manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. BEA
  6. •
  7. Controllers
  8. •
  9. BEA Hunter LO-LINX Quick start guide

BEA Hunter LO-LINX Quick start guide

Other BEA Controllers manuals

BEA LO Linx 80.0240.04 Quick start guide

BEA

BEA LO Linx 80.0240.04 Quick start guide

BEA Sliding Door Lock With Wizards Quick start guide

BEA

BEA Sliding Door Lock With Wizards Quick start guide

BEA LO Linx Assembly User guide

BEA

BEA LO Linx Assembly User guide

BEA Stanley Dip Switch I Quick start guide

BEA

BEA Stanley Dip Switch I Quick start guide

BEA Two MC50s Interlocking 4 Doors Quick start guide

BEA

BEA Two MC50s Interlocking 4 Doors Quick start guide

BEA Br3x User manual

BEA

BEA Br3x User manual

BEA MS41 User manual

BEA

BEA MS41 User manual

BEA MC-Linx Assembly User guide

BEA

BEA MC-Linx Assembly User guide

BEA Horton 80.0091.02 Quick start guide

BEA

BEA Horton 80.0091.02 Quick start guide

Popular Controllers manuals by other brands

Sunricher SR-ZV9003T3-RGBW-US Installation

Sunricher

Sunricher SR-ZV9003T3-RGBW-US Installation

Ksenia intro Installation and configuration manual

Ksenia

Ksenia intro Installation and configuration manual

Inovance CAN200 Series manual

Inovance

Inovance CAN200 Series manual

Gauzy LC6 FLEX Controller Installation and operation guide

Gauzy

Gauzy LC6 FLEX Controller Installation and operation guide

Viking SLP-1 Technical practice

Viking

Viking SLP-1 Technical practice

CKD KBX-30E-U Series instruction manual

CKD

CKD KBX-30E-U Series instruction manual

Sharp Energy Sun Flux User manual & installation guide

Sharp Energy

Sharp Energy Sun Flux User manual & installation guide

Yamaha RCX40 user manual

Yamaha

Yamaha RCX40 user manual

AB Quality PowerFlex 400 Frames D-H Service bulletin

AB Quality

AB Quality PowerFlex 400 Frames D-H Service bulletin

Yamaha MJC8 owner's manual

Yamaha

Yamaha MJC8 owner's manual

AL-KO ATC operating instructions

AL-KO

AL-KO ATC operating instructions

Savant SmartControl 2 Deployment guide

Savant

Savant SmartControl 2 Deployment guide

GameSir T3S user manual

GameSir

GameSir T3S user manual

Kostal inveor operating manual

Kostal

Kostal inveor operating manual

Emerson Yarway 20-55 Operating and safety instructions

Emerson

Emerson Yarway 20-55 Operating and safety instructions

CoCo ACM-LV24 Quick installation guide

CoCo

CoCo ACM-LV24 Quick installation guide

Brooks SLA5810/20 Installation and operation manual

Brooks

Brooks SLA5810/20 Installation and operation manual

SIGMA TEK SR 011 Technical manual

SIGMA TEK

SIGMA TEK SR 011 Technical manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

