Awenta PRO AQUILA 305 Specification sheet

________________________________________________________________
AWENTA Spółka Jawna, Warszawska 99, 05-300 Stojadła
AWP.VAR305.01A.2023_EN
Operation and Installation Manual
Air handling unit with heat recovery
+ duct distributor VARR75-160
AQUILA 305
Air handling unit equipped with Aero 4A ver.2 ventilation controller with NANO COLOR 10 control panel
Applies to models: VAR305L VAR305P

2

3
TABLE OF CONTENTS
1. OPERATOR’S MANUAL
1.1. IMPORTANT INFORMATION/SAFETY INSTRUCTIONS................................................................................................... 4
1.2. INTENDED USE ............................................................................................................................................................. 5
1.3. TRANSPORT AND STORAGE ......................................................................................................................................... 5
1.4. SAFETY MEASURES REGARDING OPERATING OF THE UNIT ......................................................................................... 5
1.5. TECHNICAL SPECIFICATION .......................................................................................................................................... 6
1.6. TECHNICAL DRAWINGS................................................................................................................................................ 6
1.7. BASIC COMPONENTS OF THE UNIT.............................................................................................................................. 7
1.8. LAYOUT OF CONNECTIONS .......................................................................................................................................... 8
1.9. OPERATION PRINCIPLE................................................................................................................................................. 9
1.10. ITEMS OF EQUIPMENT............................................................................................................................................... 9
1.11. INSTALLING AND PREPARING THE UNIT FOR OPERATION ......................................................................................... 9
1.12. MAINTENANCE......................................................................................................................................................... 12
1.13. PRE-HEATER / SECONDARY HEATER ......................................................................................................................... 13
1.14. WASTE MANAGEMENT NOTICE ............................................................................................................................... 14
2. NANO COLOR CONTROL PANEL
2.1. OPERATION PRINCIPLE............................................................................................................................................... 15
2.2. INSTALLATION ............................................................................................................................................................ 15
2.3. DESCRIPTION OF THE MAIN SCREEN ......................................................................................................................... 16
2.4. OPERATION MODE..................................................................................................................................................... 18
2.5. SETTINGS.................................................................................................................................................................... 19
2.6. TEMPERATURE SETTINGS........................................................................................................................................... 20
2.7. THERMOSTAT INFO .................................................................................................................................................... 20
2.8. VENTILATION INFORMATION SCREEN........................................................................................................................ 20
2.9. FIREPLACE MODE....................................................................................................................................................... 21
2.10. CHANGING THE SYSTEM OPERATION MODE ........................................................................................................... 22
2.11. SENSORS .................................................................................................................................................................. 23
2.12. VEX4 MODULE ......................................................................................................................................................... 25
2.13. SMART MODE .......................................................................................................................................................... 25
2.14. FOULED FILTER INDICATION..................................................................................................................................... 26
2.15. MAIN MENU............................................................................................................................................................. 26
2.16. SCHEDULE SETTINGS................................................................................................................................................ 27
2.17. SERVICE MENU......................................................................................................................................................... 27
2.17.1. IN-OUT .................................................................................................................................................................. 29
2.17.2. DISTRIBUTOR ........................................................................................................................................................ 29
2.17.3. NANO .................................................................................................................................................................... 29
2.17.4. VENTILATION......................................................................................................................................................... 31
2.17.5. SENSORS ............................................................................................................................................................... 33
3. NANO WIRELESS NETWORK...................................................................................................................................34
4. VLAN INEXT INTERNET MODULE ...........................................................................................................................34
5. WIRING DIAGRAMS
5.1. ELECTRICAL DIAGRAM OF THE AERO 4 CONTROLLER – version for operation diagram 1. Standard......................... 35
5.2. CONNECTING THE NANO COLOR CONTROL PANEL ................................................................................................... 36
5.3. CONNECTING THE NANO COLOR CONTROL PANEL WITH C14 - VRS NETWORK CONVERTERS ................................. 36
5.4. CONNECTING THE NANO COLOR CONTROL PANEL WITH THE iNEXT VLAN INTERNET MODULE .............................. 36
5.5. CONNECTING THE NANO COLOR CONTROL PANEL WITH VACS-1 AIR QUALITY SENSOR .......................................... 37
5.6. CONNECTING THE NANO COLOR CONTROL PANEL WITH THE VSHC or VSHW SENSOR………………………………………… 37
5.7. CONNECTING THE NANO COLOR CONTROL PANEL WITH VSHC or VSHW and VACS-1 SENSORS.............................. 37
5.8. CONNECTION OF A PREHEATER AND SECONDARY HEATER ....................................................................................... 38
6. ATTACHMENTS
6.1. PRODUCT DATA SHEETS/ENERGY LABELS .................................................................................................................. 38

