REED vc04 User manual

reedinstruments
www com
Instruction
Manual
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Model VC04
Voltage/Current
Calibrator
www. .com information@itm.com1.800.561.8187

reedinstruments
www com
2
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Table of Contents
Safety ......................................................................................................... 3
Features...................................................................................................... 4
Specications..........................................................................................4-5
Instrument Description............................................................................6-7
Operating Instructions...........................................................................8-11
Power ON/OFF........................................................................................ 8
Automatic Power-Off ............................................................................... 8
Output Function ...................................................................................... 8
Output Operation Procedure ................................................................... 9
DC Voltage Output .................................................................................. 9
DC Current Output .............................................................................9-10
25% Step Current Output...................................................................... 10
Current Output Set for Zero Point & Full Scale ..................................10-11
Simulating Transmitter Output (XMT)...................................................... 11
Calibration ................................................................................................ 11
Battery Replacement................................................................................ 12
For service (repairs or calibration) on this or any other REED product
or information on other REED products, contact REED Instruments at
info@reedinstruments.com.
www. .com information@itm.com1.800.561.8187

reedinstruments
www com
3
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Safety
To prevent the user and the instrument from electric shock and other
hazards, it is necessary to follow the following regulations:
Warning
• Donotoperatetheinstrumentinthepresenceofammableor
explosive gas or vapor. This is extremely dangerous.
• Neverapplymorethan30Vbetweenanytwoterminals,orbetween
terminal and ground.
Caution
• Thesplitcase(topandbottom)isnottoberemoved,unlessby
qualied technicians.
• Tocleantheinstrument,periodicallywipethecasewithadamp
cloth and mild detergent, do not use any corrosive solvents.
Note
• Foroptimalaccuracy,allowtheinstrumenttowarmupfor5minutes
before operating.
www. .com information@itm.com1.800.561.8187

reedinstruments
www com
4
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Features
• Sources voltage and current
• 5-digit LCD readout
• Automatic calibration
• User selectable auto power-off
• Selectable step or ramp outputs
Specifications
Output Functions
Applicable range from 18 to 28°C, within one year of calibration.
Output Range Output Range Resolution Accuracy Note
DCV 10V 0.000to
11.000V 1mV 0.05%ofset
value±2mV
Max output
current:
2 mA
DCA 20mA 0.000to
22.000mA 0.001mA 0.05%ofset
value ±4μA
Max load:
1kΩat20mA
note 1
Analog
transmitter -20mA 0.000to
-22.000mA 0.001mA 0.05%ofset
value ±4μA
Max load:
1kΩat20mA
Loop
power 24V - - ±10%
Max output
current up to
25mA
Note 1: Whenthebatteryvoltageexceeds6.8V,themax.loadis1KΩat
20mA.Whenitsvoltageliesbetween5.8Vand6.8V,themax
loadis700Ωat20mA.
Note 2: Temperaturecoefcient:±0.005%oftherangeper°Cforthe
temperatureranges5°Cto18°Cand28°Cto40°C.
continued ...
www. .com information@itm.com1.800.561.8187

reedinstruments
www com
5
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
General Specifications
PowerSupply: Single9Valkalinebattery
Battery Life: Approx. 12 hours
Maxpermittedvoltage: 30V(betweenanytwoterminalsorbetween
any terminal and earth ground)
Operatingtemperature: 0°Cto50°C
Operatingrelativehumidity: ≤80%RH
Storagetemperature: ≤-10°Cto55°C
Storagehumidity: ≤90%RH
Safety: CertiedascomplianttoIEC1010provisions
Dimensions: 200x100x40mmw/holster
Weight: 550gw/holster
Includes: Test leads, alligator clips, protective holster,
soft carrying case, and battery
For service on this or any other REED product or information on other
www. .com information@itm.com1.800.561.8187

reedinstruments
www com
6
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
100%
+LOOP
30V
MAX
+ mA -
25%
ON
OUTPUT
30V
MAX
30V
MAX
XMT V
VmA%
VOLTAGE/mA
SOURCE
Instrument Description
1. LCD screen
2. Power button
3. ON/OFF
4. Zero/FSpointsselectbutton
5. 25%singlestepsetting/autorampbutton
6. UnitVmA/%selectbutton
7. UnitmA/%selectbutton
8. output digit selection button
9. output value setting button
10. Output terminals
7
8
9
10
1
2
3
4
5
6
continued ...
www. .com information@itm.com1.800.561.8187

reedinstruments
www com
7
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Display Description
Indicates that the instrument is in an output state
Indicates that the instrument is in a calibration state
Indicates that the instrument is in a calibration state, denoting
that the zero point or the full scale point is now in calibration
Indicates that the battery power is low and needs to be
replaced
Indicates that the output digits need to be set
V.mA.% Indicates the current output value (unit of measure)
Indicates that the output signal is on or off
www. .com information@itm.com1.800.561.8187

reedinstruments
www com
8
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Operating Instructions
Power ON/OFF
Press the Power button to turn the instrument on. Press this button again,
holding for one second to turn the instrument off. When the instrument is
on, it will begin an internal self-diagnosis at which time the full screen will
be displayed. Once complete, the instrument is ready to be used.
Automatic Power-Off
As a default the instrument will be set to automatically turn itself off
after10minuteswithoutanyaction.Followthestepsbelowtoturnthe
Auto-Power Off function off.
1. Be sure the meter is powered off.
2. PressboththePOWERandmA%/Vbuttonssimultaneously.
The display will indicate the symbol ‘AP-XX’.
3. Press the button to activate or deactivate the Auto-Power Off
function. ‘AP-OF’ indicates that there is no automatic power-off
functionset,and‘AP-ON’indicatestheautomaticpower-off
function is activated.
4. Turn the meter off to save the setting.
Output Function
The output terminal of the instrument can produce DC voltages set by the
user or simulating resistance.
Do not apply any voltage to the output terminal during the operation.
If any improper voltage is applied to the output terminal, it will cause
damage to the internal circuits.
www. .com information@itm.com1.800.561.8187

