Avaya 4000 Series Original operating instructions

You can download all documents referenced in this Quick Installation Guide at
www.avaya.com. You do not require a support contract to download documents.
When downloading documentation, select the specific software version.
Depending on your hardware model, your switch can appear different than the
figures shown in this guide.
Confirm that you have the following tools and package contents:
Tools Required:
• Phillips #2 screwdriver
• Console cable to match the console connector on the switch (DB-9 or RJ-45)
• Console cable or Ethernet cable (if using the default IP address to access the
device for configuration)
Package Contents:
Model Primary PSU Optional Secondary PSU
ERS 4526T-PWR+,
ERS 4550T-PWR+,
ERS 4826GTS-PWR+,
ERS 4850GTS-PWR+
ERS 4826GTS,
ERS 4850GTS
ERS 4526FX,
ERS 4526T,
ERS 4526T-PWR,
ERS 4550T,
ERS 4550T-PWR,
ERS 4524GT,
ERS 4524GT-PWR,
ERS 4526GTX
ERS 4526GTX-PWR,
ERS 4548GT
ERS 4548GT-PWR
300w AC power supply
(replacement order code:
AL1905?03-E5)
1000w AC supply
(replacement order code:
AL1905?21-E6)
The ERS 4500 models contain built-in power supplies.
They do not support field replaceable power supplies.
300w AC power supply
(order code: AL1905?03-E5)
1000w AC power supply
(order code: AL1905?21-E6)
PEC Code Name Short Description
AL2011020-E6
AL2011022-E6
AL2011021-E6
Avaya RJ-45/DB-9
CONSOLE CABLE
AVAYA RED DB-9
FEMALE TO
RJ-45 ADAPTOR
AVAYA BLUE
DB-9 MALE TO
RJ-45 ADAPTOR
1.8m cable with DB-9 Female for terminal/PC on one
end and RJ-45 for device console port connectivity on
the other.
Converts DB-9 MALE to RJ-45 serial port. The adaptor
can be used for PC or device with DB-9 MALE console
port. Also, can be used with Category 5 RJ-45 straight
cable to provide console connection.
Converts DB-9 FEMALE to RJ-45 serial port. This
adaptor can be used to convert DB-9 of AL2011013-E6
console cable to RJ-45.
Ethernet Routing
Switch 4000 Series
4
3
5
6
2
1`
SpeedSpeedSpeed
Link/ActLink/ActLink/Act
RPS
246 8 10 12 14 16 18 20 22 24
1357911 13 15 17 19 21 23
PWR
Status
Link/Act
InUse
USB
Down
Up
Base
4548GT
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48 Console
45
46
47
48
1. Avaya Ethernet Routing Switch 4000 Series.
2. Rack-mounting hardware that includes:
• Rack-mount brackets (2)
• Screws to attach brackets to the switch (8)
• Screws to attach the switch to the equipment rack (2x4)
3. Rubber footpads.
4. AC power cord. (Note: A power cord is not included for the A variant of
the switch)
5. Standard 1.5 foot (46 cm) stacking cable.
6. Documentation includes the Base software license kit, Quick Install poster,
and Regulatory documents.
Note: Field replaceable power supply already installed in the switch. Two field
replaceable power supplies are supported for models ERS 4526T-PWR+, ERS
4550T-PWR+, ERS 4826GTS, ERS 4826GTS-PWR+, ERS 4850GTS, and
ERS 4850GTS-PWR+. One power supply is already installed.
Note: Be sure to order Direct Attach cables and SFP or SFP+ Transceivers
if required.
a. (Optional) Prepare the rack
1. Provide the equivalent of one rack of vertical space for each switch in an EIA or
IEC-standard 19-inch (48.2-centimeter) equipment rack.
2. Ensure that the equipment rack is stable and securely attached to a
permanent structure.
3. Ground the rack to the same grounding electrode used by the power service in the
area. The ground path must be permanent and must not exceed 1 Ohm of
resistance from the rack to the grounding electrode. AVAYA recommends using a
filter or surge suppressor.
b. When you install the switch into a network, ensure to use
the following cables:
• Category 5E or higher specification cabling must be used for 1 Gbps/1000
Mbps operation.
• RJ-45 and DB-9 console port cables and adaptors are as follows:
PEC Code Description (all are RoHS compliant)
AL4518002-E6
AL4518001-E6
AL4518003-E6
4000-SSC HiStack Stacking Cable 46cmm (1.5ft) for Ethernet Routing
Switch 4500 or 4800 series (for use as spare).
4500-SSC HiStack Stacking Cable 1.5 Meters (5ft) for Ethernet Routing
Switch 4500 series spare or for use as return cable for resiliency.
4500-SSC HiStack Stacking Cable 3m (10ft) for Ethernet Routing Switch
4500 series spare or for use as return cable for resiliency.
AL4518004-E6 4000-SSC HiStack Stacking Cable 5m (16.4ft) for Ethernet Routing Switch
4500 or 4800 series (spare or for use as return cable for resiliency).
c. Stacking cables
Table or shelf mounting
If you are mounting the ERS 4000 switch on a table or shelf, attach the rubber feet on
the underside of the switch by placing a pad near each corner.
Set the device on a flat surface near an AC power source, making sure there is at least
