Berbel Downline Performance BKA 83 DLP User manual

EN Hob extractor fan
Downline Performance
EN Operating and installation instructions for the models
/BKA 83 DLP
6006619_a

2
6006619_a – 12.01.2023
Document information
Operating and installation instructions for:
2Hob extractor fan BKA 83 DLP E07
2Original instructions.
2Part of the product.
2Copyright protected.
2Duplications, re-printing and distribution only with
permission.
2Subject to alteration.
Safety information
.DANGER!
Notes with the word DANGER warn of a hazardous situation
that results in serious injuries or death.
.WARNING!
Notes with the word WARNING warn of a hazardous situation
that could result in serious injuries or death.
.CAUTION!
Notes with the word CAUTION warn of a situation that could
result in minor injuries.
.ATTENTION!
Notes with the word ATTENTION warn of a situation that
could result in damage to property or to the environment.
Symbol clarification - text
1Handling requirement
2Listing
,Reference to another point in this document
-Reference to other documents that should be observed
Symbol clarification - illustrations
x
A
B
1.
2.
Highlighting of the parts involved in the action with
shading
1. Handling steps with numbering
APart designations with upper case characters
xDimensions with lower case characters or units in mm
Movement and direction arrows

3
6006619_a – 12.01.2023
EN
Table of contents
1. Safety information ............................ 4
1.1 Proper intended use . . . . . . . . . . . . . . . . . . . . . 4
1.2 Authorised target groups . . . . . . . . . . . . . . . . . . 4
1.3 General safety instructions . . . . . . . . . . . . . . . . . 5
2. Product information ........................... 6
2.1 Functional principle . . . . . . . . . . . . . . . . . . . . . 6
2.2 Operating modes. . . . . . . . . . . . . . . . . . . . . . . 6
2.2.1 Recirculated air mode.........................6
2.2.2 Extraction mode ..............................6
2.3 Product overview . . . . . . . . . . . . . . . . . . . . . . . 7
2.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.5 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . 8
2.5.1 Hob extractor fan .............................8
2.5.2 Accessory recirculating air kit DL BUF..........8
2.5.3 Accessory recirculating air kit DL BUR .........9
2.5.4 Accessory exhaust air kit DL ..................9
3. Installation ...................................10
3.1 Safety instructions for installation. . . . . . . . . . . . .10
3.2 Requirements for the installation location . . . . . . .10
3.3 Requirements for individual operating modes. . . . .11
3.3.1 Requirements for recirculated air mode .....11
3.3.2 Requirements for extracted air mode........11
3.4 Requirements for the exhaust air ducting
(only for extracted air mode). . . . . . . . . . . . . . . .11
3.5 Installation procedure . . . . . . . . . . . . . . . . . . . .12
3.5.1 Preparation for installation ..................12
3.5.2 Unpack the device ..........................12
3.5.3 Check the dimensions ......................13
3.5.4 Install the hob ..............................14
3.5.5 Install recirculating air kit DL BUF............16
3.5.6 Install recirculating air kit DL BUR............17
3.5.7 Install exhaust air kit DL .....................19
3.5.8 Connect accessories ........................20
3.5.9 Connect light source (optional) .............21
3.5.10 Establish electrical power supply ............21
3.5.11 Check and carry out commissioning ........22
4. Operation ....................................23
4.1 Safety instructions for operation . . . . . . . . . . . . .23
4.2 Cooking with induction . . . . . . . . . . . . . . . . . . .24
4.3 Control panel . . . . . . . . . . . . . . . . . . . . . . . . .24
4.4 Operation of the hob . . . . . . . . . . . . . . . . . . . .27
4.4.1 Automatic rapid heat-up function...........28
4.4.2 Pause function ..............................28
4.4.3 Recall function ..............................28
4.4.4 Cleaning function ...........................28
4.4.5 Locking function ............................29
4.4.6 Maintenance function.......................29
4.4.7 Grill function ................................29
4.4.8 Head chef function. . . . . . . . . . . . . . . . . . . . . . . . . . 29
4.4.9 Automatic pot recognition function.........30
4.4.10 Volume function ............................30
4.4.11 Light function (optional) ....................30
4.4.12 Timer function ..............................31
4.4.13 Bridge function .............................32
4.4.14 “Pot move” function .........................32
4.4.15 “Pot speed test” function ....................32
4.5 Extraction operation . . . . . . . . . . . . . . . . . . . . .33
4.5.1 Operating modes ...........................33
4.5.2 Run-on function ............................34
5. Cleaning .....................................35
5.1 Safety instructions for cleaning . . . . . . . . . . . . . .35
5.2 Cleaning procedures. . . . . . . . . . . . . . . . . . . . .35
6. Maintenance .................................37
6.1 Safety instructions for maintenance . . . . . . . . . . .37
6.2 Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . .37
6.3 Fault rectification . . . . . . . . . . . . . . . . . . . . . . .39
7. Disassembly ..................................40
8. Disposal ......................................41
8.1 Dispose of packaging . . . . . . . . . . . . . . . . . . . .41
8.2 Dispose of the device . . . . . . . . . . . . . . . . . . . .41
9. Annex ........................................42
9.1 Product data sheet . . . . . . . . . . . . . . . . . . . . . .42
9.2 Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43