reedinstruments
www com
9
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
+
M
+LOOP
30V
MAX
mA
OUTPUT
30V
MAX
30V
MAX
XMT V
+
+LOOP
30V
MAX
mA
OUTPUT
30V
MAX
30V
MAX
XMT V
+
M
+LOOP
30V
MAX
mA
OUTPUT
30V
MAX
30V
MAX
XMT V
+
+LOOP
30V
MAX
mA
OUTPUT
30V
MAX
30V
MAX
XMT V
Output Operation Procedure
Function
Operation Range
Operation Display Set Range
DCA10mA 20mA% 0.000V 0.000to11.000V
-00.000to22.000mA
DC Voltage Output
1. InsertoneendofthetestleadsintotheV
output jack and connect the other end to
the input of the meter, as shown in the
diagram.
2. The symbol will appear on the
display indicating that the calibrator is in an
output state.
3. PresstheV/mAbuttontoselecttheVfunctionanddisplaytheV
unit.
4. Press the buttons to select the output digits.
5. Press the button to change the numerical value of the set
digits.Holdthebuttonandthevaluewillkeepvarying.
6. PresstheON/OFFbuttonturntheonandofftheoutputfollowed
bydisplayingtheONorOFFsymbol.
DC Current Output
1. Insert one end of the test leads into the
+mA output jack and connect the other
end to the input of the meter, as shown
in the diagram.
2. PresstheV/mAbuttontoselectthemA
function and display the mA unit.
3. PressthemA/%buttontoselectthemAor%functionand
displaythemAor%unit,inwhich0%is4mAand100%is20mA.
4. Press the buttons to select the output digits.
continued ...
www. .com information@itm.com1.800.561.8187

reedinstruments
www com
10
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
5. Press the button to change the numerical value of the set
digits.Holdthebuttonandthevaluewillkeepvarying.
6. PresstheON/OFFbuttonturntheonandofftheoutputfollowed
bydisplayingtheONorOFFsymbol.
25% Step Current Output
1. Connect the test leads to the meter as stated in the Current
Output procedures.
2. PresstheV/mAbuttontoselectthemAfunctionanddisplaythe
mAormA%unit.
3. PressthemaA25%buttonand will appear on the LCD.
4. PressthemA/%buttontoselectthesetoutputtomAor%and
displaythemAormA%unit.
5. Press the buttontochangetheoutputinavalueof25%,
inwhich0%indicates4mAand100%indicates20mA.
6. PresstheON/OFFbuttonturntheonandofftheoutputfollowed
bydisplayingtheONorOFFsymbol.
Current Output Set for Zero Point & Full Scale
1. Connect the test leads to the meter as stated in the Current
Output procedures.
2. PresstheV/mAbuttontoselectthemAfunctionanddisplaythe
mAormA%unit.
3. PressthemaA25%buttonand will appear on the LCD.
4. PressthemA/%buttontoselectthesetoutputtomAor%and
displaythemAormA%unit.
5. PresstheV/mAbuttontoselectthemAfunctionanddisplaythe
mAormA%unit.
6. PressthemA25%buttonand will appear on the LCD.
7. Press the button tochangetheoutputinavalueof100%,
inwhich0%indicates4mAand100%indicates20mA.Pressthe
mA100%toexitthestepcurrentoutput.
continued ...
www. .com information@itm.com1.800.561.8187

reedinstruments
www com
11
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
8. PresstheON/OFFbuttonturntheonandofftheoutputfollowed
bydisplayingtheONorOFFsymbol.
Simulating Transmitter Output (XMT)
1. Insert one end of the test lead to the ‘XMT’ output jack of the
calibrator and connect the other end with the input terminal of the
user’s instrument as shown in the following diagram:
2. The button-operation is the same as that as indicated in the
Current Output section.
Note:
• Powersupplyrange:5to25VDC.
• Duringanoutputoperation,useaexternal24VDCpowersupplyin
order to prolong battery life.
Calibration
It is recommended that you calibrate the unit once per year in order
to keep correct accuracies. Contact REED Instruments for assistance
regarding calibration, repairs, warranty, trouble-shooting, and more at
service@reedinstruments.com.
+
+
+LOOP
30V
MAX
mA
OU TPUT
30V
MAX
30V
MAX
XMT V
www. .com information@itm.com1.800.561.8187

reedinstruments
www com
12
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Battery Replacement
When the appears on the LCD, the batteries need to be replaced.
Follow the instructions below to properly replace the batteries.
1. Turn the power off the meter and remove any test leads that may
be attached to the meter.
2. Remove the holster from the calibrator by releasing the lock in the
indicated direction.
3. Replacetheoldbatterywithanew9Vbattery.Besuretocheck
polarities. Do not mix old batteries with new batteries.
4. Put the battery cover back on and lock it in the indicated direction.
Put the holster back on the calibrator.
For service (repairs or calibration) on this or any other REED product
or information on other REED products, contact REED Instruments at
info@reedinstruments.com.
www. .com information@itm.com1.800.561.8187
Table of contents
Other REED Test Equipment manuals
Popular Test Equipment manuals by other brands

Bacharach
Bacharach The Informant2 Operation and maintenance guide

Midtronics
Midtronics CTS-655P instruction manual

Tektronix
Tektronix 2215 instruction manual

Tektronix
Tektronix DF2 instruction manual

Webasto
Webasto 900EX Installation, operation and maintenance manual

Fluke
Fluke TL2X4W-TWZ instruction sheet