Aseko ASIN AQUA Oxygen User manual

USER MANUAL
www.aseko.com
ASIN AQUA®Oxygen
POWER OF SYNERGIE
for crystal clear pool water without chlorine
EN 1
EN

CS
2
Basic Safety Instructions
This User Manual includes the basic safety instructions and information for
erection, commissioning, operation and maintenance of the ASIN Aqua device
(hereinafter referred to as “Device”). Therefore, before using Device, each
person, in particular that executing its erection, commissioning or maintenance,
and each its user unconditionally has to read this User Manual. This User Manual
has to be kept for later consultation and always available for all the users of
Device. All the safety instructions and information given in this User Manual shall
be unconditionally followed.
Risk of Non-Observance of Safety Instructions
Failure to observe the safety instructions given in this User Manual can result in
damage to Device and/or health and property, including environment.
Failure to observe the safety instructions and information given in this User
Manual shall result in exclusion or restriction of the prospective right to
compensation for damage.
Insufficient Qualifications of Persons Using Device
Unauthorised use of Device can result in damage to health and property. Device
erection andcommissioning shall exclusively beperformed bya skilled technician
or service company. A person performing Device erection and commissioning
shall train the user to such an extent that the user fully understands all the
risks related to incorrect manipulation of Device. Persons having insucient
qualification and knowledge of Device shall be denied access to Device and
manipulation of it. Furthermore, children and persons with reduced physical,
sensory or mental abilities are not allowed to use and handle Device unless they
are under supervision.
Overdose of Chemical Agents
Uncontrolled overdose of chemical agents can result in damage to health and
property. Despite the fact that Device includes a number of safety elements,
occurrence of overdose of chemical agents for water treatment cannot be
excluded in case of a failure of measuring probes or the entire Device. Install
Device so that uncontrolled overdose of chemical agents cannot occur and be
recognised in time before damage takes place. It is necessary to use chemical
agents in such concentrations and stock amounts that prevent their dangerous
concentration from being formed in water in case of a possible overdose. Do
not use too large packages of chemical agents or highly concentrated chemical
agents.
Formation of Chlorine Gas during Dosing of Chemical
Agents to Standing Water
If the checking flowmeter of Device is blocked or broken, there is a risk of dosing
chemical agents to standing water. In this case, a toxic chlorine gas is produced
by mixing of chlorine disinfection and pH reducing agent. The chemical agents
are not allowed to be dosed to standing water.

CS
3
Misapprehension of Safety Instructions and Information
This User Manual includes a large amount of safety instructions and
further information text. Failure to observe safety instructions as a result of
misapprehension may result in damage to health and property. Carefully read
the entire User Manual. Do not manipulate Device unless you are able to exclude
all potential hazards resulting from misapprehension of safety instructions and
other information.
Use of Device New Functions
Considering ongoing development, Device may include functions that are
not fully described in this version of the User Manual. The use of these new or
advanced functions without being fully comprehended by the user may lead to
Device damage and other serious consequences, including damage to health
and property. Make sure that all the users comprehend all the Device functions.
Conditions to be Met before You Start Using Device
Check whether you have the updated version of the User Manual and other
documentations for all the Device functions. Use the integrated help of Device.
If, on the basis of available information, you cannot fully comprehend some
functions of Device, do not use them.
Install ASIN Aqua in a covered, dry place far away from dust and high humidity
and make sure that all the electric connection are safe.
Do not attempt to open ASIN Aqua, do not replace any of internal parts. This
would damage electrical integrity of ASIN Aqua.
Handling of Chemical Agents for Pool Water Treatment
The chemical agents must be handled in a safe manner in order that no damage
or injury could occur. Aseko recommends to always use personal protective
equipment during manipulation of pool chemistry. For instructions, see the
safety data sheets (SDS)
WARNING: Never allow a pH agent to be mixed with Chlorine disinfection or any
other chemical (chlorine gas, which is toxic, could release). In maintaining plastic
tubes or valves, always rinse them with water to prevent them from being mixed.
RECOMMENDATION: Before using the pool, make sure that water parameters
are suitable for bathing using an Aseko hand tester.

