Page 2 of 6 8631AF-8032AF Upgrade Instructions
Upgrade Procedure This upgrade assumes your OptiPac-3 8631AF is fully operational.
If you need assistance or have questions about this upgrade, contact
Bering Customer service by one of the following methods.
Phone: (408) 364-6500
Fax: (408) 364-6501
Upgrade the Firmware 1. Remove the OptiPac-3 from the rack mount by removing four screws from
the bottom of the rack mount.
2. Plug a power cord into the OptiPac-3 system.
3. While pressing both the ENTER and SELECT buttons, power on the
OptiPac-3. You can release the buttons after “wait for drive to power up”
appears in the LCD display. When the date and time is displayed continue
with the next step.
4. Press SELECT unitl Configurations is displayed, then press ENTER.
5. The LCD will display: Admin mode required.
6. Press SELECT and ENTER buttons at the same time until Administrator
Mode appears on the LCD.
7. Press SELECT until Return to Main apears, then press ENTER.
8. Press SELECT until Utilities appears, then press ENTER.
9. Press SELECT again to display the firmware ROM version.
10. Press SELECT until Tests is displayed and then press ENTER.
11. Press SELECT until Enable Firmware Load is displayed and then press
ENTER.
12. The LCD will display: Ready to Load Firmware!
13. Press SELECT.
14. The LCD will display: Disable Firmware Load.
15. Press SELECT.
16. The LCD will display: Load firmware cartridge?
17. Insert the firmware cartridge into the MO drive and wait for the cartridge to
spin up (about 10 seconds).
18. Press the ENTER button.
19. The LCD will display:
Bering DISK 8032
Ver F.B0 No
The version number varies from the above display. It should match the
version number printed on the label of the upgrade cartridge. If it displays
“No Loadable Firmware Found,” contact Bering Customer Service.
20. Press SELECT to change the No to Yes and then press ENTER. The Flash
memory will be erased and the firmware will be copied to the Flash
memory. When the firmware load is complete the cartridge will eject and
the OptiPac-3 will automatically reboot.
Note: Do not turn power off. Lost of power, the unit may become unusable and it
will have to be returned to factory to reload the firmware.
21. Remove the cartridge from the drive.
22. Enable Administrator mode, go to the Utilities menu and check the FW
version. It should now match the new firmware version (example: F.B0-nn)
23. Power off the unit and unplug the AC power cord.