Babycare TENS Obi TENS User manual

Obi TENS
Instructions for use
78
10 11
9
Using Your Obi TENS
a) You are now ready to start
using your Obi TENS.
Switch the unit on by
pressing the on/off button.
The Obi TENS will always
start up in BURST mode.
b) Begin by pressing the
Intensity Up key. Each
time you press this key, a
small ‘half-moon’ shape
will appear on the screen
increasing in number and
size as the intensity is
increased. You will begin
to feel a pulsating
sensation which will burst
in time with the ‘half-
moon’ shape as shown on
the LCD. You will feel this
sensation in both sets
of pads.
c) BURST (use between
contractions): This is the
first mode that you will
use. It feels like a bursting,
tingling sensation i.e. the
pulses are off and on
periodically. This mode
will help to promote those
all important natural pain-
killing chemicals known
as ‘endorphins’ and
‘enkephalins’.
d) BOOST (use during
contractions): When
experiencing a contraction,
simply press the ‘BOOST’
key. The Obi TENS will then
switch automatically into
the BOOST mode for that
extra surge of power
required to combat the
pain during contractions.
This will feel like a
continuous sensation.
e ) Once the contraction has
passed, simply press the
‘BOOST’ key. The Obi TENS
will return to the original
BURST mode. Continue
this cycle during your early
stages of labour.
Frequently Asked
Questions
QWhen shall I start using
my Obi TENS?
A Use as early as you can
after the onset of labour
to allow time for
your body’s pain-killing
chemicals to rise.
QCan I try the Obi TENS
before going into labour?
A Yes, place 2 pads on your
forearm to feel the
different pulse sensations
following the instructions
on page 6.
QCan I combine the Obi TENS
with other medication?
A Yes, you can still use
analgesics such as gas
and air (entinox) or
pethidine.
QCan the Obi TENS be
used in hospital?
A Yes. owever, a midwife
may ask you to switch it
off temporarily.
QCan I use the Obi TENS if
I am considering a water
birth?
A Yes, but not in the water
itself.
Troubleshooting
Questions
QWhy does the
stimulation not appear to
be as strong after you
have used the Obi TENS
for a while?
A Increase the intensity,
you may have become
used to a lower setting.
QWhy does the
stimulation feel strong
but ineffective?
A You may need to switch
off and reposition the
electrode pads.
QWhy does the
stimulation not feel
sufficiently strong even
on a high setting?
AThe batteries may need
replacing.
QWhat do I do if there is
no stimulation,
intermittent stimulation,
or weak stimulation felt
even with a new battery?
A Check electrode contact.
Check leads.
Check batteries.
Phone Babycare TENS
on 0845 230 9737.
0120
August 2012 (1)
Babycare TENS
108 George Lane, South Woodford,
London E18 1AD
Tel (+44) (0)20 8532 9595
Fax (+44) (0)20 8532 9551
www.babycaretens.com
e-mail customercare@babycaretens.com
ISO 9001:2008 ISO 13485:2003
EC DIRECTIVE 93/42/EEC Annex V
This manual is recyclable
Babycare TENS is part of the
Body Clock group of companies
TM
Selected Electrode
Placement Chart
The sticky electrode pads
need to be placed in the
correct position for
maximum pain relief.
It is preferable to obtain
assistance from either your
birthing partner or medical
adviser when positioning
the pads. Please read the
following instructions
carefully:
1. Carefully peel all of the
pads from the plastic
backing using your
forefinger and thumb. Do
not pull on the lead wires.
2. Position the top pads
(connected to the mauve
coloured leads)
approximately 4cm either
side of the spine and 4-
5cm above the imaginary
navel line as seen in the
diagram.
3. Position the bottom two
pads (connected to the
white coloured leads)
approximately 4cm either
side of the spine and 4-
5cm below the imaginary
navel line as seen in the
diagram. NB. It makes no
difference whatsoever
whether the mauve pads
are at the top and the
white ones are below or
vice versa, as long as they
are in horizontal pairs.
In line
with
navel
Reference: Cluett E. (1994) SRN RM ADM PGCEA.
Analgesia in Labour: A review of the TENS method.
Professional Care of Mother and Child. Mar;4 (2): 50-2.
Bra
Line
Panty
Line
Before first use of the Obi TENS, please
familiarise yourself with the precautions and
contraindications contained on page 1 and 2.
Useful Information
1. Continue stimulation for
as long as necessary,
unless you experience
discomfort.
2. If you stimulate for a
number of hours ensure
the pads do not become
dry. If this occurs, switch
off the unit, disconnect
the electrodes, and apply
a small drop of water to
them.
3. Always ensure that the
unit is switched off
before you remove all the
leads and pads. Do not
pull the wires. ALWAYS
remove the jack plugs
from their sockets by
holding the plugs
between the forefinger
and thumb.
4. The Obi TENS can also be
used as a standard TENS
unit for relief of
numerous conditions,
including after pains and
post operative pains. It is
worth bearing this in
mind if you have a
caesarean section. Please
seek medical advice first.
KEY: =first pair of electrodes =second pair of electrodes.
N.B. Electrodes supplied with this unit are all the same colour -
the black and white squares show suggested electrode
placement only.
Shoulder Pain and
Frozen Shoulder
Outer and inner
aspect of shoulder
Period Pain Classical Migraine
Lower Back Pain
Technical Data
Display The LCD has a total of 13 display segments.
The array of Level Bars consists of 10 LCD Level
Bar. In addition, 2 individual LCD segments
respectively indicate the Modes (i.e. Burst and
Boost). The last LCD segment is used to
illuminate the low battery indicator.
Mode 2 operation modes
Pulse ( z)
Frequency
Pulse
Width (µs)
Pattern
32 200 2 bursts per
second and 8
pulses per burst
80 100 Constant pulse
Output Channel ONE Channel
Output oltage 0 – 100V (zero-to-peak) across
a 500Ω load; adjustable in 10 steps
Output Intensity 200mA (max.) into a 500Ω load
Output Waveform Symmetrical Mono-phasic rectangular
Output Jacks CE Touch-proof jacks
Battery 2 X1.5V AAA Battery (Type LR03)
Battery Low Detect 2.2V±0.1V
Tolerances All output parameters are subjected
to a ±10% tolerance unless other specified
12
Burst
Boost
Ob TENSInstruct ons_A4_LA.qx8_(v) 02/01/2014 12:00 Page 1

