Technische Daten:
Übertragungsnorm ................................................................PAL BG/I
Frequenzbereich............................................47...446/470…862 MHz
Kanäle.................................................................................VHF 2...12
.............................................................................S02...S10/S11...S38
........................................................................................UHF 21…69
Durchgangsdämpfung..................................................................4 dB
Ausgangspegel ......................................................................85 dBµV
HF Ausgangsimpedanz............................................................75 Ohm
Video Eingangsimpedanz........................................................75 Ohm
Audio Eingangsimpedanz......................................................10 kOhm
Video Eingangspegel ..................................................................1 VSS
Audio Eingangspegel..................................................................1 VSS
Anschlüsse HF .......................................................................F-Buchse
Anschluss Video .............................................................Cinch-Buchse
Anschluss Audio (stereo)..............................................Cinch-Buchsen
Stromaufnahme ......................................................................200 mA
Maße ca. (L x B x H)................................................120 x 90 x 30 mm
Netzteil ....................................................230 V~/50 Hz 9 V=/300 mA
Sicherheitshinweise:
4Die Installation des Geräts und Reparaturen am Gerät sind
ausschließlich vom Fachmann unter Beachtung der geltenden VDE-
Richtlinien durchzuführen. Bei nicht fachgerechter Installation und
Inbetriebnahme wird keine Haftung übernommen.
4Vor Öffnen des Gerätes Netzstecker ziehen bzw. Stromzuführung
entfernen, andernfalls besteht Lebensgefahr. Dies gilt auch, wenn Sie das
Gerät reinigen oder an den Anschlüssen arbeiten.
4Verwenden Sie nur das im Lieferumfang enthaltene Steckernetzteil! Es
dürfen auf keinen Fall am Steckernetzteil Teile ausgetauscht oder
Veränderungen vorgenommen werden. Es besteht sonst Lebensgefahr,
für die keine Haftung übernommen wird.
4Sofern eine austauschbare Sicherung vorhanden ist, ist vor dem Wechsel
der Sicherung der Netzstecker zu ziehen. Defekte Sicherungen nur durch
normgerechte Sicherungen des gleichen Nennwertes ersetzen.
4Das Gerät darf nur in trockenen Räumen betrieben werden. In feuchten
Räumen oder im Freien besteht die Gefahr von Kurzschlüssen (Achtung:
Brandgefahr) oder elektrischem Schlägen (Achtung: Lebensgefahr).
4Planen Sie den Montage- bzw. Aufstellort so, dass Sie in
Gefahrensituationen den Netzstecker leicht erreichen und aus der
Steckdose ziehen können. Wählen Sie den Montage- bzw. Aufstellort so,
dass Kinder nicht unbeaufsichtigt am Gerät und dessen Anschlüssen
spielen können. Der Montage- bzw. Aufstellort muss eine sichere
Verlegung aller angeschlossenen Kabel ermöglichen.
Stromversorgungskabel sowie Zuführungskabel dürfen nicht durch
irgendwelche Gegenstände beschädigt oder gequetscht werden.
4Wählen Sie einen Montage- bzw. Aufstellungsort, an dem unter keinen
Umständen Flüssigkeiten oder Gegenstände in das Gerät gelangen
können (z. B. Kondenswasser, Dachundichtigkeiten, Gießwasser etc.)
4Setzen Sie das Gerät niemals direkter Sonneneinstrahlung aus und
vermeiden Sie die direkte Nähe von Wärrmequellen (z. B. Heizkörper,
andere Elektrogeräte, Kamin etc.) Bei Geräten, die Kühlkörper oder
Lüftungsschlitze haben, muss daher unbedingt darauf geachtet werden,
dass diese keinesfalls abgedeckt oder verbaut werden. Sorgen Sie
außerdem für eine großzügig bemessene Luftzirkulation um das Gerät.
Damit verhindern Sie mögliche Schäden am Gerät sowie Brandgefahr
durch Überhitzung. Achten Sie unbedingt darauf, dass Kabel nicht in die
Nähe von Wärmequellen (z.B. Heizkörper, andere Elektrogeräte, Kamin
etc.) kommen.
Ihr Gerät ist mit dem WEEE-Symbol markiert (Waste Electronics
and Electrical Equipment). Dies bedeutet, dass elektrische und
elektronische Komponenten nicht mit dem Restmüll entsorgt
werden dürfen. Gebrauchte elektrische und elektronische
Komponenten sind separat zu entsorgen.
WEEE Nr.
DE14023300
Hersteller
AXING AG
Gewerbehaus Moskau
8262 Ramsen
EWR-Kontaktadresse
Bechler GmbH
Am Rebberg 44
78239 Rielasingen
Stand 2016-08-22 Technische Änderungen, Änderungen im Design,
Druckfehler und Irrtümer vorbehalten.

