manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ATP Electronics
  6. •
  7. Measuring Instrument
  8. •
  9. ATP Electronics AMT-903 User manual

ATP Electronics AMT-903 User manual

Other ATP Electronics Measuring Instrument manuals

ATP Electronics AVM-81AM User manual

ATP Electronics

ATP Electronics AVM-81AM User manual

ATP Electronics MT-912 User manual

ATP Electronics

ATP Electronics MT-912 User manual

ATP Electronics MT-912 User manual

ATP Electronics

ATP Electronics MT-912 User manual

ATP Electronics ET-955 User manual

ATP Electronics

ATP Electronics ET-955 User manual

ATP Electronics LBY-420 User manual

ATP Electronics

ATP Electronics LBY-420 User manual

ATP Electronics MT-905C User manual

ATP Electronics

ATP Electronics MT-905C User manual

ATP Electronics ET-931 User manual

ATP Electronics

ATP Electronics ET-931 User manual

ATP Electronics AET-931 User manual

ATP Electronics

ATP Electronics AET-931 User manual

ATP Electronics LX-1301 User manual

ATP Electronics

ATP Electronics LX-1301 User manual

ATP Electronics ET-933 User manual

ATP Electronics

ATP Electronics ET-933 User manual

ATP Electronics MT-915 User manual

ATP Electronics

ATP Electronics MT-915 User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

User Manual
Mini Humidity & Temperature Meter
Please read this user manual thoroughly before using
the unit and keep it for your future reference
1. Safety
Read the following safety information carefully before attempting to operate the meter.
Use the meter only as specified in this manual; otherwise, the warranty may be invalidated.
Environment conditions:
Altitude up to 2000 meters
RH≤90%(Non-Condensation)
Operating Temperature: -20~60℃
Maintenance
Repairs or servicing should only be performed byATP Instrumentation Ltd.
Cleaning: Wipe the unit with a dry soft cloth. Do not use abrasives or solvents on this instrument.
Safety Symbol
Comply with EMC
2. Introduction
The Humidity & Temperature Meter has a high accuracy Humidity & Temperature sensor, providing high
accuracy, fast response and stable readings.
3. Application
This meter is ideal for measurement of temperature and humidity in environmental applications, and is ideally
suited for taking measurements in an air stream.
4. Specifications
Humidity
Measuring
Range Accuracy Resolution
0%~100%RH
20%~40%RH : ±3.0%
0.1%RH
40%~60%RH: ±2.5%
60%~80%RH: ±3.0%
0%~20%RH
80%~100%RH: ±3.5%
Temperature -30
℃
~70
℃
-22
℉
~158
℉
-30
℃
~-10
℃
(-22
℉
~14
℉
):
±1.0
℃
(±1.8
℉
)0.1℃
-10
℃
~70
℃
(14
℉
~158
℉
):
±0.5
℃
(±0.9
℉
)
Response Time 1 second
Sampling Rate 2 times per second
Working Temp. -30
℃
to 60
℃
Power Resource 9V battery
Dimension(L*W*H) 165 x 55 x 38mm
Weight 88g
5. Meter Description
1. Temperature & Humidity sensor
2. LCD display
3. Power ON/OFF button
4. MAX/MIN button
5. Tripod nut
6. Battery cover
6. LCD Display Description
1. Low battery indication
2. MAX/MIN icon
3. Humidity icon
4. Humidity reading
5. ℃/℉temperature icon
6. Temperature reading
7. Auto power off icon
8. Hold icon
7. Operation Instruction
(1) Open battery cover and install a 9-volt battery in the battery compartment.
(2) Power ON:Turn the meter on by pressing " " button for 1 second until the LCD is lit, then release
the button.
(3) Power OFF:Turn the meter off by pressing and holding " " button for approx. 3 seconds until the
LCD is switched off, then release the button.
(4) When the low battery icon " " appears, replace the meter's battery.
(5) Auto power off icon, the meter will automatically turn off after approx. 15 minutes of inactivity.
(6) LCD Backlight: After turning the meter on, momentarily press the " " button, the backlight will
come on; it will automatically turn off after approx. 30 seconds of inactivity.
(7) Hold & MAX/MIN Function
HOLD: After turning the meter on, press " " button. The "HOLD" icon will appear on the LCD,
which indicates the data is frozen. To release the held reading, press the button again.
MAX/MIN: Press and hold " " button for at least 3 seconds until "MAX" icon appears on the
LCD to view the MAX reading since power on; press the button again, the "MIN" icon appears on the
LCD to view the MIN reading since power on. To exit the MAX/MIN mode, press and hold the button
" " for 3 seconds.
(8) ℃/℉temperature units
In the OFF mode, press and hold the " " button, then power the meter on, after the LCD
displays, release the button, the temperature units ℃/℉will alternate.
(9) Calibration
The recommended calibration period is one year.
8. Notes
①This meter has already been calibrated before delivery.
②Repairs or servicing should only be performed byATP Instrumentation Ltd.
③Remove the battery when the meter is to be stored for long periods of time to avoid battery leakage.
9. Accessories
①User manual
②9V battery
ATP Instrumentation Ltd
Tournament Way
Ivanhoe Industrial Estate
Ashby-de-la-Zouch
Leicestershire
LE65 2UU
Sales: 01530 566 800 sales@atp-instruments.co.uk
Repair and Calibration: 01530 566 804 technical@atp-instruments.co.uk
www.atp-instrumentation.co.uk