manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Biamp
  6. •
  7. Amplifier
  8. •
  9. Biamp DA28R User manual

Biamp DA28R User manual

DA28R
Distribution Amp / Router
Operation Manual
Biamp Systems, 10074 S.W. Arctic Drive, Beaverton, Oregon 97005 U.S.A. (503) 641-7287 www.biamp.com
an affiliate of Rauland Borg Corp.
print update
September 7, 2005
blank
1
DA28R
TABLE OF CONTENTS
Front & Rear Panel Features
Logic Input & Transformers
Applications
Specifications & Block Diagram
Warranty
pg. 2
pg. 3
pgs. 4 & 5
pg. 6
INTRODUCTION
The DA28R is a 2-in by 8-out distribution amp/router. Each input channel
accepts mic or line-level signals, and includes phantom power for condenser
microphones. All outputs are electronically balanced & floating line-level, with
600 ohm drive capability. Logic inputs allow routing of each input to specific
outputs via external contact-closures. The DA28R can operate as a flexible
2x8 distrubution amp, or as a complete 8-zone page-over-music routing
system. The DA28R carries a five-year warranty.
DA28R features include:
♦two electronically balanced, differential mic/line inputs
♦pad switch, trim control, & peak indicator on each input
♦24 volt phantom power switch on each input channel
♦eight electronically balanced & floating line outputs
(600 ohm line output drive capability)
♦screwdriver adjustable level control for each output
♦sixteen logic inputs with invert function switches
(mute/assign inputs to outputs via external switches)
♦inputs & outputs on plug-in barrier strip connectors
♦optional input and output isolation transformers
♦covered by Biamp Systems’ five-year warranty
♦marked and UL / C-UL listed power source
2
FRONT & REAR PANEL FEATURES
on
DA28R
50/60 Hz
~
27V
12 watts
class 2 wiring
logic inputs
logic inputs output 8 output 7 output 6 output 5 output 4 output 3 output 2 output 1 CH 1
+10
trim pad
+10
trim
CH 1
phantom
invert logic
phantom
invert logic
CH 2
levellevellevellevellevellevellevellevel pad
CH 2
DA28R
BIAMP SYSTEMS
Portland, Oregon
an affiliate of Rauland-Borg Corp.
INPUTSOUTPUTS
Input Connectors (Channels 1 & 2):These plug-in barrier strips
provide the balanced mic/line inputs for Channel 1 & Channel 2.
Input isolation transformers (model IT-A) are available as a user
installed option (see Transformers on pg. 3). For balanced input,
wire high (+), low (-), and ground (d). For unbalanced input, wire
high (+), and ground to both (d) & (-). Phantom power (+24VDC) is
available for condenser microphones (see DIP Switches below).
Trim (Channels 1 & 2):These screw-driver adjustable controls set
the channel gain (+24dB ~ +60dB) to compensate for different input
signal levels. For best performance, adjust these controls so the
channel +10 indicators flash only on occasional peaks. If input
signal level exceeds the normal operating range of the Trim control,
assign the corresponding channel Pad switch (see below). When
both inputs are assigned to common outputs, it may then be
necessary to reduce the Trim setting on one input, to establish a
proper level relationship (mix) between the two input signals.
Pad (Channels 1 & 2):When depressed, these switches reduce
the signal level at the respective input channels by 40dB. Use the
Pad switches whenever signal level at the associated input channel
exceeds the normal operating range of the Trim control. Typically,
a line-level input signal will require use of the Pad.
+10 Indicator (Channels 1 & 2):These red LEDs will light
whenever channel signal levels reach +10dB (8dB below clipping).
Use this feature to aid in adjusting the Trim controls (see above).
DIP Switches (Channels 1 & 2):These switches assign functions
to the input channels (when pushed up). Phantom turns on
+24VDC phantom power at the respective input, for use with
condenser microphones. CAUTION: Make sure phantom power is
turned off (switch down) when connecting line-level input signal.
Invert Logic reverses the operation of the respective Logic Inputs,
from ‘muting’ the associated channel at Outputs 1~8, to ‘unmuting’
the associated channel at Outputs 1~8 (see Logic Inputs below).
Output Connectors (Outputs 1~8):These plug-in barrier strips
provide the balanced line-level signals from Outputs 1~8. Output
isolation transformers (model IT-B) are available as a user installed