How Will The Obi
TENS Help Your Pain?
TENS (Transcutaneous
Electrical Nerve Stimulation)
works by passing mild
electrical impulses through
the skin, via electrode pads,
into the nerve fibres which
lie below. The TENS
impulses help your body
produce its own pain killing
chemicals, such as
‘endorphins’ and
‘encephalins’.
The level of pain relief
obtained from the Obi TENS
varies from person to
person. Some find that the
Obi TENS provides all the
pain relief required during
the whole of labour,
whereas others find that
other analgesics are also
needed during the later
stages of labour.
Precautions And
contraindications
1. Do NOT use the Obi
TENS if you have a
cardiac pacemaker.
2. Check with your medical
adviser before using if
you suffer from a heart
condition, epilepsy,
undiagnosed pain, have
any metal implants, or
any doubts whatsoever.
3. TENS must NOT be used
before the 37th week
of pregnancy.
4. Never use TENS to mask
undiagnosed pain since
this could require urgent
treatment.
5. If you are pregnant, do
NOT place the
electrodes over your
abdomen.
Contents
ow Will The Obi TENS elp Your Pain?.................................. 1
Precautions And Contraindications ........................................ 1
The Obi TENS Controls .......................................................... 3
Additional Functions.............................................................. 4
Setting Up Your Obi TENS ...................................................... 5
Suggested Pad Placement Chart .......................................... 7
Using Your Obi TENS.............................................................. 8
Frequently Asked Questions .................................................. 9
Troubleshooting Questions .................................................. 9
Useful Information .............................................................. 10
Post-Natal Pad Placement Diagrams .................................... 11
Technical Data...................................................................... 12
1 2
3 4 5 6
General Precautions
1. Do NOT use this unit
without first reading
these instructions.
2. Do NOT immerse the Obi
TENS in any liquid.
3. Do NOT place it close to
any source of excessive
heat or operate it in the
presence of flammable
gas.
4. Do NOT drop this unit
onto a hard surface.
5. Do NOT attempt to
dismantle the Obi TENS.
7. Only use specified
batteries and electrodes.
8. If damaged, do not use.
Return to supplier.
9. Remove the batteries
when not in use.
10. Do NOT use while driving
or operating potentially
dangerous machinery or
while using a microwave.
11. Keep out of the reach of
children.
12. Do NOT place electrodes
on or near the eyes, in
the mouth, over the front
or sides of the neck,
across the head, heart,
or an area of broken,
inflamed, infected or
numb skin. Electrodes
should generally only be
applied to skin with
normal sensation unless
under medical
supervision.
13. Do NOT use in the
presence of tuberculosis,
malignant tumours, very
high or very low blood
pressure, high fever or
acute inflammatory
disease unless under
medical supervision.
14. A mild shock may be
caused if one electrode is
accidentally removed. In
the event of this
happening the unit
should be turned off
immediately.
Controls On The Obi TENS
Low Battery Indicator -
A flashing battery symbol
will be shown on the display.
Automatic Power Off -
When the unit intensity
levels are zero, and the Obi
TENS has not been in use
for about 5 minutes, the unit
