Base aire O-UVC3 Pro User manual

Installation & Operations Manual
O-UVC3 Pro Ozone Generator
Tel: 1-888-641-8862
Web: www.baseaire.com
E-mail: [email protected]

Table of Contents
Device Description
Operation
Mistakes and Shortcomings
Maintenance
Transportation and Storage
Technical Annex
Electrical Wiring Diagram
Limited Warranty
01
02
04
05
06
07
08
09
.........................................................
.........................................................
.........................................................
.........................................................
.........................................................
.........................................................
.........................................................
.........................................................

1
Device Description
Atomic oxygen recombines with oxygen molecules (A) to form ozone.
Ozone is a very powerful oxidant with high reaction potential. This makes it an effective agent for
decomposing destructive substances in the surrounding air. The free radicals bound in the ozone
molecule are separated from the molecular compound (B) and react with all substances in the
surrounding air, even if these substances are only present in a small concentration. The oxidative
decomposition of pollutants in the air and immovable pollutants (for example, on the floor, wall or
ceiling) will eliminate and eliminate odors by killing viruses, bacteria, molds, and carcinogenic/allergenic
microorganisms.
Due to their metastable bonds, unoxidized ozone molecules will also decompose into oxygen after a
period of time without leaving harmful residues. In indoor spaces and under normal conditions, the half-
life of ozone is approximately. 30 to 60 minutes. This means that the ozone concentration in indoor air is
naturally reduced by at least half every hour.
After the reactant oxidizes the oxygen atoms, the ozone molecules will be converted into oxygen
molecules.
The ozone generator sucks in the surrounding air and performs a discharge procedure. After that,
energy breaks the diatomic oxygen molecule into two single oxygen atoms in the form of free radicals.
The O-UVC3 Pro Ozone Generator of the Baseaire series uses oxygen in the surrounding air as a
molecular compound.
Structure
3
2
5
12
11
9
10
1
4
8
7
6
1.Upper shell 2.LED display 3.Circuit board back cover 4.Wind panel
5.Bottom shell 6.Plastic floor 7.Foot pad 8.Ozone generator
9.Fan 10.Air Inlet 11.Suffix socket 12.Handle

2
Operation
State Description of Switch
The default power-on is the shutdown state, at this time only the 4 borders shown in the figure
below are lit (the LCD backlight is turned off after 30s of inactivity).
After pressing the "POWER" key to turn on the machine, the default state is the HOLD working
state, that is, it keeps running according to the set gear.
When setting the timing "CLOCK", a file of 30 minutes, cycle between 00:00 and 02:00, that is, set
the running time as the corresponding working time. When CLOCK is valid, HOLD is off and
CLOCK is on.
Note: When "PERIOD" is not set, PERIOD does not light, at this time it is a single scheduled shutdown.
When the button "PERIOD" is set, it switches between 0, 12, and 24. 0 is invalid.12 hours means
that the cycle will run again according to the time set by CLOCK after 12 hours of shutdown, which
is equivalent to the cycle function.
Gears
The default gear for starting is 1 gear, and the fan and ozone are 5 gears.
The fan has no thyristor speed regulation, the delay after detecting the zero crossing determines the
size of the gear.
Place the Baseaire O-UVC3 Pro ozone machine in the center of the room.
Set the timer to the required run time.
Connect the power cable and connect the device to the power source. Observe the technical
parameters.
Then turn on the device. The display panel will light up. The cleaning cycle will begin immediately.
Once the preset time has passed, the Baseaire O-UVC3 Pro ozone machine will automatically shut
down.
Make sure that the equipment and connecting cables are not damaged.
1.
2.
3.
4.
5.
1.
2.
3.
1.
1.
2.
Generally, ozone will automatically decompose into oxygen in about an hour. If a person stays indoors
for a long time, it is generally subject to not being able to smell the strong ozone smell.
Overall Workflow
When performing odor neutralization and cleaning cycles, follow the steps below.

3
Warning
The risk of ozone causing harm to the human body!
During use, if you smell ozone outside the working area, the machine must stop
working immediately. Ventilate the room thoroughly.
!
The following values are used as a general reference for determining the processing time:
Type of Smell
The treatment time is in min
3
Room size< 30 m
15
20
20
40
40
40-240
360
360
3 3
30 m < Room size< 60 m
30
40
40
60
60
60 - 480
720
720
Disinfectant
Car Interior
From Animals, Cooking and Waste
Burning / Chemical
The Musty Smell After Water Damage
Secondary Effects of a Burning
Smell and Organic Matter
Amine / Amide (urea), Open-chain
Hydrocarbon Compound (e.g.
Butyric Acid)
Amino Acids / Proteins Containing
Nitrogen and Sulfur (vomit)

