INSTALLATION
1. When positioning your luminaire, please take note of the IP Rating
2. Beware of existing water pipes and electric cables when preparing the site.
3. Always switch off mains supply when installing or re-positioning your luminaire.
4. When dismantling your luminaire, take note of the orientation and position of key components.
5. Never install your luminaire in a dip in the ground or in an area of localised flooding. This is to avoid pooling of water over
the top of the glass.
6. These ground recessed luminaires are supplied with a mounting sleeve. When installing the mounting sleeve of the
luminaire into the ground, always prepare a minimum of 30cm of gravel under the sleeve housing to allow for drainage
7. Secure the mounting sleeve into position using concrete or cement. Ensure sleeve is not distorted by the concrete or
cement, it must remain round.
8. Use 3-core 0.75mm2rubber insulated cable (H05RN-F) for connection. Always allow sufficient slack in the supply cable to
allow removal of the luminaire from its mounting sleeve for maintenance.
9. The 240V mains input connections are in the base of the luminaire and is accessed by removing the 4 Allen bolts on the
base enclosure. Two cable glands are available in the base for loop in loop out wiring. If using only one entry gland, the
other gland must be sealed completely to stop water ingress.
10. Connect the mains supply into the terminal block as follows:
•LIVE – (Red or Brown) to terminal marked ‘L’
•NEUTRAL – (Black or Blue) to terminal marked ‘N’
•EARTH – (Green & Yellow) to terminal marked
11. Replace the base enclosure, ensure that the seal is intact and located correctly and the Allen bolts are fully tightened.
Ensure that the cable glands are tight.
12. To install the lamp.
•Remove the top bezel (4 Allen bolts).
•Remove the 1st Glass lens (4 cross head screws)
•Remove the 2nd Glass lens (use a screwdriver to gently raise the edge of the glass and lift out).
•Carefully insert the lamp take care not to touch the glass with bare hands.
13. Replace the inner and outer glass lenses - check all seals and glass are intact and seated correctly. When securing the
bezel back on top of the luminaire, tighten the first screw and then the opposite screw to distribute even pressure.
14. Turn on mains supply and test luminaire.
Environmental Protection (W.E.E.E.) – Aurora’s WEEE Reg.No. WEE/BG0130YX
Waste Electrical & Electronic Equipment Regulations (WEEE) requires that any of our products showing this marking (left)
must not be disposed of with other household or commercial waste. Aurora does not levy any WEEE disposal charges to its
customers for affected WEEE related products. To prevent possible harm to the environment or human health from
uncontrolled waste disposal, please separate any such product from other waste types and recycle it responsibly at your
local facilities. Check with your Local Authority, Recycling Centre or retailer for recycling advice. If, when you purchased any
Aurora product, your supplier included a WEEE disposal fee, you should then contact your supplier for advice on his
takeback of the product for the correct disposal.
GUARANTEE
This product is guaranteed in the UK for a period of 1 year from the date of purchase, unless otherwise stated in
current company literature. The guarantee is invalid in the case of improper use, installation, tampering, removal of the
Q.C. date label, installation in an improper working environment or installation not according to the current edition of
the I.E.E. Wiring Regulations (BS7671). Should this product fail during the guarantee period, it will be replaced free of
charge, subject to correct installation and return of the faulty unit. Aurora does not accept responsibility for any
installation costs associated with the replacement of this product. Your statutory rights are not affected. Aurora
reserves the right to alter specifications without prior notice.