Arrowhead Alarm Products RM-8003B User manual

ESLWIRELESS KIT
EXPANSIONPACK
Toutilisethisinstructionsheet,someextrapartmayberequired,thatarenot
suppliedwiththekit.
Readthroughthepaperwork tosee what partsyouwillneed.
Theextrapartsare:
1to2x SWAN QUAD (PIR’s)…………………………………………………..….…..page1
1to2x VST-LS881AH (autorestingSmokeDetector)…………………… page 1
1to14 x DFW-915 (SupervisedWireless PIR’s)………………...….…………….page 2
1to14 x VST-FW-915 (SupervisedWireless SmokeDetector)……...…..…page 2
1to72 xRadioPendants: (make sure your remote match the Receiver Frequency)………page 3
RM-8006B (4button,915 Mhzwithslidingcover)
RM-8003B (4button,915 Mhz)
1x SS-SOLARBELL-AAP (WIRELESSSOLARPOWEREDSATELLITE)…...page 4
1x SS-1C (Wiredexternalsiren)………………………………………………………..page 4
Pleaseusethesepartnumbers whenorderingextrapartsforyourKit.
Theextra4K7and8K2Resistors insidethisenvelopeare
notneededforthesuppliedinstructions.
RM-8003B
RM-8006B
DFW-915
SS1-C REV1.14 OP

SmokeDetector SetupZones
Before continuing withthisprogramming,youwillneedtoEnable Zonesasshownabove.
Ifyouare connecting aSmoke detector,youwillneed totell the panelwhat zone the smoke detector iscon-
nected to. SoinProgrammode press <PROGRAM><123> and <ENTER> thenputinthe zone 1-16 that
the smoke ison(iffollowing the wiring diagram,that’s4) so <3-4> and <ENTER> now turnoption 5ON and
<ENTER>.
i.e. P123E4E(5ON)E (zone 4isnow a24Hour Fire zone)
EnablingZones
AsthisisaWireless Kityouwill need toDeactivate theWireless zone option,thenthe panelwilllooktothe
Hardwired Zones. Onlychange the Zonesthat youwishtouse asHardwired.
InInstaller Mode Press <PROGRAM> <122> <ENTER> thenselectthe zone youwishtochange <3-4>
and<ENTER> now turnoption 5OFF and <ENTER>.
i.e. P122E3E(5OFF)E(zone 3isnow aHardwired).
P122E4E(5OFF)E(zone 4isnow aHardwired).
Adding Hard Wired Zones: -SWANQUADor VST-LS881AH
Note.ThisexpansionpackcomeswithextraResistors(4K7and 8K2) theyare notneeded foranyofthe wire
diagramsshowninthispaperwork.The onlyresistorsyouwillneed are 2K2’s.
Page1/5
ChangingEntrydelay’s
Thisishowlong the panelgivesyoutogetinand disarmitafter asensor hasbeentripped.
Each sensor hasitsowndelayfrom0to9999 seconds. Ifyouhave topass asensor togettothe keypad thenit
should have adelay.InInstaller Mode press <PROGRAM> <144> <ENTER> thenselectthe zone youwish
tochange (1-8) and <ENTER> thenputinthe new time (0-9999)and <ENTER>.
i.e. P144E3E[][ ][ ][ ]E(zone 3defaultdelayis0seconds).
P144E4E[][ ][ ][ ]E(zone 4defaultdelayis0seconds).
Gnd 12V1C23C4Tmp Gnd
Outputs
Gnd 12V1234
RESISTORCOLOURCODES:
2K2= = RED,RED,RED,GOLD.
4K7= = YELLOW,VIOLET,RED,GOLD.
8K2= = GREY, RED,RED,GOLD.
EXTRAPIR1
BLUE
YELLOW
RED
BLACK
2k2
Zone 3passive
Infra-RedDetector
0v
12v
EOLTAMPEREOLRELAY
OnlyZones 3and 4should
beused as Hardwired
Zones,as thewireless PIR’s
arealreadyLoaded inon1
and 2already.
ChangingOutputPulse Time
Whenthe Smoke alarmistriggered the sirenswill make adifferentsound,thisisbecausetheyare being pulsed.
Thissound canbe changed at address 39.InInstaller Mode press <PROGRAM> <39> <ENTER> thenthe out-
putyouwishtochange <1-2> and <ENTER> now putinanew time in1/10thseconds(3to4sound better) and
<ENTER>.
i.e. P39 E2E4E (output2hasjusthad itspulse time changed to0.4second intervals).
TheSmokeDetectorcanbe replacewithaStandardPIRDetector,just
followthesame wiringas ‘EXTRAPIR1’butwiretozone4.
1
2
4
3
2k2
VST-LS881AH
Photoelectric
SmokeDetector