4
Mistakes and Shortcomings
The equipment has been checked for normal function several times during the production process.
If the fault still occurs, please check the equipment according to the following list.
Warning
Electric shock is life-threatening!
Before performing any operation on the device, please unplug the power plug from
the socket. Do not bypass any electrical safety devices!
In order to ensure the normal operation and trouble-free operation of the equipment, it
must be cleaned and maintained regularly.
!
Problem Cause
Device does not work.
The fuse is blown
The power plug
is damaged.
Solution
Replace the damaged fuse and/or
reopen the fuse. Be careful! The fuse
does not need to be repaired, but it
must be replaced at any time. In most
cases, the fuse is triggered by a serious
technical failure. Please authorized
service personnel to replace each fuse!
Let certified personnel inspect the
equipment.
Loud noise.
Disconnect the power supply of the
device and check whether the power
plug and connecting cable are damaged.
Plug the plug into the socket.
The connection
parameters do not match
the technical
specifications.
Check the connection to the main line.
Connection parameters:
110 V / 60Hz, 1.2A.
Even if the cleaning
process has been
completed, the odor
pollution still persists with
the same intensity.
Send the equipment to a certified
professional workshop for repair.
This device is placed in
an uneven place.
Reactor damage.
Power is not turned on.
Damage to the fan and/or
its bearings.
Place the device on a flat, solid, dry
surface.

5
Maintenance
Electric shock is life-threatening!
Before performing any operation on the device, please unplug the power plug from the
socket. Do not bypass any electrical safety devices!
Inhalation of ozone can cause injury!
The type and frequency of maintenance tasks basically depend on the operating
environment and the time and type of use.
In a dusty room or after repairing a fire (high humidity level), inspection and
maintenance should be carried out immediately.
After the equipment stops running, please wait for a while to ensure that the ozone
concentration is lower than the specified value, and then perform maintenance and
cleaning.
Please perform regular maintenance and maintenance to ensure the normal operation
and trouble-free operation of the equipment.
During use, dust and moisture will accumulate inside or inside the component, which
may affect its function and efficiency.
!
The basic principles for determining equipment operation and maintenance intervals:
Per hour
In a humid room
Often
In an overly dirty environment
1-2 times a week
Regardless of the operating conditions described, you should perform maintenance if one or
more of the following signs appear:
The noise level increases when the fan is running.
The substances produced during the ozone production process gradually disappear.
Severely polluted soft magnetic stickers.
Dirty electrodes (identifiable by hissing sound).
House Cleaning
Clean the case with a soft, damp, lint-free cloth. Make sure that no moisture enters the enclosure.
Prevent electrical components from getting wet. Do not use any harsh cleaning agents, such as cleaning
sprays, solvents, alcohol-based cleaning agents, or abrasives to soak the cloth.
Cleaning
Within the framework of regular maintenance work, it is not only necessary to check the normal
condition of the equipment and its accessories, but also to thoroughly clean the equipment and its
components.
Proceed As Follows:
Remove the screws on the dust cover.
Remove the shell.
Disassemble and clean the fan. Always check whether the fan is working properly. If it is only slightly
contaminated, you can use a vacuum cleaner or a tap to clean it. If the contamination is serious,
clean the reaction generator with a soap solution. After cleaning, insert the fan only after it is
completely dry!
Clean the fan
1.
2.
3.

6
Transportation and Storage
Pay attention to information about transportation and storage.
If you store or transport the device incorrectly, the device may be damaged.
Transportation
Before transporting the equipment, please observe the following regulations:
If the device was in use before, please wait until the timing period is over before transferring the
device.
Do not drag the device with the power cord during transportation to prevent the device from moving
and vibrating to avoid damage to the electrode.
Turn off the device.
Hold the power plug while unplugging the power cord from the power outlet.
After transporting the equipment, please observe the following regulations:
Install the equipment in an upright position after transportation.
Storage
When the device is not in use, please observe the following storage conditions:
Store the Baseaire O-UVC3 Pro Ozone Generator in a dry place to avoid the influence of bad
weather, and cover it to protect it from invasive dust.
When the equipment is not in use, always disconnect the power supply.
Clean Electrode
The electrode can be cleaned in the built-in state. Before cleaning the electrode, check for cracks. Do
not use damaged parts!
Use a dry (lint-free) or damp cloth to clean the components. After cleaning, make sure that no fibers
(fluff) remain on the electrode.
Do not use the device before the electrodes are completely dry.
The following requirements must be met when installing the Baseaire O-UVC3 Pro Ozone Generator:
Ensure that the equipment is protected from splash water.
Only use the Baseaire O-UVC3 Pro Ozone Generator according to the parameters provided in the
"Technical Data" chapter.
Make sure to place the device on a dry and vibration-free surface.
Make sure that there are no obstructions at the air inlet and outlet.
If possible, place the device in the center of the room to ensure optimal air circulation.
Do not install this machine near flammable substances or gases.

