Safety Notice
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction concerning use of the
appliance by a person responsible for their safety. Children should be supervised
to ensure that they do not play with the appliance.
Maintenance
Before any maintenance is carried out on the unit the electrical supply must be
isolated.
Maintenance should be restricted to dust and lint removal around the unit.
Do not tamper with any electrical parts
A installer should be used for other maintenance requirements.
Technical Data
Test Pressure: 20 bar
Maximum working pressure:10 bar
Electrical supply: 220-240 V –50 Hz.
Water connections: 15mm compression
5
Fault Finding
1. Fan does not run on any switch setting. a). Check the power supply is switched ON.
b). Check fuse in fused spur.
c). Check the wiring connections at the
fused spur.
2/ Heater does not switch on when a) Check switch is set to low or Boost
Central heating is on b) Check the unit is not air locked. Use
bleed valve in front of unit to release
any air
c) Balance the central heating system if
installed on same circuit as panel
radiators and increase the circulating
pump speed if required.
d) Increase the boiler temperature