Page2/5
Adding Radio SmokeDetector: -VST-FW-915
ChangingOutputPulse Time
Whenthe Smoke alarmistriggered the sirenswill make adifferentsound,thisisbecausetheyare being pulsed.
Thissound canbe changed at address 39.InInstaller Mode press <PROGRAM> <39> <ENTER> thenthe out-
putyouwishtochange <1-2> and <ENTER> now putinanew time in1/10thseconds(3to4sound better) and
<ENTER>.
i.e. P39 E2E4E (output2hasjusthad itspulse time changed to0.4second intervals).
SmokeDetector SetupZones
Ifyouare connecting aSmoke detector,youwillneed totell the panelwhat zone the smoke detector isconnected
to. SoinProgrammode press <PROGRAM> <123> and <ENTER> thenputinthe zone 1-16 that thesmoke is
Loaded into <1-16> and <ENTER> now turnoption 5ON and <ENTER>.
i.e. P123E16E(5ON)E (zone 16 isnow a24 Hour Fire zone)
LoadingRadioSmoke Detectors
Before starting programming make sure the detector hasagood batteryinit.TheninInstaller mode press
<PROGRAM> <164> <ENTER> thenselectthe zone slotyouare loading (1-16)and <ENTER>.The keypad
willstartbeeping asit’slooking for asignal,now pressand hold testbuttononthe smoke for4seconds,itwill beep
backat you3timesand the keypad willtriple beep whenitgetsthe signal.
i.e.P164E16E KPstartsbeeping PRESSTESTBUTTON (for 4seconds) KP triple beeps
(aRadiodevice hasbeenloaded intozone 16).
ChangingEntrydelays
Thisishowlong the panelgivesyoutogetinand disarmitafter asensor hasbeentripped.
Each sensor hasitsowndelayfrom0to9999 seconds. Ifyouhave topass asensor togettothe keypad thenit
should have adelay.InInstaller Mode press <PROGRAM> <144> <ENTER> thenselectthe zone youwishto
change (1-16) and <ENTER> thenputinthe new time (0-9999)and <ENTER>.
i.e. P144E5E[][ ][ ][ ]E(zone 5defaultdelayis0seconds).
P144E6E[][ ][ ][ ]E(zone 6defaultdelayis0seconds).
LoadingRadioDetectors
Before starting programming make sure the detector hasagood batteryinitand that the cover ison.TheninIn-
staller mode press <PROGRAM> <164> <ENTER> thenselectthe zone slotyouare loading (1-16) and
<ENTER>.The keypad willstartbeeping asit’slooking for asignal,now openthe cover ofthe detector youwish
tolearn,the keypad will triple beep whenitgetsasignal.
i.e.P164E5E KP startsbeeping OPEN DETECTORCOVER KP triple beeps
(aRadiodevice hasbeenloaded intozone 5).
Adding Radio Zones: -DFW-915
Remember only1Detector canoccupy1Zone,thisalsoincludesHard wired Devices.
Ifanew device isloaded,inonanalreadyused zone,the old device willbe wiped and replace withthe new one.
The 2supplyPIR’sare loaded intozones1and 2.