2 inches (5.1 cm) of space on all sides for proper air flow, and at least 5 inches
(12.7 cm) at the back for power cord clearance.
1. Attach a bracket to each side of the switch.
2. Slide the switch into the rack.
3. Insert and tighten the rack-mount screws.
Avaya
1Before you start
Quick Installation for Avaya Ethernet Routing Switch 4000 Series
2
3Mounting options
4Rack mounting
To set IP parameters using the console port and CLI Quickstart, perform the
following tasks:
http://support.avaya.com
1-800-242-2121 (U.S.A.)
1-866 GO-AVAYA
1-866-462-8292 (US Sales)
© 2013 Avaya Inc.
Poster part number: 700507446
NN47205-304, 01.01
Recommended reading
For more information, go to http://support.avaya.com and
download the following ERS 4000 guides:
•
Locating Documentation and Regulatory Reference (NN47205-100)
•
Documentation Reference for Avaya Ethernet Routing Switch
4000 Series (NN47205-101)
•
Installing Avaya Ethernet Routing Switch 4000 Series (NN47205-300)
•
Quick Start Configuration (NN47205–104)
•
Configuring Systems (NN47205–500)
•
Release Notes (NN47205-400)
ACLI boot and factory-default commands:
boot - reboot the switch
boot default - reboot and use the factory default configuration
boot partial-default - reboot and use the partial factory default configuration
restore factory-default - reset the switch to factory default configuration
Connector Pin Number Signal
1Ready to send (RTS) — optional, can swap or link with pin 8
2 Data terminal ready (DTR)
3Transmit data (TXD) — mandatory
4 Carrier detect (DCD) — optional
5 Ground (GND) — mandatory
6 Receive data (RXD) — mandatory
7 Data set ready (DSR) — optional
8 Clear to send (CTS) — optional, can swap or link with pin 1
Property Value
Baud Rate 9600 bps
Data Bits 8
Stop Bits 1
Parity None
Flow Control None
Terminal emulation settings
###############################################################################
Welcome to the 4850GTS-PWR+ setup utility.
You will be requested to provide the switch basic connectivity settings.
After entering the requested info, the configuration will be applied and
stored into the switch NVRAM.
Once the basic connectivity settings are applied, additional configuration
can be done using the available management interfaces.
Use Ctrl+C to abort the configuration at any time.
###############################################################################
Please provide the Quick Start VLAN <1-4094> [1]:
Please provide the in-band IP Address[172.16.120.20]:
Please provide the in-band sub-net mask[255.255.255.0]:
Please provide the Default Gateway[172.16.120.1]:
Please provide the Read-Only Community String[**********]:
Please provide the Read-Write Community String[**********]:
Please provide the in-band IPV6 Address/Prefix_length[::/0]:
Please provide the in-band IPV6 Default Gateway[::]:
###############################################################################
Basic switch parameters have now been configured and saved.
###############################################################################
Connector Pin Number Signal
1Carrier detect (not used)
2Transmit Data (TXD)
3Receive Data (RXD)
4Data terminal ready (not used)
5Signal ground (GND)
6Not used
7Request to send (not used)
8Not used
9 Ring indicator (not used)
Setting IP parameters using the console port and CLI quick start
8Connect the console cable to the ERS 4000
The Avaya Ethernet Routing Switch 4000 Series provides fail-safe stackability. You can
connect up to eight 4000 Series devices in a stack to provide uninterrupted connectivity
for up to 400 ports. You can manage the stack as a single unit.
ERS 4000 series rear panel
The Avaya Ethernet Routing Switch 4000 series back panel provides a Base Unit
Select switch, Cascade Down connector, and Cascade Up connector for stacking
purposes as shown below:
Cascade Down Cascade Up
Unit Select
Base
1 2 3
1= Cascade down connector
2= Cascade up connector
3= Base Unit Select switch
Base Unit Select switch – used to designate the base unit in a stack. When set to the
RIGHT position, this unit acts as the Base Unit for the stack. The default position for
this switch is as non-base unit.
Cascade Down and Cascade Up connectors – used to connect a switch to the next
unit in the stack through a cascade cable. Connect one end of the Cascade Down
cable to the Cascade Up connector of the next switch in the stack (shown in the
simplified stacking diagram below):
To create a stack connection, order the appropriate Avaya Ethernet Routing Switch
4000 Series cascade cables to ensure fail-safe stacking. For stacking three or more
units (maximum eight units per stack), order the 5 ft, 10 ft, 14 ft or 16.4 ft cables as
applicable (see section 2b for Order Codes).
