Artistic Licence netLynx quad User manual

netLynx quad User Guide
Artistic Licence
Version 1-4
netLynx quad
User Guide

Page 2netLynx quad User Guide
Please read these instructions before using the product.
This product has been designed & manufactured for professional use only.
It should only be installed by a suitably qualied technician and in accordance with
electrical regulations in the country of use.
Unless directed in the instructions there are no user serviceable parts inside the
outer case of this product.
Always disconnect from the power supply when not in use.
Any specic IP rating, where appropriate, is given in the instructions. Unless
otherwise stated this product is designed for indoor use only. If used outdoors it
MUST be installed in an appropriate IP rated cabinet. Do not allow this product to be
exposed to rain or moisture. Do not allow liquid to penetrate the product.
Please recycle all packaging.
Copyright © Artistic Licence Engineering Ltd. All rights reserved.
Download the user guide by scanning the following QR code:

Page 3netLynx quad User Guide
Connections
Mounting Diagram
Ref. Type Description
1Data
Connection
DMX ports 1-4
2Data/PoE
Connection
RJ45
3LED Power / Identify
indicator
4LED Network indicator
5Power Input Pin 1 = 0 VDC
Pin 4 = 12-48 VDC
6LED DMX indicators
7Conguration Squawk (single
press) OR
Factory reset (hold
down and cycle
power)
Circuit Description
DMX512 Outputs Type: Floating
Pin 1: Connected to Internal Logic
Ground
Internal Logic Ground Isolated from PoE, DC power and Ethernet port.
The following table summarises the internal signal common interconnection and isolation.
Internal Earth and Isolation

Page 4netLynx quad User Guide
Product Overview
netLynx quad is a desktop or truss-mounted
bidirectional gateway. It converts 4 universes
of Art-Net (supports all versions up to Art-Net
4) or sACN ethernet into DMX512/RDM. The
product also supports DMX to Art-Net/sACN
conversion.
netLynx quad is congurable via its internal
web-browser or by using DMX-Workshop
(free-of-charge software available from Artistic
Licence). DHCP is supported for automatic IP
addressing.
netLynx quad oers high levels of electrical
protection. All outputs are protected against
mains electrocution (international voltages
including UK 3-phase) and are self-healing.
A handy factory reset switch enables the
default settings to be restored - simply hold
down and cycle the power. Alternatively, a
single press of this button sends a ‘squawk’
message over the network to the console. This
enables the gateway to be easily physically
located.
Summary of Key Features
y10/100BaseT
yArt-Net, sACN, RDNnet LLRP compatible
y4 bidirectional DMX512 ports, compatible
with all variants of DMX, including
DMX512-A.
yRDM (E1.20 - 2010) compatible
yPower, Ethernet and DMX port LEDs
yFactory reset and Squawk button
yPoE compatible (IEEE 802.3af - 2003)
yCongurable using internal web-browser
or DMX-Workshop
yDHCP supported, default IP 2.x.y.z
yAll outputs protected against continuous
connection to 425 VAC (self-healing)
yFailsafe mode
yRDM Integrity supported
ySurface or truss mount
Ethernet Connection
netLynx quad can be powered from either an
external PSU (12-48 VDC) or with PoE. The
latter requires a suitable ethernet switch for
the power source, such as Art-Switch PoE4.
Please note that the product should be
powered via EITHER the DC power input or
ethernet PoE, but not both (there is no option
to failover from one power source to the other
if both are connected).
Power
DMX Outputs
netLynx quad can output a maximum of four
Universes of DMX512 data. There are 4 DMX/
RDM output ports with XLR5 connectors.
The DMX512-A standard species that Cat5
cable can be used to carry DMX data. The
table below shows which cores should be
used. It is recommended that Cat5E cable is
used. RDM data uses the same connections
as the DMX512 data.
All outputs are electrocution protected against
continuous connection to 425 VAC.
Failsafe mode allows the user to dene what
the DMX outputs will do in the event that
network data or connectivity is lost. Failsafe
mode triggers after loss of either network data
for 7 seconds or loss of ethernet link.
The options are:
yDo nothing, i.e. hold last state (products
with serial nos. up to 163 work this way)
yOutput all channels at zero
yOutput all channels at full
yOutput a recorded failsafe scene
Failsafe mode is congured using our free
DMX-Workshop software. Failsafe mode also
operates at boot up, so if the gateways power
on and there is no controller, they will execute
failsafe.
Failsafe mode
netLynx quad has an RJ45 ethernet connector
and supports Art-Net 4 and sACN (ESTA
E1.31). netLynx quad requires Cat 5 cable or
better and supports 10BaseT and 100BaseT.

