Avalue Technology EPD-4200 User manual

Part No. E2017E400A0R
EPD-4200
42" E Ink Public Display with Glass by E Ink T1000 TCON
board
Quick Reference Guide
1st Ed –06 January 2022
Copyright Notice
Copyright 2022 Avalue Technology Inc., ALL RIGHTS RESERVED.

EPD-4200
2 EPD-4200 Quick Reference Guide
FCC Statement
THIS DEVICE COMPLIES WITH PART 15 FCC RULES. OPERATION IS
SUBJECT TO THE FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE.
(2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED INCLUDING
INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS
FOR A CLASS "B" DIGITAL DEVICE, PURSUANT TO PART 15 OF THE FCC RULES.
THESE LIMITS ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST
HARMFUL INTERFERENCE WHEN THE EQUIPMENT IS OPERATED IN A
COMMERCIAL ENVIRONMENT. THIS EQUIPMENT GENERATES, USES, AND CAN
RADIATE RADIO FREQUENCY ENERGY AND, IF NOT INSTATLLED AND USED IN
ACCORDANCE WITH THE INSTRUCTION MANUAL, MAY CAUSE HARMFUL
INTERFERENCE TO RADIO COMMUNICATIONS.
OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY TO CAUSE
HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO
CORRECT THE INTERFERENCE AT HIS OWN EXPENSE.
A Message to the Customer
Avalue Customer Services
Each and every Avalue’s product is built to the most exacting specifications to ensure
reliable performance in the harsh and demanding conditions typical of industrial
environments. Whether your new Avalue device is destined for the laboratory or the factory
floor, you can be assured that your product will provide the reliability and ease of operation
for which the name Avalue has come to be known.
Your satisfaction is our primary concern. Here is a guide to Avalue’s customer services. To
ensure you get the full benefit of our services, please follow the instructions below carefully.
Technical Support
We want you to get the maximum performance from your products. So if you run into
technical difficulties, we are here to help. For the most frequently asked questions, you can
easily find answers in your product documentation. These answers are normally a lot more
detailed than the ones we can give over the phone. So please consult the user’s manual
first.
To receive the latest version of the user’s manual; please visit our Web site at:
http://www.avalue.com.tw/

Quick Reference Guide
EPD-4200 Quick Reference Guide
3
Content
1. Getting Started ........................................................................................................4
1.1 Safety Precautions....................................................................................................4
1.2 Packing List...............................................................................................................4
1.3 System Specifications...............................................................................................5
1.4 System Overview......................................................................................................6
1.5 System Dimensions ..................................................................................................7
2. Hardware Configuration .........................................................................................8
3. T1000 test tool................................................................................................................9
3.1 Driver ......................................................................................................................10
3.1.1 Windows 7................................................................................................................................. 10
3.1.2 Windows 10............................................................................................................................... 15
3.2 Application ..............................................................................................................16
3.3 Installation...............................................................................................................20

EPD-4200
4 EPD-4200 Quick Reference Guide
1. Getting Started
1.1 Safety Precautions
Warning!
Always completely disconnect the power cord from your
chassis whenever you work with the hardware. Do not
make connections while the power is on. Sensitive
electronic components can be damaged by sudden power
surges. Only experienced electronics personnel should
open the PC chassis.
Caution!
Always ground yourself to remove any static charge before
touching the CPU card. Modern electronic devices are very
sensitive to static electric charges. As a safety precaution,
use a grounding wrist strap at all times. Place all electronic
components in a static-dissipative surface or static-shielded
bag when they are not in the chassis.
1.2 Packing List
1 x EPD-4200 42" Communication Board
1 x Power Adapter
1 x US Power cord
1 x Wall mounting bracket
1 x Wall locking bracket
1 x Pan head screws (D6.8, M4*10mm) with washer (D8.1)
4 x Thumb screws (M4*10L)
2 x Pan head screws (D6.85, M4*6mm)
.