________________________________________________________________
AQUILA 305 Instruction Manual
4
1. OPERATOR’S MANUAL
1. 1. IMPORTANT INFORMATION
Read the Operator’s Manual carefully before installation or any other activity related to work with the unit! AWENTA takes
not responsibility for any damage resulting from incorrect operation, non-intended use or unauthorised repairs or
modifications of the product.
This installation manual is an essential part of the product and contains important technical information and instructions
regarding the occupational safety. Carefully read the operation and installation manual and keep it available in a readily
accessible place for future reference. The manual is also available at www.awentapro.pl
Safety precautions:
● This product can be used by children at least 8 years old, by people with impaired
physical and/or mental abilities, and by people without any experience in or
understanding of the operation of the product, if supervised or instructed by a
competent adult in the safe use of the product so that they understand the relevant
operating risks. This product is not a toy and children should not play with it. Children
should not be allowed to clean or maintain the product without supervision of an
adult.
● The unit is intended for indoor electrical installation provided with means or devices
having contact breaks at all poles, ensuring complete isolation under category III
overvoltage conditions in accordance with the regulations for such installation. The
device should be connected directly to an earthed 230 VAC mains socket.
● When installing and using the unit, it is mandatory to observe the provisions specified
in this manual and all the applicable local and national building, electrical and
technical standards.
● It is imperative to read all warnings in this manual and become familiar with the
warning signs located on the air handling unit, as they contain information for your
safety.
● Failure to follow the instructions and warnings contained in this manual may result
in personal injury and damage to the unit.
● If the unit is handed over/sold etc. to another user, this manual must also be handed
over.
● Assembly and repairs of the unit may only be carried out after it has been effectively
disconnected from the power network.
● It is forbidden to operate the unit beyond the temperature range specified in the user
manual, as well as in aggressive and potentially explosive environments.
● Do not place heating or other devices near the power supply cable of the unit.
● It is forbidden to connect the device to the mains if the power cord is found damaged.
● If the inseparable power cord is damaged it should be replaced by the manufacturer,
a serviceman or by a qualified person in order to avoid hazards.
● The OHS rules must be observed, when using electrical equipment during the
assembly of the unit.
● Exercise care, when unpacking/unloading of the unit.
● Do not bend the power cord, avoid damaging it.
● Use the air handling unit only for its intended purpose. PE ЕС

