manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Azbil
  6. •
  7. Security Sensor
  8. •
  9. Azbil FL7M Series User manual

Azbil FL7M Series User manual

Thank you for purchasing our proximity sensor.
This manual contains information for ensuring correct
and safe use of this product.
Please read and understand the manual thoroughly
before using this product, and keep the manual nearby
after installation for handy reference.
Please read the "Terms and Conditions" from the
following URL before ordering or use:
http://www.azbil.com/products/bi/order.html
 2004-2013 Azbil Corporation All Rights Reserved.
■Specifications
Shielded type proximity sensor (suitable for flush mounting
onto metal)
■Circuit and Wiring
●Pre-wired type (NPN) FL7M-_A/B_
●Pre-wired type (PNP) FL7M-_D/E_
●Pre-wired connector type (NPN)
FL7M-1P5A6-CN03
•Aload must be used when power is applied to the sensor.
•Acombination of short circuit and wrong wiring will cause
permanent damage, regardless of short-circuit protection.
•When connecting a connector fasten tightly by hand.
■Dimensions
●FL7M-1P5_6_
●FL7M-2_6_
●FL7M-5_6_
●FL7M-10_6_
■Operating Chart for Output and Indicator
■Mutual Interference
Erroneous operation due to mutual interference is caused when
sensors are installed in parallel or facing each other.
Separate the sensors by at least the distance specified in the
table below.
■Influence from Adjacent Metal
Metals opposite the sensor's sensing face must be removed to
avoid false actuation.
Keep metals away from the sensors as specified below.
Shaded areas indicate surrounding metal other than the target
object.
A : Distance between front of iron plate and sensing face of
proximity sensor.
B : Distance between side of iron plate and center of proximity
sensor sensing face.
■Tightening Torque
●When a nut is used
The permissible torque is different depending upon the
distance from the top of the sensor head. Tighten the body at
less than the maximum permissible torque shown below,
and always with the enclosed nuts and washers.
The tightening torque varies depending on the mounting
plate or housing, the nut and washer material, and the
condition of the mounting surface. Check that the torque is
suitable for the actual combination of items before use.
Handling Precautions
• Do not tighten the body by applying torque to the
indicator unit (plastic unit).
• Do not mount the body using a setscrew. Doing so
might damage the sensor.
■AND Connection (Serial Connection)
When connecting two sensors in series, please pay attention to
the following:
•Maximum output current (100mA) ≥load current + current
consumption (13mA)
•Supply voltage ≥operation voltage of a load + 2 x voltage
drop (2V)
•If target moves too quickly,
sensor may operate incorrectly.
•In series, sensor A may operate
incorrectly on startup, because
sensor A is supplied power from sensor B's output.
Handling Precautions
• With serial connections the sensor may be briefly
unusable due to power fluctuation. Check the
system before use.
■OR Connection (Parallel Connection)
Up to three of these sensors may be connected in parallel.
■Points to be Aware of When Handling
•Do not swing the sensor by the cable.
•Do not pull the cable with excessive force.
•Do not use the sensor outdoors, or where it is surrounded by
chemicals (solvents, acids, alkalies, etc.).
•If bending the cable, keep R (the radius of the bend) ≥(the
cable diameter) x 3 at least.
•When disposing of an FL7M Series switch, dispose of it
appropriately as industrial waste in accordance with
applicable bylaws and regulations.
■Wiring cautions
•Route the wires of the sensor separately from power lines or
through an exclusive conduit. Otherwise, electrical noise or a
surge may cause faulty operation or damage.
•If an extension of the cable is necessary, use at least a
0.3mm2wire of 100m maximum length.
•When using a commercial switching regulator, ground the
FG (Frame Ground) and G (Ground) terminals. Otherwise,
switching noise may cause faulty operation.
•When using a load to generate a transient current, connect a
current limit resistor between the load and the output
terminal. (Otherwise, the short-circuit protection may be
activated.)
Proximity Sensors FL7M Series
(3-wire DC Type)
User's Manual
CP-UM-5373E
Model number FL7M-
1P5_6_2_6_5_6_10_6_
Size M8 M12 M18 M30
Sensing distance 1.5mm 2mm 5mm 10mm
Setting distance 0 to 1.05mm 0 to 1.4mm 0 to 3.5mm 0 to 7mm
Standard target 8 x 8 x 1mm 12 x 12 x 1mm18 x 18 x 1mm 30 x 30 x 1mm
(steel)
Hysteresis 10% max. of sensing distance
Supply voltage 10 to 30Vdc
Current 13mA max.
consumption
Output Load current: 100mA max.
Voltage drop: 2V max.
Withstand voltage: 30V max.
Operating -25 to +70°C -10 to +60°C
temperature
Insulation 50MΩmin. (500Vdc)
resistance
Dielectric strength 1000Vac 1min
Sealing IP67 (IEC Standard)
Circuit protection Surge voltage protection, reverse polarity protection,
short circuit protection
Load
Brown
Black
10 to 30Vdc
Blue
+V
0V
OUT
NPN
10 to 30Vdc
+V
0V
OUT
PNP
Load
Brown
Black
Blue
10 to 30Vdc
+V
0V
OUT
NPN
Load Connector
face view
12
34
30
26
M8 x 1
3
7
Nut
Indicator
Tooth washer
Vinyl insulated cable
(4 dia. 0.3mm )
2
Unit: mm
M12 x 1
938
33
104
Nut
Indicator
Tooth washer
Vinyl insulated cable
(4 dia. 0.3mm )
2
M18 x 1
1243
38
4 10
Nut
Indicator
Tooth washer
Vinyl insulated cable
(6 dia. 0.5mm )
2
5 10
43
48 12
M30 x 1.5
Nut
Indicator
Tooth washer
(6 dia. 0.5mm )
2
Vinyl insulated cable
OFF
OFF ON
RED OFF
ON OFF
Sensing distance
RED
Proximity
Sensor
Indicator
Output
Indicator
Output
FL7M-_A/D6_
(N.O.)
FL7M-_B/E6_
(N.C.)
B
A
A(mm) B(mm)
FL7M-1P5_6_15 20
FL7M-2_6_20 30
FL7M-5_6_35 50
FL7M-10_6_70 100
B
A
B
A(mm) B(mm)
FL7M-1P5_6_4.5 6
FL7M-2_6_89
FL7M-5_6_20 13.5
FL7M-10_6_40 22.5
Part A Part B
Distance (mm) Permissible torque (N•m)
FL7M-1P5_6_9912
FL7M-2_6_0-20
FL7M-5_6_0-70
FL7M-10_6_0-180 PartBPartALoad
+
+
-
-
OUT
OUT
i
iL
iVs
A
B
OUT
OUT
Vs
Load
+
+
-
-
Specifications are subject to change without notice. (09)
1-12-2 Kawana, Fujisawa
Kanagawa 251-8522 Japan
URL: http://www.azbil.com 1st edition: Sep. 2004 (M)
3rd edition: Aug. 2013 (F)

