2 | BHGE ® 2017 Baker Hughes, a GE company. All rights reserved.
Table of Contents
GENERAL ..................................................................................... 3
SPARE PARTS..................................................................................... 3
AFTER SALES SUPPORT.................................................................... 3
TRAINING ..................................................................................... 3
1. DESCRIPTION - OPERATION...................................................... 4
1.1. PRINCIPLE OF OPERATION..........................................................................4
1.2. SIGNAL PROCESSING ..................................................................................4
2. PROTECTION STANDARDS ........................................................ 5
2.1. ATEX /IECEX CERTIFICATIONS ...............................................................5
2.2. FM /FMC CERTIFICATIONS ......................................................................6
2.2.1. GENERAL REQUIREMENTS ....................................................................6
2.2.2. FLAMEPROOF AND DUST IGNITION PROOF REQUIREMENTS ................6
2.2.3. INTRINSICALLY SAFE REQUIREMENTS ...................................................6
2.2.4. DESCRIPTION OF EXPLOSION PROOF AND INTRINSIC SAFETY
MARKING................................................................................................7
2.2.5. REPAIR ...................................................................................................8
2.2.6. ES-749 INTRINSICALLY SAFE INSTALLATION WIRING
REQUIREMENTS......................................................................................9
2.2.7. NOTES FOR INTRINSICALLY SAFE INSTALLATION............................... 10
3. MARKING –NUMBERING SYSTEM .......................................... 12
3.1. MARKING................................................................................ 12
3.2. NUMBERING SYSTEM ................................................................ 12
4. INSTALLATION........................................................................... 13
4.1. STORAGE AND CONDITIONS AT DELIVERY ................................... 13
4.2. MOUNTING ON SITE ................................................................. 13
4.2.1. EXTERNAL MOUNTING ....................................................................................... 13
4.2.2. INTERNAL MOUNTING ........................................................................................ 14
5. CASE DESCRIPTION .................................................................. 15
5.1. ELECTRONIC COMPARTMENT .................................................... 15
5.2. MECHANISM COMPARTMENT .................................................... 15
5.3. MTBF.................................................................................... 15
5.4. CONNECTION COMPARTMENT ................................................... 15
5.4.1. ELECTRIC CIRCUIT............................................................................................... 15
5.4.2. WIRING AND CONNECTIONS ............................................................................ 16
5.4.3. ALLOWABLE SUPPLY VOLTAGES....................................................................... 16
5.4.4. MAXIMUM POWER ............................................................................................. 16
5.4.5. OUTPUT SIGNAL AND LOAD RESISTANCE ....................................................... 16
6. OPERATING THE INSTRUMENT ............................................... 19
6.1. GENERAL PRINCIPLES ............................................................... 19
6.1.1. THE LIQUID CRYSTAL DISPLAY (LCD)............................................................... 19
6.1.2. PUSHBUTTONS ................................................................................................... 19
6.1.3. OPERATING MODES............................................................................................ 19
6.1.4. PUSHBUTTONS MENUS DESCRIPTION ............................................................. 20
7. COMMISSIONING ...................................................................... 22
7.1. INSTRUMENT COUPLING TO THE TORQUE TUBE ........................... 22
7.2. TRANSMITTER CONFIGURATION ................................................. 24
7.3. TRANSMITTER CALIBRATION...................................................... 25
7.3.1. OPERATING RULES AND CALIBRATION PRINCIPLE....................... 26
7.3.2. CALIBRATION AT WORKSHOP WITH WEIGHTS.............................. 29
7.3.3. CALIBRATION ON SITE WITH PROCESS FLUIDS .............................................. 31
7.3.4. CALIBRATION WITH MECHANICAL STOPS ....................................................... 32
7.4. CALIBRATION OF SPECIFIC GRAVITY METER ................................. 34
7.5. MECHANICAL STOPS SETTING .................................................... 35
7.6. TORQUE TUBE TEMPERATURE COMPENSATION ............................ 37
7.7. CONTROLLER FUNCTION (12410 MODEL ONLY) ......................... 39
8. SAFETY MANUAL FOR SIL APPLICATIONS .............................45
8.1. RELEVANT STANDARDS.............................................................45
8.2. TERMS AND DEFINITIONS ..........................................................45
8.3. SAFETY REQUIREMENTS ............................................................46
8.3.1. PROBABILITY OF FAILURES ON DEMAND (PFD) .............................................46
8.3.2. SAFETY INTEGRITY OF THE HARDWARE ...........................................................46
8.4. SAFETY CHARACTERISTICS .........................................................46
8.4.1. ASSUMPTIONS.....................................................................................................46
8.4.2. SAFETY INTEGRITY OF THE HARDWARE ...........................................................47
8.4.3. HARDWARE LOCK JUMPER ADJUSTMENT.......................................................47
8.4.4. CHARACTERISTICS ..............................................................................................47
8.5. SAFETY FUNCTION....................................................................48
8.6. PROOF TEST ............................................................................48
9. MAINTENANCE ..........................................................................49
9.1. REMOVAL OF 12400 CASE FROM TORQUE TUBE .........................49
9.2. INSTALLATION OF 12400 CASE ON A TORQUE TUBE ....................49
9.2.1. ON A 12200/300/400 SERIES TORQUE TUBE ..........................................49
9.2.2. ON A 12120 OR 12800 SERIES TORQUE TUBE...........................................50
9.3. REMOVAL OF 12400 CASE AND TORQUE TUBE S/A......................51
9.4. MOUNTING OF DLT CASE AND TORQUE TUBE S/A.........................52
9.5. REVERSE INSTRUMENT CASE MOUNTING POSITION VERSUS TO
DISPLACER POSITION (LEFT OR RIGHT)........................................53
9.6. REPLACEMENT OF ELEC.AND MECH.COMPONENTS .....................53
10 TROUBLE SHOOTING................................................................54
10.1. NO SIGNAL ...........................................................................54
10.2. EXISTING SIGNAL BUT NOTHING ON LCD DISPLAY ......................54
10.3. STEADY SIGNAL,NO CHANGE WHEN LEVEL VARIES.....................54
10.4. OUTPUT SIGNAL DIFFERS FROM VALUE DISPLAYED ON LCD ........54
10.5. NO HART®COMMUNICATION................................................55
10.6. OUTPUT SIGNAL DOES NOT MATCH WITH THE LIQUID LEVEL
(LINEARITY ISSUE) ....................................................................55
10.7. VIEW ERROR DIAGNOSTICS MESSAGES ......................................56
Appendix A –NORMAL Menu / SETUP Menu .................. 61 to 62
Appendix B –BASIC SETUP Menu ..................................... 63 to 65
Appendix C –ADVANCED SETUP Menu .......................... 66 to 69
Appendix D –ENGINEERING UNIT Menu......................... 70 to 72
Appendix E –4-20mA GENERATOR Menu....................... 73 to 74
Appendix F –VIEW DATA Menu ........................................ 75 to 76
Appendix G –FAILSAFE / VIEW ERROR Menus............... 77 to 78