B.A. International BA ULTIMATE POWER+ Series User manual

_^=riqfj^qb=mltbo=H=L=_^=riqfj^qb
båÖäáëÜ=L=aÉìíëÅÜ=L=cê~å´~áë=L=bëé~¥çä=L=fí~äá~åç=L=kÉÇÉêä~åÇë
_^=OMM=L=_^=QM=L=_^=SM=L=_^=OUM
_^=ORM=L=_^=QR=L=_^=SR
léÉê~íáåÖ=fåëíêìÅíáçåë
dÉÄê~ìÅÜë~åïÉáëìåÖ
kçíáÅÉ=ÇÛìíáäáë~íáçå
fåëíêìÅÅáçåÉë=ÇÉ=ìëç
fëíêìòáçåá=ÇDìëç
dÉÄêìáâÉêëÜ~åÇäÉáÇáåÖ
6401553_Titel.fm Seite 1 Mittwoch, 25. Mai 2016 11:02 11

6401553_Titel.fm Seite 2 Mittwoch, 25. Mai 2016 11:02 11

_^=riqfj^qb=mltbo=H=L=_^=riqfj^qb
båÖäáëÜ
léÉê~íáåÖ=fåëíêìÅíáçåë
_^=OMM=L=_^=QM=L=_^=SM=L=_^=OUM
_^=ORM=L=_^=QR=L=_^=SR Operating Instructions
6401553.book Seite 1 Montag, 13. Juni 2016 4:27 16

Table of contents Operating Instructions BA ULTIMATE POWER + / BA ULTIMATE
264 01 553 D3551.201.03.03.02
Table of contents
1Before you begin … ........................................................................................ 5
1.1 Structure of the document ............................................................................................. 6
1.2 Service life..................................................................................................................... 9
2Safety information........................................................................................... 11
3Technical description ...................................................................................... 13
3.1 Task............................................................................................................................... 13
3.2 Functionality .................................................................................................................. 13
3.3 BA ULTIMATE POWER + design.................................................................................. 14
3.4 BA ULTIMATE design ................................................................................................... 16
3.5 Technical data ............................................................................................................... 17
3.6 Production data .............................................................................................................22
6401553.book Seite 2 Montag, 13. Juni 2016 4:27 16

Operating Instructions BA ULTIMATE POWER + / BA ULTIMATE Table of contents
64 01 553 D3551.201.03.03.02 3
4Preparation ..................................................................................................... 24
4.1 Initial start-up and longer breaks in use ........................................................................ 24
4.2 Prior to starting the work day......................................................................................... 24
4.3 Before each patient ....................................................................................................... 24
5Operation ........................................................................................................ 26
5.1 Replacing the instrument............................................................................................... 27
5.2 Inserting and removing burr instruments....................................................................... 28
5.3 Adjusting the cooling spray ........................................................................................... 35
6Follow-up ........................................................................................................ 36
6.1 After each treatment session......................................................................................... 36
6.2 At the end of the work day............................................................................................. 37
6401553.book Seite 3 Montag, 13. Juni 2016 4:27 16

Table of contents Operating Instructions BA ULTIMATE POWER + / BA ULTIMATE
464 01 553 D3551.201.03.03.02
7Conditioning.................................................................................................... 38
7.1 Conduct pre-disinfection................................................................................................ 38
7.2 Automated cleaning and disinfecting............................................................................. 39
7.3 Manual cleaning and disinfection .................................................................................. 40
7.4 Manual maintenance ..................................................................................................... 43
7.5 Sterilizing....................................................................................................................... 46
8Maintenance ................................................................................................... 49
8.1 Maintenance of cooling spray nozzles .......................................................................... 50
8.2 Testing the FG clamping system................................................................................... 51
6401553.book Seite 4 Montag, 13. Juni 2016 4:27 16

Operating Instructions BA ULTIMATE POWER + / BA ULTIMATE 1Before you begin …
64 01 553 D3551.201.03.03.02 5
1Before you begin …
Complies with state-of-the-art technology and general standards
BA ULTIMATE POWER + / BA ULTIMATE complies state-of-the-art
technical regulations. BA ULTIMATE POWER + / BA ULTIMATE
complies with the ISO 14457 standard.
Read/observe _ general
1. Read the operating instructions prior to using BA ULTIMATE
POWER + / BA ULTIMATE.
2. Only use BA ULTIMATE POWER + / BA ULTIMATE for the
applications described in the operating instructions.
3. Observe the applicable hygiene standards, occupational safety
regulations and accident prevention measures for BA ULTIMATE
POWER + / BA ULTIMATE.
Intended Use Straight and contra-angle handpiecesHolding and driving burr instruments _ rotary or oscillatory processing
BA ULTIMATE POWER + / BA ULTIMATE is used to hold and drive burr
instruments for the purposes of rotary or oscillatory processing and is
intended for the following uses in dentistry:
6401553.book Seite 5 Montag, 13. Juni 2016 4:27 16