4
Safety information
6006619_a – 12.01.2023
1. Safety information
1.1 Proper intended use
The device is designed for normal domestic cooking, frying
and heating of foods on an electrically operated induction
hob.
With the integrated ventilation system, the device is also
designed for extraction of cooking vapours.
The device is intended exclusively for private domestic use.
The device must only be used with original filters from the
manufacturer.
It is only permitted to use the device when it is in technically
flawless condition and after correct installation.
Any other use shall be considered improper use.
The reading and observance of this manual are also included
in the proper use of the device.
1.2 Authorised target groups
Electrical work only to be undertaken by qualified electricians.
Requirements on qualified electricians:
2Knowledge of the basics of electrics.
2Knowledge of country-specific regulations and standards.
2Knowledge of the applicable safety regulations.
2Knowledge of the relevant legal requirements for gas
installations.
2Knowledge of this manual.
Installation and repair only by qualified specialist personnel.
Requirements on qualified specialist personnel:
2Knowledge of the regulations on safety at work.
2Knowledge of fastening systems.
2Basic knowledge of ventilation systems.
2Experienced in using electrical and mechanical tools.
2Ability to read technical drawings.
2Knowledge of this manual.
Operation, cleaning and maintenance by the user.
Requirements for the user:
2Knowledge of this manual.
There are separate requirements for the following users:
2Children from 8 years and older.
2Persons with restricted physical, sensory or mental
capabilities.
2Persons with a lack of experience and knowledge.
These users are only permitted to carry out operation,
cleaning and maintenance. Special requirements:
2Users are supervised.
2Users are instructed with regard to safe use of the device.
2Users understand the hazards involved with the device.
2Children may not play with the device.
Particular details for children under eight years of age:
2The hob becomes hot during operation. The hob remains
hot for a while after it has been switched off. Children
must be kept away from the hob until all risks of burns
can be ruled out.
2Objects which can be interesting to children must not be
stored in the vicinity of the hob.
2Pot and pan handles must be positioned on the hob such
that they cannot be reached by children.
2Children must be monitored continuously if they are in
the vicinity of the hob.