1. Ensure that all switches for the stack are rack mounted.
2. Slide the Base Unit Select switches on the back of the units to the appropriate
position, depending on whether they are a base unit or non-base unit:
• Base Unit (Unit 1) - Slide the Base Unit Select switch to the RIGHT
• Non-Base Unit (Units 2-8) - Slide the Base Unit Select switch to the LEFT
Because stack parameters are associated with the base unit, the physical stack
order depends on the base unit position and whether you configure the stack
cascade up (stack up) or cascade down (stack down). This designation depends
on the stack cabling arrangement.
IMPORTANT: Avaya recommends you to use a Cascade Down configuration.
3. Connect stacking cables as required for a Cascade Up (stack up) or Cascade Down
(stack down) configuration as shown below:
Connect the AC power cord to the back of the switch, and then plug the other end
of the cord into an AC power outlet.
Warning: You must use a power cord set approved for the 4000 Series switch and the
power receptacle type in your country.
Check the front-panel LEDs as the device powers on to be sure the PWR LED is
lit. If not, check if the power cord is plugged in correctly.
The switch will power on immediately when it is connected to a suitable AC
power source.
Before installing SFP and SFP+ transceivers, ensure the switch is up, fully booted, and
operating normally. Verify that the SFP or SFP+ transceivers and network cabling
support your network configuration.
Install SFP transceivers by performing this procedure.
1. Remove the transceiver from the protective packaging.
2. Verify that the transceiver is the correct model for the
network configuration.
3. Grasp the transceiver between your thumb and forefinger.
4. Insert the transceiver into the proper module on the switch.
Apply a light pressure to the transceiver until it clicks and
locks into position in the module.
3
1
24
PoE
Depending on your ERS 4000 switch model, the console port is either the RJ-45 port
outlined with a blue border, or the DB-9 port on the front of your ERS 4000 Series switch
(note orientation). Use an RJ-45 to DB-9 cable, or a DB-9 to DB-9 serial cable to connect
the switch console port to your management terminal. Adapters are available to provide
different connection options. The maximum length of a console cable is 25 feet (8.3
meters). The following tables describe the RJ-45 and DB-9 console port pin-out
information. You can use the pin-out information to verify or create a console cable for
use with your maintenance terminal.
DB–9 Console port pin assignments
1. Connect the console cable from the terminal to the console port of the switch to allow
initial configuration. Any terminal or PC with the appropriate terminal emulator can be
used as the management station.
2. Set the terminal protocol on the terminal
or terminal emulation program to
VT100 or VT100/ANSI.
3. Connect to the switch using the terminal
or terminal emulation application.
4. The Avaya switch banner appears when
you connect to the switch through the
Console port. There is no default password for the switch for CLI console access.
Enter Ctrl+Y and type the following CLI commands:
• enable
• install
5. The CLI Quickstart welcome screen helps you enter the information requested at
each prompt.
Note: The ERS 4000 uses the default IP address of 192.168.1.1/24 if the switch does
not get its IP address from another source.
RJ–45 Console port pin assignments
Unit 1
Unit 2
Unit 3
Unit 4
Unit 5
Unit 6
Unit 7
Unit 8
1
2
4
3
Unit 1
Unit 2
Unit 3
Unit 4
Unit 5
Unit 6
Unit 7
Unit 8
1
2
4
3
Cascade Down (Stack Down) configuration
1= Base unit
2= Last unit
3= Cascade/Stack Cable
4= Cascade/Stack Cable (Return cable to make
stack resilient. Use longer stack cable if required.)
Unit 8
Unit 1
Unit 2
Unit 3
Unit 4
Unit 5
Unit 6
Unit 7
1
2
4
3
Cascade Up (Stack Up) configuration
1= Base unit
2= Last unit
3= Cascade/Stack Cable
4= Cascade/Stack Cable (Return cable to make
stack resilient. Use longer stack cable if required.)
Unit 1
Unit 2
Unit 3
1
2
3
Simplified Stacking diagram
1= Base unit
2= Last unit
3= Cascade/Stack Cable
5Stacking
6Powering Up
7Installing SFP and SFP+ transceivers
9Connecting to the ERS 4000 embedded Web UI
1. Connect a Laptop/PC to any Ethernet port and ensure that the PC has an IP address
configured within the same IP subnet as the switch management IP address.
2. Start your web browser, such as Internet Explorer or Firefox.
3. Enter switch management IP address in the URL field and press Enter
(for example; 192.168.1.1).
4. The switch summary screen appears on your browser. Use the navigation tree on the
left to select switch configuration options.
Note: You do not need login credentials.

