 Uninstallation of SH300
There are two ways for the uninstallation of SH300:
1. Remove from WINDOWS START MENU
▲ Under the WINDOWS taskbar, click Start→Program→ARRAY→SH300→Unistall of SH300
As shown in the following diagram:
▲ When a confirm uninstall dialogue box appearing, click Yes and the following remove interface
will appear.
2. Remove from the Console:
▲ Under the WINDOWS interface, double click My Computer and the management files of My
Computer will be open.
▲ Double click and open the Control Panel. In the Control Panel, select Add/Remove Program
icon and the Add/Remove Program dialogue box appears.
▲ After selecting the SH300 program folder in the said dialogue box, click Modify/Delete button
and a dialogue box appears to ask if you want to remove the program. Click Yes and the
remove interface will appear as the above diagram.

SH-300
Text Panel
Page 18 of 103
2.4 Operation Interface
The window of SH300 software is mainly made up of menu bar, tool bar, distribution bar, edit
section, window description section, status bar and property section.
Tool bar
Create a new project file
Open a saved project file
Close the current project file
Save the current project file
Cut components
Copy components
Paste components
Delete components
Create a new screen
Delete the current screen
Copy the current screen
Set relative parameter of SH-300 Text Display
Login in alarm list information, each piece of alarm information correspond to a
status of a middle relay
Download the project into SH-300 via communication cable
Menu
Distribution bar
Status bar
Window Description
Edit section
Tool bar
Property section

SH-300
User’s Manual Software Part
Page 19 of 103
Indicator: displaying on/off status of PLC inner middle relay
Function key: 14 keys on SH-300 panel being able to be defined as function
keys, whose functions are screen-jumping and switch control etc.
Static text, including Chinese characters, English characters and characters
from other operation system
Dynamic text, text content being able to be changed by PLC’s register.
Register, placing the data-setting and data-setting components
(The operated object is the data register in PLC.)
Bar graph, which can be used to monitor data change in PLC
Trend graph, which can be used to monitor data change in PLC
Insert the monochrome graphics file (Max. 192×64 pixels )
Message display, which can display the status of PLC inner relay
user-definedly.
Distribution bar
Place on the above layer
Place on the next layer
Left align all selected objects
Right align all selected objects
Up align all selected objects
Down align all selected objects
Left frame align all selected objects
Right frame align all selected objects
Up frame align all selected objects
Down frame align all selected objects
Align in the middle horizon all selected objects
Align in the middle vertical all selected objects
Align in the horizontal equal interval all selected objects
Align in the vertical equal interval all selected objects

SH-300
Text Panel
Page 20 of 103
2.4.1 File
This instruction is mainly used for project file management, including creating, opening, saving etc
Menu Name
Function
New project
Create a new project file
Open project
Open an old project file
Save project
Save the current project file
Save as
Save the current file to a new path
Close project
Close the current project file
Exit
Exit SH300 software
2.4.2 Edit
This instruction is mainly used for tool management, including cut, copy, paste, delete, select all,
control, position and so on. The pulldown menu is shown as the following:
Table of contents