Designed for use with standard 1½ ,1 or
/ gallon pouched condiments and toppings.
Pumps attach to 16mm tments in pouches.
Valve
9683
Dome Clip
7868
Pump Housing 13.5mm
9718
Nozzle
8651
According to food and safety regulations, most foods must be
stored and/or served at certain temperatures or they could become
hazardous. Check with local food and safety regulators for specic
guidelines. Be aware of the product you are serving and the
temperature the product is required to maintain.

• Intended for use between 50 -100 degrees Fahrenheit.
• Dispenser must be used on a horizontal surface.
• Dispenser must be installed in a location where it can be overseen by trained
personnel.
• Dispenser must be used with provided power supply.
• The dispenser shall not be placed where a water jet could be used for
cleaning.
• The appliance is not to be used by persons with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction.
• Children should be supervised not to play with the appliance.
• Place dispenser away from edge of counter to prevent potential drips from
reaching the oor. Wipe o any potential drips as they form.
• Clean pump every 24 hours
• Noise level: <70dB
3
Safety cont.
Pump Cleaning
All pump components are dishwasher safe.
All components must be cleaned before rst use.
Disassemble all ve (5) parts. Clean with soap and hot water, rinse, sanitize
and dry according to local sanitization requirements. Use supplied brush to
scrub inside parts.
Do not immerse the lid or power supply when cleaning.
Clean and sanitize exterior of shroud as needed.
IMPORTANT Clean, rinse, sanitize, and dry parts at a minimum of
every 24 hours. Always comply with local sanitization requirements.

4
Assembly
over the dome and pump housing.
Ensure that the tab on bottom of the dome
slides into the opening in the dome clip.
Insert the dome clip
3
into the pump housing.
Ensure the aps slide into place.
Press the entire dome rmly, including the
top portion.
Insert dome
2
onto the end of the pump housing.
Bend the outer portion of the nozzle
inside out.
Insert into opening. Tab of nozzle faces
towards housing. Flip the outer portion of
the nozzle over the end of tube.
Mount the nozzle
1

5
Put new pouch on counter top with
tment facing up. Place piercing end of
connector in center of the tment. Push
rmly until pump snaps into place.
Connect pump to pouch
5
into the bottom of the pump housing.
Wrap the aps on the side of valve onto the
pair of pegs on the pump housing.
TIP: Lubricate parts with clean water to
ease tting.
Insert valve
4
Hold the pump in an upright position.
Press the dome with both thumbs and let
it recover to starting state. Repeat until
product has reached the nozzle.
Prime the pump
6

6
9Wave hand over sensor to ensure pump is
primed and dispensing product.
Prime the Pump
8
Make sure pump is in place. Slide the
dispensing mechanism into the shroud
making sure that the unit sits in place
correctly.
Place the lid over the dispensing
mechanism.
Insert the Dispensing
Mechanism
Insert the Lid
into the dispenser shroud. Hold end of
pouch up while guiding the pump into
the slots inside the front of dispenser.
Insert pouch and pump
7

Unable to place the lid on the dispenser?
The dispensing mechanism includes a safety
switch that will freeze the actuator in posi-
tion if the lid is removed in the middle of
dispensing.
Reset the actuator:
1) Remove the pump and pouch from the
dispenser base.
2) Install the dispensing mechanism and lid
on the empty base.
3) Wave your hand over the sensor.
4) After the actuator cycles completely,
remove the dispensing mechanism and
lid, and reinstall the pump and pouch
into the dispenser base.
5) Reinstall the dispensing mechanism and
lid.
Tips & Troubleshooting
7
Prevent leaks:
Ensure that dome is pushed fully into pump housing.
Ensure that you hear a CLICK when attaching pump to
pouch.
Product not dispensing?
Make sure dome is primed properly.
Make sure lid is seated properly.
Activate the safety switch.
Can I change the portion on the Touchless UNI Dispenser?
No, it is preset at ¾ oz at the factory.
Can I plug the Touchless UNI Dispenser into a power strip?
Yes, each dispenser only draws 2 amps when in use. You can safely plug 7 dispensers
into a power strip on a single 15 amp plug and 10 dispensers into a 20 amp plug.
Why doesn’t the motor engage when I wave my hand over the sensor?
1) The sensor is designed to dispense when your hand is between 1" and 5" above the
sensor. If it's too close or too far away, the sensor might not recognize your
hand. Try moving your hand up and down on the sensor to see if it triggers.
2) Make sure that the power supply is plugged into a working outlet.

Asept International AB
Traktorvägen 17, SE-226 60
Lund, Sweden
+46 46 329 700
Asept International Inc.
900 Oakmont Ln, Suite 207,
Westmont IL 60559, USA
888-927-3785
8
Product Label and Cover
ASEPT General Warranty
Liability for defects
Should the products, as delivered, within one
(1) year from delivery be shown to be defective
due to defaults in material or manufacturing
(“Warranty Period”), the Supplier undertakes,
at its own option (i) to make a replacement
delivery, (ii) to repair or rework the products
claimed to be defective or (iii) to accept return
of such product and refund such proportion of
the purchase sum received as corresponds to
the returned products. The Supplier assumes
no liability for defects as regards to layout
and design of the products, unless expressly
stated in the Agreement.
The Customer shall without undue delay
notify the Supplier in writing of any defect
which appears. Such notice shall under no
circumstances be given later than two (2)
weeks after the expiry of the Warranty Period.
The Supplier is liable only for defect which
appear under the conditions of operation
provided for in the Agreement and under
11090 8/22
proper use of the product. The Supplier’s liability
does not cover defect which are caused by faulty
maintenance, incorrect erection or faulty repair
by the Customer, or by alterations carried out
without the Supplier’s consent in writing. Finally,
the Supplier’s liability does not cover normal
wear and tear or deterioration.
Except as expressly specied above, the Supplier
has no liability for defects in the products
whatsoever and are under no circumstances
responsible for any direct or indirect losses,
damages or costs incurred by the Customer,
including consequential damages.
General limitation of liability
Notwithstanding any other limitation of liability
mentioned in the Agreement including these
Terms and Conditions, the Supplier’s liability for
damages under the Agreement shall be limited
to the insurance compensation that can be
obtained in accordance with the Supplier’s each
valid liability insurance.
Consequential losses
There shall be no liability of either party towards
the other party for loss of production, loss of
prot, loss of use, loss of contract or for any other
consequential or indirect loss whatsoever.
Place product label in slot, making sure to
align sensor hole.
Attach the clear cover. Align tab and slot,
and slide into place.
Insert Cover Over Product
Label
This manual suits for next models
2
Table of contents
Other ASEPT Dispenser manuals