General safety information
This user manual contain basic information that should be observed during assembly, start-up, operation,
and maintenance. Therefore, this user manual must be read by installers and operators prior to assembly
and start/up, and must be accessible to every user of this unit. Additionally, all further safety information
in this document absolutely must be observed. Read and follow all instructions. In order to minimize the
danger of injury, do not allow children to use this product. Hazards from non-compliance with safety
information. Non-compliance with safety information can result in hazards to persons, the environment,
and the equipment. Non-compliance with safety information will result in a forfeit of any potential right to
damage compensation.
Insufficient personnel qualification
Hazards in the event of insuciently qualified personnel, potential consequence: Injury, heavy material
damage.
•
The system operator must ensure compliance with the required qualification level.
•
Any and all work may only be performed by correspondingly qualified personnel.
•
Access to the system must be prevented for insuciently qualified persons, e.g. via access codes
and passwords.
Potential overdosing of chemical agents
Despite ASIN Aqua® comprehensive safety functions, it is possible that a probe failure and other errors
could lead to an overdosing of chemical agents. Potential consequence: Injury, heavy material damage.
•
Design your installation such that uncontrolled dosage is not possible in the event of a probe failure
or other errors, and/or such that uncontrolled dosage is recognized and halted before damage is
incurred.
•
Uncontrolled overdose of chemicals can cause harm to health and property. Even though the device
contains a number of security elements can not be ruled out that in case of failure of the measuring
probes, or the whole device may result in overdose of chemical agents. Install the equipment so
that uncontrolled overdose of chemicals was not possible and that uncontrolled overdose has been
detected in time before causing any harm. It is necessary to use chemicals in such quantities that an
overdose will not cause dangerous concentration of chemical agents. Do not use chemicals in too
large packages or with too high concentration.
Gaseous chlorine produced from dosing in standing water if dosing
outputs are not closed via the filter pump
If the flow switch is stuck or experiences another error, there is a risk of dosing into standing water.
Poisonous chlorine gas can be yielded when sodium hypochlorite and pH minus come together.
Non compliance with informational text
There is a great deal of informational text indicating hazards and their avoidance. Not observing informational
text may lead to hazards. Potential consequence: gravest degree of injury, heavy material damage.
•
Read all informational text carefully.
•
Cancel the process if you are unable to exclude all potential hazards.

EN 3
Use of new functions
Because of the continued development, a ASIN Aqua® unit may contain functions, which are not
completely described in this version of the user manual. The use of such new or extended functions
without a profound and secure understanding by the operator may result in malfunctions and severe
problems. Potential consequence: Injury, heavy material damage.
•
Make sure to get a profound and secure understanding of a function
and relevant boundary conditions, before you start to use it.
•
Check for an updated version of the user manual or additional
documentation available for the relevant functions.
•
Make use of the integrated help function of the ASIN Aqua® to get
detailed information on functions and their parameter settings.
•
In case it should not be possible to get a profound and secure understanding of a
function based on the available documentation, do not use this function.
Overdosing if pH value is wrong
If disinfection is enabled before the pH value is stable in the ideal range of 7.0 to 7.4, then it may lead
to heavy overdosing of chlorine or bromine. Potential consequence: Injury, heavy material damage.
•
Do not start disinfection with chlorine until the pH value is
stable in the ideal range between 7.0 and 7.4.
Conditions before using
Make sure you have a newest and updated version of the user manual and other documentation for
all functions of the unit. Use and read the integrated help features. In case of not understanding the
information about certain features of the unit, do not use these features.
Handling chemicals for pool water treatment
The chemicals used with the ASIN Aqua must be handled in a safe manner to prevent damage or personal
harm. Aseko recommends you always use personal protective safety equipment when handling the pH
and chlorine agents. Refer to the Materials Safety Data Sheet (MSDS).
WARNING:
Never mix the pH agent with the chlorine agent. When carrying out maintenance on
the clear plastic tubes or valves always rinse with clean water to prevent mixing of the pH and chlorine
agents.

