ASTi Telestra Instruction manual

ASTi
Telestra USB Device
Connections Matrix
Document: ASSY-01-UMCX-IN-1
Advanced Simulation Technology inc. 500A Huntmar Park Drive, Herndon, Virginia, 20170 USA
Revision D.3 (January 2008)


Product Name: Telestra
ASTi Telestra USB Device Connections Matrix
© Copyright 2008 ASTi
Restricted Rights: Use, duplication, or disclosure by the Government is subject to restrictions as set forth in sub-
paragraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013.
This material may be reproduced by or for the U.S. Government pursuant to the copyright license under the
clause at DFARS 252.227-7013 (1994).
ASTi
500A Huntmar Park Drive
Herndon, VA 20170


i
Table of Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Hardware Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
USB Connector Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Power-On Ordering Requirements and Lost USB Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Telestra Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Telestra-to-Axis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Telestra-to-6-Channel Iris . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Telestra-to-Prism . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Telestra-to-Spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Telestra-to-Iris . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Telestra-to-1U Local Iris . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Telestra-to-1U Extended Iris . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Telestra-to-4-Channel Local Iris . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Telestra-to-4-Channel Extended Iris . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Axis Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Axis-to-Axis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Axis-to-Prism . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Axis-to-Spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Axis-to-Iris . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Axis-to-1U Extended and Local Iris . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Axis-to-4-Channel Extended and Local Iris . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Axis-to-6-Channel Iris . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Prism Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Prism-to-Axis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Prism-to-Prism . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Prism-to-Spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2-Channel Prism-to-Iris . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Prism-to-1U Extended Iris . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Prism-to-1U Local Iris . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Prism-to-4-Channel Extended Iris . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Prism-to-4-Channel Local Iris . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Prism-to-6-Channel Iris . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4-Channel Prism-to-Iris . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Spectrum Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Spectrum-to-Axis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Spectrum-to-Prism . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Spectrum-to-Spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Spectrum-to-Iris . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Spectrum-to-1U Extended and Local Iris . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Spectrum-to-4-Channel Extended and Local Iris . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Spectrum-to-6-Channel Iris . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

ii
Iris Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Iris-to-Axis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Iris-to-Prism . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Iris-to-Spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Iris-to-Iris . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Iris-to-1U Extended and Local Iris . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Iris-to-4-Channel Extended and Local Iris . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Iris-to-6-Channel Iris . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
USB Connections Overview Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Telestra USB Connections Matrix (Ver. 1, Rev. D.3)
Copyright © 2008 Advanced Simulation Technology inc. 1
Introduction
ASTi's Telestra product line includes a variety of USB-based digital audio and input/output (I/O)
distribution equipment. USB connections originate at the Telestra processing platform, and even-
tually terminate at one or more Iris audio interface modules. The installation and connection of
intermediate devices will vary depending on the required distribution of these Iris devices.
This document addresses which types of connections are supported (and which are not). Where
connections
are
supported, maximum cable lengths and connector types are highlighted.
For the sake of clarity, this document uses the word “upstream” in reference to devices that are
closer to the Telestra system in relation to other “downstream” devices.
ASTi’s USB interface is based on the industry standard USB 2.0, but has been optimized for use
with this product line.
WARNING: Do not connect commercially-available, standard USB devices to the USB ports on
the Iris, Axis, Prism or Spectrum devices. This may cause damage to these devices.
Hardware Overview
There are eight (8) different devices that can be used in any Telestra installation:
1.
Telestra
: The processing platform itself
See “Telestra v3.0 User Guide” (DOC-01-TELS-UG-3) for full details.
2.
Iris
: The audio interface module where headsets and other I/O devices are attached.
See “Iris Audio Interface Module Technical & User Guide” (ASSY-01-UMAU-UG-1) for
full details.
3.
Axis
: The local USB distribution module
See “Axis Local Distribution Module Technical & User Guide” (ASSY-01-UMLD-UG-1)
for full details.
4.
Prism
: The USB extender module
5.
Spectrum
: The remote USB distribution module
See “Prism & Spectrum Remote Distribution Modules Technical & User Guide”
(ASSY-01-UMRXRD-UG-1) for full details.
6.
1U Iris Extended and Local Options
: The 1U Extended Iris is a 1U enclosure containing
one (1) standard Iris devices and one (1) Spectrum remote distribution module. The 1U
Local Iris is a 1U enclosure containing one (1) Iris devices and one (1) Axis local distribu-
tion module.
See “Iris Audio Interface Module Technical & User Guide” Appendix A (ASSY-01-
UMAU-UG-1) for the full details.

