WIRING INSTRUCTIONS
FOR BAMONIV TPS OR NIVAPRESS SGE 25 TO CONNECTION HEAD BJSC
BAMO IER GmbH ▪Pirnaer Straße 24 ▪68309 Mannheim
SU3733.doc 07/18 3
4. Tighten the sensor cable until the cable tie rests in the connection head
BAMONIV TPS NIVAPRESS SGE 25
Tighten the cable gland until it seals
Tighten the cable gland until it seals
5. Reinstall the circuit board and tighten the screws
BAMONIV TPS NIVAPRESS SGE 25
6. Apply cores according to the terminal assignment
BAMONIV TPS NIVAPRESS SGE 25
Clamp 1: white (+)
Clamp 2: brown (-)
Clamp 3: green/yellow (shield)
Clamp 1: white (+)
Clamp 2: brown (-)
Clamp 3: green/yellow (shield)
7. Stow the ventilation hose in the connection head
BAMONIV TPS NIVAPRESS SGE 25
ATTENTION: Do not kink hose!
Step not necessary