________________________________________________________________
AQUILA 305 Instruction Manual
5
1.2. INTENDED USE
The unit is equipped with a cross-flow plate heat exchanger, electric heater (sold separately) and is designed to save
thermal energy by its recuperation, being one of the elements used in energy-saving technology systems. The unit is
considered a supplementary device and must not be used as a stand-alone, independent heating source.
The unit is intended for securing continuous air exchange by means of forced ventilation in houses, offices, hotels, cafés
and other residential and public premises, as well as for recuperation of heat energy from discharged air to heat up clean
air coming from the outside. External air is heated by transferring heat energy from the exhaust air stream via a heat
exchanger. The unit is not intended for industrial use.
Air flowing through the unit must not contain volatile flammable or explosive substances, chemically active vapours, dust
with large particles, soot, fats or media conducive to the formation of harmful substances (toxic substances, dust,
pathogenic microorganisms), sticky substances and fibrous materials.
The unit is designed for installation in a closed building, in the ambient air temperature from 0°C to +40°C, the relative
humidity of up to 90%.
WARNING! In the event of extremely unfavorable weather conditions (outside temperature below -10°C), it
is not recommended to use the air handling unit above 70% air flow. This may result in excessive cooling of
the room and incorrect operation of the device.
1.3. TRANSPORT AND STORAGE
Permissible storage and transport temperatures range from -20 to +50°C.
Transport and unpack the unit with care. Dispose of the packaging in an environmentally friendly manner.
1.4. SAFETY MEASURES REGARDING OPERATING OF THE UNIT
● Always and absolutely observe the safety regulations, warnings, comments, and cautions as recommended herein.
Failure to observe the safety regulations, warnings, and cautions and instructions in this document may result in personal
injury or damage.
● Do not touch the control panel or the electric feeder box with wet hands.
● It is forbidden to operate the unit with wet hands.
● The use of a high-pressure washer or water jet to clean the control panel is prohibited.
● Avoid any contact between the electric parts of the unit with water.
● It is not allowed to block the inlets and outlets of air conduits, when the unit is in operation.
● Maintenance of the unit may only be carried out, after it has been effectively disconnected from the power network.
● It is forbidden to place on the power supply cord any objects which could abrade, cut or damage it otherwise.
● It is forbidden to store explosive or flammable substances in the vicinity of the unit.
● It is forbidden to open the unit, when it is in operation.
● In case of unusual noise, odour and smoke, immediately turn the control panel off and contact the service centre or the
manufacturer.
● The installation of the unit should always be carried out in compliance with the general and local construction, safety
and installation regulations issued by the relevant official institutions and the energy and water supply companies.
● The unit should be connected to the ventilation system before commissioning. Ventilation ducts provide protection from
access to rotating fan blades. The ducts shall be secured against slipping off its connections in a manner requiring the
use of tools.

________________________________________________________________
AQUILA 305 Instruction Manual
6
1.5. TECHNICAL SPECIFICATION
Specifications:
AQUILA 305
Supply voltage
230 V AC / 50Hz
Maximum power consumption
210 W
Electrical protection class
I
IP protection class
IP22
Capacity (at 100 Pa)
313 m3/h
Max motor speed
4000 rpm
Noise level
49 dB(A)
Max. heat recovery efficiency
up to 95%
Heat exchanger material
Polystyrene
Housing material
EPP + powder coated steel
Filter – intake vent
M5 ISO ePM10 (optional F7 ISO ePM1)
Filter – exhaust
M5 ISO ePM10
Pre-filter intake/exhaust
VFWAR (optional)
Diameter of air connector
160 mm
Mounting position
Vertical (wall) or horizontal (ceiling)
Weight
16kg (VAR305) + 5kg (VARR75-160)
Controller type
AERO 4 + NANO COLOR
Dimensions [height x width x depth]
625 mm x 1042 mm x 282 mm
Dimensions VARR75-160 [height x width x depth]
693 mm x 1623,5 mm x 282 mm
By-pass
Automatic (100% by-pass)
Fans
2x radial fan with EC motor
Internet module
VLAN iNEXT (optional)
Air quality sensor
VACS-1 (optional)
CO2 concentration and humidity sensor
VSHC (optional)
Humidity sensor
VSHW (optional)
1.6. TECHNICAL DRAWINGS
VARE175

________________________________________________________________
AQUILA 305 Instruction Manual
7
VARE175 + VARR75-160
1.7. BASIC COMPONENTS OF THE UNIT
1.
By-pass damper
7.
Counter-flow heat exchanger
2.
Drip trays
8.
Air filters
3.
Controller
9.
Air distributor mounting brackets
4.
Fans
10.
Air distributor
5.
Connection pipes Ø160
11.
Connection pipes Ø75
6.
Air handling unit mounting brackets

________________________________________________________________
AQUILA 305 Instruction Manual
8
1.8. LAYOUT OF CONNECTIONS – LEFT /RIGHT VERSIONS
Left version (standard)
Right version
Connection ports designation:
INTAKE – outdoor air intake duct
EXHAUST – used air exhaust duct
EXTRACT – duct removing used air from rooms
SUPPLY – duct supplying air to rooms

