manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Avantes
  6. •
  7. Work Light
  8. •
  9. Avantes AvaLight-HAL User manual

Avantes AvaLight-HAL User manual

Popular Work Light manuals by other brands

Conrad 77 70 78 operating instructions

Conrad

Conrad 77 70 78 operating instructions

EBS Seeberg 1 Operation manual

EBS

EBS Seeberg 1 Operation manual

Pelican 9460 user manual

Pelican

Pelican 9460 user manual

Anslut 425-080 User instructions

Anslut

Anslut 425-080 User instructions

Govee H6071 user manual

Govee

Govee H6071 user manual

LumX INSPEC LED instruction manual

LumX

LumX INSPEC LED instruction manual

LED2WORK TECLED User instructions

LED2WORK

LED2WORK TECLED User instructions

ANSMANN POWERLIGHT 5.1 operating instructions

ANSMANN

ANSMANN POWERLIGHT 5.1 operating instructions

RTRMAX RTX1868 instruction manual

RTRMAX

RTRMAX RTX1868 instruction manual

FeinTech LAL00220 quick start guide

FeinTech

FeinTech LAL00220 quick start guide

Bunker Hill Security 64735 user manual

Bunker Hill Security

Bunker Hill Security 64735 user manual

Goobay 30450 user manual

Goobay

Goobay 30450 user manual

REV Ritter SPOT Assembly and operating instructions

REV Ritter

REV Ritter SPOT Assembly and operating instructions

Ignition Stagepix Line 100 IP user manual

Ignition

Ignition Stagepix Line 100 IP user manual

SCANGRIP DUO CONNECT manual

SCANGRIP

SCANGRIP DUO CONNECT manual

Bosch GLI 18 V operating instructions

Bosch

Bosch GLI 18 V operating instructions

Bayco SL-1514 instruction manual

Bayco

Bayco SL-1514 instruction manual

EUFAB SMD LED 8+1 operating instructions

EUFAB

EUFAB SMD LED 8+1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

24-08-04 AvaLight-HAL manual.doc 1
Avantes www.avantes.com [email protected]m
AvaLight-HAL Tungsten Halogen light source Operating Manual
PS-24VDC power supply
Starting up
1. Plug in the PS-24V power supply .
2. Plug in the connector of the power supply into the socket of AvaLight-HAL.
3. Connect the SMA-connectors of your fibers to the SMA-plug
4. Switch on the Halogen lamp with the switch .
Settings for high power or long lifetime
The AvaLight-HAL is factory set for optimal power output (medium setting), with an internal jumper the optical
energy can be controlled (see table).
Jumper setting Optical output Color temperature Exp. Lifetime
LOW 70% Ca. 2.700K > 2.000 hrs.
MEDIUM (default) 100% Ca. 2.850K 1.000 hrs
HIGH 150% Ca. 3.000K < 1.000 hrs.
The internal jumper settings can be changed, please follow instructions:
1. Remove screw protection caps on the backside
2. Loosen 2 screws with philips screwdriver
3. remove backplane
4. take out electronics board
5. Adjust jumper settings according to scheme below
6. put back electronics board, be carefull notto pinch the
electrical wires
7. put back backplane, screws and screw protection caps
SMA plug
24V Power supply
On-Off switch
Screw caps
Jumper JP1
24-08-04 AvaLight-HAL manual.doc 2
Avantes www.avantes.com [email protected]m
Lamp house
Lamp socket
Light bulb
Adjustment of focusing in SMA fiber
The AvaLight is factory adjusted to optimally focus the output into a 200µm fiber. If lower optical power is
recommended or a different fiber (bundle) diameter is used, the optical power can be adjusted.
1. Connect your fiber optic spectrometer or your optical power meter to a fiber to the AvaLight-HAL SMA
socket (4) .
2. Loosen blocking-screw with delivered Allen key (1,3mm).
3. By shifting the SMA socket you can optimize your optical power.
4. Secure position by tightening the blocking screw .
Changing the light source bulb
1. Plug out the power connector from the socket.
2. Remove screw protection caps on the frontside
3. Loosen 2 screws with philips screwdriver
4. turn the lightsource upside down
5. take out the frontplate and lamphouse
6. remove 2 nylon screws from lamp socket
7. take out the lamp socket
8. take out the bulb (carefull, may be hot)
9. replace by new bulb, do not touch glass with
your fingers
10. put back lamp socket and nylon screws
11. Slide back front plate and lamp house, be
carefull not to pinch the electrical wires
12. put back screws and protection caps
24-08-04 AvaLight-HAL manual.doc 3
Avantes www.avantes.com [email protected]m
Technical Data
AvaLight-HAL
(standard) AvaLight-HAL (long
life)
AvaLight-HAL (high
power)
Wavelength
Range 360 -2000 nm
Stability ± 0.1%
Time to stabilize Ca. 15 min.
Output to bulb 12.7 VDC/ 0.9A 11.3 VDC/ 0.8A 14.1 VDC/ 1.0A
Bulb Life 1000 hrs > 2000 hrs < 1000 hrs
Optical power
200µm fiber 20 mWatt 13 mWatt 27 mWatt
Optical power
400µm fiber 80 mWatt 50 mWatt 100 mWatt
Optical power
600µm fiber 150 mWatt 100 mWatt 200 mWatt
Bulb Color
Temperature 2.850 K 2.700 K 3.000 K
DB-15 connector Pin 10 = GND
Pin 13 = TTL input, high –shutter open, low shutter closed
Power
requirement
24 VDC / 1.25A
Dimensions (mm)
132 x 110 x 44 mm
Ordering Information
AvaLight-HAL 10W Tungsten Halogen Lamp, fan-cooled, needs extra PS-24V/1.25A power supply
AvaLight-HAL-S
10W Tungsten Halogen Lamp, fan-cooled, incl. TTL shutter, needs extra PS-
24V/1.25A power supply
AvaLight-HAL-S-
RM
Rack mounted version of the 10W Tungsten Halogen Lamp, fan-cooled, incl. TTL
shutter
IC-DB15-2Interface cable AvaSpec to AvaLight-HAL-S
AvaLight-HAL-B
10W Tungsten Halogen Replacement bulb for AvaLight-HAL, AvaLight-HAL-S
CUV-HAL Direct attach cuvette holder for AvaLight-HAL
PS-24V/1.25A Power supply 100-240VAC/24VDC, 1.25A, necessary for AvaLight-HAL