NOTES: 1) BEA RECOMMENDS TO USE THE HUNTER SYNC BOARD TO SYNC 2 DOOR CONTROLS WITH A PAIR OF DOORS.
2) IF USING AN OPTIONAL INHIBIT SWITCH FOR THE SAFETY SIDE SUPERSCAN. ROUTE THE INHIBIT SWITCH N.C. CONTACT TO STALL 1 &/OR 2.
IF AFTER TROUBLESHOOTING A PROBLEM, A SATISFACTORY SOLUTION CANNOT BE ACHIEVED, PLEASE CALL B.E.A., INC.
FOR FURTHER ASSISTANCE DURING EASTERN STANDARD TIME AT 1-800-523-2462 FROM 8AM - 5PM. FOR AFTER-HOURS,
CALL EAST COAST: 1-866-836-1863 OR 1-800-407-4545 / MID-WEST: 1-888-308-8843 / WEST COAST: 1-888-419-2564. DO NOT
LEAVE ANY PROBLEM UNRESOLVED. IF YOU MUST WAIT FOR THE FOLLOWING WORKDAY TO CALL B.E.A., LEAVE THE
DOOR INOPERABLE UNTIL SATISFACTORY REPAIRS CAN BE MADE. NEVER SACRIFICE THE SAFE OPERATION OF THE
AUTOMATIC DOOR OR GATE FOR AN INCOMPLETE SOLUTION.WEB: WWW.BEASENSORS.COM
Pre-wired
switch
assembly
HOLD OPEN
OFF
AUTO
LO-LINX
SETUP
PWR
TO CTRL
BEAM
TX RX SWITCH
AUXSENSORSMTR STALL
ACTIVATION SUPERSCAN SAFETY SUPERSCAN
EAGLE 1
EAGLE 2
MOTOR -
+
24 V
TRANSFORMER
RED
RED
BROWN
WHITE
BLUE
YELLOW
GREEN
ACTIVATION SUPERSCAN SAFETY SUPERSCAN
BODYGUARD
BODYGUARD 2
BLACK
RED
RED
BLACK
WHITE
BODYGUARD (Y) HARNESS
USED FOR DUAL-EGRESS
APPLICATIONS
SIZE: DRAWN BY:
TITLE: Hunter FA Control,LO-LINX
A
100 ENTERPRISE DRIVE
PITTSBURGH, PA 15275
PHONE: (412) 249-4100
FAX: (412) 249-4101
EMAIL: www.beasensors.com
REV BY: 80.0272.01
SCALE: DATE:
NONE 05/17/2007
PART NO:
SHEET
1 OF 1
JED TUC
IF AFTER TROUBLESHOOTING A PROBLEM, A SATISFACTORY SOLUTION CANNOT BE ACHIEVED, PLEASE CALL B.E.A., INC. FOR FURTHER ASSISTANCE
DURING EASTERN STANDARD TIME AT 1-800-523-2462 FROM 8AM - 5PM. FOR AFTER-HOURS, CALL EAST COAST: 1-866-836-1863 OR 1-800-407-4545 /
MID-WEST: 1-888-308-8843 / WEST COAST: 1-888-419-2564. DO NOT LEAVE ANY PROBLEM UNRESOLVED. IF YOU MUST WAIT FOR THE FOLLOWING
WORKDAY TO CALL B.E.A., LEAVE THE DOOR INOPERABLE UNTIL SATISFACTORY REPAIRS CAN BE MADE. NEVER SACRIFICE THE SAFE OPERATION
OF THE AUTOMATIC DOOR OR GATE FOR AN INCOMPLETE SOLUTION.WEB: WWW.BEASENSORS.COM
SIZE: DRAWN BY:
TITLE: HUNTER LO-LINX SYSTEM
A
100 ENTERPRISE DRIVE
PITTSBURGH, PA 15275
PHONE: (412) 249-4100
FAX: (412) 249-4101
EMAIL: www.beasensors.com
REV BY: 80.0285.00
SCALE: DATE:
NONE 10/15/2007
PART NO:
SHEET
1 OF 1
JED TUC
NOTES:
1. MOTOR CONNECTION IS TIED IN PARALLEL TO EXISTING MOTOR LEADS. NO RESPECT TO PALARITY IS REQUIRED.