________________________________________________________________
AQUILA 305 Instruction Manual
9
1.9. OPERATION PRINCIPLE
Fresh air is drawn in with the air intake located outside the building. Then, using ventilation ducts, the air is transported
to the air handling unit. After filtering, it flows to the heat exchanger where heat energy exchange from the exhaust
stream takes place. The air is heated in winter and cooled in the summer. Next, the supplied air flows to the so-called
“clean” areas such as a living room or bedroom.
Both, used and polluted air is extracted from the so-called “dirty” areas such as a toilet, bathroom, kitchen or laundry by
means of exhaust grilles or diffusers, and then directed to the air handling unit by means of exhaust ducts. After
filtering, it flows to the heat exchanger, where the heat or cold is “recovered” from the used air. The air is then moved to
an outlet located outside the building.
1.10. ITEMS OF EQUIPMENT
The standard accessories of the unit include the following:
● Cross-flow plate heat exchanger.
● M5 class supply and exhaust air filters.
● EC fans: centrifugal supply and extract fans with electrically commutated motors.
● NANO COLOR remote control panel which is connected, with a communication cable, to the control system, located
inside the electric compartment of the air handling unit.
● Wall bracket + securing angle bar.
CAUTION: Some of the units come with the dedicated VARR75-160 air Distribution Box.
1.11. INSTALLING AND PREPARING THE UNIT FOR OPERATION
Installation of the air handling unit
● The unit is designed for wall or ceiling mounting. The unit can be fixed to the wall or ceiling using the mounting brackets
included with the set.
● WALL MOUNTING
- Hang the unit at least 500 mm above the floor level which is the distance required to provide space for a condensate
drain trap, as well as air ducts if the VARR75-160 Distribution Box is used.
- Check whether the mounting structure can support the weight of the unit. If not, use additional beams to reinforce the
location intended for installation. The unit must be installed on a rigid and stable surface.
- The unit should be fixed to a vertical surface.
- To securely fix the air handling unit and distribution box on the mounting brackets, use dowels or other fasteners suitable
for the type of load bearing material. After fixing the unit, check it for stability.
① ②

________________________________________________________________
AQUILA 305 Instruction Manual
10
● CEILING MOUNTING
- The unit must be fixed to the ceiling allowing at least 500 mm length from the wall which is required to provide space
for the air ducts if the VARR75-160 distribution box is installed.
CAUTION: The ceiling to which the air handling unit will be fixed must not be permeable to water. It should effectively
protect the unit from flooding even if the building's plumbing system fails.
- Check whether the mounting structure can support the weight of the unit. If not, use additional beams to reinforce the
location intended for installation. The unit must be installed on a rigid and stable surface.
- The unit must be fixed to a vertical surface.
- To securely fix the air handling unit and distribution box on the mounting brackets, use dowels or other fasteners suitable
for the type of load bearing material. After fixing the unit, check it for stability.
① ②
- If the unit is built with an underside housing, allow at least 200 mm free space for the condensate drain trap.
③
● The unit should be installed so as to enable its free opening for the replacement of filters, cleaning the exchanger and
other maintenance.
● Make sure the power supply system is suitable for the maximum power of the appliance. The permissible temperature
of the intake air is -20 to +50° C.
● The air handling unit should be installed in rooms where the temperature is min. 0°C.
Minimum lengths of ventilation ducts
To ensure the best efficiency of the air handling unit and to reduce aerodynamic losses due to turbulence, it is
recommended to install a straight section of air duct at the entry and exit of the unit.
The minimum recommended lengths of such straight sections:
- 25 cm of an air conduit at the inlet side;
- 60 cm at the outlet side.
In case of lack or short air ducts on one or several ports of the air handling unit it is necessary to protect the unit's internal
parts against entry of foreign objects, for example, install a protective grid or other device with mesh size not larger than
12.5 mm, to prevent free access to the fans.
If the source of noise is where the spiral air duct is connected, replace the spiral air duct with a flexible duct to avoid
resonance. Flexible inserts can also be used to prevent resonating.