1Before you begin … Operating Instructions BA ULTIMATE POWER + / BA ULTIMATE
664 01 553 D3551.201.03.03.02
decayed materials, fillings, crown cements
● Removal of carious material and fillings; cavity and crown
preparation of hard tooth substance; processing tooth and
restoration surfaces; processing of dental prostheses: crowns,
fillings, bridges (red, blue and green contra-angle handpieces)
Prophylaxis_T2 LIN
● Prophylaxis (blue and green contra-angle handpieces)
Endodontics _ without special contra-angle handpiece
● Endodontics (blue and green contra-angle handpieces)
Implantology and surgery _ blue, green
● Implantology, surgery, processing of bones (blue and green contra-
angle handpieces)
Prosthetics _ Handpiece, blue and green contra-angle handpieces
● Prosthetics (handpiece, blue and green contra-angle handpieces)
Contraindications - none
Contraindications None
Target group trained dental personnel
This product is intended only for use by trained dental personnel in
dental practices and laboratories.
6401553.book Seite 6 Montag, 13. Juni 2016 4:27 16

Operating Instructions BA ULTIMATE POWER + / BA ULTIMATE 1Before you begin …
64 01 553 D3551.201.03.03.02 7
1.1 Structure of the document
1.1.1 Labeling of information
Warnings ➢ To prevent injuries, please observe all warnings.
Warnings are labeled as follows:
DANGER! indicates a danger leading to death or serious injury if not
avoided.
WARNING! indicates a danger that may lead to death or serious
injury if not avoided.
CAUTION! indicates a danger that may lead to injury if not avoided.
Instructions for use ➢ To prevent material damage and additional expenses, please
observe all instructions for use.
Instructions for use are labeled as follows:
NOTICE! indicates measures for the prevention of material damage.
6401553.book Seite 7 Montag, 13. Juni 2016 4:27 16

1Before you begin … Operating Instructions BA ULTIMATE POWER + / BA ULTIMATE
864 01 553 D3551.201.03.03.02
IMPORTANT: indicates information on the avoidance of additional
expenses and other important information.
Tip: indicates information for facilitating work.
1.1.2 Formats and symbols
The formats and symbols used in this document have the following
meaning:
6401553.book Seite 8 Montag, 13. Juni 2016 4:27 16

Operating Instructions BA ULTIMATE POWER + / BA ULTIMATE 1Before you begin …
64 01 553 D3551.201.03.03.02 9
✔ Prerequisite
1. First action step
2. Second action step
or
➢Alternative action
Result
➢Individual action step
Requests you to do something.
Use of formats and symbols [ →
8].
Identifies a reference to another
text passage and specifies its
page number.
● List Identifies a list.
6401553.book Seite 9 Montag, 13. Juni 2016 4:27 16

1Before you begin … Operating Instructions BA ULTIMATE POWER + / BA ULTIMATE
10 64 01 553 D3551.201.03.03.02
1.1.3 Abbreviations/codes used
T1 LINE / T1 CLASSIC
1.2 Service life
When used as intended:
Service life_Sirona
● Non-moving parts have a typical service life of 5 years
● Moving parts have a typical service life of 3 years
No warranty claim can be inferred here, as wear may occur earlier or
later than indicated above depending on use, frequency of sterilization,
and frequency of maintenance.
FG Friction grip burr instrument
CA Contra-angle handpiece burr instrument
HP Straight handpiece burr instrument
6401553.book Seite 10 Montag, 13. Juni 2016 4:27 16

Operating Instructions BA ULTIMATE POWER + / BA ULTIMATE 2Safety information
64 01 553 D3551.201.03.03.02 11
2Safety information
Obligations of the user
Obligations of the user ● Use only fault-free materials that do not deviate from the specified
data [ → 17].
● Protect yourself, patients, and others against any foreseeable
dangers. To do this, follow the safety information.
● Comply with the Intended use of the equipment.
● You should always keep these operating instructions within reach for
further reference.
Cross contamination and spread of infections
Preventing the spread of infections and cross
contamination
Sterilization
Prevent the spread of infections and cross contamination between
patients, users, and third parties. Sterilize equipment after each patient.
Take the appropriate hygiene measures, e.g. wear protective gloves.
Emitted cooling air
Emitted cooling air The cooling air emitted by the coupling of the motor must have a flow
rate of 1.5 - 10 Nl/min.
Instrument head overheating
Instrument head overheating If the instrument is defective, the area around the instrument head may
heat up, thus creating a risk of burning the patient's oral mucosa.
6401553.book Seite 11 Montag, 13. Juni 2016 4:27 16