CS
4
Box Content
Knife for cutting of
interconnecting hose
Interconnecting hose 15m 1/4”
(6.35 mm) - transparent #12008
Flowmeter #12106
Peristaltic pumps #12093
Probe housing #12013
Measured water filter #12090
Dowels
and screws #12125
Closing valves 2 pcs #12006
pH TESTER
Aseko Pool Technology
TESTER pH
HAZARD,GEFAHR,
DANGER,NEBEZPEČÍ
pH
Storein dr y and dark place
An einem trockenenund dunklen Or t aufbewahren
Stockerdans un endroit sec et sombre
Skladujte v suhcu a temnu min. +5°C max. + 30°C
Producer:ASEKO spol. s r.o.
Videnska340, 252 50, Vestec, CZE
Tel:+420 244 912 210
aseko.com
Expiration date
on the cap.
Content:20 litres
05
PP
ETHANOL SOLUTION
(ETHYL ALCOHOLSOLUTION)
UN 1170
pH testerWrench socket for
probes #13046
OX tester
#12177
Device
ASIN AQUA Oxygen
Injection valve 4 pcs #12005
Long Life pH probe #12012 Water thermometer with housing #12010 ZPM Coagulation mixer #30001
1/2”-1/4” adapter #12009
Weight into barrel 4 pcs #12023

CS
5
Accessories Available for Purchase
Chemistry Available for Purchase
20 l volume for pools
5 l volume for whirlpools
OXY PURE #13038
OXY PURE #13039
ALGICID #12156
ALGICID #12157
pH MINUS #12130
pH MINUS #12131
pH PLUS #12120 FLOC+C #12139
FLOC+C #12138
External touch display #12048 Pressure-type level gauge #12086
Air thermometer #12010
pH 7.00 Buer #12065Inserting DN50 plug
G1/4” threaded #12134

CS
6
ASIN AQUA Oxygen
POWER OF SYNERGY
for crystal-clear and chlorine-free water
The principle is above all based on perfect removing of all the impurities as
well as larger bacteria by filtering. It is due to a unique mixture of coagulant
and flocculant FLOC+C, which after having been sprayed in ZPM (coagulation
mixer) shall gather even the smallest impurities to create larger floccules that
shall subsequently be perfectly removed by the special AFM (Activated Filter
Media). Thanks to the perfect mechanical treatment of water, it is sucient to
use minimum chemistry to keep water clean and safe. The basis for disinfection
and removal of algae is the modern polymeric ALGICIDE being non-oxidative,
hence very comfortable for skin. The OXYPURE preparation then only serves for
oxidation of water and its sparkly appearance.
Pool water treatment
Well-balanced combination of all treatment aids will provide
cleanand crystal clear water
OXY Pure
Active oxygen for clean and crystal-clear water.
pH control
ASIN AQUA Oxygen makes it possible to dose pH MINUS or pH PLUS. Acurate
measuring by pH probe combined with the system digital inteligence assures
the required water quality.
ALGICIDE
The eective polymeric biocide protects water against algae, fungi, moulds and
bacteria.
FLOC+C
FLOC+C contains flocculation and coagulation components. Its continual dosing
improves filtration capability of removing even the smallest impurities.

CS
7
Pool control functions
Filtration Time Control
Daily, automatic start of the filter pump, as required, by means of the time interval.
Water Level - Refilling
Water level is controlled by level gauge #12086. As required, it switches water
refilling on and o. If water level is too low, it switches refilling on, if water level
is too high, it activates backwashing (this requires an automatic backwashing
Besgo valve).
Filter Backwashing
The filter backwashing time interval can be adjusted (this requires an automatic
backwashing Besgo valve).
Water Temperature Control
The system can control water temperature by switching heating on (electrical
heating, gas heating, heat exchanger).
Freeze Protection
Unless you want to empty the pool during the winter season, this function can
ensure protection of the pool against freezing.
Remote control by External touch display
Some of ASIN AQUA Oxygen functions can be remotely controled by External
touch display. System must be extended with the External touch display
#12048.

