Unit 21, Highview, High Street, Bordon, Hampshire. GU35 0AX.
Tel: +44 (0)1420 487788 Fax: +44 (0)1420 487799
www.axio.co.uk
© Copyright Axio 2004. All Rights Reserved
AX-FC-MTYxxx - Issue 2.1 - 27/9//2010
AX-FC-MTYxxx
Manual Speed Controller For Small Motors
Page 2 of 2
FSC005MTY
FSC005MTX
FSC010MTY
0 1 - 1 0A 0 2 - 2 0A 0 4 - 4 0A
Fuse
(5x20mm) FF630mA FF1 25A FF2 5A FF5A
From maximum to minimum speed
From minimum to maximum speed
1Line In 230Vac 50/60Hz
2Can be used as either switched Line Out
(uncontrolled) OR
as Line In, bypassing switch.
3Neutral In
4Neutral Out to Motor or Fan
5Controlled Line Out to Motor or Fan
All except AX-FC-MTx040 Series may be Inset or
Surface Mounted, the AX-FC-MTx040 Series may
only be surface mounted.
Installation must only be carried out by a fully trained
electrician and must be in accordance with local
regulations. Disconnect or otherwise completely turn
OFF the electricity supply before installation. It is the
installers responsibility to ensure that installation is
carried out in a safe manner and that the final installation
complies with all relevant standards.
Inset Mounting
Disconnect the electricity supply
Remove the Controller from the supplied Surface Mount Case
by gently pulling. Then pull off the adjustment knob and
undo the securing nut. The front plate will then lift off.
Connect the relevant cables in accordance with the wiring
diagram above and in accordance with local regulations. Mount
the inner case to the wall with the electrical connections
pointing down, using the mounting holes provided. Replace
the Front Plate with the included packing, secure with the nut,
and gently press the knob on to the spindle with the detent on
the knob pointing to the OFF position. When all is secure, re-
connect the electricity supply.
Surface Mounting
Disconnect the electricity supply
Remove the Controller from the supplied Surface Mount Case
by gently pulling. Then pull off the adjustment knob and
undo the securing nut. The front plate will then lift off. Mount
the surface mounting case to the wall using suitable screws.
Connect the relevant cables in accordance with the wiring
diagram above and in accordance with local regulations. Mount
the inner case into the surface mounting case using the screws
Specification: Dimensions:
Connection Diagram:
Installation: