manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Bahamas Breeze
  6. •
  7. Fan
  8. •
  9. Bahamas Breeze FW40-F3 User manual

Bahamas Breeze FW40-F3 User manual

Other Bahamas Breeze Fan manuals

Bahamas Breeze FS45-3ER User manual

Bahamas Breeze

Bahamas Breeze FS45-3ER User manual

Popular Fan manuals by other brands

Minka Group minkaAire Wave F843 instruction manual

Minka Group

Minka Group minkaAire Wave F843 instruction manual

Airflow Adroit DV50 instruction manual

Airflow

Airflow Adroit DV50 instruction manual

Vornado 270 Series owner's guide

Vornado

Vornado 270 Series owner's guide

comfort air TH-10D instruction manual

comfort air

comfort air TH-10D instruction manual

Livoo DOM386 instruction manual

Livoo

Livoo DOM386 instruction manual

Holmes BLIZZARD HAOF-90 owner's guide

Holmes

Holmes BLIZZARD HAOF-90 owner's guide

Taurus GRECO 16 ELEGANCE manual

Taurus

Taurus GRECO 16 ELEGANCE manual

Quorum PINNACLE installation instructions

Quorum

Quorum PINNACLE installation instructions

Monte Carlo Fan Company 3DIR58RBD-V1 Owner's guide and installation manual

Monte Carlo Fan Company

Monte Carlo Fan Company 3DIR58RBD-V1 Owner's guide and installation manual

Craftmade UH52 installation guide

Craftmade

Craftmade UH52 installation guide

Jocel JVA030658 instruction manual

Jocel

Jocel JVA030658 instruction manual

MIKA MFB1211/GR user manual

MIKA

MIKA MFB1211/GR user manual

Harbor Breeze RLG52NWZ5L manual

Harbor Breeze

Harbor Breeze RLG52NWZ5L manual

Allen + Roth L1405 instruction manual

Allen + Roth

Allen + Roth L1405 instruction manual

ViM KUBAIR F400 ECOWATT Technical manual

ViM

ViM KUBAIR F400 ECOWATT Technical manual

HIDRIA R10R-56LPS-ES50B-04C10 user guide

HIDRIA

HIDRIA R10R-56LPS-ES50B-04C10 user guide

BLAUBERG Ventilatoren CENTRO-M 100 L user manual

BLAUBERG Ventilatoren

BLAUBERG Ventilatoren CENTRO-M 100 L user manual

Triangle Engineering HEAT BUSTER SPL Series owner's manual

Triangle Engineering

Triangle Engineering HEAT BUSTER SPL Series owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