Page 5netLynx quad User Guide
XLR Pin
(convention)
Function Colour RJ45
Pin
Cable
Colour
1COM Black 7 &
8
White/
Brown
&
Brown
2 DMX - Blue 2Orange
3 DMX + Red 1White/
Orange
DMX512 Wiring
DMX Inputs
Any of the DMX ports can be set to receive
DMX and generate either Art-Net or sACN.
Conguration is achieved with either DMX-
Workshop or the web browser.
When receiving DMX, the LED port indicator
illuminates to show that data is being received.
Universe Addressing
The universe (Por t Address) is used to uniquely
identify the DMX data on the network.
Art-Net allows universe numbers in the range
0 - 32767.
sACN allows universe numbers in the range
1-65535.
For the avoidance of cross-protocol
confusion, users are advised to number
universes from 1.
Conguration
Conguration is achived via the internal web
server or via DMX-Workshop.
In order to restore the product to its factory
default state, hold down the reset button
(under the terminal guard) and cycle the
power.
Web-Server
IP Settings
The IP settings for the product are displayed
in the top section of the screen. The Edit
control allows the static IP, subnet mask and
gateway to be congured. DHCP operation
can be selected via DMX-Workshop.
The indicator meanings are as follows:
yOnline: Green = live connection between
browser & product; Red = connection lost
yPower: Green = powered; Flashing
green = Identify; Red = Fault
yNet: Yellow = Link; Green = Art-Net or
sACN activity
Port Settings
The settings for each DMX port can be
congured via the web-browser using the
following columns:
yPort: The DMX port number
yInput: Tick to set as DMX input
yDMX: Green shows changing data
yRDM: Tick to enable RDM
yDelta: Tick to enable delta transmission
(DMX frames are only sent when
network data changes)
yUniverse: Set the universe (port address)
for this output
yRate: Sets the DMX refresh rate:
- High = 24 ms frame time
- Medium = 32 ms frame time
- Slow = 48 ms frame time
yProtocol: Select either Art-Net or sACN
control over this output
To congure netLynx quad via the internal
web-server, either type in the IP address of
the product or, if your web-browser supports
NetBios, then enter the name: netLynxquad.
To nd the IP address, use DMX-Workshop.
The home screen is shown on the next page.
For an explanation of the settings, please see
below.

User Guide Page 6
yMerge: Select HTP or LTP merge when
2 controllers send data to this port (for
more information, see ‘Merging’ section
on page 8).
yPriority (active if IP & sACN are
selected): Set the Priority number (1-
200) that is used when converting DMX
to sACN
yLabel: Editable eld for port name
Figure: netLynx quad internal web server
The settings are explained above.

