Rapide Inline Extractor Fans
Thank you for purchasing product.
Please read through these instructions carefully and refer back to them during installation to
ensure that your product is fitted safely and that it retains its high quality finish.
Please see Fig. 1 on the back page for details
Suitable for installation in zones: 2 & Outside Zones
Please retain this leaflet for future reference.
Before drilling, ensure there are no hidden cables or pipes in the wall
FI #05 002 R180214 Ver No. 2.0 Feb 2018

2
Warning
The Rapide LED Inline Fans (41800040660 & 41800040670) are supplied with an
MR16 3 Watt LED lamp. This is the only lamp suitable for use with this fan.
Exceeding the lamp wattage will invalidate the warranty.
The fan must be connected to power mains through an automatic circuit breaker
integrated into the fixed wiring system with the gap between the breaker
contacts on all poles not less than 3mm. Check the fan for any visible damages
of the impeller and the casing before starting installation. The casing internals
must be free of any foreign objects which can damage the impeller blades.
Misuse of the product or any unauthorized modification will invalidate the
warranty.
Take steps to prevent ingress of smoke, carbon monoxide and other combustion
products into the room through open chimney flues or other fire-protection
devices. Sufficient air supply must be provided for proper combustion and
exhaust of gases through the chimney of fuel burning equipment to prevent
back draing.
In The Box
1. 1x Fascia
2. 1x LED Driver (41800040660 & 41800040670 only)
3. 1x High powered Inline fan
4. 1x 3 metre flexible ducting (Ø100mm)
5. 1x Brown external fixed grille
6. 4x Galvanized steel hose clamps
7. 1x Screw and dowels pack
8. 1x Plastic screwdriver
9. 1x Fitting instructions
Please Note; The fan may operate immediately when connected, this is normal
and due to a residual charge le in the capacitor during testing. Should this occur,
switch off, adjust timer to desired setting then turn back on (see page 6 for Timer
System).

3
www.bathstore.com
Mounting - Fascia
1. Ceiling mounted ventilation should be ducted through the roof space, by
ducting to an external soffit under the eaves or grille in the slope of your roof.
NB: Ducting installed between a floor and ceiling can only run between joists,
not across them.
2. Remove the fascia grille by twisting anticlockwise. Mark the position of the
fascia with a pencil in a suitable position on the ceiling, making sure that it is
between the joists.
3. Drill a 9mm hole through the ceiling anywhere along the edge of the pencil
line. Now cut out the hole with a pad saw/hole saw.
4. Hold the vent fascia against the ceiling and mark the position of the fixing
holes. Fix the unit in place using suitable plasterboard fixings (not supplied).
Re-attach the fascia grille by twisting clockwise.
5. Attach flexible ducting with the metal hose clamps. Ensure that the ducting
has a smooth flow towards the motor body to minimise air resistance. Follow
a similar procedure for the outside wall grille. Extra ducting may be used to
extend the distance to the external grille but performance will be reduced.
min 1m
Fig. A horizontal on a wall Fig. B horizontal on a oor Do not mount vertically

4
2. Place motor in desired
location and mark
fixing holes.
3. Fix motor to desired surface,
using suitable wall plugs if
necessary.
4. Connect the flexible ducting to both sides of the Inline fan with the metal
hose clamps. Ensure there is a minimum of 1m straight ducting between
fascia and fan.
Mounting - Fan unit
1. Install the Rapide Inline fan within the lo or ceiling space (ensuring correct
direction of air flow using arrows on the fan). DO NOT COVER motor or LED
driver with lo insulation. The fan is suitable for only horizontal mounting on a
wall (fig. A) or a floor (fig. B). When mounting the fan ensure there is a minimum
of 1m straight ducting to the motor body (see Fig B, p.3).