5
Safety information
6006619_a – 12.01.2023
EN
1.3 General safety instructions
.WARNING!
Hazard through a disregard of the operating and
installation instructions!
This manual contains important information for the safe
handling of the device. Separate reference is made to
possible hazards.
1Read through this manual thoroughly.
1Follow the safety instructions in this manual.
1Store the manual in an accessible location.
Naked flames can damage the device and can cause fires.
2Do not flambé on or near the device.
2No unattended deep frying on or near the device.
The use of the device is forbidden under the following
circumstances:
2If necessary safety devices are missing (e.g. Window
contact switch whilst using a heating point which uses air
from the room as its oxygen supply).
2If essential approvals are missing (e.g. from chimney
sweeps).
2In potentially explosive atmospheres.
2If the device or individual components are damaged.
2In the event of unauthorised alterations or changes to the
device.
2If liquid has penetrated the device.
2When heavily soiled.
2For children under 8 years old and persons who would
not be able to properly assess the hazards associated with
handling the device.
The manufacturer accepts no liability for damage occurring in
the following circumstances:
2Disregard of this manual.
2Improper use of the device.
2Improper installation and handling of the device.
2Use of the device by unauthorised target groups.
2Bypassing safety equipment on the device.
2Use of replacement parts (e.g. mains cable) that were not
produced or approved by the manufacturer.
2In the case of incorrect use (e.g. heating cooking oils and
cooking fats with a temperature above the smoke point).
Further safety instructions can be found in the respective
relevant chapters of this manual.
,“3.1 Safety instructions for installation” (page 10).
,“4.1 Safety instructions for operation” (page 23).
,“5.1 Safety instructions for cleaning” (page 35).
,“6.1 Safety instructions for maintenance” (page 37).

6
Product information
6006619_a – 12.01.2023
2. Product information
2.1 Functional principle
Food is cooked, fried or heated on the induction hob.
Cooking vapours that develop in the process are drawn
through the opening in the hob where they are accelerated
and routed through bends.
The resultant centrifugal force ejects particles of dirt
(e.g. particles or grease and oil) out of the air and collects
them in the device.
2.2 Operating modes
The device is used with the corresponding accessories in the
following operating modes:
2Recirculated air mode
2Extraction mode
2.2.1 Recirculated air mode
The filter filling in the recirculated air filter neutralises any
smelly odours present. The odour-free, cleaned room air is
fed back into the room. The humidity in the room can be
reduced with the fresh air feed.
In recirculated air mode, it is necessary to use the run-on
function so that the device can remove the remaining
odours. Using the run-on function increases the life of the
filter filling. The filter filling must be replaced at regular
intervals.
In the case of devices with recirculated air filter permalyt,
as an extension for permanent odour retention there is no
need to renew the filter filling.
2.2.2 Extraction mode
The cleaned room air can be routed to the outside via the
building structure (e.g. ducting, chimney).
With extracted air mode an adequate fresh air supply is
required. The device can only extract the amount of air to the
outside that is present in the room or which is drawn into the
room.

7
Product information
6006619_a – 12.01.2023
EN
2.3 Product overview
C
B
A
D
E
H
F
G
I
A Powermover
B Intake grate
C Separator insert, consisting of upper and lower part
D Control panel
E Hob with four cooking zones
F Work top (not included in the scope of delivery)
G Lower cabinet (not included in the scope of delivery)
H Recirculated air filter
I Fan housing with service cover
2.4 Technical data
Hob extractor fan BKA83 DLP
E07
Connection voltage 400 V ~ /
50/60 Hz
Total power 17630 W
Power consumption of the hob 2184.5 Wh/kg
Power consumption of the fan 1x 230 W
Hob width 830 mm
Hob depth 505 mm
Hob height 249 mm
Hob net weight 20 kg
Cooking zones Front
left
Rear
left
Rear
right
Front
right
Dimensions 225.5 x
225.5 mm
225.5 x
225.5 mm
225.5 x
225.5 mm
225.5 x
225.5 mm
Min. pot base
diameter 100 mm 100 mm 100 mm 100 mm
Output 12100 W 2100 W 2100 W 2100 W
Output
Booster 12600 W 2600 W 2600 W 2600 W
Output
Double booster 13700 W 3700 W 3700 W 3700 W
Power
consumption per
kg 2
182.2
Wh/kg
190.6
Wh/kg
182.2
Wh/kg
182.8
Wh/kg
Standardised
cookware
category
C B C A
Bridge function yes yes yes yes
Automatic bridge
function yes yes yes yes
1Outputs can vary depending on shape, size and quality of
the cookware.
2Specifications according to EU Regulation 66/2014.
Information about energy consumption can be found in the
product fiche.
,“9.1 Product data sheet” (page 42).
Specifications for the model (e.g. serial number, year of
construction) can be found on the ratings plate.

