B.V.R BluRF User manual

BluRF
User manual
VER:V1.0

Dear user:
Thanks for using our company's products, in order to fully make use of
the products, we sincerely suggests follow:
◆◆Please read the instruction in detail and keep it well for further reading and
consulting.
◆◆Please follow the instruction to fit and operate the machine correctly.
◆◆Please do not remove and change any accessories of the machine.
◆◆It forbids others to open and remove the mainframe except the authorized
people in the company.
◆◆It forbids others to change and maintain the machine except the
professional people.
◆◆Please contact us if there is any trouble during operation.
Warning
This product does not belong to medical, please don’t use for disease treatment!

2
Parts Introduction
1
2.Power supply line jack
3.
4.Bipolar RF Vacuum work
handle jack
(eyes, face, body work handle
can be automatically
identified.)
5.Vacuum work handle public
side jack
6.Filter cup
.LCD screen
General power switch
Accessories
Bipolar RF vacuum
work handle for eyes
Bipolar RF vacuum
work handle for body
Bipolar RF vacuum
work handle for face
Blue LED
indicator light
RF work pieces
Accessory
1
2
3
54
6

3
5W
Basal Operation
1.
①Insert Bipolar RF vacuum work handle for eyes, face
and body to [4];
②While using Bipolar RF vacuum work handle for eyes,
face and body, please insert the transparent tube to [5];
2.Insert power supply line to [2], turn on the
[3], Input default password “000000”correctly, the
system will enter the interface as (Fig 1) shows.
3.The system automatically recognizes the work handle.
Put the accessories well and connect them to the host.
General power
switch
(Fig 1)
( )Fig 2
( )Fig 3
( )Fig 4
Body treatment
1.Click “ BODY ” as (Fig 1) shows, enter interface as (Fig 2).
2.Click “ ” to enter interface as (Fig 3) shows. Click “←”
and “→” to set work time , the range is : 1min~120min , 20
minutes for body treatment.
3.Click “Vacuum” to enter interface as (Fig 4) shows.
(1)Click “Mode” to set vacuum mode, Click “←” and “→”
to regulate, the range is : P1~P6.
(2)Click “Intensity” to set vacuum intensity, Click “←” and
“→” to regulate, the range is: 10kPa~80kPa.When it is
0kPa means that close the vacuum function.
4.Click “Bipolar RF” to enter interface as (Fig 5) shows.
Click “←” and “→” to regulate RF output intensity, the
range is :1(weak)~10(strength).When it is 0 means that
close the RF function.
5.Click “PDT” to open or close the blue indicator light.
6.Smear the essential oils in the treatment area, set work
time, vacuum mode, vacuum intensity and bipolar RF
intensity, Click “ ”,the machine start working.
7.The machine will pause automatically if the setting time is
over. Click “ ” to return to (Fig 1).
8.Clean the leftovers with hot towel, use warm towel to
clean the work head.
If there is
too much fat, you can increase the output intensity.

4
(Fig 5)
( )Fig 6
( )Fig 7
( )Fig 8
1.Click “ FACE ” as (Fig 1) shows, enter interface as (Fig 6).
2.Set work time, 20 minutes for face treatment.
3.Click “Vacuum” to set vacuum mode and intensity.
(1)Click “Mode” to set vacuum mode, the range is :
P1~P6.
(2)Click “Intensity” to set vacuum intensity, the range is :
10kPa~60kPa.
When it is 0kPa means that close the vacuum function.
4.Click “Bipolar RF” to regulate RF output intensity:
1(weak)~10(strength).When it is 0 means that close the
RF function.
5.Click “PDT” to open or close the blue indicator light.
6.Smear the essential oils on skin around face, Click “ ”,
the machine start working.
7.Beautican hold the handle and operating based on the
direction of the arrow in the picture. from inside to
outside, operating on both side, right and left, one side is
over then to start the other side, and must reduce the
intensity according to the less fat on forehead. if you want
to pause during using, please click “ ”.
NOTE :Do not let essential oils into eyes .
8.The machine will pause automatically if the setting time is
over.
9.Clean the leftovers with hot towel, use warm towel to
clean the work head.
Face treatment
Eyes treatment
1.Click “ FACE ” as (Fig 1) shows, enter interface as (Fig 7).
2.Set work time, 15 minutes for eyes treatment.
3.Click “Vacuum” to set vacuum mode and intensity.
(1)Click “Mode” to set vacuum mode, the range is:
P1~P6.
(2)Click “Intensity” to set vacuum intensity, the range is :
10kPa~50kPa. When it is 0kPa means that close the
vacuum function.
4.Click “Bipolar RF” to regulate RF output intensity:
1(weak) ~10(strength).When it is 0 means that close the
RF function.
5.Click “PDT” to open or close the blue indicator light.
6.Smear the essential oils on skin around eyes, Click “ ”,
the machine start working.
7.Beautican hold the handle and operating based on the
direction of the arrow in the picture. and must reduce the
intensity according to the less fat around eyes.
NOTE :Do not let essential oils into eyes .
8.The machine will pause automatically if the setting time is
over.
9.Clean the leftovers with hot towel, use warm towel to
clean the work head.

5
Caution for using RF
Others
Forbidden group
1.People with heart disease or high blood pressure, or configured cardiac pacemaker.
2.Patients with acute inflammation, asthma, deep vein thrombosis, thyroncus, cancer.
3.People with hemorrhagic disease, trauma or who is bleeding.
4.Pregnant women
5.Medical Plastic parts, or parts with artificial in filling inside.
6.People with metal inside the body(include metallic tooth)
7.Patient with skin inflammation or with edema.
8.People with an abnormal immune system.
9.Numb or insensitive to heat.
Click “set” as the(Fig 1) shows. Enter interface as (Fig 8):
Click“ basic setting ”,enter selecting language interface.
Notes “advanced setting” is for manufacturer only.
the
1.Need to oils or massage oil on the skin as convenient to move; for another, avoid the skin because
of dry and feel pain .
2.Adjust the vacuum suction depends on the strength of the guest, it should be determined by weak gradually
stronger
3.Do not operate on the wound skin .
4.
6.Clear the filter cup[6] after using.
Cleaning Methods:
Put some paper at the bottom of the filter cup, rise the valve with your fingers, let the liquid leak.
apply
The electrode probe must be fully in contact with skin.
5.Skin around eyes and forehead is very thin, the RF output intensity should be relatively weakened.

1.Host
2.Power supply line
3.User manual
4.Bipolar RF vacuum work handle for eyes
5.Bipolar RF vacuum work handle for face
6.Bipolar RF vacuum work handle for body
7.Accessory frame
8.Hexagonal screws
9.Hexagon wrench
10.Sealing ring
6
Technical parameters
Accessories list
AC220V/50Hz
1set
1pc
1copy
1pc
1pc
1pc
1pc
2pcs
1pc
15pcs
Input: AC110V/60Hz
Power:≤150VA
Output RF:2.45MHz
Table of contents
Popular Medical Equipment manuals by other brands

Essilor Instruments
Essilor Instruments APH 550 Maintenance manual

TekTone
TekTone Tek-CARE 500 Installation and operation manual

Braun
Braun Aesculap activ C Instructions for use/Technical description

Scienscope
Scienscope AXC-800 Operator's manual

Sedecal
Sedecal X Service manual

Invacare
Invacare 9610 user manual