Quick Reference Guide
EPD-4200 Quick Reference Guide
5
1.3 System Specifications
Component
Mother Board
T1000 T-con board
Power Supply
DC-12V
Adapter
12V/ 5A
Panel
LCD Panel
42” E Ink Display with 2160 x 2880 pixels (ED420TT3)
Touch Screen
N/A (Use protection glass)
External I/O
USB Port
1 x USB 1.1
Others
EPD thermal sensor is only available in left-up
Mechanical
Power Type
DC in +12V/5A
Power Connector
Type
Lockable DC Jack
Dimension
934mm x 704mm
Weight
11.4kgs (N.W) / 17.4kgs (G.W)
Color
Black
Fanless
Yes
Reliability
EMI Test
FCC Class B
Dust and Rain Test
Front Panel IP65
Vibration Test
5Grms, IEC 60068-2-64, Random, 10 ~ 500Hz, 1hr/axis
(Only for Z-axis)
Mechanical Shock
Test
50G, IEC 60068-2-27, Half Sine, 11ms
(Only for Z-axis)
Drop Test
Avalue Standard Test Criteria (Change to use ISTA-1A)
Operating
Temperature
EPD (ED420TT3): 0°C ~ 50°C
EPD-4200: 0°C ~ 50°C
Operating Humidity
40°C@95% relative humidity, non-condensing
Storage Temperature
-20 ~ 60°C (-4 ~ 140°F)
Note:
Specifications are subject to change without notice.

EPD-4200
6 EPD-4200 Quick Reference Guide
1.4 System Overview
Connectors
Label
Function
Note
USB1.1
USB1.1 connector
DC IN
DC Power-in connector

Quick Reference Guide
EPD-4200 Quick Reference Guide
7
1.5 System Dimensions
(Unit: mm)

Quick Reference Guide
EPD-4200 Quick Reference Guide
9
3. T1000 test tool

EPD-4200
10 EPD-4200 Quick Reference Guide
3.1 Driver
3.1.1 Windows 7
a. Connect the T1000 device to PC and find the USB Mass Storage Device in the
subtree of universal serial bus controllers in the device manager.

Quick Reference Guide
EPD-4200 Quick Reference Guide
11
b. Right click USB Mass Storage Device and click Properties to check device.
c. Change to Details page and select Property to Hardware Ids, the device connect
to PC is USB\VID_048D&PID_8957.

EPD-4200
12 EPD-4200 Quick Reference Guide
d. When find the device, change to Driver page and click Update Driver.
e. Select Browse my conputer for driver software.

Quick Reference Guide
EPD-4200 Quick Reference Guide
13
f. Browse the folder which contain the AvalueDriver_T1000.inf.
g. Click Install.

EPD-4200
14 EPD-4200 Quick Reference Guide
h. Finish.
i. Device manager will see Avalue Driver - T1000 in the subtree of system devices.

Quick Reference Guide
EPD-4200 Quick Reference Guide
15
3.1.2 Windows 10
a. After connect the T1000 device to PC, Right click AvalueDriver_T1000.inf to install
driver.
b. Device manager will see Avalue Driver - T1000 in the subtree of system devices.

EPD-4200
16 EPD-4200 Quick Reference Guide
3.2 Application
a. Connect the T1000 device to PC before click Init.
b. This application will hide in the notification area if click upper right corner Xto close
application when initial is success.

Quick Reference Guide
EPD-4200 Quick Reference Guide
17
c. Right click the Avalue icon will show the option menu.
Click Show or double click the Avalue icon to show the application.
Click Start (when the application is executing screenshot or slideshow, this option is
Stop) to stop (start) display.
Click Exit to close application and stop screenshot or slideshow if the application is
executing.
d. If Avalue Driver - T1000 not install or T1000 device not connect, it will see the error
message as below when click Init.

EPD-4200
18 EPD-4200 Quick Reference Guide
e. The T1000 device information will show when initial success.
f. Both Display and Clear apply Start X/Start Y/Width/Height setting, others setting
only apply for Display.
Interval range is 1 ~ 600 seconds and it is set for screenshot and slideshow.
Start X/Start Y is set the display start x/y axis position.
Width/Height is set the display width/height size.
Waveform mode is set the display mode.
Flip horizontal/Flip vertical/Rotate 90°is set the display direction.
Full panel will ignore Start X/Start Y/Width/Height.

Quick Reference Guide
EPD-4200 Quick Reference Guide
19
g. When click Display the application will disable all the setting option.
Screenshot function will capture full screen to show.
Slideshow function will show the BMP files which in the select folder.
Single function will show the BMP file is selected.

EPD-4200
20 EPD-4200 Quick Reference Guide
3.3 Installation
a. Plug 12V adapter into the EPD-4200 and connect it with a box PC or an SBC via an USB
cable (Type A to Type A). After that, connect the box PC or SBC to a monitor via
HDMI/DP/VGA…etc. and then power on both box PC or SBC and EPD-4200.
b. Refer to the item 1.Driver to install T1000 device driver.
c. Open EPD-4200 T1000 test tool folder to execute “T1000 Test.exe”
Table of contents
Other Avalue Technology Monitor manuals