8
Product information
6006619_a – 12.01.2023
2.5 Scope of delivery
2.5.1 Hob extractor fan
C
A
B
D
E
A Powermover
B Intake grate
C Separator insert
D Hob with fan housing and connection cable
E Operating and installation instructions
Depending on the operating mode, further accessories are
required:
2Recirculating air kit DL BUF – installation variant for
recirculated air mode with active carbon filter.
2Recirculating air kit DL BUR – installation variant for
recirculated air mode with recirculated air filter permalyt.
2Exhaust air kit DL – installation variant for extracted air
mode.
-The instructions for installation variants with blow-out
grate kit must be observed.
2.5.2 Accessory recirculating air kit DLBUF
A
B
D
C
E
F
G
H
A Circulating air bend
B 2x recirculated air fan BUF 150 DL with adapter
C 150 mm shallow duct, 500 mm long
D 125 mm shallow duct, 1000 mm long
E Height compensation plates, thickness 0.5/1.0/1.5/2.0 mm
F 2x compression tape
G Sealing strip
H 2x fastening base

9
Product information
6006619_a – 12.01.2023
EN
2.5.3 Accessory recirculating air kit DLBUR
A
B
D
C
E
FG
HI
A Circulating air bend
B Recirculated air filter permalyt BUR BKA 125 DL with
adapter
C 150 mm shallow duct, 500 mm long
D 125 mm shallow duct, 1000 mm long
E Height compensation plates, thickness 0.5/1.0/1.5/2.0 mm
F Mains cable with plug and cold device plug
G 2x compression tape
H 2x sealing strip
I 2x fastening base
2.5.4 Accessory exhaust air kit DL
C
B
A
D
E
F
G
A 150 mm conduit bend, 90° vertical
B 150 mm elbow duct, 352 mm long
C 150 mm shallow duct, 500 mm long
D Height compensation plates, thickness 0.5/1.0/1.5/2.0 mm
E 2x fastening base
F 2x compression tape
G Sealing strip

10
Installation
6006619_a – 12.01.2023
3. Installation
3.1 Safety instructions for installation
.WARNING!
Hazard through disregard of the installation instructions!
This chapter contains important information for the safe
installation of the device.
1Read through this chapter carefully before installing the
device.
1Follow the safety instructions.
1Carry out the installation as described.
2Installation only by qualified specialist personnel.
,“1.2 Authorised target groups”(page 4).
2Electrical work must only be undertaken by qualified
electricians.
,“1.2 Authorised target groups”(page 4).
2The hob and other parts that can be touched must be
allowed to cool prior to installation.
2Store the film or other parts of the packaging in a location
which is inaccessible to children.
2The device must be in an undamaged and fault-free
condition prior to installation.
2Cables must not be kinked, crushed or damaged.
2Never open the fan housing.
2It is not permissible to attach further components
(e.g. panels, air ducts) to the device.
2The power supply voltage must match the voltage
information quoted on the ratings plate.
,“2.4 Technical data” (page 7).
2Ensure that the power supply is stable and remains so
prior to the installation.
Connect the power supply only when instructed to do so
in the installation instructions.
3.2 Requirements for the installation location
.WARNING!
Risk of death due to improper installation!
Disregard of the ambient conditions can lead to hazardous
situations, e.g. in the handling of electrical power or gas.
1Make sure that the requirements for the installation
location are complied with.
2Do not install in potentially explosive atmospheres.
2With simultaneous use of a heating point which uses air
from the room as its oxygen supply (e.g. chimneys):
2A safety device is absolutely essential.
2The safety device must prevent gases being drawing
to the room.
2It is essential to ensure that the negative pressure
in the heating point installation room does not
exceed 4 Pa.
2An approval for commissioning (e.g. from a chimney
sweep) must be available.
2If it is necessary to break through the wall:
A wall break-through influences the structural integrity
of the building. This work must only be carried out by a
specialist.
2Make sure that the building electrical supply is properly
earthed.
2The power supply voltage present must match the
voltage information quoted on the ratings plate.
2The customer must supply a means of connection to the
voltage supply in the installation area.
2The customer must provide a separate connection point
with dedicated fuse for the hob.
2An all-pole isolating device (with a contact gap of at least
3 mm) must be provided.
2Use of an extension cable for connection to the voltage
supply is not permitted.
2The hob must only be installed next to cabinets or walls
on one side in accordance with Type Y protection against
the risk of fire. Furniture or devices on the other side must
not be higher than the hob.
2The lateral distance from the hob to a wall or furniture
must be at least 40 mm.
2The distance to cabinets above the hob must be at least
600 mm.
2The device must not be installed above the following
devices:
2Oven without fan
2Dishwasher
2Clothes dryer
2The work top must be installed with heat-resistant
adhesive (75 °C), sealed with special paint, silicone rubber
or cast resin.
2Wall trim used in conjunction with installation must be
heat-resistant.
2The device must be installed in a lower cabinet with a
minimum width of 900 mm. If a recirculated air filter is
installed under the lower cabinet, the base height must
be at least 100 mm.