Verwendungsbereich und Produktbeschreibung:
Die Geräte sind ausschließlich für den Einsatz zum Verteilen von Radio- und
Fernsehsignalen im Haus geeignet! Wird das Gerät für andere Einsätze
verwendet, wird keine Garantie übernommen!
Der Audio-/Video-Modulator moduliert ein A/V-Signal in einen HF-Kanal zum
Anschluss an ein TV-Gerät oder zur Einspeisung in eine Gemeinschaftsanlage.
Am Eingang wird beispielsweise eine CCD-Kamera, ein Videorecorder, ein DVD-
Player oder ein ähnliches Gerät angeschlossen. So kann mit einer Kamera ein
Kinderzimmer, ein Hauseingangsbereich oder ein sonstiger sensibler Bereich
überwacht werden.
Ausgangsseitig wird mittels einfachster Programmierung ein Kanal eingestellt,
der ansonsten nicht belegt ist.
Signaleinspeisung
z.B. über Multischalter
z.B. über AVM 5-00
Programmierung des Ausgangskanals
Den AVM 6-00 mit dem Power Schalter einschalten. Durch drücken der +
bzw. – Taste werden die Kanäle eingestellt. Der angezeigte Wert wir
automatisch gespeichert.
Mit der SET Taste kann das VHF Kanalraster zwischen It(Italien ) und Eu(
Deutschland) umgeschaltet werden. Das in Deutschland verwendete Raster
wird durch ein kurzes blinken mit Eu gekennzeichnet. In dieser Einstellung
werden die VHF Kanäle im Display mit einem E davor angezeigt. Bei
Sonderkanäle steht ein S vor der Zahl. Vor UHF Kanälen steht keine Kennung.
Funktionsmenü
Durch gleichzeitiges Drücken von +.- können Sonderfunktionen eingestellt
werden.
Die möglichen Einstellungen sind in nachfolgender Tabelle aufgeführt.
1.Ziffer 2.Ziffer Einstellung
Bild-Tonträgerabstand 0 0 4,5 MHz
0 1 5,5 MHz (ab Werk)
0 2 6,0 MHz
0 3 6,5 MHz
Signalgenerator 1 0 aus (ab Werk)
1 1 an
Tonträgeampitude 2 0 12 dB
2 1 16 dB (ab Werk)
Mit der SET Taste wird das Funktionsmenü verlassen.
POWER-Schalter
SET-Taste
LED-Anzeige
- und + Taste

