Binks 84-346 User manual

EN
77-1758-R10.2 (11/2015) 1 / 4
SERVICE MANUAL
BINKS LOW PRESSURE DIAPHRAGM
FLUID REGULATORS
WITH ZINC BODY
84-346 KEY OPERATED
84-415 REMOTE CONTROL (OBSOLETE)
11
14
18
19
16 17 21
25
20 22
13
15
10
9
8
7
65
4
3
27
24
23
26
228
1
12
12
26
29
FOR MODEL 84-415
REGULATOR
UNREGULATED
FLUID INLET
REGULATED FLUID OUTLET
DETAIL “A”
See
Detail
“A”
STEM
FOLLOWER
WASHER
PIN
NOTE
Pre-assemble items 11, 12, 13, 18,
25 and 26 and tighten to
120 – 150 inch-pounds.
Item #1 screws: Tighten
to 35 –45 inch-pounds.
ITEM PART
NO. NO. DESCRIPTION QTY.
1 20-3699◆SOC. HD. CAP SCREW 10-24 x 1".... 6
2 20-4456 LOCKNUT (84-415).......................... 1
3 72-337 SWIVEL NUT ................................. 1
4 73-50 D. M. NIPPLE ................................ 1
5 83-1636 GAUGE (0 - 15 PSI)........................... 1
6 83-2052 GAUGE LENS (Replacement) ............ 1
7 84-40 CONNECTOR ................................ 1
8 84-321 BONNET........................................ 1
9 84-322* SCREW .......................................... 1
10 84-325* STEM ASSEMBLY.......................... 1
11 84-328 DISC .............................................. 1
12 84-329▲■ DIAPHRAGM ................................ 1
13 84-331 NUT............................................... 1
14 84-335▲VALVE ........................................... 1
15 84-338 TAIL PIECE .................................... 1
16 84-340* KEY ............................................... 1
ITEM PART
NO. NO. DESCRIPTION QTY.
17 84-341*▲SPRING.......................................... 1
18 84-342 RETAINER ..................................... 1
19 84-344 BODY............................................ 1
20 84-347 INLET ............................................ 1
21 84-353▲SPRING.......................................... 1
22 84-355 CAP ............................................... 1
23 84-393 SOCKET......................................... 1
24 84-395▲ROD .............................................. 1
25 84-398 DISC .............................................. 1
26 84-399▲■ DIAPHRAGM ................................ 1
27 84-450▲SEAT.............................................. 1
28 84-460 BODY (84-415) ................................ 1
29 84-463▲■ GASKET ........................................ 1
* Parts used only on Model 84-346 Regulator.
◆Before installing regulator, tighten all 6 flange screws securely.
▲Part of Repair Kit No. 84-591.
■ Part of Seal Kit Part No. 84-592.
PARTS LIST
When ordering, please specify Part No.

EN
77-1758-R10.2 (11/2015)2 / 4
WARNING
!
In this part sheet, the words WARNING, CAUTION and NOTE are used to emphasize important safety information as follows:
CAUTION
Hazards or unsafe practices which could
result in minor personal injury, product
or property damage.
!
WARNING
Hazards or unsafe practices which could
result in severe personal injury, death or
substantial property damage.
!
NOTE
Important installation, operation or
maintenance information.
Read the following warnings before using this equipment.
READ THE MANUAL
Before operating finishing equipment, read and
understand all safety, operation and maintenance
information provided in the operation manual.
ELECTRIC SHOCK/GROUNDING
Improper grounding or sparks can cause a
hazardous condition and result in fire, explosion
or electric shock and other serious injury.
PROJECTILE HAZARD
You may be injured by venting liquids or gases
that are released under pressure, or flying debris.
INSPECT THE EQUIPMENT DAILY
Inspect the equipment for worn or broken parts
on a daily basis. Do not operate the equipment
if you are uncertain about its condition.
NEVER MODIFY THE EQUIPMENT
Do not modify the equipment unless the
manufacturer provides written approval.
FIRE AND EXPLOSION HAZARD
Improper equipment grounding, poor ventilation,
open flame or sparks can cause hazardous
conditions and result in fire or explosion and
serious injury.
KNOW WHERE AND HOW TO SHUT OFF THE
EQUIPMENT IN CASE OF AN EMERGENCY
STATIC CHARGE
Fluid may develop a static charge that must be
dissipated through proper grounding of the
equipment, objects to be sprayed and all other
electrically conductive objects in the dispensing
area. Improper grounding or sparks can cause a
hazardous condition and result in fire, explosion
or electric shock and other serious injury.
WEAR SAFETY GLASSES
Failure to wear safety glasses with side shields
could result in serious eye injury or blindness.
OPERATOR TRAINING
All personnel must be trained before operating
finishing equipment.
EQUIPMENT MISUSE HAZARD
Equipment misuse can cause the equipment to
rupture, malfunction, or start unexpectedly and
result in serious injury.
KEEP EQUIPMENT GUARDS IN PLACE
Do not operate the equipment if the safety
devices have been removed.
HIGH PRESSURE CONSIDERATION
High pressure can cause serious injury. Relieve all
pressure before servicing. Spray from the spray
gun, hose leaks, or ruptured components can
inject fluid into your body and cause extremely
serious injury.
PRESSURE RELIEF PROCEDURE
Always follow the pressure relief procedure in the
equipment instruction manual.
DE-ENERGIZE, DEPRESSURIZE, DISCONNECT
AND LOCK OUT ALL POWER SOURCES DURING
MAINTENANCE
Failure to De-energize, disconnect and lock out
all power supplies before performing equipment
maintenance could cause serious injury or death.
FOR FURTHER SAFETY INFORMATION REGARDING BINKS AND DEVILBISS EQUIPMENT,
SEE THE GENERAL EQUIPMENT SAFETY BOOKLET (77-5300).
IT IS THE RESPONSIBILITY OF THE EMPLOYER TO PROVIDE THIS INFORMATION TO THE OPERATOR OF THE EQUIPMENT.
CA PROP
65
PROP 65 WARNING
WARNING: This product contains chemicals known
to the State of California to cause cancer and
birth defects or other reproductive harm.