CS
8
Aseko Web Services
The system can be connected to Internet using the integrated power adapter.
You can easily monitor data of your pool on the route at
http://ipool.aseko.com or using the iPool Live application.
iPool Live application
iOS and Android smartphone application that gives you overview of your pool
status wherever you are connected to internet. User friendly and sophysticated
graphic enables easy selection of items to be monitored and preset the value
limits to send alerts at your smartphone. ASIN AQUA Oxygen will automatically
generate alert to your smartphone if any of selected items exceed the
individually preset limits or in case any system failure so you can call for action
to keep your pool in condition if necessary.
You can easily control quantity of chemical aids in the system tanks and monitor
the low minimum to order refilling.
http://ipool.aseko.com
Web application for detailed monitoring of water quality and system events on
the timeline. You can monitor in details all measured values, system events and
actions at simple and precise line diagrams for 30 days back in the timeline..

CS
9
Enhancement of filtering efficiency
AFM®activated filter media
AFM is direct substitute for filter sand. It doubles eciency of the existing
filtration system. AFM®is resistant to biological pollution and formation of so-
called bio-film.
ZPM®coagulation mixer
ZPM increases eects of coagulation and flocculation for transition of smaller
dissolved solids (turbidity) to larger particles that can be removed by filtering.
- -
-
--
---
- -
-
--
---
- -
-
--
---
- -
-
--
---
- -
-
--
---
- -
-
--
---
- -
-
--
---
- -
-
--
---
+
+
+
+
+
+
+
+
- -
-
--
---
+
+
+
+
+
+
+
+- -
-
--
---
+
+
+
+
+
+
+
+
- -
-
--
---
+
+
+
+
+
+
+
+
- -
-
--
---
+
+
+
+
+
+
+
+
- -
-
--
---
+
+
+
+
+
+
+
+
- -
-
--
---
+
+
+
+
+
+
+
+
+
Coagulation
(inorganic coagulant)
< 1 second
Flocculation
(polymeric flocculant)
approx. 3 minutes
Filtration
(AFM - Activated
Filter Media)
ZPM
(Zeta Potential
Mixer)
Polymeric flocculant
causes that neutral
particles join together to
create solid floccules.
Solid floccules are
easily caught by
filter media.
A zeta charge of
suspended particles is
neutralised in ZPM.
Inorganic coagulant and
polymeric flocculant
FROM POOL
TO POOL
Turbid water
(colloidal suspension)
The zeta potential keeps fine
particles dispersed
in water.

CS
10
ASIN AQUA Oxygen Installation
ASIN AQUA Oxygen is to be wall mounted in dry and dust-free environment
with temperature ranging from +5 °C to +40 °C. Install the mounting rail, which
serves for attachment, to the wall. Select location so that free space at least 40
cm in all directions and height above floor at most 150 cm are provided. Drill
three holes in the wall at the distance of 18.5 cm.
Use screws supplied with ASIN AQUA Oxygen for attachment.
WARNING: The location temperature should permanently be in the range from
+5°C to +40 °C.
Direct sunlight, high humidity and dust may lead to damage to
ASINAQUAHome.
• Before installing, ensure that pool water is chemically clean and free
of dirt.
• The maximum distance of injection valves from peristaltic pumps of
ASINAQUAHome must not be greater than 8 m.
• Vertical distance between ASIN AQUA Oxygen and the bottom of containers
must not exceed 2 m.
CHLORINE pH ALGICID FLOCC
40 °C
max.
5 °C
min.
40 cm
40cm 40 cm
40 cm
150 cm
18,5 cm 18,5 cm
max 8 m
max 2 m
CHLORINE pH ALGICID FLOCC
CHLORINE pH ALGICID FLOCC