Other manuals for 4000 Series

4

This manual suits for next models

15

Other Avaya Switch manuals

Avaya P334T-ML Operator's manual

Avaya

Avaya P334T-ML Operator's manual

Avaya Cajun P333T User manual

Avaya

Avaya Cajun P333T User manual

Avaya Virtual Services Platform 7200 Series User manual

Avaya

Avaya Virtual Services Platform 7200 Series User manual

Avaya 8300 Series Instructions for use

Avaya

Avaya 8300 Series Instructions for use

Avaya 8600 User manual

Avaya

Avaya 8600 User manual

Avaya P460 User manual

Avaya

Avaya P460 User manual

Avaya P332G-ML User manual

Avaya

Avaya P332G-ML User manual

Avaya Cajun P333T User manual

Avaya

Avaya Cajun P333T User manual

Avaya 4900 Series Instruction Manual

Avaya

Avaya 4900 Series Instruction Manual

Avaya P330 User manual

Avaya

Avaya P330 User manual

Avaya P333R-LB Instruction Manual

Avaya

Avaya P333R-LB Instruction Manual

Avaya Ethernet Routing Switch 3600 Series User manual

Avaya

Avaya Ethernet Routing Switch 3600 Series User manual

Avaya P460 User manual

Avaya

Avaya P460 User manual

Avaya 2500 Series User manual

Avaya

Avaya 2500 Series User manual

Avaya Ethernet Routing Switch 8300 Series User manual

Avaya

Avaya Ethernet Routing Switch 8300 Series User manual

Avaya Hirschmann MACH1040 User manual

Avaya

Avaya Hirschmann MACH1040 User manual

Avaya P120 SMON User manual

Avaya

Avaya P120 SMON User manual

Avaya 8800 Series User manual

Avaya

Avaya 8800 Series User manual

Avaya Cajun P550R User manual

Avaya

Avaya Cajun P550R User manual

Avaya M770 User manual

Avaya

Avaya M770 User manual

Avaya 106760804 Operating manual

Avaya

Avaya 106760804 Operating manual

Avaya P333R-LB User guide

Avaya

Avaya P333R-LB User guide

Avaya VSP 7000 Series Instruction Manual

Avaya

Avaya VSP 7000 Series Instruction Manual

Avaya ERS 2500 Operating instructions

Avaya

Avaya ERS 2500 Operating instructions

Popular Switch manuals by other brands

Omnitron Systems Technology FlexCenter 10 user manual

Omnitron Systems Technology

Omnitron Systems Technology FlexCenter 10 user manual

Linksys LGS310C quick start guide

Linksys

Linksys LGS310C quick start guide

Rosewill RGS-1016 user manual

Rosewill

Rosewill RGS-1016 user manual

SSS Siedle SSM 611?01 Product information

SSS Siedle

SSS Siedle SSM 611?01 Product information

Network Technologies SM-nXm-C5AV-LCD Installation and operation manual

Network Technologies

Network Technologies SM-nXm-C5AV-LCD Installation and operation manual

Yeastar Technology NeoGate TE100 Administrator's guide

Yeastar Technology

Yeastar Technology NeoGate TE100 Administrator's guide

Cisco IE-4000-4TC4G-E Hardware installation guide

Cisco

Cisco IE-4000-4TC4G-E Hardware installation guide

Pakedge Device & Software SE-8P2-EP user manual

Pakedge Device & Software

Pakedge Device & Software SE-8P2-EP user manual

PMC-Sierra PM5371 TUDX Specification sheet

PMC-Sierra

PMC-Sierra PM5371 TUDX Specification sheet

steute Ex AZ 16 2O/1S-3D Mounting and wiring instructions

steute

steute Ex AZ 16 2O/1S-3D Mounting and wiring instructions

H3C S12500 Series Reference

H3C

H3C S12500 Series Reference

Brocade Communications Systems VDX 6940 Series Hardware installation guide

Brocade Communications Systems

Brocade Communications Systems VDX 6940 Series Hardware installation guide

Dwyer Instruments TSW Series Installation and operating insctructions

Dwyer Instruments

Dwyer Instruments TSW Series Installation and operating insctructions

Interlogix NS3050-8T user manual

Interlogix

Interlogix NS3050-8T user manual

Network Technologies KEEMUX-P2 Installation & user guide

Network Technologies

Network Technologies KEEMUX-P2 Installation & user guide

LevelOne Infinity IES-1085 user manual

LevelOne

LevelOne Infinity IES-1085 user manual

EUCHNER STA Series operating instructions

EUCHNER

EUCHNER STA Series operating instructions

Comtrol Rocket linx ES8508 Quick installation guide

Comtrol

Comtrol Rocket linx ES8508 Quick installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.