2. EXTERNAL SWITCHES ARE REQUIRED IF INHIBIT DESIRED AT SWING SIDE SUPERSCANS, SWITCH OPENS UPON INHIBIT POINT.
3. THE KNOWING ACT SWITCH IS CONNECTED AT THE AUX INPUT AND CAN BE ANY DRY CONTACT DEVICE SUCH AS A PUSHPLATE, CARD READER,
ETC. THE AUX INPUT IS REQUIRED FOR ALL INITIAL ACTIVATION WHEN FUNCTION 'FA' ON THE LO-LINX IS SET TO '01'.
4. THE SECOND BODYGUARD AND EAGLE ARE PRIMARILY USED IN DUAL-EGRESS APPLICATIONS. ENSURE BODYGUARD RELAY VALUE IS SET TO 2.
5. BEA RECOMMENDS TO USE THE HUNTER SYNC BOARD TO SYNC 2 DOOR CONTROLS FOR A PAIR OR DOUBLE EGREES SET OF DOORS.
BROWN
WHITE
BLUE
YELLOW
GREEN
Pre-wired
switch
assembly
DC
MOTOR -
+RED
RED
BLACK
RED
BODYGUARD (Y) HARNESS
USED FOR DUAL-EGRESS
APPLICATIONS
*
LO-LINX SUPERSCAN HARNESS
p/n: 70.5071
LO-LINX EAGLE HARNESS p/n: 20.5096
LO-LINX BODYGUARD
HARNESS p/n: 20.5082
LO-LINX POWER
HARNESS p/n: 20.5095
LO-LINX SWITCH HARNESS p/n: 20.5078
LO-LINX CONTROL
HARNESS p/n: 20.5097
24 V
TRANSFORMER
HOLD OPEN
OFF
AUTO
RED
BLACK
WHITE
LO-LINX MOTOR HARNESS p/n: 20.5076
75.5137.02
LO-LINX
SETUP
INCR.
FUNCT.
12-24V
AC/DC
PWR
TO CTRL
STALL
SAFETY
ACTIV.
STALL COM
SFTY / ACT COM
BEAM
TX RX SWITCH
GND
AUTO
HOLD
AUX
COM
N/O
EAGLE 1
EAGLE 2
BODY-
GUARD
SENSORS
DOOR MTD
SENSOR 1
DOOR MTD
SENSOR 2
MTR
MOTOR
STALL 1
STALL
STALL 2
EMPTY1
INHIBITGND2
INHIBIT+3
N.C.4
N.O.5
COM6
POWER7
POWER8
EMPTY1
INHIBITGND2
INHIBIT+3
N.C.4
N.O.5
COM6
POWER7
POWER8
RED
BLACK
WHITE
GREEN
RED
BLACK
WHITE
GREEN
DOOR MTD SENSOR
APPROACH SIDE DOOR MTD SENSOR
SAFETY SIDE
EMPTY1
INHIBITGND2
INHIBIT+3
N.C.4
N.O.5
COM6
POWER7
POWER8
EMPTY1
INHIBITGND2
INHIBIT+3
N.C.4
N.O.5
COM6
POWER7
POWER8
RED
BLACK
WHITE
GREEN
RED
BLACK
WHITE
GREEN
DOOR MTD SENSOR
APPROACH SIDE DOOR MTD SENSOR
SAFETY SIDE
GREEN
WHITE
BLACK
RED
EAGLE 1
GREEN
WHITE
BLACK
RED
EAGLE 2
RED
BLACK
WHITE
BROWN
BLUE
GREEN
RED
BLACK
WHITE
BROWN
BLUE
GREEN
SEE NOTE # 4
SEE NOTE # 4
SEE NOTE
#2
SEE NOTE #1
LO-LINX GREEN WHITE
Y
ELLO
W
BLUE BROWN
SWING ACT.COM.SAF.STALLSTALCOM.
B E S A M 3 0 0 13 12 11 15 , 17 16 , 18
BESAM M/P 3 4 9 5 13
DOM YELLOW GREY BLUE PURPLE GREY
GT 300/400 BLACK RED WHITE WHITE RED
GT M AG 6 BLACK 5 RED 4 WHITE 3 VIOLET 5 RED
HORTON 4190 2 3,6,8 4 10 3,6,8
HUNTER ACT. RTN SAF.1 SAF.2 RTN
KM K GREEN WHITE RED YELLOW WHITE
STANLEY "L" ORANGE YELLOW RED BLUE YELLOW
STANLEY M/P 2 1,8 7 7 1,8
STANLEY 521 TB4-5 TB4-4 TB4-8 TB4-10 TB4-9
TORM AX TDA 2 1,3, 6, 8 8 & 9 7 1, 3, 6, 8
COM
N/O
SEE NOTE #3
SEE NOTE # 4