EN
77-1758-R10.2 (11/2015) 3 / 4
INSTALLATION DATA
Installation is simplified by the use of a swivel nut inlet
connection (see illustration). This is standard on all
models; it eliminates the cost of a union, and provides a
quick and convenient method to easily remove the unit
from the line.
OPERATING INSTRUCTIONS
MOUNTING: Regulator (3/8" NPT (m) Inlet) may be mounted
in either a horizontal or vertical position. However, in all cases:
to operate properly, gauge riser tube must be in a vertical
position.
REGULATION: Use slotted end of key. Clockwise rotation
increases pressure; counter-clockwise rotation reduces pressure.
BLOW BACK: Use hexagon end of key. Turn counterclockwise
and gauge will read inlet pressure (main line pressure).
To shut off, turn key clockwise and gauge will return to normal
regulated reading when flow begins.
BUZZING: When regulated pressure climbs, it normally indi-
cates dirt on the seat; trigger gun rapidly to flush seat. If climb-
ing continues, open regulator to main line to flush. If climbing
still persists, replace valve and seat.
SERVICE INSTRUCTIONS
TO REPLACE FLUID VALVE AND SEAT:
Remove regulator from line by loosening
the swivel nut; always blow back regulator
before removing. At inlet, remove (counter-
clockwise rotation) slotted cap nut with
screwdriver; ball valve will slide off rod.
Unscrew (counter-clockwise rotation) hexa-
gon inlet retainer; valve seat will be
removed with retainer.
Remove valve seat from retainer and
replace if worn. Ball valve may be reversed
and reused unless both sides are worn.
To reassemble: insert valve seat into retain-
er; note position of shoulder. Place ball
valve on rod, and screw cap nut on rod and
tighten. Screw hex retainer on to body and
tighten. Regulator requires no adjustments.
TO REPLACE DIAPHRAGM:Remove
regulator from line. At inlet, remove slotted
cap nut with screwdriver; ball valve will
slide off rod.
Remove bonnet by loosening (6) socket head
cap screws. Clamp diaphragm assembly in
vise, loosen nut (13) and remove diaphragm.
To reassemble: reverse above procedure.
NOTE
Due to variations in diaphragm stretch, fluid flow may
not shut-off when the pressure is backed off to zero.
Install an inlet valve if complete shut-off is required.
NOTE
Fluid should be flowing through regulator when regulating
pressure.
CAUTION
When blowing back to reverse-flush regulator, be sure air
pressure does not exceed maximum rating of gauge.
!
Regulation Range 1 to 12 PSI 0.84 Kg/CM2
Max. Rec. Flow 12 Oz./Min. 357 C.C./Min.
Max. Inlet Pressure 100 PSI 7 Kg/CM2
2-3/4"
10-1/2"
UNION
CONNECTION
2-11/16"
3-1/2"
3-3/8"
6"3/8 NPS OUTLET
3/8 NPT INLET
Models with
remote control
air inlet 1/8
NPT(f) connect
to self-relieving
type air
regulator.
23
21
18
24
27
14
22

EN
77-1758-R10.2 (11/2015)4 / 4
Finishing Brands reserves the right to modify equipment specications without prior notice.
DeVilbiss®, Ransburg®, BGK®, and Binks® are registered trademarks of Carlisle Fluid Technologies, Inc.,
dba Finishing Brands. ©2015 Carlisle Fluid Technologies, Inc., dba Finishing Brands. All rights reserved.
WARRANTY POLICY
Binks products are covered by Finishing Brands one year materials and workmanship limited warranty.
The use of any parts or accessories, from a source other than Finishing Brands, will void all warranties.
For specic warranty information please contact the closest Finishing Brands location listed below.
Binks is part of Finishing Brands, a global leader in innovative spray nishing
technologies. For technical assistance or to locate an authorized distributor,
contact one of our international sales and customer support locations below.
USA/Canada
www.binks.com
Tel: 1-800-992-4657
Fax: 1-888-246-5732
United Kingdom
www.nishingbrands.eu
Tel: +44 (0)1202 571 111
Fax: +44 (0)1202 573 488
China
www.nishingbrands.com.cn
Tel: +8621-3373 0108
Fax: +8621-3373 0308
Mexico
www.carlisleft.com.mx
Tel: 011 52 55 5321 2300
Fax: 011 52 55 5310 4790
France
www.nishingbrands.eu
Tel: +33(0)475 75 27 00
Fax: +33(0)475 75 27 59
Japan
www.ransburg.co.jp
Tel: 081 45 785 6421
Fax: 081 45 785 6517
Brazil
www.devilbiss.com.br
Tel: +55 11 5641 2776
Fax: 55 11 5641 1256
Germany
www.nishingbrands.eu
Tel: +49 (0) 6074 403 1
Fax: +49 (0) 6074 403 281
Australia
www.nishingbrands.com.au
Tel: +61 (0) 2 8525 7555
Fax: +61 (0) 2 8525 7500
This manual suits for next models