Delete code
1. Enter programming mode
2. Press the function key for the code to be deleted.
3. Exit programming mode by pressing B or wait for 30 seconds.
Change unlock time
1. Enter programming mode
2. Press the function key
OPEN TIME
.
3. Enter the desired unlock time (01-99 seconds).
4. Exit programming mode by pressing B or wait for 30 seconds.
Set relay function (NO / NC)
1. Enter programming mode
2. Enter one of the following:
lEnter A090 for NC relay function.
lEnter A091 for NO relay function (Managed).
3. Exit programming mode by pressing B or wait for 30 seconds.
Blocking after invalid code
Three incorrect attempts (four digits) block the code lock.
Reset takes place automatically after 1 minute or by entering a valid code twice.
Factory reset
1. Enter programming mode
2. Enter A 00199200.
Factory settings
l7 seconds unlocking time
lNo codes
lNO relay function (Normally open)
3 (4) ManualA04