CS
11
Installing the Probes
1. Carefully insert the probe into the housing.
2. Hand tighten or use the attached plastic wrench socket for probes.
3. Connect the connector and lock it by tightening a connector ring.
After the probe have been inserted, slightly tightened and connectors have
been connected, ASINAQUAOxygen is ready for connection to the water
system of your pool.
WARNING: Only hand tighten the probe or use the attached plastic wrench
socket for probes. Do not use pliers or steel wrench.
Klíč na sondy
#13046
Jímka sondy #2013
pH sonda Long Life
#12012
Wrench socket for
probes #13046
CLF probe for free chlorine
# 12052
pH probe
housing #12013
pH Long Life probe
#12012

CS
12
Pool Water Connection
The pool water to be measured must be connected to ASIN AQUA Oxygen.
Connect the measured water inlet downstream of the pump, upstream of the
filter and ZPM (coagulation mixer).
Place the water valve fitting to the T-joint, blinded by DN50 G1/4” threaded plug
#12134.
• The connecting fitting is installed in G1/4” thread.
Aseko provides the unique Speedfit connecting fitting for measured water
connection to your ASIN AQUA Oxygen. To connect the interconnecting
tube, push it into the Speedfit connector and then lock it by pulling back. To
disconnect the interconnecting tube, push and hold a circular collet and pull the
interconnecting tube out.
WARNING: To treat PE tube ends, use a sharp knife (part of delivery). The use
of scissors or tongs deforms the tube end and leads to leaks.
WARNING: Only hand tighten. Do not use tongs or any other tools.
1. To ensure tightness of joints, cut the tube at 90 ° angle.
• Use the sharp knife to cut plastic. The cut must be clean and smooth.
2. Connect the water inlet to the measured water filter connection and the
water outlet to the probe housing connection. Make sure that measured
water pressure does not exceed 1.5 bar.
3. The water outlet can be realized:
1. downstream of filtration
2. to non-pressure (overflow tank)
3. upstream of filter pump
Water valve
fitting
G1/4” thread 6.2x4 hose
CONNECTION
LOCKING
DISCONNECTION
Water valve fitting
Inserting DN50
plug
G1/4” threaded
T-joint
6.2x4 hose
90°
Pull out

CS
13
THE WATER OUTLET CAN BE
REALISED:
1. downstream of filtration
2. to non-pressure (overflow tank)
3. upstream of filter pump
POOL
WATER OUTLET
POOL
WATER INLET
Thermometer
ZPM
(Zeta
Potential
Mixer)
Besgo
FROM POOL
HeatingTO POOL

CS
14
Pool Chemicals Connection
At this step is necessary to connect the injecting valves of individual chemicals
to the dosing pumps and dosed agents.
Place the injecting valve in the T-joint, blinded with the DN50 G1/4” threaded plug
#12134.
1. Cut the PE tube at 90 ° angle to ensure proper fitting.
• Use the sharp knife to cut plastic. The cut must be clean and smooth.
2. Drill the 6 mm hole and the 1 mm hole (air suction) into the CHLORPURE
canister cap. Push the PE tube through the cap. Select the tube distance
so that the tube reaches the canister bottom and can be connected to the
pump as straight as possible. A long tube in the canister would bend and
produce air bubbles.
3. Put a weight on the tube end and dive it in the canister.
4. Connect the plastic tube from the CHLORPURE canister to the
ASINAQUAHome pump (marked as 1 CHLORINE) to the left connection.
5. Connect the plastic tube to the 1 CHLORINE pump right connection and the
injection valve.
6. Hand screw the CHLORPURE injection valve in the specified mounting hole
(see diagram).
• The injection valve is installed in G 1/4” thread.
To connect dosing of pH, algaecide and flocculant, repeat steps 1 to 6 for other
pumps according to their marking.
• Check throughput of the injection valves and tightness of the entire system
(see installation test).
WARNING: Only hand tighten. Do not use tongs or any other tools.
Ø 1 mm
Ø 6,3 mm
Ø 1 mm
Ø 6,3 mm
Ø 1 mm
Ø 6,3 mm
T-joint with inserting
DN50 plug G1/4”
threaded
Injecting valve
Drills