This manual suits for next models

4

Other Azbil Security Sensor manuals

Azbil RHS301R0 User manual

Azbil

Azbil RHS301R0 User manual

Azbil AUD300C1000 Series User manual

Azbil

Azbil AUD300C1000 Series User manual

Azbil Leak Detector II User manual

Azbil

Azbil Leak Detector II User manual

Azbil AUD100 Series User manual

Azbil

Azbil AUD100 Series User manual

Azbil HY7045T1000 User manual

Azbil

Azbil HY7045T1000 User manual

Azbil AUD10C1000 User manual

Azbil

Azbil AUD10C1000 User manual

Azbil AUD300C1000 Series User manual

Azbil

Azbil AUD300C1000 Series User manual

Azbil KFLB User manual

Azbil

Azbil KFLB User manual

Azbil KDP Series User manual

Azbil

Azbil KDP Series User manual

Azbil AUD300C1000 Series Operating instructions

Azbil

Azbil AUD300C1000 Series Operating instructions

Azbil AUD15 User manual

Azbil

Azbil AUD15 User manual

Popular Security Sensor manuals by other brands

Prime DS100 operating instructions

Prime

Prime DS100 operating instructions

Niko 351-25010 quick start guide

Niko

Niko 351-25010 quick start guide

nedis WIFISM10WT quick start guide

nedis

nedis WIFISM10WT quick start guide

Honeywell RAEGuard 2 PID user guide

Honeywell

Honeywell RAEGuard 2 PID user guide

Velleman PIR416 user manual

Velleman

Velleman PIR416 user manual

Rielta chrana ORLAN-SH installation guide

Rielta

Rielta chrana ORLAN-SH installation guide

Meccanica Fadini Polo 44 quick start guide

Meccanica Fadini

Meccanica Fadini Polo 44 quick start guide

Johnson Controls DSDN quick start guide

Johnson Controls

Johnson Controls DSDN quick start guide

Autonics LSE-4A5R2 manual

Autonics

Autonics LSE-4A5R2 manual

AECO QMP000040 manual

AECO

AECO QMP000040 manual

Rielta CELSIUS-RK installation guide

Rielta

Rielta CELSIUS-RK installation guide

roco Z21 X16 user manual

roco

roco Z21 X16 user manual

Sensit TKX instruction manual

Sensit

Sensit TKX instruction manual

ECOTEST Gamma Sapiens operating manual

ECOTEST

ECOTEST Gamma Sapiens operating manual

Texecom CAPTURE D20-W manual

Texecom

Texecom CAPTURE D20-W manual

Emerson Rosemount 2140 quick start guide

Emerson

Emerson Rosemount 2140 quick start guide

PCB Piezotronics ICP 105C12/NC Installation and operating manual

PCB Piezotronics

PCB Piezotronics ICP 105C12/NC Installation and operating manual

Deta EVOLO EVC7007 User's operation manual

Deta

Deta EVOLO EVC7007 User's operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.