Warm Cool Mode/Prog Jets Blower LightTime
http://www.balboawatergroup.com/
Temp Control (80°F - 104°F / 26.0°C - 40.0°C)
The last measured water temperature is constantly displayed.
The water temperature displayed is current only when the
pump has been running for at least 2 minutes.
To display the set temperature, press “Warm” or “Cool” once. To
change the set temp, press a temp button again before the display
stops flashing. After three seconds, the display will stop flashing
and begin to display the current spa temperature.
Jets 1
Press “Jets 1” to turn pump 1 on or off, and to shift between low
and high speeds (if equipped). The low-speed will turn off after
4 hours. High-speed will turn off after 15 minutes. Low-speed
may run automatically at times, during which it cannot be
deactivated from the panel, but high-speed may be operated.
Jets 2/Jets 3/Blower (If equipped)
Press the corresponding button once to turn the device on or
off. The device will turn off after 15 minutes. Pump 2 may be
two-speed on some systems.
If the panel has a button with 2 devices assigned to it, like Pump
2 and Pump 3, press the button repeatedly to step through the
various combinations of On and Off for both devices.
Light
Press “Light” to operate the spa light. Turns off after 4 hours.
Setting the Time of Day
When the spa is first powered up, the words SET TIME will flash
on the display. Press “Time,” then “Mode/Prog,” then “Warm” or
“Cool.” The time will begin changing in one-minute increments.
Press “Warm” or “Cool” to stop the time from changing. Press
“Time” to confirm.
Initial Start-up
Your spa will enter Priming Mode ( ) when it is energized.
During Priming Mode, press “Jets” button(s) repeatedly and
be sure all pumps are free of air. Priming Mode lasts less than
5 minutes. Press “Warm” or “Cool” to exit. After Priming Mode,
the spa will run in Standard Mode (see Mode/Prog section).
Button shapes and labels may vary.
Balboa 500DZ-Series Operation Guide
This document covers VS and GS systems 500DZ through 520DZ with Balboa Panels VL801D or VL802D.
Mode/Prog
Mode is changed by pressing “Warm” or “Cool,” then pressing
“Mode/Prog” button.
Standard Mode maintains set temperature and the STANDARD icon
will be displayed.
Economy Mode heats the spa to the set temperature only during
filter cycles. will display when water temp is not current, and
will alternate with water temp when the pump is running. The
ECONOMY icon will be displayed.
Sleep Mode heats the spa to within 20°F/10°C of the set
temperature only during filter cycles. will display when water
temp is not current, and will alternate with current water temp
when the pump is running.
Preset Filter Cycles
The first preset filter cycle starts at 8:00 AM and ends at
10:00 AM. The second preset filter cycle starts at 8:00 PM and
ends at 10:00 PM.
For non-circ systems, low-speed pump 1 and the ozone generator
(if installed) run during filtration.
For 24 hour circulation systems, the circ pump and the ozone
generator (if installed) run 24 hours. In hot environments, the
circ pump may turn off for 30 minute periods, except during
filter cycles.
For non-24 hour circulation systems, the circ pump and ozone
generator (if installed) run during filtration (and may also run
automatically at other times).
At the beginning of each filter cycle all other equipment will
run briefly to purge the plumbing.
Optional Filter Cycle Programming
You are not required to change the filter cycles, but if you wish
to, press “Time,” “Mode/Prog,” “Mode/Prog” within 3 seconds.
SET START FILTER 1 (AM) will appear. Press “Warm” or “Cool” to
reset the filter start time.
Press “Mode/Prog” to see SET STOP FILTER 1 and adjust the time
with “Warm” or “Cool” as done above. Press “Mode/Prog” to see
SET START FILTER 2 (PM) and proceed as above. Press “Mode/Prog”
to see SET STOP FILTER 2 and proceed as above. Press “Mode/Prog”
to confirm.
The pump responsible for heating and filtration (pump 1 low-speed
on non-circ system, or the circ pump on circ systems) will be
referred to simply as the pump.
In multi-button sequences, if the buttons are pressed too quickly in
the sequence, they may not register.
P/N 40788_F 07/27/2010
Warning! Shock Hazard! No User Serviceable Parts.
Do not attempt service of this control system. Contact your dealer or service organization for assistance.
Follow all owner’s manual power connection instructions. Installation must be performed by a licensed
electrician and all grounding connections must be properly installed.
No message on display.
Power has been cut off to the spa.
Temperature unknown.
“Overheat” - The spa has shut down.* One of the
sensors has detected 118°F/47.8°C at the heater.
“Overheat” - The spa has shut down.* One of
the sensors has detected that the spa water is
110°F/43.5°C.
Spa is shut down.* The sensor that is plugged
into the Sensor “A” jack is not working.
Spa is shut down.* The sensor that is plugged
into the Sensor “B” jack is not working.
Sensors are out of balance. If alternating with
spa temperature, it may just be a temporary
condition. If flashing by itself, spa is
shut down.*
A significant difference between temperature
sensors has been detected. This could indicate a
flow problem.
Persistent low flow problems. (Displays on the
fifth occurrence of message within
24 hours.) Heater is shut down, but other spa
functions continue to run normally.
Possible inadequate water, poor flow, or air
bubbles in detected in the heater. Spa is shut
down for 15 minutes.
Inadequate water detected in heater. (Displays on
third occurrence of message.) Spa is
shut down.*
“Ice” - Potential freeze condition detected.
* - Even when spa is shut down, some equipment will
turn on if freeze protection is needed.
Message
Meaning Action Required
Diagnostic Messages
The control panel will be disabled until power returns. Spa settings will
be preserved until next power up.
After the pump has been running for 2 minutes, the current water
temperature will be displayed.
DO NOT ENTER THE WATER. Remove the spa cover and allow
water to cool. Once the heater has cooled, reset by pushing any button.
If spa does not reset, shut off the power to the spa and call your dealer or
service organization.
DO NOT ENTER THE WATER. Remove the spa cover and allow
water to cool. At 107°F/41.7°C, the spa should automatically reset. If
spa does not reset, shut off the power to the spa and call your dealer or
service organization.
If the problem persists, contact your dealer or service organization.
(May appear temporarily in an overheat condition).
If the problem persists, contact your dealer or service organization.
(May appear temporarily in an overheat condition).
If the problem persists, contact your dealer or service organization.
If the water level is normal, make sure all pumps have been primed. If
problem persists, contact your dealer or service organization.
Follow action required for message. Heating capability of the spa will
not reset automatically; you may press any button to reset.
If water level is normal, make sure all pumps have been primed. Press any
button to reset. This message will reset within 15 minutes. If problem
persists, contact your dealer or service organization.
Follow action required for message. Spa will not automatically reset.
Press any button to reset manually.
No action required. All equipment will automatically activate regardless
of spa status. The equipment stays on 4 minutes after the sensors
detect that the spa temperature has risen to 45°F/7.2°C or higher. An
optional freeze sensor may be added to protect against extraordinary
freeze conditions. Auxiliary freeze sensor protection is advisable is colder
climates. See your dealer for details.
Locking the Panel
Press “Time,” “Blower,” and “Warm” within 3 seconds. The
Panel is now locked.
To unlock the panel, press the “Time,” “Blower,” and “Cool”
within 2 seconds.
Locking the Temperature
Press “Warm,” “Time,” “Blower,” and “Warm” within 3 seconds. The
“Warm” and “Cool” buttons are now disabled.
To unlock the temperature, press “Time,” “Blower,” and “Cool” within
2 seconds.
Note: On some systems, “Jets 1,” instead of “Blower,” is used in Lock/Unlock sequences.

