User Manual
Inductive Positioning System BIP ED2-BXXX-03-S75
No. 880454 EN A16
3
Sensor lengths L with corresponding working range Sa
max.
Part designation
BIP ED2-B048-03-S75
BIP ED2-B070-03-S75
BIP ED2-B103-03-S75
BIP ED2-B133-03-S75
Connector diagram
1 16…30 V DC (+Ub)
2 4…20 mA
3 0 V (GND)
4 0…10 V
Wiring diagram
Programming
The sensor is set at the factory to the maximum detection
range Sa max. It is possible to program the respective
start and end points of the measuring range as needed.
The start and end points must be at least Samax/2 from
one another in this case.
In order to program the sensor, the target must be located
within the detection range of the sensor. In this case, the
green LED illuminates.
If the target is located outside of the detection range of
the sensor, the red LED illuminates and programming is
not possible.
If the target exits the detection range during
programming, programming is aborted, the sensor returns
to the previously programmed state or, as the case may
be, to the state on delivery.
If the programming process is not completed, the sensor
returns to the previously programmed state or, as the
case may be, to the state on delivery after 2 minutes.
If an error occurs during programming, the red LED
flashes rapidly. After 4 s, the sensor returns to the
previously programmed state or, as the case may be, to
the state on delivery.
To reset the sensor to the state on delivery, press the
programming button for approximately 8 s until the green
LED stops flashing. In doing so, the target must be
located within the detection range of the sensor.
To change the measuring range, perform the following
steps:
1. Move the position encoder into the detection range of
the sensor. The green LED then illuminates.
2. Press the button until the green LED flashes. In doing
so, pay attention to the cover foil. Use no sharp objects.
3. The sensor is now in programming mode.
4. Move the target to the desired start point.
5. Press the programming button. The green LED flashes
rapidly.
6. Move the target to the desired end point.
The distance to the start point must be greater than
Samax/2; the green LED then flashes rapidly. If the
distance is smaller, this is indicated by the rapidly flashing
red LED.
7. Press the programming button. The green LED
illuminates.
8. The start and end points have been saved. The sensor
is again in working mode.
Characteristics
Standard characteristic
Example: programming and falling characteristic