CS
15
Odpad
Besgo
Ohřev
Teplomě r
DO BAZÉNU
Z BAZÉNU
ZPM
koagulační
mixer
Thermometer
ZPM
(Zeta
Potential
Mixer)
Waste
Besgo
FROM POOL
TO POOL Heating

CS
16
Accessories connection
1
12V
23456789
GND
T800mA
16 17 18 19
L L N N
T125mA
Externí displej
RS 485
Teploměr vody
Teploměr
venkovního
vzduchu
Relé topení
Solenoid dopouštění
Besgo ventil
Hladinoměr
Pomocný kontakt rolety
Sepnuto – zavřená
Rozepnuto – otevřená
Modul pro variabilní čerpadla (*volitelně)
Průtokoměr
Filtrační
čerpadlo
s variabilní
rychlostí
GND
n1 n2 n3
STOP
M
230 Vac
RCD
Proudový
chránič
30 mA
Max 1,4 kW
230 v~
230 V / 50 Hz
Besgo valve
Refilling solenoid
Heating relay
Flowmeter
Water
thermometer
Outdoor air
thermometer
External display
RS 485
Filter pump with
variable speed
Variable speed pump module (*optional)
Roller shutter auxiliary contact
Connected - closed
Disconnected - opened
Water level
sensor

CS
17
Power Supply
Connection to the mains:
1. Leave the mains switch in the o position.
2. Connect the filtering device to the ASIN AQUA Oxygen switched socket
outlet (filtration power supply - max. 1.4 kW / 230 VAC).
3. Connect the 230 V / 50 Hz mains cable to ASIN AQUA Oxygen (on the right
side). The mains socket outlet must be protected by a residual current
device (RCD).
4. Change the mains switch over to the on position.
After Device has been switched on, the display will come on and the ASIN AQUA
Oxygen starting screen will appear.
Disconnection from the mains:
1. Change the mains switch over to the o position.
2. Disconnect the ASIN AQUA Oxygen mains cable from the 230 V / 50 Hz
socket outlet.
3. Disconnect the filtering unit mains cable from ASIN AQUA Oxygen.
WARNING: If Device is used in the manner dierent from that specified by the
manufacturer, protection provided by Device may get damaged.
Power supply 230 V/ 50 Hz
Power consumption 24 VA
Power consumption (including filter pump) 1449 VA
Max. input power of connected pump 1,4kW / 230 V AC
Fuse T800 mA; T160 mA; T6,3 A
Over-voltage category II
Ingress protection IP30
Operating temperature +5 až +40 °C
Weight 6,7 kg
Installation wall mounted
Relay output contacts max 230 V / 1 A,
voltage free
Discharge of dosing pumps 10 and 60 ml/min / max. 1bar
Measured water pressure max. 1 bar
(no underpressure required)
Dimensions 430 x 330 x 160 mm
RCD
Proudový
chránič
30 mA
Max 1,4 kW
230 v~
230 V / 50 Hz
Residual
current device,
30 mA
230 V / 50 Hz
Max. 1,4 kW
230 v~