AVM 6-00
Audio/video modulator
Operation Instructions
Safety advice:
4Installation and repairs to the equipment may only be carried out by
technicians observing the current VDE guidelines. No liability will be
assumed in the case of faulty installation and commissioning.
4Before opening the equipment pull out the power plug or remove the
power supply, otherwise there is danger of electrocution. This is also
valid for cleaning the equipment or working on the connections.
4Use only the plug-in power supply unit included in the delivery scope!
By no means is it allowed to replace any parts of the power supply unit
or to make modifications. Otherwise, there is a risk of mortal injury for
which we cannot be held liable.
4Providing that a serviceable fuse exists, the power cord must be pulled
out before changing the fuse. Defective fuses may only be replaced with
standard compliant fuses that have the same nominal value.
4The equipment may only be operated in dry rooms. In humid rooms or
outdoors there is danger of short-circuit (caution: risk of fire) or
electrocution.
4Choose the location of installation or mounting so that the power plug
can be reached and pulled out of the socket easily in case of danger.
Choose the location of installation or mounting such that children may
not play unsupervised near the equipment and its connections. The
location of installation or mounting must allow a safe installation of all
cables connected. Power feeding cables as well as feeder lines may not
be damaged or clamped by objects of any kind. To prevent damage to
your equipment and to avoid possible peripheral damages, the devices
foreseen for wall mounting may only be installed on a flat surface.
4Choose the location of installation or mounting so that under no
circumstances liquids or objects can get into the equipment (e.g.
condensation, water coming from leaking roofs or flowing water, etc.).
4Avoid exposure of the equipment to direct sunlight and to other heat
sources (e. g. radiators. other electrical devices, chimney, etc.). Devices
that are equipped with heat sinks or ventilation slots must under no
circum-stances be covered or blocked. Also ensure for a generous air
circulation around the equipment. In this way you avoid possible
damage to the equipment as well as a risk of fire caused by overheating.
Absolutely avoid that cables come near any source of heat (e.g.
radioators, other electrical devices, chimney, etc.).
Technical specifications:
WEEE Nr.
DE14023300
Your device is marked with the WEEE symbol (Waste Electronics
and Electrical Equipment). This means that the electrical and
electronic components must not be disposed of as residual waste.
Used electrical and electronic components must be disposed of
separately.
Transmission norm.................................................................PAL BG/I
Frequency range............................................47...446/470…862 MHz
Channels.............................................................................VHF 2...12
.............................................................................S02...S10/S11...S38
........................................................................................UHF 21…69
Through loss.................................................................................4 dB
Output level ...........................................................................85 dBµV
HF Output impedance.............................................................75 Ohm
Video input impedance...........................................................75 Ohm
Audio input level...................................................................10 kOhm
Video input level.........................................................................1 VSS
Audio input level ........................................................................1 VSS
RF Connectors........................................................................F-female
Connector video..................................................................RCA/Cinch
Connector audio (stereo) ....................................................RCA/Cinch
Current consumption ..............................................................200 mA
Dimensions appr. (L x W x H)...................................120 x 90 x 30 mm
Power supply ...........................................230 V~/50 Hz 9 V=/300 mA
State of the art 6-08-22 Technical changes, design modifications, 201
errors and misprints are subject to change without prior notice.
Manufacturer
AXING AG
Gewerbehaus Moskau
8262 Ramsen
EWR contact adress
Bechler GmbH
Am Rebberg 44
78239 Rielasingen

Field of application and product discription
The devices are suited only for distributing radio and television signals in the
house! If the device is used for other purposes, no warranty is given!
The Audio/Video Modulator modulates an A/V signal in a RF channel to connect
to a television set or to feed a small house network.
At the input one may connect a CCD camera, a VCR, a DVD player or a similar
item. In this way a children´s room, a house entrance or another sensitive area
can be monitored.
With easy programming steps, a channel, which is not used for TV-transmission,
can be selected to transmit the signal from the input source.
e.g. through multiswitch
e.g. through AVM 5-00
Signal feeding
Programming of the output channel
Switch on the AVM 6-00 on the power switch. To set the channels, press the +
or key. The displayed value is automatically stored.
To switch the VHF channel spacing from It (Italy) to Eu (Germany), press the
SET key. The spacing used in Germany is identified by briefly flashing Eu. In
this setting, the VHF channels will be shown with the prefix E on the display.
For special channels, an S is shown in front of the number. No ID is shown for
UHF channels.
Functions menu
Special functions can be set by simultaneously pressing + -.
The possible settings are shown in the following table
1st digit 2nd digit Setting
picture-sound carrier offset 0 0 4,5 MHz
0 1 5,5 MHz (default)
0 2 6,0 MHz
0 3 6,5 MHz
Signal generator 1 0 off (default)
1 1 on
Sound carrier amplitude 2 0 12 dB
2 1 16 dB (default)
To leave the functions menu, press the SET Key
POWER switch
SET button
LED display
- and + button
Table of contents
Languages:
Other axing Modulator manuals

axing
axing UIM 1-00 User manual

axing
axing AVM 1-02 User manual

axing
axing basic UIM 1-0 User manual

axing
axing HKM 40-02 User manual

axing
axing HKM 40-0 Series User manual

axing
axing basic-line Series User manual

axing
axing basic-line AVM 3-00 User manual

axing
axing Premium-line HKM 40-00 User manual

axing
axing AVM 1-02 User manual

axing
axing HKM 40-02 User manual
Popular Modulator manuals by other brands

Velleman
Velleman CM31011 user manual

Logenex
Logenex SCDM-HD1 Installation and configuration manual

GSS
GSS HDM 660 T Assembly instructions

Comtech EF Data
Comtech EF Data Radyne DM240XR Installation and operation manual

ITS Telecom
ITS Telecom EKSELANS CM COMPACT 8S4 user manual

GSS
GSS HDM 500 C Assembly instructions