2Safety information Operating Instructions BA ULTIMATE POWER + / BA ULTIMATE
12 64 01 553 D3551.201.03.03.02
Malfunction / Damage _ Instruments
Malfunction or damage Discontinue use immediately in case of malfunction, unusual or different
sounds or damage. Damaged instruments may cause injury. Notify the
dental depot or the manufacturer.
Repair_instrument
Repair Do not repair the instrument yourself.
Repair _ BA
The BA instrument is the result of a precise development and must not
be disassembled by third parties. In the case of service or repair work,
please send the instrument in an assembled state to B.A. International
Ltd. or to a service center approved by B.A. International.
Accessories _ not approved by Sirona
Spare and accessory parts Use only original parts produced by the manufacturer.
If you have any questions, please contact your dental depot or the
manufacturer.
6401553.book Seite 12 Montag, 13. Juni 2016 4:27 16

Operating Instructions BA ULTIMATE POWER + / BA ULTIMATE 3Technical description
64 01 553 D3551.201.03.03.02 13
3Technical description
3.1 Task
Instrument
The instrument transmits the driving power and speed of the electric
motor or air motor to the preparation tool.
3.2 Functionality
Instrument
The transmission ratio of the instrument distorts the operating speed of
the preparation tool.
6401553.book Seite 13 Montag, 13. Juni 2016 4:27 16

3Technical description Operating Instructions BA ULTIMATE POWER + / BA ULTIMATE
14 64 01 553 D3551.201.03.03.02
3.3 BA ULTIMATE POWER + design
Contra-angle handpiece
G
F
D
C
B
A
E
A Instrument head
B Push button
C Cooling spray outlet
D Opening of chuck system
E Light aperture
F Color coding for gear ratio
G ISO slider
6401553.book Seite 14 Montag, 13. Juni 2016 4:27 16

Operating Instructions BA ULTIMATE POWER + / BA ULTIMATE 3Technical description
64 01 553 D3551.201.03.03.02 15
Straight handpiece
DE
C
B
A
A Opening for the clamping system
B Cooling spray outlet
C Light aperture
D Center part of handpiece
E ISO slider
6401553.book Seite 15 Montag, 13. Juni 2016 4:27 16

3Technical description Operating Instructions BA ULTIMATE POWER + / BA ULTIMATE
16 64 01 553 D3551.201.03.03.02
3.4 BA ULTIMATE design
G
F
D
C
B
A
E
A Instrument head
B Pushbutton
C Cooling spray aperture
D Opening of chuck system
E Light aperture (only in the case of BA 250LT/BA 45LS/BA
65LS)
F Color coding for transmission ratio
G ISO slider (only in the case of BA 250LT/BA 45LS/BA 65LS)
6401553.book Seite 16 Montag, 13. Juni 2016 4:27 16

Operating Instructions BA ULTIMATE POWER + / BA ULTIMATE 3Technical description
64 01 553 D3551.201.03.03.02 17
3.5 Technical data
BA ULTIMATE POWER +/BA ULTIMATE
BA ULTIMATE POWER +
BA 200LTS BA 40LSS BA 60LSS BA 280LSS
Gear ratio 1:5 1:1 6:1 1:1
Color coding for gear ratio Red Blau Green Blue
Maximum motor speed in rpm 40000 40000 40000 40000
Maximum operating speed in rpm 200000 40000 6700 40000
Clamping system FG CA CA HP/CA
Internal cooling media x x x x
Back suction stop x x x x
6401553.book Seite 17 Montag, 13. Juni 2016 4:27 16

3Technical description Operating Instructions BA ULTIMATE POWER + / BA ULTIMATE
18 64 01 553 D3551.201.03.03.02
BA ULTIMATE
Light function x x x x
Instrument coupling INTRAmatic LUX®INTRAmatic LUX®INTRAmatic LUX®INTRAmatic LUX®
BA 200LTS BA 40LSS BA 60LSS BA 280LSS
BA 250LT BA 250T BA 45 LS BA 45S BA 65LS BA 65S
Gear ratio 1:5 1:5 1:1 1:1 6:1 6:1
Color coding for gear ratio Red Red Blue Blue Green Green
Maximum motor speed in rpm 40000 40000 40000 40000 40000 40000
Maximum operating speed in rpm 170000 170000 40000 40000 6700 6700
Clamping system FG FG CA CA CA CA
6401553.book Seite 18 Montag, 13. Juni 2016 4:27 16
This manual suits for next models
8
Table of contents
Languages:
Other B.A. International Medical Equipment manuals
Popular Medical Equipment manuals by other brands

Abbott
Abbott Amplatzer Trevisio 9-ATV06F45 Instructions for use

Top shelf Orthopedics
Top shelf Orthopedics Knee Sleeve Instructions for use

Bioness
Bioness L300 Go quick start guide

Duronic
Duronic OX01R manual

Topcon
Topcon CT-80 instruction manual

Dräger Medical
Dräger Medical Fabius GS Assembly and installation