Aura JGSTATW2W User manual

speedfitUFH.co.uk
For models:
JGSTATW2W
JGSTATW2B
JGSTATW1W
JGSTATW1B
Quick Set-up Guide
Wireless Thermostats
230v and Battery Operated

1 x Quick Set-up Guide JGSTATW2
4x AAA Batteries
JGSTATW1Fixing screws
Box cont nts:
Cont nts
Quick S t-up Guid :
• Box contents
• Introduction
• Product compliance
• Terminal connections
• Coordinator set-up
• JGBR set-up
• Identifying the Wiring Centre
• PRT quick set-up
• HWT quick set-up
Icons us d in this guid :
Safety
Important info
For latest PDF Q ick Set- p G ide and
f ll Instr ction Man al please go to
speedfitUFH.co. k
speedfitUFH.co.uk
For models:
JGSTATW2W
JGSTATW2B
JGSTATW1W
JGSTATW1B
Quick Set-up Guide
Wireless Thermostats
230v and Battery Operated
03
speedfitUFH.co.uk

04
JGSTATW1/W2 Quick Set-up Guide
Introduction. Thank you for purchasing
one of our Speedfit Aura Wireless
Thermostat models. It must be used with
the JGC Wireless Coordinator. The
Wireless Coordinator allows communication
with other devices in the Aura Wireless
system range including wiring centre,
Wireless boiler receiver and Wireless TRV.
Product Complianc . These
products are CE compliant and
meets the following European
Directives:
RoHS2: 2011/65/EU
RED: 2014/30/EU
Declaration of conformity available
at saluslegal.com
Saf ty Information. Use in
accordance with the regulations.
The JG Aura JGSTATW1/W2 is
to be used for room control of
heating and hot water systems
inside buildings.
JGWCW
JGTRV
JGSTATW1/W2
JGC
Product complianc & saf ty information
We hope yo enjoy
this prod ct...
JGBR

Product complianc & saf ty information
Em rg ncy. Switch off the
voltage to the individual
thermostat, wiring centre or
complete system.
Sourc s of dang r. The
thermostat must be disconnected
from mains supply before
removing the cover.
Install r param t r s ttings.
JG Aura wireless thermostats are
equipped with an Installer Parameter
section (see website). This must only
be entered by the installer or a
competent person. Changing these
parameters can have a serious
effect on your heating system.
230 AC
Warning. This product must be
fitted by a competent person.
Installation must comply with the
guidance, standards and
regulations applicable to the
location where the product is
installed. Failure to comply with the
requirements of the relevant
guidance, standards and
regulations could lead to
prosecution, injury or death.
These instructions are applicable to the
Aura models stated on the front cover of
this Instruction Manual only.
Warning. Always isolate the AC
Mains supply before installing or
working on any components that
require 230v AC 50Hz supply.
05
speedfitUFH.co.uk

R ar of unit
Pow r T rminals 230v AC.
Used for supplying power to the
unit. 230v supply can be sourced
from the wiring centre or any
convenient 3amp fused supply.
Prob / Hot Wat r Cylind r
T rminals. Can be used for
external Air or Floor probe when
configured as thermostat. Can
also be used for Cylinder
thermostat connection when
configured as a Timer.
Understanding your terminal connections
T rminal conn ctions
(JGSTATW2) - 230v pow r d
2
1
1
2
06
JGSTATW1/W2 Quick Set-up Guide
230VACVS10BRF

07
speedfitUFH.co.uk
R ar of unit
S nsor T rminals.
Can be used for an external Air
or Floor sensor when configured
as thermostat. Can also be used
for Cylinder thermostat when
configured for HW.
Understanding your terminal connections
T rminal conn ctions (JGSTATW1)
1
1
S1 - S2

To commence system installation, press and hold the button for 5 seconds. The button
will start to flash red indicating that the Zigbee network is ready to accept JG Aura devices.
For full Coordinator instructions please see seperate literature or go on line to
speedfitUFH.co.uk
Coordinator s t-up
08
JGSTATW1/W2 Quick Set-up Guide

After setting up, the Coordinator will assign the
Wiring Centre a number. This is because more
than 1 Wiring Centre may be used on a project.
Pressing the network button will illuminate the
relevant number. The example shown is for
Wiring Centre 1. If 1 and 2 are lit it would be
Wiring Centre 2.
The JGBR default setting is RX1 (Wireless Boiler Receiver). In this
mode, the JGBR will switch on the boiler in response to a call for heat.
To set as a wireless receiver, switch to RX2. The wireless receiver will
be paired to just one chosen thermostat on the network. This
thermostat will switch the wireless receiver when there is a call for heat.
JGBR s t-up -
Wireless Boiler Receiver or Wireless Receiver
Id ntifying th Wiring C ntr
09
speedfitUFH.co.uk