CS
18
ASIN AQUA Oxygen
Installation Test
WARNING: Any obstacles, bubbles or leaks in the connecting tube will prevent
ASIN AQUA Oxygen from correct operating. The clear plastic tube allows you to
monitor flow of liquid to the injecting valves.
Before commencing the operation, test ASIN AQUA Oxygen installation. Most
problems result from incorrectly performed installation.
Test
In the “Test of Outputs” menu, gradually start all the pumps and while they are
running, check tightness of all the PE tube connections. Check the injecting
valves for blockage and air bubbles in the PE tube.
DO NOT FORGET! Provide the testing run and stop of all accessories
connected to ASIN AQUA Oxygen. At this step just test, do not dose the
aids or provide the initial dose of chemicals!
Initial dose
in following steps
1.
3.
2.
Check tightness of all the
connections.
Liquid must reach spraying and
subsequently the tube.
If bubbles occur here, the
pump draws air in. Repair the
connection - disconnect the
tube, cut the end carefully in
90° angle and plug it back.
Monitor level in the
transparent plastic
tube.

CS
19
Control
Basic Screen
It shows measured, required values and status information.
For example, click the box OXY to display setting of the required value.
Controls
Settings
Movement through Menu
Value Settings
Value Measured.
The chlorine pump status – ON.
Movement in menu to the previous page.
Indicator of the current page and the total number
of pages.
Movement in menu to the next page.
ON - function is
switched on
OFF - function is
switched o
Back to the main screen. Displays help/manual for
the particular screen.
Back to the previous
screen.
Reduces the value. Increases the value. Saves the
adjusted value.
Manual control allows to:
switch filtration on/off
independently to preset
filtering periods.
start filter washing
independently to adjusted
washing time.
ON/OFF indicates the
current status of filtration.
The timer allows to set the
control mode and adjust
filtering periods.
ON - filtering follows
adjusted period.
NONSTOP 24 h – filtering
in operation for 24 hours
uninterruptedly.
Enter settings.

CS
20
Configuration
Date and Time
To ensure the correct function of timers, set the current date and time.
Pool Volume
To ensure the correct function of ASIN AQUA Oxygen, enter the correct volume
of your. Calculate your pool volume in m3:
Length (L) times width (W) times depth (D) is volume (V) - (L×W×D=V).
Enter the value using + and - buttons.
WARNING: The pool volume has eect on the maximum safe dose, enter the
correct value.
Filtration Timer
Filtration can be set to NONSTOP operation for 24 hours or to one, maximum to
two time periods.
Variable Pump Control
ASIN AQUA Oxygen allows to control the SPECK or PENTAIR variable output
circulating pumps. The pump runs at speed 2 in filtering periods, besides the
preset filtering (when the standard pump is o) it runs at speed 1 (or can stay
switched o according to your choice). In case of backwashing, the pump is
running at speed 3.
Individual speeds 1, 2, 3 are adjusted directly on the pump according to the
respective pump manual.
Automatic Filter Washing
Considering that the ASIN AQUA Oxygen technology is in particular based
on the high eciency of filtering and removing even the finest impurities, it
is necessary to wash the filter on a regular basis. The automatic washing
function ensures the filter washing on a regular basis in the preselected
intervals.
To enable this function, it is necessary to use the automatic 5-way
BESGO valve. Its moving is enabled by the relay No. 17 switching on. When
the relay switches on, the BESGO valve is enabled and moved to the required
position by the action of pressure water or air. See the BESGO manual.
Other manuals for ASIN AQUA Oxygen
1
Table of contents
Other Aseko Swimming Pool Filter manuals
Popular Swimming Pool Filter manuals by other brands

Pentair
Pentair QUAD D.E. Series Installation and user guide

Jandy Pro Series
Jandy Pro Series TruClear Installation and operation manual

emaux
emaux ICF 230 Installation & operation

Pentair Pool Products
Pentair Pool Products Piscinas Pro FR Series Installation and operation instructions

POLYGROUP LIMITED
POLYGROUP LIMITED RS600 Filter System with F600C Pump instructions

Pool Frog
Pool Frog Pool Frog XL PRO 5450 instruction manual