________________________________________________________________
AQUILA 305 Instruction Manual
11
Draining of condensate
Connect the flexible condensate drain pipe to one of the ports of the drip tray, depending on the unit configuration
(LEFT/RIGHT). The dia. 32 mm pipe should be bent to form a trap (the height difference between the upper and lower
elbow of the trap should be at least 100 mm). The drain pipes have to be arranged with a slope of approximately 2%.
NOTE: Fill the drain system with water, before starting the unit for the first time! The drain
trap must be filled with water during operation at all times.
Make sure that water flows into the drain, otherwise condensate may accumulate inside the
unit when the recuperator operates, which in turn may damage the unit and cause water
leakage into the room.
The condensate drain system must be used in all rooms, in which air temperature is above
0°C! If the room temperature is below 0°C the condensate drainage system has to be
thermally protected and equipped with a heating device to prevent it from freezing.
ATTENTION! Condensate drainage is also recommended in air handling units with an
enthalpy exchanger, as in special cases a small amount of condensate may accumulate.
Connecting to the mains power supply
The unit must be connected to a 230 V/50 Hz single-phase AC power supply network, using the original power cord
provided with the unit. Before connecting to the mains, check the cable for any mechanical damage caused by crushing,
cutting etc., which may result in an electric shock.
The unit must be connected to the power network, in compliance with the regulations and standards in force.
ATTENTION!
The control panel should be connected to a properly installed socket equipped with an earthing contact.
The power outlet should be located in an easily accessible place so that the plug can be pulled out easily in
case of danger. The panel ratings are given on the manufacturer's factory label. Any changes to the internal
connection are prohibited and will void the warranty.
Installation of air ducts
● The ventilation ducts should be secured against slipping from the connection stubs with cable ties.
● The distance between the air intake and the outlet should be at least 1.5 m.
● The air intake should be located on the shadiest building side as far as possible from sources of stale air (street, chimney,
etc.)
● Install the exhaust air duct with a slope to the unit.
● All ducts should be insulated to avoid inside condensation and excessive moisture accumulation.
● When installing the ducts, minimise the number of sharp bends, etc., to reduce resistance of the ducts.
● The ducting should be airtight. Use fittings with gaskets or seal the joints with e.g. adhesive aluminium tape.
● To reduce the transmission of vibrations and to make the unit run more quietly, connect it to the system with flexible
dampers on the intake and exhaust sides.
● The installation should follow a design prepared by an authorised designer.
● Make flow adjustments on the diffusers, based on measurements taken with an anemometer according to the air
balance obtained.
● Ceiling diffusers should be installed min. 30 cm from the walls.
● To ensure adequate flow between rooms:
- The gap under the internal door should have a minimum surface area of 7600 mm2
- At least 10 mm gap under a standard internal door with a width of 760 mm
- Do not cover the openings as this will disturb air circulation
● Recommended duct thickness depending on ambient temperature:
Air duct type:
Ventilation duct ambient temperature
from -20°C to 0°C
from 1°C to 14°C
from +15°C to 20°C
Insulation thickness for a given temperature range
Supply
20 mm + (200 mm)*
50 mm
20 mm
Exhaust:
20 mm + (200 mm)*
50 mm
20 mm
Intake
50 mm
50 mm
50 mm
Discharge
20 mm + (200 mm)*
20 mm
20 mm
*20 mm mineral wool insulation covered with aluminium foil on one side + a minimum of 200 mm of mineral wool as a
covering or casing for pipes laid in the attic without thermal insulation.
min. 100 mm

________________________________________________________________
AQUILA 305 Instruction Manual
12
1.12. MAINTENANCE
ATTENTION!
It Is absolutely necessary to disconnect the control panel from power supply before performing any
maintenance operations.
ATTENTION!
Do not use corrosive chemicals and solvents during any maintenance work.
Filter replacement/cleaning
Fouled filters increase air flow resistance which reduces the amount of air supplied to the rooms, and increases power
consumption by the fans.
The filters should be cleaned as they become dirty, but at least 3-4 times per year. It is permitted to clean the filters with
a vacuum cleaner. After cleaning twice, the filters should be replaced with new ones.
Optionally the air handling unit can be equipped with a pre-filter to extend the life of the fine filters. The pre-filter should
be rinsed under running water and then dried before re-insertion, as it is reusable.
Filter replacement procedure
● Remove the filter caps (1);
● Remove the pre-filters (2) – optional;
● Remove the M5/F7 filters (3);
● Install new or cleaned filters according to the above diagram in reverse order.
● Reset the dirty filter counter in the control panel menu.
CAUTION: When replacing the filters, make sure the arrow points in a direction compatible with the air flow.
Heat exchanger maintenance (annually)
Even with regular filter maintenance, dust deposits can form in the unit. In order to maintain high heat transfer efficiency,
the heat exchanger should be cleaned regularly. Remove the heat exchanger from the main unit and wash it with warm
water solution of neutral detergent, then reinstall the dried heat exchanger.

