16 Speed range 0~99999 6000 22H 0x03 , 0x10 Maximum rotational speed measuring range.
17 Speed to zero 0~17999
Factory
commissio
ning
24H 0x03 , 0x10 The transmission and output point when the
speed value is 0.
18 The speed
changes to full 0~17999
Factory
commissio
ning
26H 0x03 , 0x10 Output point of the transmission when the
speed value is the maximum range value.
19 Communication
mode 0~1 0 28H 0x03 , 0x10
The communication mode is 1, which means
that the output mode is modbus_RTU, and the
communication mode is 0, which means that
the output mode is ASCII active upload
20 parity check bit 0~2 0 2AH 0x03 , 0x10 0 Is no check bit, 1 odd, 2 parity
21 data bit 0~1 0 2CH 0x03 , 0x10 0 For 8 data bits and 1 means 9 data bits
22 stop bit 0~1 1 2EH 0x03 , 0x10 RS485 communication stop, 1 indicates stop
1 and 0 indicates stop 2.
23 mailing address 0~128 1 30H 0x03 , 0x10 The Modbus_RTU communicates with the
current meter address.
24 Baud rate 0~4 0 32H 0x03 , 0x10
RS485 Communications Baud rate.0: Turn off
the communication, 1:4800. 2:9600. 3:19200.
4:38400
25 High and low in
the front 0~1 0 34H 0x03 , 0x10 0 High means the top, 1 means the top.
zero clearing 36H 0x05 , 0x10 Establish the current torque zero,
communication write 00
factory data
reset 38H 0x05 , 0x10 Return to the factory parameters,
communication write 00
Real-time
torque 00H 0x03 Real-time torque value.
Real-time speed 02H 0x03 Real-time speed value.
Note: (The parameter address offset value is 4000, and a multiple of 4000 increase can also read the current value
directly.)
8. Basic operation instructions:
Modify parameters:Long press for a second to enter the menu, press again, you can switch back and forth in several
parameter interfaces. Press the key can switch the modification bit of the current parameter, and the long press can jump
around the parameters in the current display interface. Press key to modify the current bit of the current parameter. After
the modification is completed, you can directly jump back with the key to the main interface, and automatically save the
modified parameters.
Displays the interface switch:There are three display interfaces, the main display interface shows the current torque
speed, the second display interface shows the torque frequency, the third display interface shows the speed frequency, and
the three display interface can switch around after pressing the key in the main interface.
Modify numerical filtering:When customers need more stable torque values or react to faster torque values, they can
turn the digital filtering up or down. The larger the digital filtering, the more lagging and stable the torque value changes.
When the digital filter value is changed to 1, the torque value is the fastest reaction speed, at 100 times per second.
Curves can be collected in real time using MODBUS RTU or computer protocol.
Torque value zero:Press the long key at the main interface to establish the zero point.
factory data reset:This table power time is pressed on the key to restore the factory setting.
、Newsletter profile
The instrument data is 32 bits, with the high level before and the low level after, please read the multiple of 2. This instrument is equipped with
RS485 interface, which can use the company autonomous protocol and modbus RTU protocol. The communication mode set to 0 indicates the
company autonomous protocol, which is applicable to connect the company upper computer. Communication mode set to 1 indicates using the
modbus RTU protocol. Changing the port rate needs to take effect after a restart.
Communication adopts the instrument active upload protocol:The protocol has six bytes, D0~D5, D0D1 two bytes for torque, D2D3 two bytes
for rotational speed, and D4D5 for the CRC16 check bit of the first four bytes of data. The highest position of D2 indicates positive or negative
torque value, and 1 indicates negative torque value.0 Is a positive number. Depending on the Baud rate, the protocol uploads data at different
speeds, 9600 —— 50 times, 19200 —— 19200, and 200 times 38400 —— per second.
Communication uses the MODBUS-RTU protocol:Address domain + functional domain + data domain + check domain
functional domain :
Read the data register values
Modify the amount of switch
Quickly modify the switch
quantity value