option (see Transformers on pg. 3). For balanced output, wire high
(+), low (-), and ground (d). For unbalanced output, wire high (+)
and ground (d), leaving (-) unconnected. Signal level will be
reduced by 6dB when outputs are unbalanced. Output 1~8 are
assigned signals from Channel 1 and/or Channel 2, by means of
DIP Switches & Logic Inputs (see below). From the factory, signals
from both input channels are assigned to all Outputs 1~8.
Level (Outputs 1~8):These screw-driver adjustable controls
provide level adjustment for the respective outputs. Use the Level
controls individually to set the desired signal level for each sound
system or device being fed. The range of the Level controls is from
‘OFF’ (fully counter-clockwise) to a maximum of +16dB of gain (fully
clockwise). From the factory, all Output 1~8 Level controls are set
fully counter-clockwise, to ‘OFF’.
Logic Inputs (Channels 1 & 2):This 25-pin Sub-D (female)
connector provides Logic Inputs 1~16 (on pins 1~16 respectively)
and a common ground (on pins 17~25). Logic Inputs allow signal
from Channel 1 & Channel 2 to be routed to the various outputs, via
external contact-closures. Logic Inputs 1~8 route Channel 1 to
Outputs 1~8 respectively. Logic Inputs 9~16 route Channel 2 to
Outputs 1~8 respectively. Logic Inputs perform either ‘muting’ or
‘unmuting’ functions, depending upon the position of the ‘Invert
Logic’ DIP Switches (see above). When ‘Invert Logic’ is assigned,
the associated input is normally muted at all outputs, and a contact-
closure will ‘unmute’ the input at the desired output. From the
factory, ‘Invert Locic’ is not assigned, both inputs are normally
unmuted at all outputs, and a contact-closure will ‘mute’ the input at
the desired output. Logic Inputs allow a variety of input/output
routing (see Logic Inputs on pg. 3 & Applications on pgs. 4 & 5).
AC Power Cord: The power transformer provides 27 Volts AC to
the DA28R, and is detachable via a 5-pin DIN connector. The
DA28R has two internal ‘self-resetting’ fuses (there are no user
serviceable parts inside the unit). If the internal fuses blow, they will
attempt to re-set after a short period. However, this may be an
indication that the unit requires service.
On Indicator: When the power transformer is plugged in, and AC
power is applied to the DA28R, the red On indicator remains lit.
3
LOGIC INPUTS & TRANSFORMERS
Logic Inputs: Logic Inputs 1~16 are on pins 1~16, and a common ground is on pins 17~25. Logic Inputs 1~8 affect routing of Channel 1
signal to Outputs 1~8, respectively. Logic Inputs 9~16 affect routing of Channel 2 signal to Outputs 1~8, respectively. Logic Inputs are
triggered by being shorted to ground, usually by means of external switches, relays, logic outputs, or other such contact-closures. However,
they may also be triggered permanently, via a ‘hard-wired’ short to ground (see Applications on pg. 5). Logic Inputs perform either ‘muting’
or ‘unmuting’ functions, depending upon the position of the ‘Invert Logic’ DIP Switches (see diagrams below). From the factory, ‘Invert Locic’
is not assigned on Channel 1 or Channel 2, and both inputs are normally unmuted (turned on) at all outputs. Contact-closures can then be
used to ‘mute’ (turn off) either input at selected outputs. When ‘Invert Logic’ is assigned, the associated input is normally muted (turned off)
at all outputs, and contact-closures can be used to ‘unmute’ (turn on) that input at selected outputs. A combination of ‘Invert Logic’ and
normal (non-inverted) logic operation allows Channels 1 & 2 to provide an override function. With a single switch wired to two corresponding
Logic Inputs (i.e…Logic Inputs 1 & 9), one input may be muted, while the other input is unmuted at the same output. This can be extremely
effective in multi-zone, page-over-music applications (see Applications on pgs. 4).
CH 1
phantom
invert logic
phantom
invert logic
CH 2
CH 1
phantom
invert logic
phantom
invert logic
CH 2
CH 1
phantom
invert logic
phantom
invert logic
CH 2
CH 1
phantom
invert logic
phantom
invert logic
CH 2
logic inputs
logic inputs
113
1425
Logic Inputs
pins 1~8
pins 9~16
pins 17~25
assign functions
ch-1 to outputs 1~8
ch-2 to outputs 1~8
common ground
Ch-1 & Ch-2
normally 'on'
(switches mute)