EN
4
Thermometer
#13192
What’s in the box
Sharp knife for cutting
interconnecting hose
interconnecting hose
Dowels and screws
#12125
Peristaltic pumps
Peristaltic pumps
#12093
Water valves 2 pcs
#12006
Injection valve 2 pcs
#12005
Suction tube weight
2 pcs
#12023
PE Tube 1/4” (6.35 mm)
transparent
#12008
Wrench socket for probes
#13046
#13046
Probe pH Long Life
Probe pH Long Life
# 12012
# 12012
# 12012
# 12012
CLF probe
CLF probe
#12052
#12052
or
Redox probe Long Life
Redox probe Long Life
# 12016
# 12016
# 12016
# 12016
Flowmeter with filter
#12106
ASIN AQUA Net
ASIN AQUA Net

EN 5
Available optional accessories
Inserting DN50 plug
1/4” threaded #12134
pH 7.00 Buer #12065
Redox Buer #12063
External touch screen
#12048
Volume 20 l
Volume 5 l
pH MINUS #12131
pH MINUS #12131
CHLORPURE #12059
CHLORPURE #12059
pH MINUS #12130
pH MINUS #12130
CHLORPURE #12075
CHLORPURE #12075
ASEKO original chemical solution

EN
6
ASIN AQUA Net
ASIN AQUA NET CLF
# 12001
ASIN AQUA NET Redox
# 12144
ASIN AQUA NET Dose
# 12022

EN 7
ASIN AQUA Net
ASEKO’s ASIN AQUA Net gives you pool clean and sparkling water with the
minimum amount of chemicals. By directly measuring and controlling the
free chlorine content or redox potential of your pool water with advanced CLF
(free chlorine) or redox probe. ASIN AQUA Net tunes your pool water using the
minimum amount of chlorine, eliminating the smell and burning of overtreated
pools. With a touch screen interface, you have complete control over measu-
rement andregulation of your pool. ASIN AQUA Net operates with your existing
pool filtering equipment. ASIN AQUA Net works also on time dosing system for
chlorine-free oxygen based desinfection agent dosing as SANOSIL.
Pool water treatment
Well-balanced combination of all treatment aids will provide clean and crystal
clear water
Chlorine control and dosing
Highly eective disinfection treatment of pool water for public and private
pools. Extraordinary precise measuring of chlorine content in the pool water by
ASEKO CLF - free chlorine probe combined with the system digital intelligence
is able to control the preset disinfection level by usage of minimum necessary
chemical aids.
pH control and dosing
ASIN AQUA Net is adjustable to dose pH MINUS or pH PLUS. Treatment for
stabilizing of pool water acidity at the optimum level. Precise measuring by
pH probe combined with the system digital intelligence controls the preset
pH level of the circulating pool water in all pool operation modes and variable
environment conditions.

EN
8
40 °C
max.
5 °C
min.
3
0
c
m
3
0
c
m
3
0
c
m
3
0
c
m
1
5
0
c
m
23 cm
ø
8 mm
ø 8 mmø
m
a
x
2 m
m
a
x
8 m
ASIN AQUA Net Installation
ASIN AQUA Net is to be wall mounted in dry and dust-free environment with
temperature ranging from +5 °C to +40 °C. Install the mounting rail, which ser-
ves for attachment, to the wall. Select location so that free space at least 40 cm
in all directions and height above floor at most 150 cm are provided. Drill three
holes in the wall at the distance of 18.5 cm. Use screws supplied with ASIN
AQUA Net for attachment.
WARNING:
The location temperature should permanently be in the range from
+5 °C to +40 °C.
Direct sunlight, high humidity and dust may lead to damage to ASIN AQUA Net.
•
Before installing, ensure that pool water is chemically clean and free of dirt.
•
The maximum distance of injection valves from peristaltic pumps of ASIN
AQUA Net must not be greater than 8 m.
•
Vertical distance between ASIN AQUA Net and the bottom of containers
must not exceed 2 m.

EN 9
CLF probe for free chlorine
pH Long Life probe
pH Long Life probe
#12012
Redox Long Life probe
#12016
Schlüssel für
Sonden
Sonden
# 12052
CLF probe
or
Redox probe
housing
#12013
pH probe
housing #12013
Redox Long Life probe
#12016
Installing the Probes
1.
Carefully insert the pH, CLF or REDOX probes into the housing.
2.
Hand tighten or use the attached plastic wrench socket for probes.
3.
Connect the connector and lock it by tightening a connector ring.
After probes have been inserted, slightly tightened and connectors have been
connected, ASIN AQUA Net is ready for connection to the water system of your
pool.
WARNING:
Only hand tighten the probes or use the attached plastic wrench-
socket for probes. Do not use pliers or steel wrench.

