AMP203 - User manual 015
Settings
Settings >> Device
By clicking the settings button in the top right corner on the devices page the device settings can be changed. The
settings for the AMP203 are divided into the following categories: Device, Inputs, Power, Network, Authentication.
Device/Zone name
The device name can be congured here. The device name can be any kind of freely selectable name. It is also the
name which is visible in the Dante controller.
TouchLink™ zone
A TouchLink™ zone number can be assigned here. Touchlink™ is an unique system whereby multiple ampliers within
one zone can be linked with each other, so they react to user as one zone.
TouchLink™ can be used to create virtual zones by linking multiple devices with each other. A typical application example
is a large area where multiple AMP203’s (or other TouchLink™ compatible devices) are installed in one large open space.
When they are virtually linked, all devices with the same TouchLink™ assigned number will follow each others’ settings
(such as volume, input, muting, ... ).
It means, if they are all installed throughout the same area, they all will be simultaneously operated by one single control
(e.g. volume fader) from the AUDAC Touch™ 2 application. Additionally, a wall panel which is physically connected to one
of the linked devices will automatically control all the linked devices.
A number shall be assigned as a TouchLink™ zone ID (e.g. 1, 2, 3, ... ) and all devices with the identical TouchLink™ zone
ID will virtually work as one zone.
Address
Here the device’s address can be set. This address is needed to communicate with the right device if commands will be
sent over a serial or UDP connection.
Setup wall panel
This resets the wall panel’s zone settings information, when an optional wall panel is being used. It is recommended when
experiencing any trouble with a wall panel, or when the wall panel has been used in another type of setup before. It resets
the wall panel settings to zone 1, making sure it can communicate with the AMP203.
Click on one of the devices in the list to open the device’s page. The rst time a device is opened a password will be
prompted. In the case of the AMP203, the factory default administrator password is ‘AMP203’. After entering the correct
password the device page will be shown with all available controls. The channels shown in the input selection list are
corresponding with the linked inputs through the Dante controller, while the volume slider allows adjusting the overall
output volume of the amplier.