________________________________________________________________
AQUILA 305 Instruction Manual
13
Heat exchanger/fan cleaning procedure
● Remove the locking screws (1);
● Remove the locking screws (1);
● Remove the heat exchanger snap-in shield (2);
● Remove the fixing screws (3);
● Remove the exchanger bracket (4);
CAUTION: For the ceiling mounting, the exchanger can slide out after unscrewing the bracket!
● Remove the drip trays (5)
● Remove the heat exchanger (6) completely and rinse with running water (reassemble after drying);
● After cleaning, assemble the unit according to the above diagram in a reverse order.
Maintenance of the condensate drain system (once a year)
The condensate drain system (drain pipe) may be contaminated by particles from the evacuated air. Check the function of
the drain pipe, by filling the drain tank with water and, if necessary, removing dirt from the drain trap and drain pipe.
Maintenance of air intake and exhaust ducts (twice a year)
Leaves and other impurities can clog ventilation grates and reduce both the efficiency of the unit and air flow. Check the
intake/exhaust grille twice a year and clean it, if necessary.
Maintenance of the air ducting (every 5 years)
Even if all the aforementioned maintenance activities of the air handling unit are performed properly, dust deposits may
build up inside the air ducts, which reduces the air handling unit's efficiency. Air ducts are maintained by periodic cleaning
or changing them.
1.13. PRE-HEATER / SECONDARY HEATER
The air handling unit has a feature for controlling the preheater and reheater fitted externally of the unit. Connect these
heaters according to the diagram in Chapter 3.
Caution: The preheater installed upstream of the unit must come with a device that will prevent the temperature of the
intake air that enters the main unit from exceeding 50°C.
CAUTION: If no preheater is installed, switch off the supply fan for defrosting.

________________________________________________________________
AQUILA 305 Instruction Manual
14
1.14. WASTE MANAGEMENT NOTICE
. P
Do not dispose of waste electrical equipment with household waste.
The crossed-out wheelie bin symbol on this product that it is waste electrical an electronic
equipment (WEEE) at the end of its operating life and shall not be disposed with household waste.
The crossed-out wheelie bin symbol specifies that the product is subject to obligatory waste
segregation schedules for proper disposal. The product is made from recyclable materials and
components. The product user shall is required to return the product which has become WEEE to a
WEEE collection unit. The operators of WEEE collection units, including local WEEE locations,
product resellers and other WEEE collection locations managed by local authorities form a proper
waste disposal system. Proper WEEE disposal helps avoid harmful effects to humans and the
environment from the risk caused by hazardous components this product may contain. Your
household can make an important contribution to the recovery and recycling of WEEE. This
contribution fosters a behaviour which helps conserve the natural environment, which is a common asset for the mankind.
Households are among the leading consumers of small appliances and equipment. A rational management of operation
and disposal of small appliances and equipment will contribute to efficient recycling.