Programmabl Room Th rmostat pair d with
Wir l ss Wiring C ntr
12
3
Start up screen as shown.
Press C NFIRM
Prior to pairing refer to Coordinator start up on page 8.
Press C NFIRM
4
No action required.
icon flashing to request the number of the
Wiring Centre you wish to pair with (see Identifying
Wiring Centre - page 9). Use and to select
the required number. Press C NFIRM
10
JGSTATW1/W2 Quick Set-up Guide

56
7
requesting group number. No action
needed in this instance. Press C NFIRM
Zone number flashing. Using the and to
set the wiring centre zone you want the thermostat
to control. Press C NFIRM
Thermostat returns to home screen and the pairing is finished.
T sting: Set thermostat to high temperature and wait for a call for
heat. Check that the thermostat is communicating with the correct
zone on the paired wiring centre.
11
speedfitUFH.co.uk

Programmabl Room Th rmostat
pair d with
Wir l ss TRV
12
3
From start up screen press .
Screen will scroll to .
No action required.
4
Press C NFIRM
Press C NFIRM
Prior to pairing refer to Coordinator start up on page 8.
2
12
JGSTATW1/W2 Quick Set-up Guide

5
7
6
8
Thermostat returns to home screen.
T sting: Set to
call for heat. Check TRV’s are opening and Boiler
Receiver is receiving the signal. Turn down the
thermostat and check TRV’s shut and boiler receiver
turns off.
Next press arrow on thermostat to start pairing
process. Do not press Confirm as it will abort
the pairing process and user will have to start again.
Press Pairing Button on TRV(s) for 10
seconds until pairing light on the TRV starts
to flash. Maximum of 6 TRV’s can be paired
at the same time.
If thermostat only finds 1 to 5 TRV’s it will
continue to search until user presses Confirm
. If the maximum 6 TRV’s are found the
thermostat will automatically finish pairing
and return to the home screen.
13
speedfitUFH.co.uk

Programmabl Room Th rmostat
pair d with Wir l ss
Boil r R c iv r (RX1)
12
3
Start up screen as shown. Press and hold
bottom 3 buttons until next screen is
shown.
Press to scroll to .
4
Press C NFIRM
Press C NFIRM
2
Prior to pairing refer to Coordinator start up on page 8.
14
JGSTATW1/W2 Quick Set-up Guide
Note: See page
7 for setting of
JGBR to RX1.

56
7
No action required.
Thermostat returns to home screen. T sting: Set thermostat to high
temperature and wait for a call for heat. Check the Wireless Boiler
Receiver is receiving the signal and switching on and off.
Press C NFIRM
15
speedfitUFH.co.uk

4
Press C NFIRM
Programmabl Room Th rmostat
pair d with Wir l ss
R c iv r (RX2)
12
3
Press to scroll to .
Press C NFIRM
Prior to pairing refer to Coordinator start up on page 8.
Start up screen as shown. Press and hold
bottom 3 buttons until next screen is
shown.
2
16
JGSTATW1/W2 Quick Set-up Guide
Note: See page
7 for setting of
JGBR to RX2.

56
No action required.
7
Thermostat returns to home screen. T sting: Set thermostat to high
temperature and wait for a call for heat. Check the Receiver is receiving
the signal and switching on and off. If there is also a boiler receiver fitted
to the network check that this is responding.
Press C NFIRM
17
speedfitUFH.co.uk

Hot Wat r Tim r pair d with Wiring C ntr
Press to scroll to Hot Water Timer
screen
12
3
Press C NFIRM
4
Press C NFIRM
Start up screen as shown. Hold bottom
3 buttons to scroll to screen .
Prior to pairing refer to Coordinator start up on page 8.
2
18
JGSTATW1/W2 Quick Set-up Guide

56
78
Hot Water Timer displays home screen
.
T sting: Set timer to [ N] and check that Hot
Water Timer LED is lit on wiring centre.
Note: Hot Water
Timer will
a tomatically
join Gro p 1.
No action needed.
Press C NFIRM
icon flashing to request the
number of the Wiring Centre to pair with
(see Identifying Wiring Centre - page 9).
Use and to select the required
number. Press C NFIRM
19
speedfitUFH.co.uk

John Guest Speedfit Limited
Horton Road, West Drayton, Middlesex UB7 8JL, England.
Tel: 01895 449233
Fax: 01895 420321
speedfitUFH.co.uk
Technical Help Desk: 01895 425333
,
The above namestyles are all trademarks of John Guest International Limited.
©John Guest International Limited 2016. All rights reserved.
Z2105/458/0716
and