Ch-1 & Ch-2
normally 'off'
(switches unmute)
Ch-1 normally 'on'
(switches mute)
Ch-2 normally 'off'
(switches unmute)
Ch-1 normally 'off'
(switches unmute)
Ch-2 normally 'on'
(switches mute)
NOTE: The DA28R chassis must be dis-assembled before installing input/output transformers: 1) remove top panel (2 screws at bottom of
each side panel; 1 screw at top-center of rear panel). 2) remove screws from front panel (2 screws at each end). 3) remove hex-nuts from
rear panel (1 hex-nut each side of Logic Inputs connector). 4) remove mounting screws from circuit board (9 screws in front of rear panel
connectors; 2 screws behind each side of front panel). 6) gently pull circuit board forward (front panel comes forward; connectors exit rear
panel). 7) rotate front panel/circuit board upward, away from chassis (leave rear portion of circuit board in chassis, being careful not to strain
power cord connections).
Input Transformers: To install input transformers (see diagram at right): 1) locate
transformer positions T1 & T2 on the circuit board (circle areas located in front of input
connectors). T1 is for Channel 1 & T2 is for Channel 2. 2) un-solder & remove the 2
capacitors located within each of the appropriate circle areas. 3) install & solder an input
transformer at each of the appropriate circle areas (transformer pin 1, designated by a red dot,
must be inserted into the proper hole, designated by a square). Input isolation transformers
are model IT-A (P/N# 909-0010-01).
INPUT TRANSFORMERS
T1
cap cap
Output Transformers: To install output transformers (see diagram at right): 1) locate
transformer positions T101~T801 on the circuit board (rectangle areas located in front of output
connectors). T101 is for Output 1, T201 is for Output 2, etc. 2) un-solder & remove the 2
jumpers located within each of the appropriate rectangle areas. 3) install & solder an output
transformer at each of the appropriate rectangle areas (transformer pin 1, designated by a red
dot, must be inserted into the proper hole, designated by a square). Output isolation
transformers are model IT-B (P/N# 909-0019-00).
OUTPUT TRANSFORMERS
T101
R902
R901
4
APPLICATIONS
50/60 Hz
~
27V
12 watts
class 2 wiring
logic inputs
logic inputs output 8 output 7 output 6 output 5 output 4 output 3 output 2 output 1 CH 1
+10
trim pad
+10
trim
CH 1
phantom
invert logic
phantom
invert logic
CH 2
levellevellevellevellevellevellevellevel pad
CH 2
DA28R
BIAMP SYSTEMS
Portland, Oregon
an affiliate of Rauland-Borg Corp.
INPUTSOUTPUTS
2:50
1
COMPACT
DIGITALAUDIO
EIGHT ZONES OF PAGE-OVER-MUSIC ROUTING
CH 1 phantom
invert logic
phantom
invert logic
CH 2
DA28R
zone paging switches
to equalizers/amplifiers for eight zones of page-over-music
optional music
assign switches
background music sourcepaging microphone
paging mic (ch 2)
logic inputs set for
inverted operation.
Inverted operation of the
'paging mic' logic inputs
allows the microphone
push-to-talk switches
to un-mute the mic signal
at the appropriate outputs.
Non-inverted operation of
the 'music' logic inputs
assigns music to all outputs.
Music assign switches may
be added, which will mute
music at specific outputs
(music assign switches
require diode isolation).
logic inputs
113
1425
zone 1
zone 2
zone 3
zone 4
zone 5
zone 6
zone 7
zone 8
paging microphone
push-to-talk switches
logic inputs 1~8
un-mute the mic
logic inputs 9~16
mute the music
ground
5
APPLICATIONS
50/60 Hz
~
27V
12 watts
class 2 wiring
logic inputs
logic inputs output 8 output 7 output 6 output 5 output 4 output 3 output 2 output 1 CH 1
+10
trim pad
+10
trim
CH 1
phantom
invert logic
phantom
invert logic
CH 2
levellevellevellevellevellevellevellevel pad
CH 2
DA28R
BIAMP SYSTEMS
Portland, Oregon
an affiliate of Rauland-Borg Corp.
INPUTSOUTPUTS
TWO INDEPENDENT 1x4 DISTRIBUTION AMPS
CH 1
phantom
invert logic
phantom
invert logic
CH 2
DA28R
four outputs from input 2 (ch 2) four outputs from input 1 (ch 1)
input/output assignment
via hard-wired jumpers
input 1
input 2
both ch 1 & ch 2
logic inputs set for
normal operation.
Both inputs (ch 1 & ch 2)
are set for normal operation.
Normal operation allows
both inputs to be mixed and
sent to all eight outputs.
Hard-wired jumpers are then
connected to the appropriate
logic inputs, which mute each