3 SPEED WALL FAN
READ AND SAVE THESE INSTRUCTIONS
MODEL:FW40-F3
OWNER’S MANUAL
PRINTED IN CHINA
CAUTION
Read and follow all instructions before operating fan. Do not use fan if any
part are damaged or missing.
WARNING
1. This appliance is not intended for use by young children or infirm persons
without supervision.
2. Young children should be supervised to ensure that they do not play with
the appliance.
3. This appliance has a polarized plug (one blade is wider than the other).
To reduce the risk of electrical shock, this plug is intended to fit in a
polarized outlet only one way. If the plug does not fit fully into the outlet,
reverse the plug. If the plug still does not fit, contact a qualified electrician.
Do not attempt to bypass this safety feature.
4. If the supply cord is damaged ,it must be replaced by manufacturer or its
service agent or a similarly qualified person in order to avoid a hazard.
5. To reduce the risk of fire or electrical shock, do no use this fan with any
solid state speed control device.
6. Changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
(2) Do not operate any fan with a damaged cord or plug. Discard or return
the fan to an authorized service facility for examination and/or repair.
(3) Do not run cord under carpeting. Do not cover cord with throw rugs,
runners, or similar coverings. Do not route cord under furniture or
appliances. Arrange cord away from traffic area and where it will not
be tripped over.
RULES FOR SAFE OPERATION
1. Never insert fingers, pencils, or any other object through the housing when
the fan is running. Disconnect it when moving from one location to
another.
2. Disconnect fan when moving from one location to another.
3. Disconnect fan when removing grilles for cleaning.
4. Do not leave the fan running unattended.
5. Be sure the fan is on a stable, flat surface when in operation.
6. The rules about cords and plugs are as follows:
(1) This product uses overload protection (fuse). A blown fuse indicates
an overload or short-circuit situation. If the fuse burns out, unplug the
product from the outlet. Replace the fuse as per the user servicing
instructions (follow product marking for proper fuse rating) and check
the products. If the replacement fuse blows, a short-circuit may be
present and the product should be discarded or returned to an
authorized service facility for examination and/or repair.
PARTS NAME
1 2
GUARD & FAN BLADE ASSEMBLY
1. Unscrew the spinner clockwise (or take the spinner out from the bag) and
the plastic nut counter clockwise to remove both of them. Fix the rear
guard to the motor then tighten the plastic nut again. (Fig. 1)
2. Discard PVC sleeve on shaft. Insert the blade into shaft, and make sure
the rotor shaft pin is fitted into groove of the blade. Turn the spinner
counter clockwise to tighten the blade. (Fig. 2)
3. Fasten the front guard and the rear guard by the guard clip(Fig. 3)
Clip
Fig.1 Fig.2 Fig.3
INSTALLATION
The fan should be installed on a solid wooden or
pillar, which stands vertically to the floor.
Caution: To prevent the fan from falling off, do not
install it on walls less then 10 cm thick or made of
materials that are easily damaged.
Installing the mounting bracket
Fix the supplied mounting bracket firmly to the wall
using the three screws.
NOTE: The bracket should be positioned at least
35 cm from the ceiling and at least 30 cm from
adjoining wall.
Installing the stand
Mount the stand on the bracket by inserting the
bracket catch into the slot on the stand.
Fix the stand onto the bracket with a retaining nut.
NOTE: If the retaining nut does not pass through the
holes, push the stand downwards until it is fully
mounted on the bracket.
3 4
SPEED ADJUSTMENT
Adjust to the desired speed by pulling the pull switch (A).
0---Stop 1---Low 2---Medium 3---High
OSCILLATION CONTROL
Adjust the position of the oscillation by pulling the pull
switch (B).
Push the guard lightly to the desired up or down direction.
CLEANING
1. Be sure to unplug from the electrical supply source before cleaning.
2. Plastic parts should be cleaned with mild soap and damp cloth or
sponge. Thoroughly remove soap film with clean water.
3. Be sure not to make water or other liquid enter the inside of the motor.
USER SERVICING INSTRUCTIONS
1. Grasp the plug and remove it from the receptacle
or other outlet device. Do not unplug by pulling
on the cord.
2. Open the fuse cover. Slide opens the fuse access
cover on top of attachment plug towards blades.
3. Remove the fuse carefully. Push the fuse from the other side or turn the
fuse holder over to remove the fuse.
4. Risk of fire. Replace the fuse only with 2.5 A, 125 Volt fuse.
5. Close the fuse cover. Slide closed the fuse access cover on top of the
attachment plug.
6. Risk of fire. Do not replace attachment plug. Contains a safety device
(fuse) that should not be removed. Discard product if the attachment plug
is damaged.
NOTICE:
1. When you replace fuse, please don’t operate suddenly or overexert, or
else the product will be damage or cause accident.
2. When you feel it hard to be operated, please make sure you have got the
right way.
5
SERVICE & SUPPORT
If service is required for this fan, please contact us at the following:
Toll Free: 866-876-4332 Email us at: [email protected]
For questions or comments, please write to:
Customer Service
1937 North Great Southwest Parkway, Grand Prairie, TX 75050, USA
For your records, staple your sales receipt to this manual and record the following:
DATE OF PURCHASE:
PLACE OF PURCHASE:
(STAPLE SALES RECEIPT HERE)
NOTE: PROOF OF PURCHASE IS REQUIRED FOR ALL WARRANTY CLAIMS