11
Installation
6006619_a – 12.01.2023
EN
2The device must remain accessible at all times for
maintenance work (e. g. with a removable rear panel or
service cover). The space must be sufficiently large to
allow for removal of the recirculated air filter.
2During recirculated air mode sufficiently large ventilation
slots must be available for the ventilation.
2The air flowing out must be able to dissipate unimpeded.
2If necessary for the installation, only use suitable hob
protection grates or hob covers.
1Please consult your dealer or customer services.
-Country-specific, legal provisions must be observed.
3.3 Requirements for individual operating modes
Depending on the operating mode, further accessories are
required:
3.3.1 Requirements for recirculated air mode
2Recirculating air kit DL BUF or DL BUR.
2Recirculated air fan on the fan outlet.
2Minimum size of the fan outlet opening in the lower
cabinet 2 x 250 cm2.
2Filter filling freely accessible for changing.
2The air escaping from the recirculation filter must be
fed out of the cabinet in a closed system (“guided
recirculating air”).
It is only possible to dispense with a guided recirculating
air system if cabinet or structural building damage due
to moisture (e.g. caused by condensate) can be fully
excluded.
2The installation variant with recirculated air filter permalyt
(recirculating air kit DL BUR) requires an additional 230 V
socket.
3.3.2 Requirements for extracted air mode
2Exhaust air kit DL.
2Exhaust air ducting at the fan outlet.
,“3.4 Requirements for the exhaust air ducting
(only for extracted air mode)” (page 11).
2Diameter of the exhaust air ducting at least 150 mm
(corresponds to a surface area of approx. 177 cm2).
2Adequate fresh air supply is assured through the
installation of the necessary accessories.
2Window contact switch BKA DL.
2Wall box.
3.4 Requirements for the exhaust air ducting
(onlyforextracted air mode)
.WARNING!
Fire hazard and asphyxiation hazard due to improper
installation!
When using the exhaust air ducting with other devices
or when connecting an active exhaust air channel (e.g.
chimney), gases or smoke can be drawn into the room.
1Make sure that the requirements for the exhaust air
ducting are complied with.
2The exhaust air ducting is used exclusively by this device.
2The exhaust air ducting is made of non-combustible
material.
2When using a chimney as the exhaust air duct:
2The chimney must not be used by other devices.
2The extracted air must be introduced into the
chimney using a 90° bend pointing upwards.
2Approval by a master chimney sweep.
2When routing the exhaust air ducting through the roof or
the outside wall:
2The cross-section must not be smaller than that of the
fan outlet.
2Installation of condensed water collector in the
exhaust air ducting in order to prevent water damage
inside the device. The condensed water collector must
be adequately dimensioned.
The cross-section, length, type and course of the exhaust
pipe affect the extraction efficiency. Changing the direction
of the air too severely leads to a loss of performance and to
noise.
To optimise the device performance:
2Keep the exhaust air ducting as short as possible (no
longer than 4 m) and route it directly to the outside.
2The stipulated cross-section of the exhaust air ducting is
complied with.
,“3.3 Requirements for individual operating modes”
(page 11).
2Exclusive use of ducts and bends with smooth inner
surfaces.
In order to avoid turbulence or backpressure in the
transported air - do not use:
2Spiral hoses.
2Flexible tubes.
2Flat deflection pieces.
2Sharp-edged exhaust air channels.
The exhaust air ducting must be in place before installing the
device.

