1
2
6
3
4
5
PAS005AP
1. cover
2. IR-prism (2 m)
3. main connector
DESCRIPTION
ENGLISH
SAFETY SENSOR FOR AUTOMATIC SLIDING
DOORS
4. IR-angle adjustment
5. push button for setup or DIP-setting confirmation
6. DIP-switch
User’s Guide for product version 0200 and higher
See product label for serial number
TECHNICAL SPECIFICATIONS
Presence
Typical response time: <256 ms
Active infrared with background analysis
Spot diameter: 0.1 m (typ)
Number of spots: 24
Number of curtains: 2
From -4 ° to +4 ° (adjustable)
Solid-state-relay
(free of potential, free of polarity)
Max. contact current: 100 mA
Max. contact voltage: 42 V AC/DC
0.3 s to 1 s (not adjustable)
Typical: < 5 ms
12 V - 30 V DC -5%/+10% (to be operated from SELV compatible power supplies only)
< 1.6 W
1.8 m to 3 m
< 1 V : Log. L; > 10 V: Log. H (max. 30 V)
-25 °C to +55 °C
IP54
< 70 dB
20 years
EN 16005; EN 12978; EN IEC 62061 SIL2; EN 61496-1 ESPE Type 2; EN ISO 13849-1
Pl «c» CAT.2 (under the condition that the door control system monitors the sensor at least once per door cycle)
Supply voltage:
Power consumption:
Mounting height:
Sensitivity of the test input:
Temperature range:
Degree of protection:
Noise:
Expected lifetime:
Conformity:
Detection mode:
Technology:
Angle:
Output:
Hold time output signal:
Response time on test request:
Specifications are subject to changes without prior notice. All values measured in specific conditions.
RED
LED
1
2
0
1
2
12
0
1
2
33
3
0
1
2
12
0
1
2
33
3
«click»
1
1
H
W
H
W
2 m 1 m
max.
5 cm
max. 5 cm
+
-
+
-
1 m left 1 m right
12-30 V DC
MOUNTING & WIRING
INFRARED FIELD - SAFETY
GREEN
BROWN
YELLOW
WHITE
PINK
GREY
RED2
BLUE2
POWER SUPPLY
OPENING INPUT
SAFETY INPUT
TEST
OUTPUT
WIDTH
RED
LED
1Output status when sensor is operational
2For compliance with EN 16005, connection
to door controller test output is required.
The door control unit and the door cover profile must be correctly earthed.
SENSOR
HW
2.20 m 2.30 m
2.50 m 2.55 m
3.00 m 2.80 m
HW
2.20 m 1.20 m
2.50 m 1.40 m
3.00 m 1.60 m
@ 2.2 m:
Depth of curtain : 8-10 cm
Depth of safety field: 25 cm*
RELAY R1
RELAY R2
Check position of IR-curtains with
Spotfinder and adjust if necessary.
DOOR
Detection field width indicated
according to conditions defined
in EN 16005 and including
dimension of test body CA.
ANGLE
CLOSERCLOSER
AWAYAWAY
ORANGE
* in standard presetting
The size of the detection field varies according to the mounting height of the sensor.
3
4
+
+
A
B
Launch an ASSISTED SETUP to verify wiring, position of the
curtains and correct functioning of the sensor.
SETTINGS (by DIP-switch)
QUICK SETUP ASSISTED SETUP
SETUP
OPEN+CLOSE RED-GREEN OFF
RED-GREEN OFF
Step outside of the detection field before launching a setup.
LONG (> 3s)
LONG
SHORT
standard
critical
environment
standard
extreme 1
1Enhanced IR-immunity which excludes EN 16005-conformity of the door system.
LONG (> 3s)
critical environment: enhanced immunity for critical environments (rain, snow, lamps...). Only 1 IR-curtain activated.
standard: standard environments (factory setting)
NC
NO
The yellow and white wires have to be connected to launch an
assisted setup.
After changing a DIP-switch, the orange LED flashes.
A LONG push on the push button confirms the setting.
Always launch a setup after changes of the DIP-settings.
- Test the good functioning of the installation before leaving the premises.
- The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system
in compliance with applicable national and international regulations and standards on door safety and if applicable, the machinery
directive 2006/42/EC.
- The device cannot be used for purposes other than its intended use. All other uses cannot be guaranteed by the manufacturer
of the sensor.
- The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor.
- Only trained and qualified personnel may install and setup the sensor.
- The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel.
- Avoid touching any electronic and optical components, avoid vibrations, do not cover the sensor and avoid proximity to
neon lamps or moving objects.
- It is recommended to clean the optical parts at least once a year or more often if required due to environmental conditions.
SAFETY INSTRUCTIONS
PRESETTINGS ENVIRONMENT R2 CONFIGURATIONFREQUENCY
ORANGE OFF
2
1
4
5
1
2
1
1
2
1
2
1
2
1
2
1
1
2
1
2
1
1
1
1
2
ASSA ABLOY Entrance Systems AB - Lodjursgatan 10 - SE-261 44 Landskrona - Sweden - www.ditecautomations.com
©ASSA ABLOY Entrance Systems AB I Original instructions | 47.0468 / V1 - 05.21-D0
LED-SIGNALS
This product should be disposed of separately from unsorted municipal waste
PLEASE KEEP FOR FURTHER USE - DESIGNED FOR COLOUR PRINTING
The ORANGE LED
flashes 1 x.
The ORANGE LED
flashes 2 x.
The ORANGE LED
flashes 4 x.
The ORANGE LED
flashes 5 x.
The ORANGE LED
is on.
The RED LED flashes
quickly after an
assisted setup.
The RED LED
lights up
sporadically.
The LED is off.
The reaction of
the door does not
correspond to the
LED-signal.
The ORANGE LED
flashes quickly.
The sensor signals
an internal fault.
Irregularities in the
power supply
The sensor receives
not enough IR-energy.
The sensor receives
too much IR-energy.
The sensor encounters
a memory problem.
The sensor vibrates.
The sensor sees the door
during the assisted setup.
The sensor sees the door.
The sensor is disturbed by
lamps or another sensor.
The sensor is disturbed
by the rain.
A DIP-switch was changed
without confirmation.
Check power supply.
Check wiring.
Use the 1 m prism if possible (accessory).
Check the angle of the IR-curtains.
Cut and restore power supply.
If orange LED lights up again, replace sensor.
Check the angle of the IR-curtains.
Launch a new assisted setup.
Attention: Do not stand in the detection field!
Change the output configuration (DIP 4).
Use a low energy prism if possible (accessory).
Check the angle of the IR-curtains.
Check if the sensor is fastened firmly.
Check position of prism and cover.
Choose a different frequency (DIP 2).
Choose the critical environment presetting (DIP 1).
Launch an assisted setup and adjust the IR angle.
Cut and restore power supply.
If orange LED flashes again, replace sensor.
Check connections to test output.
If your door controller is not able to test the sensor,
connect the red and blue cable to the power supply.*
Confirm the DIP-settings by a long push on the
push button.
*excludes EN 16005-conformity of the door system
ASSA ABLOY Entrance Systems AB, Lodjursgatan 10, SE-261 44 Landskrona, Sweden, hereby declares that the PAS005AP
is in conformity with the basic requirements and the other relevant provisions of the directives 2014/30/EU, 2011/65/EU and 2006/42/EC.
Notified Body for EC-type inspection: 0044 - TÜV NORD CERT GmbH, Langemarckstr. 20, D-45141 Essen
EC-type examination certificate number: 44 205 13 089601-001
Landskrona, January 2021 Matteo Fino, authorized representative and responsible for technical documentation
The complete declaration of conformity is available on our website.