EN
10
Pool Water Connection
The pool water to be measured must be connected to ASIN AQUA Net. Connect
the measured water inlet downstream of the pump, upstream of the filter and
ZPM (coagulation mixer).
Place the water valve fitting to the T-joint, blinded by DN50 G1/4” threaded plug
#12134.
•
The connecting fitting is installed in G1/4” thread.
Aseko provides the unique Speedfit connecting fitting for measured water
connection to your ASIN AQUA Net. To connect the interconnecting tube, push
it into the Speedfit connector and then lock it by pulling back. To disconnect the
interconnecting tube, push and hold a circular collet and pull the interconnecti-
ng tube out.
WARNING:
To cut PE tube ends correctly, use a sharp knife (part of delivery).
The use of scissors or tongs deforms the tube end and leads to leaks.
WARNING:
Only hand tighten. Do not use tongs or any other tools.
1.
To ensure tightness of joints, cut the tube at 90 ° angle.
•
Use the sharp knife to cut plastic. The cut must be clean and smooth.
2.
Connect the water inlet to the measured water filter connection and the wa-
ter outlet to the probe housing connection. Make sure that measured water
pressure does not exceed 1.5 bar.
3.
The water outlet can be realized:
1.
downstream of filtration
2.
to non-pressure (overflow tank)
3.
upstream of filter pump
After the water inlet has been connected and opened, your ASIN AQUA Net is
ready to measure and adjust the pH and Cl value in your pool so as to achieve
the required values.
Water valve
fi t t i n g
G1/4” thread
CONNECTION
LOCKING
DISCONNECTION
Water valve fitting
Inserting DN50
plug
G1/4” threaded
T-joint
90°
Pull out
6.2x4 hose
6.2x4 hose

EN 11
THE WATER OUTLET CAN
BE REALISED:
1. downstream offiltration
2. to non-pressure
(over-flow tank)
TO POOL
Heating
FROM POOL
POOL WATER
INLET
IN
OUT
Koagulations- mixer
Koagulations- mixer
Besgo

EN
12
Ø 1 mm
Ø 6,35 mm
Inserting DN50 plug
G1/4” threaded
Pic. 1
Pic. 2
Pic. 3
Pool Chemicals Connection
At this step is necessary to connect the injecting valves of individual chemicals
to the dosing pumps and dosed agents.
Place the injecting valve in the T-joint, blinded with the DN50 G1/4” threaded
plug #12134.
1.
Cut the PE tube at 90 ° angle to ensure proper fitting.
•
Use the sharp knife to cut plastic. The cut must be clean and smooth.
2.
Drill the 6 mm hole and the 1 mm hole (air suction) into the CHLORPURE
canister cap. Push the PE tube through the cap. Select the tube distance
so that the tube reaches the canister bottom and can be connected to the
pump as straight as possible. A long tube in the canister would bend and
produce air bubbles.
3.
Put a weight on the tube end and dive it in the canister.
4.
Connect the plastic tube from the CHLORPURE canister to the left connec-
tion of ASIN AQUA Net pump (marked as 1 CHLORINE).
5.
Connect the plastic tube to the CHLORINE pump right connection and
mount the injection valve at the other end.
6.
Hand screw the CHLORPURE injection valve in the specified mounting hole
(see diagram).
•
The injection valve is installed in G 1/4” thread.
To connect dosing of pH repeat steps 1 to 6 with the other pump according to
its marking.
•
Check throughput of the injection valves and tightness of the entire system
(see installation test).
WARNING:
Only hand tighten. Do not use tongs or any other tools.

EN 13
Max 8 m
Max 8 m
Max 8 m
TO POOL
Heating
FROM POOL
Besgo
Max 2 m
Koagulations- mixer
Koagulations- mixer