Telestra USB Connections Matrix (Ver. 1, Rev. D.3)
2 Copyright © 2008 Advanced Simulation Technology inc.
7.
4-Channel Iris
: There are two 4-Channel Iris options. The 4-Channel Extended Iris is a
single 1U enclosure containing two (2) standard Iris devices and one (1) Spectrum remote
distribution module. The 4-Channel Local Iris is a single 1U enclosure containing two (2)
Iris devices and one (1) Axis local distribution module.
See “Iris Audio Interface Module Technical & User Guide” Appendix A (ASSY-01-
UMAU-UG-1) for the full details.
8.
6-Channel Iris
: The 6-Channel Iris is a single 1U enclosure containing three (3) standard
Iris devices and one (1) Axis local distribution module.
See “Iris Audio Interface Module Technical & User Guide” Appendix B (ASSY-01-
UMAU-UG-1) for the full details.

Telestra USB Connections Matrix (Ver. 1, Rev. D.3)
Copyright © 2008 Advanced Simulation Technology inc. 3
USB Connector Types
In the following diagrams, connectors marked with an “A” represent standard USB type A plugs.
Connectors marked with a “b” represent miniature USB type B plugs.
Cables Suggestion
ASTi highly suggests using professionally-made, high-quality Cat 5 and USB cables. Our tests
have shown that most errors are the result of improperly constructed or poor quality cables.
Ab
Receptacle
Connector
Shape
Standard
Type A
Miniature
Type B
not to
scale

Telestra USB Connections Matrix (Ver. 1, Rev. D.3)
4 Copyright © 2008 Advanced Simulation Technology inc.
Power-On Ordering Requirements and Lost USB Devices
The USB audio distribution architecture has specific requirements regarding the power on
sequencing of devices in order to achieve a working system. The Telestra processor system must
perform a discovery process in order to find all the devices that are connected, and hence this sys-
tem is started last in the sequence of elements. The discovery process runs as part of the system
framework boot process, or it is manually initiated from RMS, by clicking the “Hardware” tab,
and then the “Reset USB network” link. Prior to this all other elements of the USB sub-system
must be connected, and powered on.
Note
that the Prism/Spectrum extender architecture should
be powered on before or simultaneously with the Iris audio interface units.
If any element of the USB sub-system is powered off and then back on again without rebooting
the Telestra processor, or initiating a manual USB discovery, then the result will be that those
devices are “lost” to the system, and will no longer process audio. The most effective way to
check for this condition is to look at the RMS system, select the “Hardware” tab, and then the
“Layout” tab. Any Iris units that were connected at the time of system boot and have been subse-
quently powered off will show up with a red ‘X’ through the device. If profiling is turned on (see
Telestra 3 User Guide for details), then any device that is not active on the USB sub-system will
be reported with a red ‘X’. To recover from this situation, power on the required USB devices
(Prism devices first, Iris devices last), and then either reboot the Telestra, or initiate a manual USB
re-discovery using RMS. If using RMS, once the re-discovery process has completed, it will be
necessary to reload the model.

Telestra USB Connections Matrix (Ver. 1, Rev. D.3)
Copyright © 2008 Advanced Simulation Technology inc. 5
Telestra Connections
All USB devices require ASTi cable "CA-UA-UMB-X", where X stands for length, for
correct operation.
Telestra-to-Axis
This type of connection is supported.
Cable type: USB cable, standard A type connector to miniature B type connector
Maximum cable length: 3 feet
Telestra-to-6-Channel Iris
This type of connection is supported.
Cable type: USB cable, standard A type connector to miniature B type connector
Maximum cable length: 3 feet
Telestra-to-Prism
This type of connection is supported for both the 2-channel and 4-channel versions of the
Prism module.
Cable type: USB cable, standard A type connector to miniature B type connector
Maximum cable length: 3 feet
Telestra-to-Spectrum
This type of connection is not supported.
A
b
From Telestra (upstream) To Axis (downstream)
3 ft. max.
A
b
From Telestra (upstream) To 6-Channel Iris (downstream)
3 ft. max.
A
b
From Telestra (upstream) To 2ch or 4ch Prism (downstream)
3 ft. max.
From Telestra (upstream) To Spectrum (downstream)