input from specific outputs.
Input 1 (ch 1) is muted at
outputs 5~8. Input 2 (ch 2)
is muted at outputs 1~4.
logic inputs
113
1425
input/output assignment
via hard-wired jumpers
logic inputs 5~8
mute input 1 (ch 1)
from outputs 5~8
logic inputs 9~12
mute input 2 (ch 2)
from outputs 1~4
ground
6
SPECIFICATIONS & BLOCK DIAGRAM
Frequency Response (20Hz~20kHz): +0/-1dB Maximum Input: +24dBu
THD+Noise (20Hz~20kHz): < 0.03% Maximum Output (balanced): +24dBu
Noise Floor (20Hz~20kHz @ unity gain): < -75dBu Power Consumption: 10 Watts max.
Maximum Gain (mic in to balanced out): 79dB Dimensions:
Input Impedance (balanced): height 1.75 inches (44mm)
mic input 4.3k ohms width 19 inches (483mm)
line input 5.6k ohms depth 7.5 inches (190mm)
Output Impedance (balanced): 200 ohms Weight: 4.75 lbs. (2.16kg)
com
-
+
phantom
power
trim
level 1
peak
detect
peak
-40dB
pad
com
-
+
input
transformer
(optional)
input 1
mic/line
DA28R Block Diagram
DA28R Block Diagram
mic
preamp
output
transformer
(optional)
com
-
+
level 2
output
transformer
(optional)
com
-
+
level 3
output
transformer
(optional)
com
-
+
level 4
output
transformer
(optional)
com
-
+
phantom
power
trim
level 5
peak
detect
peak
-40dB
pad
com
-
+
input
transformer
(optional)
input 2
mic/line mic
preamp
output
transformer
(optional)
com
-
+
level 6
output
transformer
(optional)
com
-
+
level 7
output
transformer
(optional)
com
-
+
level 8
output
transformer
(optional)
output 1
output 2
output 3
output 4
output 5
output 6
output 7
output 8
+ 24V
ch 1 bus
ch 2 bus
+ 24V
S
S
S
S
S
S
S
S
logic input
routing control
logic inputs
1-16
WARRANTY
BIAMP SYSTEMS IS PLEASED TO EXTEND THE FOLLOWING 5-YEAR LIMITED WARRANTY TO THE
ORIGINAL PURCHASER OF THE PROFESSIONAL SOUND EQUIPMENT DESCRIBED IN THIS MANUAL
1. BIAMP Systems warrants to the original purchaser of new
products that the product will be free from defects in material
and workmanship for a period of 5 YEARS from the date of
purchase from an authorized BIAMP Systems dealer, subject to
the terms and conditions set forth below.
2. If you notify BIAMP during the warranty period that a BIAMP
Systems product fails to comply with the warranty, BIAMP
Systems will repair or replace, at BIAMP Systems' option, the
nonconforming product. As a condition to receiving the benefits
of this warranty, you must provide BIAMP Systems with
documentation that establishes that you were the original
purchaser of the products. Such evidence may consist of your
sales receipt from an authorized BIAMP Systems dealer.
Transportation and insurance charges to and from the BIAMP
Systems factory for warranty service shall be your responsibility.
3. This warranty will be VOID if the serial number has been
removed or defaced; or if the product has been altered,
subjected to damage, abuse or rental usage, repaired by any
person not authorized by BIAMP Systems to make repairs; or
installed in any manner that does not comply with BIAMP
Systems' recommendations.
4. Electro-mechanical fans, electrolytic capacitors, and normal
wear and tear of items such as paint, knobs, handles, and
covers are not covered under this warranty.
5. THIS WARRANTY IS IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED. BIAMP SYSTEMS
DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE.
6. The remedies set forth herein shall be the purchaser's sole
and exclusive remedies with respect to any defective product.
7. No agent, employee, distributor or dealer of Biamp Systems
is authorized to modify this warranty or to make additional
warranties on behalf of Biamp Systems. statements,
representations or warranties made by any dealer do not
constitute warranties by Biamp Systems. Biamp Systems shall
not be responsible or liable for any statement, representation or
warranty made by any dealer or other person.
8. No action for breach of this warranty may be commenced
more than one year after the expiration of this warranty.
9. BIAMP SYSTEMS SHALL NOT BE LIABLE FOR SPECIAL,
INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
INCLUDING LOST PROFITS OR LOSS OF USE ARISING OUT
OF THE PURCHASE, SALE, OR USE OF THE PRODUCTS,
EVEN IF BIAMP SYSTEMS WAS ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES.
Biamp Systems
10074 S.W. Arctic Drive
Beaverton, Oregon 97005
(503) 641-7287
585.0152.00