12
Installation
6006619_a – 12.01.2023
3.5 Installation procedure
Short overview:
1. Preparation for installation
2. Unpack the device
3. Check the dimensions
4. Install the hob
5. Install recirculating air kit DL BUF
6. Install recirculating air kit DL BUR
7. Install exhaust air kit DL
8. Connect accessories
9. Connect light source (optional)
10. Establish electrical power supply
11. Check and carry out commissioning
3.5.1 Preparation for installation
The device is designed for installation in furniture structures.
The installation sequence may vary, depending on the local
conditions.
1Familiarise yourself with the installation situation and the
associated documents.
2Device and instructions.
2Intended operating mode and accessories.
2Installation location.
2Order documents.
2Dimensions, position and alignment of the
components.
1Assemble the tools and materials required:
2Set-down area (e.g. trestle)
2Folding rule or measuring tape
2Pencil
2Spirit level
2Saw
2Phillips head screwdriver, size 2
2Protective material (e.g. thick cardboard) for the hob
and the worktops
1Keep the installation area free of objects that could be in
the way or that could be damaged.
1Make sure that the hob and other parts that could be
touched have cooled down.
1Protect the hob and other surfaces in the installation area
(e.g. with thick cardboard).
1Ensure that the power supply is switched off and remains
so. Connect the power supply only when instructed to do
so in the installation instructions.
-The instructions for installation variants with blow-out
grate kit must be observed.
If accessories (e.g. wall box, window contact switch) are
required for the installation:
-Observe the instructions for the accessories.
1Ensure that the accessories are correctly installed and
ready for connection.
1Ensure that the connection cables from accessories are
correctly routed and accessible.
3.5.2 Unpack the device
.ATTENTION!
Hazard of glass breaking or other damage due to
incorrect handling!
The device and its surfaces can be damaged when being
unpacked or transported.
1Do not cut into the protective cardboard packaging.
1Keep objects that could scratch the device far away from
it (e.g. tools, belt buckles).
1Unpack the device and all accompanying parts carefully.
1Remove the Powermover, the intake grate and the
separator insert from the device.
1Set the device down with the hob facing upwards on a
firm, clean and protective surface (e.g. thick cardboard).
1Check the device and its constituent parts for damage.
1Ensure that the accessories are appropriate for the
intended operating mode.
1Check the delivery is complete.
,“2.5 Scope of delivery” (page 8).
If parts are missing or damaged:
1Please consult your dealer or customer services.
1Remove the packaging material and the protective film.
,“8.1 Dispose of packaging” (page 41).

13
Installation
6006619_a – 12.01.2023
EN
3.5.3 Check the dimensions
-To determine the dimensions of the hob, refer to the
order documents.
Flush installation
ab
x
z
y
≥ 37
Cutaway
Width (a) 810 + 2 mm
Depth (b) 485 + 2 mm
Corner radius R3
Milled recess
Width (x) 12 mm
Height (y) 5 mm
Outer dimensions 834 x 509 mm
Corner radius R5
Work top Height (z) > 10 mm
Counter-top installation
z
ab
≥ 50
Cutaway Width (a) 810 + 2 mm
Depth (b) 485 + 2 mm
Work top Height (z) > 10 mm
1Check the dimensions.
,“2.4 Technical data” (page 7).
1Ensure that the work top is suitable for the hob
installation.
A
B
1Check the spatial conditions for your installation variant.
A If necessary due to spatial conditions, (e.g. with large base
cabinets), shallow duct sections can be installed between
the opening on the fan housing and the circulating air
bend or conduit bend.
B If necessary due to spatial conditions, (e.g. with a short
distance from the wall), the circulating air bend or conduit
bend must be attached to the fan housing before the
hob is installed.