Other Balboa Water Group Hot Tub manuals

Balboa Water Group TP600 User manual

Balboa Water Group

Balboa Water Group TP600 User manual

Balboa Water Group 59340-01 User manual

Balboa Water Group

Balboa Water Group 59340-01 User manual

Balboa Water Group 512Z User manual

Balboa Water Group

Balboa Water Group 512Z User manual

Balboa Water Group 500DZ Series User manual

Balboa Water Group

Balboa Water Group 500DZ Series User manual

Balboa Water Group Swim Pro User manual

Balboa Water Group

Balboa Water Group Swim Pro User manual

Balboa Water Group 500Z Series User manual

Balboa Water Group

Balboa Water Group 500Z Series User manual

Balboa Water Group 500SZ-Series User manual

Balboa Water Group

Balboa Water Group 500SZ-Series User manual

Balboa Water Group 500DZ Series User manual

Balboa Water Group

Balboa Water Group 500DZ Series User manual

Popular Hot Tub manuals by other brands

Coast Spas Patio Series owner's manual

Coast Spas

Coast Spas Patio Series owner's manual

KBL megaSun 5600 operating instructions

KBL

KBL megaSun 5600 operating instructions

Jacuzzi J - 200 J - 230 owner's manual

Jacuzzi

Jacuzzi J - 200 J - 230 owner's manual

Saturn ST-BC7308 quick start guide

Saturn

Saturn ST-BC7308 quick start guide

UNIPRODO UNI POOLS 20 user manual

UNIPRODO

UNIPRODO UNI POOLS 20 user manual

LAZBOY Revive owner's manual

LAZBOY

LAZBOY Revive owner's manual

Aquatic LUXEAIR 28 ai28lux7236 Specification sheet

Aquatic

Aquatic LUXEAIR 28 ai28lux7236 Specification sheet

BullFrog I 331 Series owner's manual

BullFrog

BullFrog I 331 Series owner's manual

Jacuzzi DESIGNER BATH SERIES Installation & operation instructions

Jacuzzi

Jacuzzi DESIGNER BATH SERIES Installation & operation instructions

KIRAMI CUBE user manual

KIRAMI

KIRAMI CUBE user manual

Medisana WBM manual

Medisana

Medisana WBM manual

Image IMSB53950 user manual

Image

Image IMSB53950 user manual

EcoSmarte Swim Spa Installing

EcoSmarte

EcoSmarte Swim Spa Installing

Sanotechnik F10100 user manual

Sanotechnik

Sanotechnik F10100 user manual

Jacuzzi J-300 Series Installation manual and use & maintenance

Jacuzzi

Jacuzzi J-300 Series Installation manual and use & maintenance

Roca BROADWAY COMPACT Users handbooks

Roca

Roca BROADWAY COMPACT Users handbooks

Teuco 640 Assembly instructions

Teuco

Teuco 640 Assembly instructions

Jacuzzi SKYLINE 190 Use & maintenance

Jacuzzi

Jacuzzi SKYLINE 190 Use & maintenance

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.