EN
14
Power Supply
Connection to the mains:
1.
Leave the mains switch in the OFF position.
2.
Connect the filtering device to the ASIN AQUA Net switched socket outlet
(filtration power supply - max. 1.4 kW / 230 VAC).
3.
Connect the 230 V / 50 Hz mains cable to ASIN AQUA Net (on the right side).
The mains socket outlet must be protected by a residual current device
(RCD).
4.
Change the mains switch over to the ON position.
After device has been switched on, the display will come on and the ASIN AQUA
Net starting screen will appear.
Disconnection from the mains:
1.
Change the mains switch over to the o position.
2.
Disconnect the ASIN AQUA Net mains cable from the 230 V / 50 Hz socket
outlet.
3.
Disconnect the filtering unit mains cable from ASIN AQUA Net.
WARNING:
If Device is used in the manner dierent from that specified by the
manufacturer, protection provided by cevice may get damaged.
Power supply
230 V/ 50 Hz
Power consumption
14 VA
Fuse
T80 mA
Over-voltage category
II
Ingress protection
IP50
Operating temperature
+5 to +40°C / 60%
Weight
2,2 kg
Installation
wall mounted
Measured and regulated value
Free chlorine or Redox, pH
Discharge of dosing pumps
60 ml / min / max. 1bar
Measured water pressure
max 1,5 bar
RCD
Current
protector
30 mA
230 V / 50 Hz
Timer
Filter pump
Pic. 1

EN 15
ASIN AQUA Net Installation Test
WARNING:
Any obstacles, bubbles or leaks in the connecting tube will prevent
ASIN AQUA Net from correct operating. The clear plastic tube allows you to
monitor flow of liquid to the injecting valves.
Before commencing the operation, test ASIN AQUA Net installation. Most
problems result from incorrectly performed installation.
Test
In the “Test of Outputs” menu, gradually start all the pumps and while they are
running, check tightness of all the PE tube connections. Check the injecting
valves for blockage and air bubbles in the PE tube.
DO NOT FORGET! Provide the testing run and stop of all accessories
connected to ASIN AQUA Net. At this step just test, do not dose the aids
or provide the initial dose of chemicals!
1.
2.
3.
Check tightness of all the
connections.
Liquid must reach spraying and
subsequently the tube.
If bubbles occur here, the
pump draws air in. Repair the
connection - disconnect the
tube, cut the end carefully in
90° angle and plug it back.
Monitor level in the
transparent plastic tube.

EN
16
Touch screen description
Home screen
The home screen displays measured, required values and status information.
E.g. click on the
Chlorine
tab to enter the setting of the required chlorine value
in pool water.
Required value
Time since last dose
mV output signal from
the CLF probe
Settings
Measured value
Dosing time in seconds
Info
Decrease value
Increase value
Back to home
screen
Language settings
Back to previous screen
Choose
Settings

EN 17
Nastavení parametrů bazénu
Each pool is unique. Temperature, size, location, and hardness of water all
aect how ASIN AQUA Net monitors and tunes your pool water. For optimum
performance, you must set your pool properties in ASIN AQUA Net. After you
select REQUIRED VALUES:
Pool volume
To ensure the correct function of ASIN AQUA Net, enter the correct volume of
your. Calculate your pool volume in m
3
:
Length (L) times width (W) times depth (D) is volume (V) - (L×W×D=V).
Enter the value using + and - buttons.
WARNING:
The pool volume has eect on the maximum safe dose, enter the
correct value.
Pool type
Choose a type of your pool.
Hard water
Set the pool water hardness in dH, 0-9 is soft, 9-21 is hard and 21+ is very hard.
Flowmeter
The flowmeter detects flow of measured water. Dosing of chemicals will take
action only if flow of measured water to probes is detected.
Wash the check flowmeter strainer on a regular basis.
Warning:
Only switch o the flowmeter in case of a failure.
Settings
Parameters -
pool volume, pool type, water hardness
Calibration -
pH probe, CLF probe, thermometer
Dosing test -
test pump and manual dosing
Chose the type of probe -
Chose the type of desinfection probe
Language -
Set the language of the ASIN AQUA Net

EN
18
Choosing the disinfection probe
1.
CLF free chlorine probe
2.
Measurement of redox potential, CHLOR PURE dosing
3.
DOSE ml/m3 time dose per hour or per day
Without a probe
Free chlorine measurement, CHLOR PURE dosing
2.
Redox probe
of the RX potential
Measurement of redox potential, CHLOR PURE dosing
3.
DOSE ml/m3 time dose per hour or per day
Setting Values
Commissioning procedure
The water in the pool must be clean without any additives. Ideally fill the
pool with fresh water from the water main.
1. Ensure the filtration system runs NONSTOP for 24
hours
•
Set the required values via the main screen by pressing the appropriate tab
(see the chapter Control):
•
If you have the CLF probe, set the disinfection to 0.0 mg/l. If you have the
REDOX probe, set the disinfection to 000 mV.
•
pH values leave at the factory setting for the time being (pH 7.0).
2. Close the water supply to the probes
ASIN AQUA Net displays „No water supply to the probes“ notification.
3. Perform superchlorination
Perform superchlorination of pool water with Super CHLOR (inorganic active
chlorine without stabilizers). Follow the instructions on the packaging (1 kg = 80
m³).
SuperCHLOR
SuperCHLOR
#13120