Other Biamp Amplifier manuals

Biamp 2500 User manual

Biamp

Biamp 2500 User manual

Biamp MXA Series User manual

Biamp

Biamp MXA Series User manual

Biamp CPA650 User manual

Biamp

Biamp CPA650 User manual

Biamp TesiraXEL 1200.2 Original operating instructions

Biamp

Biamp TesiraXEL 1200.2 Original operating instructions

Biamp PREZONE2 Original operating instructions

Biamp

Biamp PREZONE2 Original operating instructions

Biamp Tesira AMP-4175R User manual

Biamp

Biamp Tesira AMP-4175R User manual

Biamp AMP-450BP Original operating instructions

Biamp

Biamp AMP-450BP Original operating instructions

Biamp Vocia VA-2060 User manual

Biamp

Biamp Vocia VA-2060 User manual

Biamp MPA250 User manual

Biamp

Biamp MPA250 User manual

Biamp VOCIA VA-8600 User manual

Biamp

Biamp VOCIA VA-8600 User manual

Biamp Vocia VA-8150CV User manual

Biamp

Biamp Vocia VA-8150CV User manual

Biamp Tesira AMP-450P User manual

Biamp

Biamp Tesira AMP-450P User manual

Biamp 1200 User manual

Biamp

Biamp 1200 User manual

Biamp Vocia VA-4300CV User manual

Biamp

Biamp Vocia VA-4300CV User manual

Biamp Vocia ANC-1 User manual

Biamp

Biamp Vocia ANC-1 User manual

Biamp AUDIAFUSION User manual

Biamp

Biamp AUDIAFUSION User manual

Biamp Tesira AMP-450P Original operating instructions

Biamp

Biamp Tesira AMP-450P Original operating instructions

Biamp MCA SERIES User manual

Biamp

Biamp MCA SERIES User manual

Biamp Dynasound PRO DS1092 User manual

Biamp

Biamp Dynasound PRO DS1092 User manual

Biamp TC60 User manual

Biamp

Biamp TC60 User manual

Biamp CPA650 User manual

Biamp

Biamp CPA650 User manual

Biamp VOLTERA A Series Assembly instructions

Biamp

Biamp VOLTERA A Series Assembly instructions

Biamp CPA650 User manual

Biamp

Biamp CPA650 User manual

Biamp TesiraXEL 1200.1 Original operating instructions

Biamp

Biamp TesiraXEL 1200.1 Original operating instructions

Popular Amplifier manuals by other brands

T-audio TA-120 Operation manual

T-audio

T-audio TA-120 Operation manual

Dacs MicAmp2 user guide

Dacs

Dacs MicAmp2 user guide

AmpliVox SB602R manual

AmpliVox

AmpliVox SB602R manual

Fender STAGE 100 DSP Service manual

Fender

Fender STAGE 100 DSP Service manual

Crunch PD800.2 Quick start installation guide

Crunch

Crunch PD800.2 Quick start installation guide

Rotel RB-985 MKII owner's manual

Rotel

Rotel RB-985 MKII owner's manual

Hifonics Brutus BRZ 1200.1D user manual

Hifonics

Hifonics Brutus BRZ 1200.1D user manual

Macrom M1A.1500D owner's manual

Macrom

Macrom M1A.1500D owner's manual

Triple Play Communications AMP-1016B user manual

Triple Play Communications

Triple Play Communications AMP-1016B user manual

Yamaha MLA8 owner's manual

Yamaha

Yamaha MLA8 owner's manual

Fender SPL-M500 owner's manual

Fender

Fender SPL-M500 owner's manual

Linn LK240 owner's manual

Linn

Linn LK240 owner's manual

Adcom S.A.F.E. GFA-7705 quick start guide

Adcom

Adcom S.A.F.E. GFA-7705 quick start guide

Linear Power 1002 Owner's manual and installation guide

Linear Power

Linear Power 1002 Owner's manual and installation guide

Ready2Talk PA 64 Installation & operation manual

Ready2Talk

Ready2Talk PA 64 Installation & operation manual

Toa BG-10 Operation & instruction manual

Toa

Toa BG-10 Operation & instruction manual

Topp Music Gear THA-4 user manual

Topp Music Gear

Topp Music Gear THA-4 user manual

Teac HA-P50 owner's manual

Teac

Teac HA-P50 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.