________________________________________________________________
AQUILA 305 Instruction Manual
15
2. NANO COLOR CONTROL PANEL
2.1. OPERATION PRINCIPLE
The NANO COLOR determines the set room temperature and ventilation performance based on the selected
operating program.
Possible programs:
● By clock zones. You can set up two Comfort operation zones and one Out of Home zone (no is one in the apartment).
Outside of these zones the Economy zone applies.
● Holiday mode. As above, but according to a separate daily program.
● Manual mode. One manually set temperature and one ventilation rate apply all the time.
● Out of Home. The settings as for the Out of Home zone apply all the time. This mode can only be set with the
thermostat number 1. The other thermostats adopt this mode from the thermostat number 1. Cooling in the Out of
Home program is turned off.
The set and ventilation temperature can still be affected:
● Enabling the URLOP mode. The thermostat and ventilation work as in the Out of Home mode.
● The Out of Home EXT signal, e.g. the one coming from a control panel. The thermostat and ventilation work as in the
Out of Home mode.
The difference between the HOLIDAY and the Out of Home in NANO 1 and Out of Home in the EXT software lies in different
interpretation of these states by the remaining equipment, e.g. the HOLIDAY mode switches off the DHW generation in
boiler controllers and heat pumps, while solar collectors stop accumulating heat and switch to the collector overheating
protection mode.
All of the above modes can only be set to NANO number 1. NANO1 then transfers them to the other NANOs and other
devices.
NANO COLOR can work in one of the three system operation modes:
● WINTER - NANO COLOR functions as the heating thermostat. The related equipment tends to achieve the set
temperature in the room, e.g. switching on the heating. The ventilation heats up the supplied air to the appropriate
temperature. The particular reaction depends on the configuration of the related equipment
● SUMMER – heating and cooling functions are off
● COOLING – heating is off. NANO COLOR functions as the cooling thermostat. The related equipment tends to cool the
room to the set temperature, e.g. by switching on fan coils, supply air cooler, opening the recuperator BY-PASS if the
conditions so require. The HOLIDAY, Out of Home and Out of Home EXT modes block the cooling operation.
The system operation mode can be changed manually or can change automatically depending on the outside
temperature.
2.2. INSTALLATION
General
The work related to connecting and assembling should only be carried out by persons with the appropriate qualifications
and permissions, and in line with the valid standards and regulations.
NOTE: Any connection work must only be carried out when the supply voltage is isolated, make sure that the electrical
conductors are isolated.
Power supply
The NANO COLOR control panel should be powered directly from AERO 4 controller outputs marked with “U” and “G”
symbols (12 VDC)
Connecting
The NANO COLOR control panel should be wired with a conductor of the minimum cross-section of 0.5 mm2 according to
the diagram in section CONNECTION DIAGRAMS. The minimum distance between conductors connecting the panel with
the module and other devices connected to the C14 network and parallel conductors supplied with 230 VAC is 30 cm. A
shorter distance may cause communication interference or damage to the device.
The following figure shows an example of a C14 network connection.
NOTE: In order to ensure smooth data transmission it is necessary to install a ferrite
filter on the power and communication wires between the AERO module and the
NANO COLOR thermostat. When leading the conductors through the filter loop them
around the ring as shown in the photo at the side.

________________________________________________________________
AQUILA 305 Instruction Manual
16
Installation site
The NANO COLOR control panel is installed in the front panel of the air handling unit as a standard. It is possible to relocate
or install an additional panel in the desired location in the house. The panel should be installed at the height of about 150
cm from the floor, away from sources of heat (e.g. radiators, TV set) and cold (e.g. external doors).
2.3. DESCRIPTION OF THE MAIN SCREEN
1
Digital communication indicating via C14 protocol, flashing orange dot indicates that
communication is in progress.
2
Menu button.
3
Operating mode button. Depending on the configuration, one of the following symbols will appear:
Operation without a thermostat and ventilation.
Operation with a thermostat.
Operation with ventilation.
Operation with a thermostat and ventilation.
4
Installation mode button. Depending on the selected mode one of the icons shown below is displayed:
Winter (heating).
Summer (without heating and cooling)
Cooling.
5
EX4 module (displayed when the option is enabled).
6
Screen button for detected devices (support for additional devices).
7
Fireplace mode. Activation of the FIREPLACE function in the ventilation service menu is required.