7
Technical Annex
Parameter
Power
Environmental Humidity Requirements
Ozone Output
Operating Temperature
Sound Pressure Level
Service Life
Size For
Dimensions (L×W×H)
Minimum Distance From Walls and
Other Objects:
Top ( a )
Rear ( b )
Sides ( c )
Front ( d )
Value
110V / 60HZ, 1.2A
< 55%
130 CFM / 220 CMH
15,000 mg/h
14℉ ~ 95℉
< 65 db
25,000 h
1,600 sq. ft
10.2 x 6.9 x 8.7 in
20 in
20 in
20 in
20 in
Airflow

8
Electrical Wiring Diagram

9
Limited Warranty
Warranty becomes effective since the date of original purchase and will last for two (2) years.
This limited warranty is only effective for the original purchaser. It is NOT transferable.
Who’s Covered?
Warranty Period
This limited warranty is only effective for the original purchaser. It is NOT transferable.
Who’s Not Covered?
2. Damage caused by misuse, abuse, neglect, alterations or unauthorized repair.
1. Damage caused by the owner when attempting to fix or alter the product by himself or herself.
3. Natural depreciation.
How to Request Warranty Services?
To obtain the benefit of this warranty, please leave your message online (www.baseaire.com), or send an email to
Our customer service will address your issue in 24 hours.
All warranty benefits apply to the original owner only. Warranty cannot be transferred or assigned.
If the unit can no longer be fixed, and it is in the warranty period and determined to be valid claim, we will
ship the customer a new unit within the same year warranty from the date of replacement.
If no warranty registration is sent to us, warranty period will begin the day the shipment left the
warehouse. Please be sure to record serial # and date of installation. You will need this information to
receive the RA number.
After the unit has been received by BaseAire (whether at a repair center or the warehouse), BaseAire will
have an initial inspection If it is determined to be invalid warranty claim (see exclusions below),
customers have to pay for all associated repair costs and shipping costs for units repair.
After parts are repaired or replaced by BaseAire, the original warranty period continues to applies until
meet its deadline. No extensions to the original warranty period.
Customers can pick up the unit after repair at their own expense for shipping. Units will have a rigorous
testing before sending it back to customers.
Once receive the goods, customers must log in www.baseaire.com to fill out the warranty Registration
form and submit to BaseAire company. We will receive your purchasing and installation information and
save it.
If warranty service is necessary, customers must contact BaseAire Tech Support by sales@baseaire.com
or local technical service phone to receive a Return Authorization (RA number). Once an RA has been
issued, customers should bring the unit to a certified repair center. BaseAire will arrange the shipping to
bring the unit back to the BaseAire warehouse (at the expense of the customers) if customers are not
available.
BaseAire Warranty Steps:
1.
2.
3.
4.
5.
6.

10
Limited Warranty Exclusions
Water Damage
Improper Installation Or Design
Lack Of Normal Care
Flooding
ACTS OF NATURE- INCLUDING BUT NOT LIMITED TO:
Fire
Hurricane Storm Damage
IMPROPER USAGE-INCLUDING BUT NOT LIMITED TO:
Pool/spa/tub Applications
Misuse, Abuse Or Tampering Whether Intentional Or Accidental
Mproper Voltage
Failure To Follow Instructions
CORROSION
FREEZING
ANY ADDITIONAL COSTS DUE TO CHANGES IN LAWS OR BUILDING CODES
FREIGHT CHARGES
ANY COSTS DUE TO LOST PROFIT OR DELAY
DAMAGE TO PROPERTY
CAUSE BEYOND CONTROL
DIRECT, INDIRECT, COLLATERAL OR INCONSEQUENTIAL DAMAGES OF ANY KIND
EXCLUSIONS:
DAMAGE DUE TO THE FOLLOWING IS NOT COVERED UNDER WARRANTY
THE WARRANTIES AND LIABILITIES SET FORTH ARE IN LIEU OF ALL OTHER WARRANTIES
EXPRESSED OR IMPLIED IN LAW OR IN FACT, INCLUDING IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE.
Any dishonesty or fraud in connection with BaseAire warranty thoroughly voids all warranty
policies. BaseAire expressly reserves the right to pursue legal action in the event of dishonesty,
fraud, or attempted fraud.
The foregoing shall constitute the total liability of seller in the case of defective performance of
all or any of the equipment or services provided to buyer. Buyer agrees to accept and hereby
accepts the foregoing as the sole and exclusive remedy for any breach or alleged breach of
warranty by seller.
BaseAire's total liability, regardless of nature of claim shall not exceed original purchase
exceed original purchase price of the product, if a product or component is replaced while under
warranty, the applicable warranty period shall not be extended beyond the original warranty
time period.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
Table of contents