BG Termic Zephyr User manual

User Manual
Zephyr
Decentralized Heat Recovery Device

Part List
1. Front cover part
2. Inside cover part
3. Wall fixture part
4. Outer hood
5. Capsule part
6. G3 Filter
7. Ceramic heat exchanger
8. 2-way fan
9. O-ring gasket
10. Outer pipe
2BG Termic Plus Østbirkvej 2 5240 Odense NØ Tlf. 65 99 49 95 [email protected] www.termicplus.dk
ENG-30.08.2022

Electrical Connection
For the electrical connection of the device, L and N lines of AC
220V/50Hz mains electricity are connected to the terminal
shown in the figure on the inner wall mounting part.
Electrical cable connections can be hidden by coming out of
the wall and passing through the cable hole in the part, or by
opening a hole on the side of the inner cover piece for the
cable to pass through.
Wall Montage
For the installation of BSK Zephyr room type heat recovery
device, first of all, a hole must be drilled on a wall facing
the exterior with the dimensions indicated in the figure.
In order for the water that may occur due to condensation
to flow outwards, it must be pierced outward with a slope
of 1-2 degrees.
After the wall is drilled, the outer pipe piece is cut in such
a way that it protrudes 10mm outside the wall and fixed
to the wall by applying various insulation materials or
polyurethane foam around it.
ENG-30.08.2022
3

1. The inner wall connection piece is placed on
the 10mm part of the PVC pipe piece outside
the wall and fixed to the wall with the help of
dowels.
2. The inner cover piece is mounted on the wall
connection piece and fixed to the piece by
screwing at the indicated places.
3. The capsule piece is aligned with the hole of
the device and snapped into place with the
ears facing to the side and the ear with the fan
socket facing to the left.
4. The front cover piece is seated by aligning it on
the inner cover piece from the hinges on it.
Make sure that all 2 hinges are in place.
4BG Termic Plus Østbirkvej 2 5240 Odense NØ Tlf. 65 99 49 95 [email protected] www.termicplus.dk
ENG-30.08.2022

5. The outer wall connection piece is placed in
such a way that it fits on the 10mm part of the
PVC pipe piece outside the wall and is fixed to
the wall with the help of dowels.
6. The outer grille piece is aligned and seated so
that it fits over the outer wall connector. Make
sure that the tabs on the parts fit well.
5
ENG-30.08.2022

Wireless Pairing of Multiple Devices (Blue panel)
BSK Zephyr devices can work individually or as a group by connecting to each other wirelessly. By
connecting devices in more than one room or in different rooms, you can also control other
connected devices through a single master device. Up to 15 different address groups can be created.
Stand-alone Device Mode; Your device will work in stand-alone
mode, without connecting to an another.
The address keys 3-4-5-6 are set to ON. Keys 1-2 don't matter.
Primary Device Mode; It creates a wireless network which secondary
devices with the same address can connect to and controls the
devices connected to it.
The #1 key is set to ON. The desired address is set from the address
keys # 3-4-5-6.
Secondary Device - Reverse Mode; It works in reverse to the
primary device by connecting to the primary device with the same
address. (E.g., Primary device blows air out while secondary
device does the reverse and takes air in)
The #1 and #2 key is set to OFF. Address keys 3-4-5-6 are set to be the
same as the primary device to be connected.
Secondary Device - Parallel Mode; It works in parallel with the
primary device by connecting to the primary device with the same
address. (E.g., Primary device blows air out while secondary device
does the same and blows air out)
The #1 key is set to OFF and the #2 key set to ON. Address keys 3-4-5-
6 are set to be the same as the primary device to be connected.
6BG Termic Plus Østbirkvej 2 5240 Odense NØ Tlf. 65 99 49 95 [email protected] www.termicplus.dk
Blue panel placed in the Wall fixture part
ENG-30.08.2022

Address List
Adress 0
(0000)
Adress 1
(0001)
Adress 2
(0010)
Adress
3
(0011)
Adress
4
(0100)
Adress
5
(0101)
Adress
6
(0110)
Adress
7
(0111)
Adress
8
(1000)
Adress
9
(1001)
Adress
10
(1010)
Adress
11
(1011)
Adress
1
2
(1100)
Adress 1
3
(1101)
Adress 1
4
(1110)
Stand
-
alone Mode
(1111)
7
Blue panel placed in the Wall fixture part
ENG-30.08.2022

IR Remote
On/Off Button:
When this button is pressed while the device is in the off position, the front cover will
open and the fan will start to operate. When this button is pressed while the device is on,
the front cover will be closed and the fan will stop.
Air Flow Mode Buttons
When the air flow control buttons are pressed, the device turns the air flow in the relevant direction.
Supply mode: The device will supply air from outside to inside continuously for 30
minutes. After 30 minutes, the device returns to the cycle mode. There is no heat
recovery in this mode.
Cycle mode: It is the default operating mode of the device. The device will change the
direction of the air flow every 70 seconds between supply mode and exhaust mode. This
mode recovers heat through the ceramic heat exchanger inside the device.
Exhaust mode: The device will exhaust air from inside to outside continuously for 30
minutes. After 30 minutes, the device returns to the loop mode. There is no heat recovery
in this mode.
Fan Speed buttons
When the fan speed control buttons are pressed, the device adjusts the fan speed to the relevant level.
Night Mode Speed I Speed II Speed III
15m3/h 30m3/h 45m3/h 60m3/h
When the night mode button is pressed, the device not only switches to the lowest fan speed, but also
closes the front cover a little more than its normal opening in order to reduce the noise levels further.
Humidity Level buttons
When the humidity level buttons are pressed, the device adjusts the set humidity value to the relevant
level.
8BG Termic Plus Østbirkvej 2 5240 Odense NØ Tlf. 65 99 49 95 [email protected] www.termicplus.dk
ENG-30.08.2022
IR Remote - remove the small piece of
plastic by the battery before use!

Level I Level II Level III
40% 60% 80%
Thanks to the humidity sensor on the device, it constantly controls the relative humidity level in the
environment. If the humidity level in the environment is above the determined level, the device
switches to shot mode for moisture evacuation. When the humidity level in the environment falls
below the specified level, the device continues to operate normally.
Long press the Level III button, the device turns off the automatic humidity mode. Regardless of the
humidity level, the device will not switch to the humidity evacuation mode.
9
ENG-30.08.2022

I
I
10 BG Termic Plus Østbirkvej 2 5240 Odense NØ Tlf. 65 99 49 95 [email protected] www.termicplus.dk
ENG-30.08.2022