Adding MoreRadio Pendants:–RM-8006B
Don’tuse slots21to28,astheyare alreadyinuse bythe 2supplied Pendants.
Page3/5
AddingRadiousers
The panelhasthe abilitytohave up to80 radiousers. Radiousersare loaded under address 18,slots21 to100.
RadioUsersshare user slotswithstandard pincode users, youcanhave amaximumof100 userscombined.
Slots21to28are alreadyassigned tothesupplied Pendants.
ToAdd RadioUsersyoumustbe inInstaller mode,thenpress <PROGRAM> followed byaddress <18>&
<ENTER> thenthe slotyouwishtochange i.e. <29> and then <ENTER> the keypad willstartbeeping,Now
press the Buttonyouwishtolearnin.Thekeypad will triple beep toindicate that itreceived thesignal.
Loading RadioUser 29: P18 E29 E(press thebuttonyouwishtolearn)user 29 isthe firstavailable slot.
Loading RadioUser 30: P18 E30 E(press thebuttonyouwishtolearn)
Loading RadioUser 31: P18 E31 E(press thebuttonyouwishtolearn)
User Permissions
AsDefaultall usescanArm,Disarmand DisarmStayMode.Notallradiouserswillwanttodothese actions, soyou
willneed todisablesomeofthem.User Permissionsare changed under address 4,thenthe user 21-100.
InInstaller mode press <PROGRAM> followed byaddress <4> and <ENTER> thenthe user youwishtochange
i.e. <29> and then <ENTER>,the Defaultoptionswill lightup.Nowturnoff the optionsyoudon’twantandpress
<ENTER> toaccept.
1=Arm,2=ArmStayMode,3=Disarm,4=DisarmStayMode.
i.e. P4E29E34E(user 29 cannow onlyArm)
i.e. P4E30E1E(user 30 cannow onlyDisarm)
i.e. P4E31E134E(user 31 cannow donothing)
User Mappingto Outputs step1
IfyouwishtoControlagarage door using aradiouser,(asshow indiagram) youwill need tomap aUser tooutput
4.OutputMapping ischanged under address 12,thenthe user 21-100.InInstaller mode press <PROGRAM> fol-
lowed byaddress <12> and <ENTER> thenthe useryouwishtoMap i.e. <31> and then <ENTER>,nowselect
the Outputthat istobe controlled <4> and <ENTER>.
i.e. P12 E31 E4E (user 31 isnow allowed touse output4)
User Commandto Outputs step2
Once usersand outputshave beenMapped youthenneed totelleach user what theycandotothat output,inthis
case it’sturniton,found under address 13.InInstaller mode press <PROGRAM> followed byaddress <13> and
<ENTER> thenauser youhave Mappedi.e. <31> and <ENTER>,now selectthe Outputthat istobe controlled
<4> and <ENTER>.
i.e. P13 E31 E4E (user 31 will nowturnOnOutput4)
Radio PendantsControlling Outputs:
Thisprogramming requiresthe extrarelaytobe connected tooutput4asshowninthe normalwiring guide.
Youwillalso need toload the Pendantsinasshownabove.
User Permissions step3
AsDefaultall usescanArm,Disarmand DisarmStayMode.Thisisnotwantedifthe user isgoing tocontrolaga-
rage door,so youneed toturnthemOff.User Permissionsare changed under address 4,thenthe user 21-100.
InInstaller mode press <PROGRAM> followed byaddress <4> and <ENTER> thenthe user youwishtochange
i.e. <31> and then <ENTER>,the Defaultoptionswill lightup.Nowturnoff the optionsyoudon’twantandpress
<ENTER> toaccept.
1=Arm,2=ArmStayMode,3=Disarm,4=DisarmStayMode.
i.e. P4E31E134E(user 31 cannotdoanyarming or disarming)

Adding aWired ExternalSiren: -SS-1C
Adding aWireless ExternalSiren: -SS-SOLARBELL-AAP
Youwillnotneed tolearnthe Transmitter intothe SS-Solarbell,astheycome pre-programmed outofthe box.
Gnd 12V1C23C4Tmp Gnd
Outputs
Gnd 12V1234
+12V
GND
STB
BELL
JUMPERSMUSTBEIN
THESEPOSITIONS
Gnd 12V1C23C4Tmp Gnd
Outputs
Gnd 12V1234
SS-1C
SATELLITESIREN
Page4/5
BLUE
BLACK
RED
SIREN
TAMPER
LED
STROBE
EOL
YELLOW

This manual suits for next models
2
Table of contents