EN 19
4. Wait at least 1 hour. Optimally up to 24 hours.
Before opening the water supply
to the probes, the water must be
Before opening the water supply to the probes, the water must beBefore opening the water supply
clean
and the
chlorine concentration
measured by the colorimeter or Pool Tester
must be within the range
0.3 to 1.2 mg/l
.
If the
concentration is lower
, repeat superchlorination. If the
concentration
is higher
, wait till the chlorine concentration in the water drops down.
5. Open the water supply to the probes
The „No water supply to the probes“ notification will disappear from the ASIN
AQUA display.
6. pH adjustment
•
Set the required pH value ideally close to the pH value of the incoming
water.
•
ASIN AQUA Net adjusts the pH automatically according to the preset requi-
red value.
•
The ideal pH value should be between 6.8 and 7.5.
7. Depending on the type of a probe you have,
proceed according to the chapter:
•
If you have the CLF probe
•
If you have the REDOX probe

EN
20
If you use the CLF probe
For the correct functionality of the CLF probe you must observe the
following conditions:
pH of the pool water
The ideal pH value should be between
6.8 and 7.5.
The pH of the pool water must be stabilized.
If the pH value fluctuates, the value of the chlorine in pool water changes
accordingly.
Determination of the required chlorine value in pool
water
The required concentration of chlorine in pool water varies with the temperature
of the pool water. However, it should never be less than 0.3 mg/l. Determine the
required value using the table located on the left.
How to set the required chlorine value
Use a colorimeter or Pool Tester to measure the chlorine value in pool water
sample.
If the chlorine concentration (measured with a colorimeter or Pool Tes-
ter) is:
• ADEQUATE
to the value shown on the ASIN AQUA Net display
, your
device is ready to maintain the required concentration of chlorine in pool
water.
• BELOW
the required value shown on the ASIN AQUA Net display, in-
crease
the required value over the current setting by 0.1 (by 0.2 mg/l max)
(regardless of the required value according to the table).
Repeat the measurement after the water in the pool is mixed thoroughly and the
required value shown on the ASIN AQUA Net display is settled. Repeat the pro-
cess until the
chlorine concentration in pool water matches the required
value
then set the correct required value according to the table. Subsequently
you can calibrate the CLF probe (see the chapter CLF Probe Calibration).
• HIGHER
than the required value shown on the ASIN AQUA Net
display
- you can calibrate the CLF probe (see the chapter CLF Probe
display - you can calibrate the CLF probe (see the chapter CLF Probedisplay
Calibration).
NOTIFICATION:
Fix the low chlorine value in pool water by
increasing required disinfection
value
.
RECOMMENDATION:
Check the chlorine content in the pool once a week using the colorimeter or
tester.
Chlorine
Level mg/l
Water
Temperature
0,3 – 0,5
24 – 26 °C
0,5 – 0,8
26 – 32 °C
0,8 - 1
higher than 32 °C
This manual suits for next models
2
Table of contents
Other Aseko Swimming Pool Filter manuals
Popular Swimming Pool Filter manuals by other brands

Aquatic
Aquatic ALGAE SKIMMER quick start guide

Pentair
Pentair SMBW 4000 Series operating manual

Peraqua
Peraqua BREGENZ 2 Installation & operating manual

Hayward
Hayward hydrorite uvo3 troubleshooting guide

Behncke
Behncke B075 instruction manual

Deltec
Deltec MC 500 Operating instructions and spare parts list

Kripsol
Kripsol KLS 20 manual

Axiall
Axiall Accu-Tab 2300 Installation and operating instructions

SandPro
SandPro 4517 owner's manual

ProMinent
ProMinent DULCODOS Pool Soft Assembly and operating instructions

Messner
Messner Skimmer 200 operating instructions

Davey Water Products
Davey Water Products EcoSalt 2 DES2-15E Quick reference guide