________________________________________________________________
AQUILA 305 Instruction Manual
17
Fireplace operation mode enabled.
Fireplace operation mode disabled.
8
The symbols appear for the enabled thermostat operation with heating and/or cooling. In the INTAKE TEMPERATURE
CONTROL MODE, the ROOM option should be set in the ventilation service menu.
Signal to other devices that the room is not heated enough and the heating needs to be turned
on.
Signal to other devices that the room is at the correct temperature (grey).
Signal to other devices that the room is overheated and cooling needs to be turned on.
Signal to other devices that the room is at the correct temperature (grey).
9
Ventilation on/off button.
It has to be turned on in the service parameter NANO / ON-OFF VENTILATION ON THE FIRST SCREEN.
Ventilation is switched on (green).
Ventilation is off (red). In addition to that, “OFF” will be displayed in field 14.
10
The current reading of the information configured in the service parameter NANO/GENERAL INFORMATION.
11
Current room temperature setpoint. Activation of the thermostat operation in service parameter
VENTILATION/THERMOSTAT FUNCTION (Heating, Cooling, Heating+Cooling) is required.
12
Air quality and humidity. When pressed, a screen appears where detailed air parameters can be
viewed. They are visible when sensors are connected.
See section 2.11. for a detailed description.
13
Press to display a chart of the outside temperature variations over the last 24 hours, including
the minimum and maximum temperatures recorded during that time. This information is not
displayed if there is no outside temperature sensor.
14
Current ventilation operation status.
15
Current ventilation run. Displaying “OFF” means that the ventilation is switched off with
the button 9.
16
Current ventilation operation mode (scheduled, holiday, manual).
17
Current work zone (comfort, eco, out of home, holiday).
18
Current operating status of the thermostat.
19
Current operating status of the thermostat (schedule, holiday, manual).

________________________________________________________________
AQUILA 305 Instruction Manual
18
20
Current work zone (comfort, eco, out of home, holiday).
21
Clock. Press to display the date and time setting screen
2.4. OPERATION MODE
When the mode selection button (button 3 of the main screen) is pressed the mode screen appears, depending on the
configuration.
1
Moves to the thermostat and ventilation settings. See the SETTINGS section for a
detailed description.
2
Returns to the main screen.
3
Moves to the thermostat information screen.
4
Scheduled mode.
5
Holiday mode.
6
Manual mode.
7
Activation of the GHE in automatic operation mode or deactivation. The GHE
operation is possible after enabling the option.
8
Click to set the scheduled mode for the thermostat and ventilation simultaneously.
9
Click to set the holiday mode for the thermostat and ventilation simultaneously.

________________________________________________________________
AQUILA 305 Instruction Manual
19
10
Moves to ventilation information screen.
11
Scheduled mode.
12
Holiday mode.
13
Manual selection of the ventilation operation mode.
14
Enables the OUT OF HOME (NANO1) program.
15
Enables the HOLIDAY program.
16
Switches the BY-PASS to automatic mode, constantly closing or opening it.
17
Switches the ventilation to air mode. The option is invisible when the OUT OF HOME
(NANO1) or HOLIDAY mode is on.
2.5. SETTINGS
Clicking the button 1 from the OPERATION MODES section brings up the following screen:
1
Moves to the schedule settings.
2
Exits to the previous screen.
3
Sets the fan speed for the comfort zone.
4
Sets the fan speed for the economic zone.
5
Sets the fan speed for the OUT OF HOME mode.

________________________________________________________________
AQUILA 305 Instruction Manual
20
6
Click to display the temperature setting screen. APPEARS AFTER THE OPTION
HAS BEEN ENABLED.
2.6. TEMPERATURE SETTINGS
Clicking the button 6 from the SETTINGS section brings up the following screen. Use the and buttons to set the
desired temperature.
1
Setting comfort temperature.
2
Setting the economic temperature.
3
Set the temperature in the OUT OF HOME mode.
2.7. THERMOSTAT INFO
After clicking the button 3 from the OPERATION MODE section, the screen will display the details of the currently
measured room temperature and the temperature setting.
2.8. VENTILATION INFORMATION SCREEN
After clicking the button 10 from the OPERATION MODE section, the ventilation screen shows a window with a graphical
representation of the exchanger.
NOTE: Depending on the connected devices installed in the air handling unit (heaters, coolers, AHU Kit), the screen may
differ from those shown in the manual.
This manual suits for next models
2
Table of contents
Other Awenta Air Handler manuals
Popular Air Handler manuals by other brands

Exhausto
Exhausto VEX300 Series Mechanical assembly and electrical installation

BLAUBERG Ventilatoren
BLAUBERG Ventilatoren KOMFORT LE Series Operation manual

Surna
Surna Surna IsoStream SCMAHV-42 operating & maintenance manual

American Standard
American Standard 2/4TEC3F18A1000A Installer's guide

Komfovent
Komfovent Domekt REGO Installation and operation manual

Ingersoll-Rand
Ingersoll-Rand TAM7A0A24H21EA Installer manual