Page 7netLynx quad User Guide Page 7
DMX-Workshop
DMX-Workshop™ is a fully featured network
management, analysis, conguration and
diagnostics tool for lighting networks. You can
download the free software from our website.
When netLy nx quad is c o nnec ted to a computer
running DMX-Workshop, it should be detected
and displayed as an Art-Net node (click the
‘Node List’ tab to verify this). The node can be
expanded to show the conguration and DMX
output information, as shown below.
On a complicated network it is not always
easy to relate what is showing on screen to
the physical location of the nodes. A single
press of the factory reset button on artLynx
quad causes the product to send a message
over the network to the console.
Squawk
IP Address Conguration
Choosing the ‘Congure IP Address’ in the ‘Advanced’
menu brings up a window that shows the IP and Subnet
Mask.
The IP uniquely identies any nodes or controllers on a
network, while the Subnet Mask denes which part of
the IP represents the network address and which part
represents the node address. For example, a Subnet Mask
of 255.0.0.0 means that the rst byte of the IP denes the
network address and the remaining 3 bytes dene the Node
address.
By default, the product has a static IP address in the range
2.x.x.x. There are situations in which the user may wish
to change this - for example, a 192.168.x.x address is
generally used in oce environments.
A useful additional feature is the ability to enable automatic
IP address allocation on networks controlled by a DHCP
server (check the ‘Enable DHCP’ box to activate).
Right-clicking on any entry
brings up a menu that oers
various functionality:
yT h e ‘C o n gu r e No d e’ o pt i o n
enables conguration of
the universe number (port
address), protocol (Art-Net
or sACN), sACN priority,
failover mode, product
name and port labels.
y‘Copy to clipboard’ enables
all the node information to
be pasted into a support
request email.
y‘Merge Controls’
(selectable only on
individual DMX outputs)
enables the choice of LTP
(latest takes preference)
or HTP (highest takes
preference) merge modes.
y‘Indicators’ enables
selection of normal,
identify or mute for the LED
indicators. Normal is the
default behaviour, identify
causes the power LED to
ash, and mute turns o all
the LEDs.
y‘RDM Devices’ oers
options for device discovery
and conguration.
y‘Advanced’ leads to
‘Programme Upload’ and
‘Congure IP Address
and DHCP’ as described
opposite.
Figure: netLynx quad as viewed in DMX-Workshop

Page 8netLynx quad User Guide
Merging
netLynx quad is able to merge two streams of data to a DMX output. Depending on the settings,
merge can operate as HTP/LTP or Priority.
In HTP (highest takes precedence), the levels of each channel in the two streams are compared
and the highest value is used.
In LTP (latest takes precedence), the levels of each channel in the two streams is compared to
the output; if there is a change, that level is output.
In Priority, the sACN Priority eld denes which universe will be output.
Art-Net
If two streams from dierent IP addresses are directed to the same Port-Address, merging will
occur. If more streams are directed to the same Port-Address, they will be ignored.
sACN
Merging can operate with both unicast and multicast data.
If two streams from dierent IP addresses are directed to the same universe, the priority eld
is checked and the stream with the highest priority is output. If the priority eld in both streams
is identical, merging will occur.
If additional stream(s) are directed to the same universe, any additional stream with higher
priority will take precedence. If the priority is identical to the merging streams, it will be ignored.
DMX Input
A DMX input can be merged with an Art-Net stream, an sACN stream or another DMX input.
The table below summarises the merging operation.
Please refer to Application Note “0130 Gateway merging” for details:
https://artisticlicence.com/application-notes/
Table: Merging operation

Page 9netLynx quad User Guide
LED indication
netLynx quad features various LED indicators, which give dierent informational signals
depending on whether the product is booting up or in operational mode. The meanings are
explained below.
Net & Link LED:
OFF = Not connected
Yellow = Connected but no lighting data
Green = Art-Net / sACN on network
Power LED:
OFF = Not connected
Green (solid) = Good power
Green (ashing) = Identify**
Red = Fault condition
DMX LEDs:
OFF = No data is being
sent to this port
Green = Lighting data is
being output on this port
**The Power LED will ash continuously when the Identify command is sent by
DMX-Workshop. This enables netLynx quad to be easily distinguished on a network
containing multiple nodes. This LED will also blip briey in response to any programming
command received via the network.
During boot-up
During operation
yPower LED
- Slow ashing green (1Hz) = booting normally
- Slow alternating green/red (1Hz) = factory start (settings cleared)
yPower LED
- Static green = powered, normal operation
- Fast ashing green (5Hz) = identify**
- Occulting green = remote programming command received
- Static red = fault condition
- Fast alternating green/red (5Hz) = product is not commissioned (return for service)
yNet & Link LED
- Yellow = network link established (but
no lighting data)
- Green = Art-Net or sACN detected
yLEDs 1, 2, 3 & 4
- Green = Data activity
yAll indicators
- O = mute command received