Telestra USB Connections Matrix (Ver. 1, Rev. D.3)
6 Copyright © 2008 Advanced Simulation Technology inc.
Telestra-to-Iris
This type of connection is not supported.
Telestra-to-1U Local Iris
This type of connection is supported.
Cable type: USB cable, standard A type connector to miniature B type connector
Maximum cable length: 3 feet
Telestra-to-1U Extended Iris
This type of connection is not supported.
Telestra-to-4-Channel Local Iris
This type of connection is supported.
Cable type: USB cable, standard A type connector to miniature B type connector
Maximum cable length: 3 feet
Telestra-to-4-Channel Extended Iris
This type of connection is not supported.
From Telestra (upstream) To Iris (downstream)
A
b
From Telestra (upstream) To 1U Local Iris (downstream)
3 ft. max.
From Telestra (upstream) To 1U Extended Iris (downstream)
A
b
From Telestra (upstream) To 4-Channel Local Iris (downstream)
3 ft. max.
From Telestra (upstream) To 4-Channel Extended Iris (downstream)

Telestra USB Connections Matrix (Ver. 1, Rev. D.3)
Copyright © 2008 Advanced Simulation Technology inc. 7
Axis Connections
All USB devices require ASTi cable "CA-UA-UMB-X", where X stands for length, for
correct operation.
Axis-to-Axis
This type of connection is not supported.
Axis-to-Prism
This type of connection is not supported, regardless of the type of Prism device.
Axis-to-Spectrum
This type of connection is not supported.
Axis-to-Iris
This type of connection is supported.
Cable type: USB cable, standard A type connector to miniature B type connector
Maximum cable length: 15 feet
From Axis (upstream) To Axis (downstream)
From Axis (upstream) To 2ch or 4ch Prism (downstream)
From Axis (upstream) To Spectrum (downstream)
From Axis (upstream) To Iris (downstream)
A
b
15 ft. max.

Telestra USB Connections Matrix (Ver. 1, Rev. D.3)
8 Copyright © 2008 Advanced Simulation Technology inc.
Axis-to-1U Extended and Local Iris
This type of connection is not supported.
Axis-to-4-Channel Extended and Local Iris
This type of connection is not supported.
Axis-to-6-Channel Iris
This type of connection is not supported.
From Axis (upstream) To 1U Extended and Local Iris (downstream)
From Axis (upstream) To 4-Channel Extended and Local Iris (downstream)
From Axis (upstream) To 6-Channel Iris (downstream)

Telestra USB Connections Matrix (Ver. 1, Rev. D.3)
Copyright © 2008 Advanced Simulation Technology inc. 9
Prism Connections
All USB devices require ASTi cable "CA-UA-UMB-X", where X stands for length, for
correct operation.
Prism-to-Axis
This type of connection is not supported, regardless of the type of Prism device.
Prism-to-Prism
This type of connection is not supported, regardless of the types of Prism devices.
Prism-to-Spectrum
This type of connection is supported for both the 2-channel and 4-channel versions of the
Prism module.
Cable type: Category 5 or better, Unshielded Twisted Pair (UTP), RJ-45 connectors
Maximum cable length: 300 feet
2-Channel Prism-to-Iris
This type of connection is supported for
only the 2-channel version
of the Prism module.
Cable type: USB cable, standard A type connector to miniature B type connector
Maximum cable length: 6 feet
From 2ch or 4ch Prism (upstream) To Axis (downstream)
From 2ch or 4ch Prism (upstream) To 2ch or 4ch Prism (downstream)
From 2ch or 4ch Prism (upstream) To Spectrum (downstream)
300 ft. max.
From 2ch Prism (upstream) To Iris (downstream)
6 ft. max.
A
b