will shut off automatically.
Setting Up Your
Obi TENS
Check you have the
following contents:
• 1 x Obi TENS unit
• 1 x Pack of 4 self
adhesive electrodes
(40mm x 100mm)
• 1 x Leadwires
• 2 x AAA batteries
• 1 x Carrying pouch
• 1 x Easy-release
neck cord
• 1 x Instruction
manual
The Assembly Stage
1. Slide open the battery
cover on the back of the
unit to expose the
battery compartment.
2. Insert 2 x AAA batteries
according to the diagram
found in the battery
compartment. Replace
the cover. Please ensure
your unit is switched off.
a) Take one of the mauve
and white leadwires and
insert the white jack plug
at the end of the lead
into the socket at the
bottom of the Obi TENS
unit.
POWER Key – Turns the Obi TENS On and Off.
User display – Indicates the mode in use and the intensity
level. (also see diagram below).
BOOST Key –Used for extra surge during contractions.
Intensity Up – Increases the intensity of the pulses.
Intensity Down – Decreases the intensity of the pulses.
BURST -
This function is used
at the onset of labour
and in-between
contractions.
Power Bar -
This indicates the
intensity of the pulses
from 0 to 10 for both
sets of pads.
BOOST -
This mode is
used during
contractions.
Low Battery
Indicator.
User Display
Additional Functions
b) Now insert the red and
white pins (at the other
end of the leadwire) into
the sockets attached to
all of the sticky
electrodes. You will see
that the lead wire is
made up of 4 wires; 2
mauve and 2 white. Do
not remove the
electrodes from the
backing at this stage (see
figure). NB. Each
leadwire has
a red and white pin at
the end. It makes NO
difference whatsoever
which electrode they are
attached to!
c) If you wish, attach the
easy-release neck cord
which enables you to
hang the Obi TENS from
your neck whilst in labour.
Insert a red and white pin
(at the end of the lead wire)
into each pair of electrodes.
The Obi TENS is an ultra simple yet powerful
obstetric TENS unit perfect for drug-free pain relief
during labour. It has 2 pre-set modes; one for use
during contractions, the other for use between
contractions.
TENS is recognised as a safe and highly effective method of pain relief
and is regularly recommended by medical professionals.
TENS is a drug free method of pain relief, with no known side effects,
which can also be used in conjunction with any additional medication
if required.
Explanation Of Symbols On Unit
Equipment providing a particular degree of protection
against electric shock particularly regarding allowable
leakage currents having a BF type (floating) applied part.
Warning – refer to accompanying documents i.e. these
instructions.
Denotes a product which must be disposed of safely.
Ob TENSInstruct ons_A4_LA.qx8_(v) 02/01/2014 12:00 Page 2
Other manuals for Obi TENS
2
Other Babycare TENS Medical Equipment manuals
Popular Medical Equipment manuals by other brands

Partial Hand Solutions
Partial Hand Solutions Partial M-Finger Technical instructions

VOCO
VOCO x-tra base Instructions for use

identités
identités 823100 instruction manual

laerdal
laerdal EXTRI KELLY Directions for use

Moog
Moog Infinity Orange Quick reference instructions

Amico
Amico Majestic Series installation instructions

Ultimate Healthcare
Ultimate Healthcare Heritage II Bariatric user manual

Beurer
Beurer SI 30 Instructions for use

Omron
Omron H-CR24 Instructions for use

Tuttnauer
Tuttnauer Elara11 Quick installation guide

Respironics
Respironics Millennium H600 Service and technical reference guide

NycoCard