manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. B-Link
  6. •
  7. Security Sensor
  8. •
  9. B-Link Detect–S User manual

B-Link Detect–S User manual

I. Specications
Instruccions DETECT-E
Detect – S is a new product adopting a microwave sensor with high frequency electromagnetic waves (5.8Ghz), gathering automatism,
convenience, safety and energy saving in a smaller size. As soon as someone enters its detection eld, Detect-S starts up almost instantly
identifying day and night cycles. Detect–S can detect trough doors, glass and thin walls.
Power Sourcing
Frequency
Detection Range
Detection distance
Ambient Light
Time-Delay
Load
Working temperature
Humidity
Power Consumption
Intalling height
Detection Motion speed
All responsibilities for defects or damages are hereby rejected, if caused by: Incorrect assembling
of the product; incorrect supply, use of lamps not suitable for this product; external agents. BLI_01.1_2017
All responsibilities for defects or damages are hereby rejected, if caused by: Incorrect assembling
of the product; incorrect supply, use of lamps not suitable for this product; external agents. BLI_01.1_2017
220-240 V/AC
50Hz
180º
5m - 15m (<24)
-20~+40
<93%RH
aprox.0.9W
0.6-1.5m/s
Min. 10seg. 3seg.
3-2000LUX (aj.)
Max. 12min. 2min.
300W
Max. 1200W
1-1,8m
±
±
Identify day and night automatically. Can adjust ambient light according to your desire: when turn to SUN (max), it will work in the daytime
and at night. When turn to MOON (min), it will only work under less than 3LUX circumstance. As for Adjustment, please refer to testing way.
Time-delay is added continually: when it receives the second induction signal after the rst inductor, it will compute time once more on
the rest of the rst time-delay basic (Set time).
Detect–S sensitivity can be set accordingly to your needs. If low sensitivity is needed, set the dial to 5 meters, otherwise turn the dial
to 15 meters.
Time-delay adjustment: it can be set according to your desire. The minimum is 10±3 sec; the maximum is 12±2min.
II. Function
NOTE: when testing in daylight, please turn LUX knob to SUN position, otherwise
the sensor lamp could not work!
IV. Test
Set the LUX knob clockwise until the SUN symbol is reached, then turn SENS knob clockwise until it reaches the + symbol
and turn the TIME knob anti-clockwise until the 10s is reached.
Connection Sketch (Figure 4):
Next switch on the power, if you followed the guide to this point it should start
working, the light will turn on immediately turning o after 10s +- 3 sec.
Should it receive a second signal amidst the rst cycle, the timer will add up, meaning
that the overall timer the bulb stays on will increase.
Turn LUX knob anti-clockwise on the minimum (3). If the ambient light is less than 3LUX
(darkness), the inductor load could work when it receives induction signal.
III. Installation
Turn o the power
Open Detect –S faceplate and adjust the Time and Lux knob.
Loosen the screws on the connection terminal and connect the power cables as shown in the diagram (gure 4).
Detect – S can be installed in circular or square sockets. For round sockets put it and spray bolt on both sides (Figure 2).
For square sockets x the screws through the mounting hole. (gure 3).
Put back the faceplate, and switch ON the power.
Reg nº 402030
www.blink.com.pt
Reg nº 402030
www.blink.com.pt
NOTA: The installation must be executed by a qualied professional, whom must follow these instructions rigorously.
Read these instructions carefully before using this product.
The High – Frequency output is lower than 0.2MW
Figure 1 Figure 2 Figure 3
All responsibilities for defects or damages are hereby rejected, if caused by: Incorrect assembling
of the product; incorrect supply, use of lamps not suitable for this product; external agents. BLI_01.1_2017
Should be installed by electrician or experienced man.
Avoid installing it on the unrest objects.
There shouldn’t be hindrance and moving object in front of the detection window eecting detection.
Considering your safety, please don’t open the cover when you nd the hitch after installation.
Avoid installing it near the metal and glass which may aect the sensor.
V. Note
The load don’t work:
Please check the power and load connect is correct.
Check if the load is good
VI. Some problem and solved way
Check if the working light corresponds to the ambient light
The sensitivity is poor:
Please check if there is hinder in front of the detection window to eect receiving the signals.
Please check if the signals source is in the detection elds.
Please check if the installation height corresponds to the height showed in the instruction.
The sensor can’t shut the load automatically:
Check if there are continual signals in the detection elds
Check if the time delay is set to the longest.
Check if the power corresponds to the instruction
Reg nº 402030
www.blink.com.pt

Other B-Link Security Sensor manuals

B-Link Focos User manual

B-Link

B-Link Focos User manual

B-Link PKP-1500-LI User manual

B-Link

B-Link PKP-1500-LI User manual

B-Link NANO SENSE User manual

B-Link

B-Link NANO SENSE User manual

B-Link SEMACONNECT 7 Series User manual

B-Link

B-Link SEMACONNECT 7 Series User manual

Popular Security Sensor manuals by other brands

ProVero ID-0055 Instruction

ProVero

ProVero ID-0055 Instruction

Innogy WMD instructions

Innogy

Innogy WMD instructions

brennenstuhl PIR 240 Directions for use

brennenstuhl

brennenstuhl PIR 240 Directions for use

Jaycar Electronics LA-5044 Installation and operating instructions

Jaycar Electronics

Jaycar Electronics LA-5044 Installation and operating instructions

Kimo DF 110 user manual

Kimo

Kimo DF 110 user manual

Lexing LX-PR-65S-Z instructions

Lexing

Lexing LX-PR-65S-Z instructions

Datalogic IO-Link S65-PA-5-M53 instruction manual

Datalogic

Datalogic IO-Link S65-PA-5-M53 instruction manual

CAME R Series manual

CAME

CAME R Series manual

SICK C4000 Select Addendum operating instructions

SICK

SICK C4000 Select Addendum operating instructions

Stanley IntelliLaser Pro user manual

Stanley

Stanley IntelliLaser Pro user manual

SICK Prime KTX-WP91142242 Series manual

SICK

SICK Prime KTX-WP91142242 Series manual

MEDC BGE Technical manual

MEDC

MEDC BGE Technical manual

brennenstuhl L801 IP 55 Directions for use

brennenstuhl

brennenstuhl L801 IP 55 Directions for use

System Sensor 5451EIS Installation and maintenance instructions

System Sensor

System Sensor 5451EIS Installation and maintenance instructions

ESL 260-CO Installation sheet

ESL

ESL 260-CO Installation sheet

ABB Stanilite Standard installation manual

ABB

ABB Stanilite Standard installation manual

Evolveo WiFi EYE manual

Evolveo

Evolveo WiFi EYE manual

PCB 2302-01A Installation and operating manual

PCB

PCB 2302-01A Installation and operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.