Page 10netLynx quad User Guide
RDM Integrity
RDM Integrity is a software product from Benjamin Electric Co. designed for testing RDM
compliance. The product is targeted at manufacturers and developers wishing to ensure that
their products are compliant before being placed on the market. It provides a simple pass,
advisory, warning or fail assessment, along with decoded data that allow quick identication of
any problems.
Customers who have purchased RDM Integrity can use netLynx quad to unlock its powerful
RDM and Art-Net testing capabilities, as shown in the diagram below.
netLynx quad
netLynx quad

Page 11netLynx quad User Guide
netLynx quad Specication
Mechanical
yMounting: Flange or Desk
yMaterial: Flame retardant black ABS
(UL94V-0)
yOverall Dimensions: 156mm (W) x 118mm
(H) x 58mm (D)
yMounting centres: 171.5mm x 89mm (4
no. M4)
yMass: 0.2 kg
yCountry of manufacture: UK
Environmental
yOperating temperature: 0°C to 40°C
yStorage temperature: -10°C to +50°C
yOperating relative humidity (max): 80%
non-condensing
yIP rating: IP20 indoor use only
yCertication: CE, WEEE, RoHS
yWarranty: 2-year (return to base)
Power & Electrical
yInput voltage: 12-48 VDC or PoE
yInput connector: XLR4 (1 no.)
yInput power (max): 2W
yDC fuse: internal resettable fuse for
control electronics
Ethernet
yType: 10BaseT and 100BaseT
yIsolation: 1 kV
yPoE: supported (IEEE 802.3af - 2003)
DMX512 Ports
yOutput mode: oating
yOutput isolation: n/a
yOutput ESD protection: 15 kV
yElectrocution protection: 425 VAC
continuous connection (self-healing)
Control Protocols
yEthernet: Art-Net, sACN, RDMnet LLRP
yOutput: DMX512, DMX512 (1990),
DMX512-A, RDM V1.0 (E1.20 - 2010)
yInput: DMX512, DMX512 (1990),
DMX512-A
Data Connections
yRJ45 ethernet (1 no.)
yXLR5 DMX ports (4 no.)
LED Indication
yPower / Network Activity / DMX Activity
Conguration
yInternal web-browser or DMX Workshop
yManual factory reset / squawk button
Package Contents
ynetLynx quad
Ordering Info
yProduct code: netLynx quad
Accessories (not included)
yPSU-24-0.75-XLR4
yAr t-Switch PoE4 & PSU- 48-1-DR (powers
up to 4 x netLynx quad)
yGender 5MM

Warranty
All products are covered from date of purchase
by a two-year return to base warranty.
By return to base, we mean that the customer
is responsible for all costs of transport to and
from Artistic Licence.
Returns will not be accepted without prior
authorisation. In order to discuss a request to
return goods, please email:
Sales@ArtisticLicence.com
CE Compliance
netLynx quad is CE compliant
Compliance
All Products manufactured or sold by
Artistic Licence Engineering Ltd are fully
compliant with the appropriate CE and RoHS
regulations. Product specic information is
available on request.
Waste Electrical & Electronic Equipment
(WEEE)
Artistic Licence is a member of a WEEE
compliance scheme and will happily recycle
any of our products that you, at your expense,
return to us.
Due to our policy of continuing product improvement
specications are subject to change without notice
Artistic Licence
The Mould Making Workshop
Soby Mews
Bovey Tracey
TQ13 9JG
United Kingdom
Telephone +44 (0) 20 8863 4515
Email: Sales@ArtisticLicence.com
Web: www.ArtisticLicence.com
Support@ArtisticLicence.com
Table of contents
Other Artistic Licence Gateway manuals