5
www.bathstore.com
2. Using a screw driver,
remove cover.
3. Using a screw driver, remove cable grip.
Feed cable through hole & replace grip.
4. Wire the fan as per the diagram below. The feeds for this fan can be
found in the bathroom ceiling rose or light fitting.
5. Replace cover using a suitable screw driver.
6. On Illuminated versions (41800040660 & 41800040670)the mains supply from
the bathroom fitting should be connected to the LED driver as per the wiring
diagram for lamp (see Fig. C, p.7).
7. Fix the external grille to the soffit in the same way as the ceiling fascia with 4
screws.
CB - Circult Breaker
SW - External Switch (e.g. light switch)
N
L
SW
CB N
L
LT
~
FAN TERMINAL
1. Ensure the mains power supply to which the fan is being connected is turned
off. This product is designed to be connected to an on/off switch outside the
bathroom, or to a ceiling mounted pull cord switch.
Electrical Connection
LINE = This is the terminal that is only
live when the switch is on (LT)
LOOP = This is the terminal that is
permanently live (L)
NEUTRAL = This is the terminal that is
always neutral (N)

6
Timer System
Warning! The timer circuit is under mains voltage. Ensure mains power
supply is switched off before making any adjustments.
The fan is operational aer the control voltage is supplied by the external switch
(e.g., by the light switch) to the input terminal LT. Aer the fan is switched off the
fan continues to operate within the timer period set by the timer from 2 to 30
minutes. To adjust the run on timer, rotate the control knob clockwise to increase
and anti-clockwise to decrease the off-delay time respectively (see below
diagram). Please note the adjustment should only be done without the fan
running.
The set includes a specially designed plastic screwdriver for timer setting
adjustments. Only use the plastic screwdriver to alter the turn-off delay time. Do
not use a screwdriver, knife, etc. for adjustments so as not to damage the circuit
board.

7
www.bathstore.com
Operation
The fan is rated for connection to single-phase AC220-240 V / 50/60 Hz power
mains. The fan is designed for continuous operation always connected to mains
power. Air motion direction in the system must match the pointer on the fan
casing. Ingress protection rating IPX4.
Maintenance
Fan maintenance is to be performed only aer the fan is disconnected from the
mains power suppy. Maintenance means periodic cleaning of the surface of dust
and dirt.
All surfaces should be cleaned with diluted detergent, i.e. washing up liquid, and
a so cloth. Scourers and scouring agents should not be used, as these may cause
damage to the surface of the product.
Avoid water dripping on the electric components. Wipe the surfaces dry aer
cleaning.
Technical Information
Power Input: 220-240V, 50/60Hz
Maximum Ventilation Volume: 137m3/hr (±5%) / 38.056 Litres Per Second
Power Consumption: 16W + 3W LED Lamp (41800040660 & 41800040670)
Decibel: 37dB
Dimensions: Ø14 x D7.3cm
Wiring Diagram For Lamp
(41800040660 & 41800040670 only)
AC in DC out
Live is RedLive supply is Red or Brown
Neutral supply is Blue or Black
Neutral is Black
(Fig. C)

(Fig 1)
These products are suitable for installation in zones: 2&Outside Zones
All installations must comply with guidelines which are based on a zonal concept. The diagram above
illustrates this concept and must be followed to ensure the safe installation of electrical appliances in
the bathroom. These regulations apply to domestic installations only. Installations must be made in
accordance with the current IEE wiring regulations and relevant building regulations. It is recommended
that all electrical bathroom products should only be fitted by a suitably qualified, Part P registered
electrician.
Electrical Safety Information
Ensure mains power supply is switched off before starting installation. Before drilling, ensure there are
no hidden cables or pipes in the wall.
Care Instructions
Do not use abrasives or solvents when cleaning this product.
Wipe off all water spillages as soon as possible using a so, damp cloth.
WEEE compliance
Must not be mixed with general household waste
This manual suits for next models
3
Table of contents
Other bathstore Fan manuals
Popular Fan manuals by other brands

Exquisit
Exquisit VT 34062 we instruction manual

Fanimation
Fanimation Louvre FP1320 Series Specification sheet

Base
Base EXTRACTOR FANS instruction manual

NuTone
NuTone 744SFLNT Architectural & engineering specifications

KDK
KDK F-M14D5 Operating and installation instructions

Broan
Broan B110H65RT User's and installer's manual