Telestra USB Connections Matrix (Ver. 1, Rev. D.3)
10 Copyright © 2008 Advanced Simulation Technology inc.
Prism-to-1U Extended Iris
This type of connection is supported for both the 2-channel and 4-channel versions of the
Prism module.
Cable type: Category 5 or better, Unshielded Twisted Pair (UTP), RJ-45 connectors
Maximum cable length: 300 feet
Prism-to-1U Local Iris
This type of connection is not supported, regardless of the types of Prism devices.
Prism-to-4-Channel Extended Iris
This type of connection is supported for both the 2-channel and 4-channel versions of the
Prism module.
Cable type: Category 5 or better, Unshielded Twisted Pair (UTP), RJ-45 connectors
Maximum cable length: 300 feet
Prism-to-4-Channel Local Iris
This type of connection is not supported, regardless of the types of Prism devices.
Prism-to-6-Channel Iris
This type of connection is not supported, regardless of the types of Prism devices.
From 2ch or 4ch Prism (upstream) To 1U Extended Iris (downstream)
300 ft. max.
From 2ch Prism (upstream) To 1U Local Iris (downstream)
From 2ch or 4ch Prism (upstream) To 4-Channel Extended Iris (downstream)
300 ft. max.
From 2ch Prism (upstream) To 4-Channel Local Iris (downstream)
From 2ch Prism (upstream) To 6-Channel Iris (downstream)

Telestra USB Connections Matrix (Ver. 1, Rev. D.3)
Copyright © 2008 Advanced Simulation Technology inc. 11
4-Channel Prism-to-Iris
This type of connection is not supported using the 4-Channel Prism device.
From 4ch Prism (upstream) To Iris (downstream)

Telestra USB Connections Matrix (Ver. 1, Rev. D.3)
12 Copyright © 2008 Advanced Simulation Technology inc.
Spectrum Connections
All USB devices require ASTi cable "CA-UA-UMB-X", where X stands for length, for
correct operation.
Note: Only two Iris devices can connect to each Spectrum.
Spectrum-to-Axis
This type of connection is not supported.
Spectrum-to-Prism
This type of connection is not supported, regardless of the type of Prism device.
Spectrum-to-Spectrum
This type of connection is not supported.
Spectrum-to-Iris
This type of connection is supported.
Cable type: USB cable, standard A type connector to miniature B type connector
Maximum cable length: 6 feet
Note
: Due to the nature of the USB extension, the Iris must be powered on after the Prism.
From Spectrum (upstream) To Axis (downstream)
From Spectrum (upstream) To 2ch or 4ch Prism (downstream)
From Spectrum (upstream) To Spectrum (downstream)
From Spectrum (upstream) To Iris (downstream)
A
b
6 ft. max.

Telestra USB Connections Matrix (Ver. 1, Rev. D.3)
Copyright © 2008 Advanced Simulation Technology inc. 13
Spectrum-to-1U Extended and Local Iris
This type of connection is not supported.
Spectrum-to-4-Channel Extended and Local Iris
This type of connection is not supported.
Spectrum-to-6-Channel Iris
This type of connection is not supported.
From Spectrum (upstream) To 1U Extended and Local Iris (downstream)
From Spectrum (upstream) To 4-Channel Extended and Local Iris (downstream)
From Spectrum (upstream) To 6-Channel Irises (downstream)

Telestra USB Connections Matrix (Ver. 1, Rev. D.3)
14 Copyright © 2008 Advanced Simulation Technology inc.
Iris Connections
All USB devices require ASTi cable "CA-UA-UMB-X", where X stands for length, for
correct operation.
Iris-to-Axis
This type of connection is not supported.
Iris-to-Prism
This type of connection is not supported.
Iris-to-Spectrum
This type of connection is not supported.
Iris-to-Iris
In some configurations, it is possible to daisy-chain one Iris device off another, upstream Iris mod-
ule. This can only be done when the upstream Iris device is connected directly to an Axis local
distribution module.
This type of connection is supported.
Cable type: USB cable, standard A type connector to miniature B type connector
Maximum cable length: 6 feet
If the upstream Iris device is connected to a Spectrum unit, daisy-chaining is not supported.
This type of connection is not supported.
From Iris (upstream) To Axis (downstream)
From Iris (upstream) To 2ch or 4ch Prism (downstream)
From Iris (upstream) To Spectrum (downstream)
From Iris off Axis (upstream) To Iris (downstream)
A
b
6 ft. max.
From Iris off Spectrum (upstream) To Iris (downstream)
Other manuals for Telestra
4
Table of contents