Other Assa Abloy Security Sensor manuals

Assa Abloy Yale EF-PIR User manual

Assa Abloy

Assa Abloy Yale EF-PIR User manual

Assa Abloy Yale SR-PIR User manual

Assa Abloy

Assa Abloy Yale SR-PIR User manual

Assa Abloy Yale SR-BX User manual

Assa Abloy

Assa Abloy Yale SR-BX User manual

Assa Abloy Yale SR-A100-0EIR User manual

Assa Abloy

Assa Abloy Yale SR-A100-0EIR User manual

Assa Abloy Yale SR-PC User manual

Assa Abloy

Assa Abloy Yale SR-PC User manual

Assa Abloy TRAKA32 User manual

Assa Abloy

Assa Abloy TRAKA32 User manual

Popular Security Sensor manuals by other brands

Agilent Technologies 8355 Sulfur user manual

Agilent Technologies

Agilent Technologies 8355 Sulfur user manual

EUCHNER MGB-L**B-PN series operating instructions

EUCHNER

EUCHNER MGB-L**B-PN series operating instructions

Jaycar QC-3506 user manual

Jaycar

Jaycar QC-3506 user manual

LEGRAND 5 742 52 manual

LEGRAND

LEGRAND 5 742 52 manual

EVERSPRING SE812 user manual

EVERSPRING

EVERSPRING SE812 user manual

Vigilate VIGMS user manual

Vigilate

Vigilate VIGMS user manual

ADEMCO 990 installation manual

ADEMCO

ADEMCO 990 installation manual

elobau N3 Series manual

elobau

elobau N3 Series manual

Tynetec ZXT424 manual

Tynetec

Tynetec ZXT424 manual

Roger Technology R90 Series INSTRUCTIONS AND RECOMMENDATIONS FOR THE INSTALLER

Roger Technology

Roger Technology R90 Series INSTRUCTIONS AND RECOMMENDATIONS FOR THE INSTALLER

SulfiLogger X1-BCDE-F installation manual

SulfiLogger

SulfiLogger X1-BCDE-F installation manual

ABS Safety ABS-Lock OnTop installation manual

ABS Safety

ABS Safety ABS-Lock OnTop installation manual

Inficon Contura S400 Translation of the original operating instructions

Inficon

Inficon Contura S400 Translation of the original operating instructions

IDEC SE4D Series Quick instruction manual

IDEC

IDEC SE4D Series Quick instruction manual

Bosch D-tect 150 Original instructions

Bosch

Bosch D-tect 150 Original instructions

Summit Treestands Summit Instruction booklet

Summit Treestands

Summit Treestands Summit Instruction booklet

Sonoff SNZB-04P user manual

Sonoff

Sonoff SNZB-04P user manual

Challenger SL04B instructions

Challenger

Challenger SL04B instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.