14
Installation
6006619_a – 12.01.2023
3.5.4 Install the hob
.WARNING!
Danger of injuries through improper handling!
Installation of the device requires a great deal of physical
exertion due to its size and weight. If the device falls down,
serious injuries are possible.
1Install the device with two persons.
1Ensure stable footing during installation.
1Ensure that no other people are in the working area.
.ATTENTION!
Danger of property damage through improper handling!
Installation of the device requires a great deal of physical
exertion due to its size and weight. If the device falls,
the device, kitchen furnishings and other objects could
be damaged.
1Cover the working surface.
1Keep the installation area clear.
-The instructions for installation variants with a hob frame
must be observed. The following step is omitted.
2 mm
1Remove the protective film from the sealing strip.
1Adhere the seal on the underside of the hob, leaving a
2 mm gap from the outer edge.
1Apply the sealing strip on all sides under the hob.
1Check that the inserted hob is at the correct height.
If necessary, position the appropriate height
compensation plates below the sealing strip. The height
compensation plates must be placed evenly.

15
Installation
6006619_a – 12.01.2023
EN
1Seal the cut surface of the work tip with suitable material
(heat resistant to 75 °C – e.g. special paint, silicone rubber
or cast resin).
-For the material used, the worktop manufacturer’s
instructions must be followed.
1Place the hob into the specified position in the lower
cabinet from above.
1Fit the separator insert in the opening of the hob.
1Fit the intake grate on the separator insert.
1Fit the Powermover on the intake grate.

16
Installation
6006619_a – 12.01.2023
3.5.5 Install recirculating air kit DLBUF
Installation variant for recirculated air mode with active
carbon filter.
-The instructions for installation variants with blow-out
grate kit must be observed.
The height of the recirculated air filter must be set such that
complete folding up is possible at all times for removal of the
filter cartridge.
1Unscrew the screw on the side of the recirculated air filter.
By trimming, it is possible to align the shallow duct with the
spacing between the connections:
2Between the fan‘s housing and circulating air bend with
deep base cabinets.
2Between the circulating air bend and recirculated air filter
with high base cabinets.
,“3.5.3 Check the dimensions”(page 13).
For the following steps, the adaptors of the air-carrying
components (e.g. circulating air bend, shallow duct sections)
must be sealed with sealing strip after they have been fit
together.
1Insert the circulating air bend in the connection on the
fan housing.
1Align the recirculated air filter with the flap device to the
access side. When doing so, observe the specification on
the device.
1Adjust the recirculated air filter position.
> 20
> 100
x
15
1Adjust the recirculated air filter to the appropriate height:
2Height-adjustability of at least 20 mm is necessary,
in order to be able to install the shallow duct sections
afterwards.
2The distance from the underside of the recirculated air
filter to the floor is at least 100 mm.
2The recirculated air filter can be folded up at any time
to remove the filter cartridge.
2The recirculated air filter must be set sufficiently high
that the cabinet base does not prevent folding back.
1Determine the length (x) of the shallow duct.
1Unscrew the screw on the side to lower the recirculated
air filter.

17
Installation
6006619_a – 12.01.2023
EN
x
1Cut the appropriate shallow duct sections. The quantity
and length must be adapted to the installation variant.
1Insert the shallow duct sections in the circulating air
bend.
1Re-adjust the recirculated air filter to the appropriate
height.
1Tighten the screw on the side of the recirculated air filter.
3.5.6 Install recirculating air kit DLBUR
Installation variant for recirculated air mode with recirculated
air filter permalyt.
-The instructions for installation variants with blow-out
grate kit must be observed.
By trimming, it is possible to align the shallow duct with the
spacing between the connections:
2Between the fan‘s housing and circulating air bend with
deep base cabinets.
2Between the circulating air bend and recirculated air filter
with high base cabinets.
,“3.5.3 Check the dimensions”(page 13).
For the following steps, the adaptors of the air-carrying
components (e.g. circulating air bend, shallow duct sections)
must be sealed with sealing strip after they have been fit
together.
1Insert the circulating air bend in the connection on the
fan housing.
1Correctly align the recirculated air filter.
1Position the recirculated air filter.

18
Installation
6006619_a – 12.01.2023
>20
> 30
x
15
1Adjust the recirculated air filter to the appropriate height:
2Height-adjustability of at least 20 mm is necessary,
in order to install the shallow duct sections afterwards.
2The distance from the underside of the recirculated air
filter to the floor is at least 30 mm.
1Determine the length (x) of the shallow duct.
1Unscrew the screw on the side to lower the recirculated
air filter.
x
1Cut the appropriate shallow duct sections. The quantity
and length must be adapted to the installation variant.
1Insert the shallow duct sections in the circulating air
bend.
1Re-adjust the recirculated air filter to the appropriate
height.
1Firmly tighten the screw on the side of the recirculated air
filter.
The recirculated air filter permalyt must be connected to the
hob extractor fan.
1Insert the connection plug of the recirculated air filter
permalyt into the control box on the fan housing.

19
Installation
6006619_a – 12.01.2023
EN
3.5.7 Install exhaust air kit DL
Installation variant for extracted air mode.
By trimming, it is possible to align the shallow duct with the
spacing between the connections:
2Between the fan housing and conduit bend with deep
base cabinets.
2Between the conduit bend and elbow duct with high
base cabinets.
x
1Cut the appropriate shallow duct sections. The quantity
and length must be adapted to the installation variant.
For the following steps, the adaptors of the air-carrying
components (e.g. conduit bend, shallow duct sections) must
be sealed with sealing strip after they have been fit together.
1Insert the conduit bend in the connection on the fan
housing.
1Insert the elbow duct in the conduit bend.
The routeing of the exhaust line takes place via a suitable
shallow duct system (not included in the scope of delivery).
1Ensure that the exhaust air duct is correctly fitted.
1Adhere sealing strip to the adapters.

20
Installation
6006619_a – 12.01.2023
3.5.8 Connect accessories
Available accessories are connected depending on the
installation situation:
2Wall box
-Observe the instructions for the accessories.
12 V DC
4
BMK-F BMK-F
2 31
C
A
BB
D
E
12 V DC
E
D
C
12 V DC
BMK3
BMK4
BMK2
BMK1
ST3
+
+
–
–
+
+
–
–
A Control box
2BMK1: Wall sleeve contact, optocoupler collector,
max. 12 mA / 12 V DC, safe galvanic separated
2BMK2: Wall box contact, optocoupler emitter,
max. 12 mA / 12 V DC, safe galvanically isolated
B Terminal “BMK-F”for the wall box connection
C Control line from the wall box
D Wall box
E Wall box mains adapter
Connection takes place via a 4-pole connection plug under
the service cover.
.ATTENTION!
Risk of damage through incorrect connection!
A mix-up of the control wires can result in damage to the
electronics.
1When connecting the control cable, ensure that the wires
are correctly assigned.
Wall box
1Connect the wall box as follows:
2Core 1 on terminal 1.
2Core 2 on terminal 2.
2The wall box is closed when the control contacts are
open.
2The wall box is open when the control contacts are
closed.
Window contact switches BKA DL can be connected via an
auxiliary control (optional).
1Please consult your dealer or customer services.
Table of contents
Other Berbel Fan manuals
Popular Fan manuals by other brands

Ansult
Ansult 022491 operating instructions

Greenheck
Greenheck 100 Series Installation, operation and maintenance manual

Manrose
Manrose MRUF150WH Installation and wiring instructions

Venmar
Venmar 3055 COMPACT user manual

TURNTIDE
TURNTIDE VES-Artex ECVD72 install guide

Panasonic
Panasonic F-30PLH operating instructions